Plan Review Details - Permit 07070454
Plan Review Stops For Permit 07070454
Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2007-09-26 Cont ID  
Sent By shill Date 2007-09-26 Time 18:14 Rev Time 0.00
Received By shill Date 2007-09-26 Time 18:14 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status F Date 2007-09-17 Cont ID  
Sent By shill Date 2007-09-17 Time 16:38 Rev Time 0.00
Received By shill Date 2007-09-17 Time 16:38 Sent To  
Notes
2007-09-17 16:39:56****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
  
 FAC FLORIDA ADMINISTRATIVE CODE
 FSFLORIDA STATUTE
  
 1.)THE RESPONSE LETTER STATED THAT I ASKED FOR ANCHOR
 SPACING BE CHANGED TO 4".THIS WAS NOT WHAT I
 INTENDED; I STATED THAT 4" WAS REQUIRED FOR SPANS OF
 12', WHICH WAS THE SPAN ON THE INSTALLATION SCHEDULE.
 A NEW INSTALLATION SCHEDULE HAS BEEN PROVIDED AND SPANS
 ARE FIXED.
  
 2.)SEE SHEET 14 OF THE PRODUCT APPROVAL.AN EDGE
 DISTANCE OF 3" REQUIRES A FACTOR OF .83 APPLIED TO THE
 ANCHOR SPACING.PLEASE REVISE.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2007-09-10 Cont ID  
Sent By shill Date 2007-09-10 Time 13:49 Rev Time 0.00
Received By shill Date 2007-09-10 Time 13:49 Sent To  
Notes
2007-09-10 13:52:51****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
  
 FAC FLORIDA ADMINISTRATIVE CODE
 FSFLORIDA STATUTE
  
 1.)PLEASE CLARIFY SPANS ON THE INSTALLATION SCHEDULE.
 THE SPAN SHOULD BE THE BLADE LENGTH, SO SHOULD
 CORRELATE WITH THE HEIGHT OF THE SHUTTER AND THE
 CONNECTION TYPE.FOR INSTANCE, OPENING 2, YOU'VE
 STATED THAT IT HAS A SPAN OF 12.1 FOR A 64" HIGH
 OPENING.ANCHOR SPACING IS COMPLIANT FOR A SPAN OF 6',
 BUT NOT 13' (4" SPACING REQUIRED RATHER THAN 10").
 PLEASE REVISE.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2007-08-22 Cont ID  
Sent By shill Date 2007-08-22 Time 17:39 Rev Time 0.00
Received By shill Date 2007-08-22 Time 17:39 Sent To  
Notes
2007-08-22 17:44:53****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2004
 FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL
  
 COMMENTS FROM PREVIOUS REVIEW:
  
 1.).COMPLETE THE ATTACHED INSTALLATION SCHEDULE OR
 PROVIDE ALL INFORMATION TO SHOW CODE COMPLIANCE IN
 ANOTHER FORMAT, FBC*106.THE INSTALLATION SCHEDULE
 PROVIDED WAS INCOMPLETE.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-08-06 Cont ID  
Sent By shill Date 2007-08-06 Time 10:22 Rev Time 0.00
Received By shill Date 2007-08-06 Time 10:22 Sent To  
Notes
2007-08-06 10:23:00****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2004
 FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL
  
  
 1.).COMPLETE THE ATTACHED INSTALLATION SCHEDULE OR
 PROVIDE ALL INFORMATION TO SHOW CODE COMPLIANCE IN
 ANOTHER FORMAT, FBC*106.

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2007-09-25 Cont ID  
Sent By adarroug Date 2007-09-25 Time 10:47 Rev Time 0.00
Received By adarroug Date 2007-09-25 Time 10:47 Sent To B
Notes
2007-09-25 10:47:38TO "SHILL' DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2007-09-17 Cont ID  
Sent By adarroug Date 2007-09-17 Time 14:04 Rev Time 0.00
Received By adarroug Date 2007-09-17 Time 14:04 Sent To B
Notes
2007-09-17 14:05:12TO "SHILL" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2007-09-06 Cont ID  
Sent By adarroug Date 2007-09-06 Time 16:24 Rev Time 0.00
Received By adarroug Date 2007-09-06 Time 16:24 Sent To B
Notes
2007-09-06 16:24:30TO "SHILL" DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-08-15 Cont ID  
Sent By adarroug Date 2007-08-15 Time 14:28 Rev Time 0.00
Received By adarroug Date 2007-08-15 Time 14:28 Sent To B
Notes
2007-08-15 14:29:01TO "SHILL' DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-08-06 Cont ID  
Sent By shill Date 2007-08-06 Time 10:23 Rev Time 0.00
Received By shill Date 2007-07-18 Time 13:36 Sent To  
Notes
2007-07-18 13:36:36TO "MISC" BOX#1


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved