Plan Review Stops For Permit 07070454 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
P |
Date |
2007-09-26 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-09-26 |
Time |
18:14 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-09-26 |
Time |
18:14 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
F |
Date |
2007-09-17 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-09-17 |
Time |
16:38 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-09-17 |
Time |
16:38 |
Sent To |
|
|
Notes |
2007-09-17 16:39:56 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBCFLORIDA BUILDING CODE 2004 | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | CODE | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | | FAC FLORIDA ADMINISTRATIVE CODE | | FSFLORIDA STATUTE | | | | 1.)THE RESPONSE LETTER STATED THAT I ASKED FOR ANCHOR | | SPACING BE CHANGED TO 4".THIS WAS NOT WHAT I | | INTENDED; I STATED THAT 4" WAS REQUIRED FOR SPANS OF | | 12', WHICH WAS THE SPAN ON THE INSTALLATION SCHEDULE. | | A NEW INSTALLATION SCHEDULE HAS BEEN PROVIDED AND SPANS | | ARE FIXED. | | | | 2.)SEE SHEET 14 OF THE PRODUCT APPROVAL.AN EDGE | | DISTANCE OF 3" REQUIRES A FACTOR OF .83 APPLIED TO THE | | ANCHOR SPACING.PLEASE REVISE. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2007-09-10 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-09-10 |
Time |
13:49 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-09-10 |
Time |
13:49 |
Sent To |
|
|
Notes |
2007-09-10 13:52:51 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBCFLORIDA BUILDING CODE 2004 | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | CODE | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | | FAC FLORIDA ADMINISTRATIVE CODE | | FSFLORIDA STATUTE | | | | 1.)PLEASE CLARIFY SPANS ON THE INSTALLATION SCHEDULE. | | THE SPAN SHOULD BE THE BLADE LENGTH, SO SHOULD | | CORRELATE WITH THE HEIGHT OF THE SHUTTER AND THE | | CONNECTION TYPE.FOR INSTANCE, OPENING 2, YOU'VE | | STATED THAT IT HAS A SPAN OF 12.1 FOR A 64" HIGH | | OPENING.ANCHOR SPACING IS COMPLIANT FOR A SPAN OF 6', | | BUT NOT 13' (4" SPACING REQUIRED RATHER THAN 10"). | | PLEASE REVISE. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2007-08-22 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-08-22 |
Time |
17:39 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-08-22 |
Time |
17:39 |
Sent To |
|
|
Notes |
2007-08-22 17:44:53 | ****CORRECTIONS**** | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | FBC FLORIDA BUILDING CODE 2004 | | FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL | | | | COMMENTS FROM PREVIOUS REVIEW: | | | | 1.).COMPLETE THE ATTACHED INSTALLATION SCHEDULE OR | | PROVIDE ALL INFORMATION TO SHOW CODE COMPLIANCE IN | | ANOTHER FORMAT, FBC*106.THE INSTALLATION SCHEDULE | | PROVIDED WAS INCOMPLETE. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2007-08-06 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-08-06 |
Time |
10:22 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-08-06 |
Time |
10:22 |
Sent To |
|
|
Notes |
2007-08-06 10:23:00 | ****CORRECTIONS**** | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | FBC FLORIDA BUILDING CODE 2004 | | FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL | | | | | | 1.).COMPLETE THE ATTACHED INSTALLATION SCHEDULE OR | | PROVIDE ALL INFORMATION TO SHOW CODE COMPLIANCE IN | | ANOTHER FORMAT, FBC*106. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2007-09-25 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-09-25 |
Time |
10:47 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-09-25 |
Time |
10:47 |
Sent To |
B |
|
Notes |
2007-09-25 10:47:38 | TO "SHILL' DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2007-09-17 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-09-17 |
Time |
14:04 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-09-17 |
Time |
14:04 |
Sent To |
B |
|
Notes |
2007-09-17 14:05:12 | TO "SHILL" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2007-09-06 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-09-06 |
Time |
16:24 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-09-06 |
Time |
16:24 |
Sent To |
B |
|
Notes |
2007-09-06 16:24:30 | TO "SHILL" DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2007-08-15 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-08-15 |
Time |
14:28 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-08-15 |
Time |
14:28 |
Sent To |
B |
|
Notes |
2007-08-15 14:29:01 | TO "SHILL' DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2007-08-06 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-08-06 |
Time |
10:23 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-07-18 |
Time |
13:36 |
Sent To |
|
|
Notes |
2007-07-18 13:36:36 | TO "MISC" BOX#1 |
|
|