Plan Review Details - Permit 07070452
Plan Review Stops For Permit 07070452 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2007-08-29 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-08-29 |
Time |
19:07 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-08-29 |
Time |
19:07 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2007-08-20 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-08-20 |
Time |
13:34 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-08-20 |
Time |
13:34 |
Sent To |
|
|
Notes |
2007-08-20 13:39:35 | ****CORRECTIONS**** | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | FBC FLORIDA BUILDING CODE 2004 | | FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL | | | | FROM PREVIOUS LIST: | | | | 1.).SEE OPENING 2.3" EDGE DISTANCE REQUIRES A | | FACTOR OF .83, SEE SHEET 11 OF THE PRODUCT APPROVAL. | | CHECK ALL OPENINGS. | | | | NOT ADDRESSED.FLOOR 6, CONCRETE SUBSTRATE, REQUIRES | | 10" SPACING WITH A FACTOR OF .83 (SEE SHEET 11); SHOULD | | BE 8". | | | | NEW COMMENTS: | | | | 2.)SUBSTRATE HAS BEEN REVISED TO WOOD ON SOME | | OPENINGS.SEE OPENING 1.WALL 4 AND WALL 5 WAS | | HIGHLIGHTED WITH 4" ANCHOR SPACING, SEE SHEET 12, BUT | | ON THE INSTALLATION SCHEDULE YOU STATE YOU ARE USING | | WALL 3.INFORMATION HIGHLIGHTED ON THE PRODUCT | | APPROVAL IS NOT CONSISTENT WITH THE INSTALLATION | | SCHEDULE.THERE ARE FOUR DIFFERENT WOOD SUBSTRATES; | | PLEASE PROVIDE ENOUGH INFORMATION TO DETERMINE CODE | | COMPLIANCE. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2007-08-06 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-08-06 |
Time |
10:44 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-08-06 |
Time |
10:44 |
Sent To |
|
|
Notes |
2007-08-06 10:45:53 | ****CORRECTIONS**** | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | FBC FLORIDA BUILDING CODE 2004 | | FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL | | | | | | 1.).SEE OPENING 2.3" EDGE DISTANCE REQUIRES A | | FACTOR OF .83, SEE SHEET 11 OF THE PRODUCT APPROVAL. | | CHECK ALL OPENINGS. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2007-08-24 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-08-24 |
Time |
09:08 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-08-24 |
Time |
09:08 |
Sent To |
B |
|
Notes |
2007-08-24 09:08:52 | TO "SHILL" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2007-08-16 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-08-16 |
Time |
10:44 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-08-16 |
Time |
10:44 |
Sent To |
B |
|
Notes |
2007-08-16 10:44:41 | TO "SHILL" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2007-08-06 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-08-06 |
Time |
10:46 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-07-18 |
Time |
13:34 |
Sent To |
|
|
Notes |
2007-07-18 13:34:57 | TO "MISC" BOX#1 |
|
|
|
Account Summary | Usage Policy | Privacy Policy