Plan Review Details - Permit 07070098
Plan Review Stops For Permit 07070098 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2007-09-10 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-09-10 |
Time |
18:41 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-09-10 |
Time |
18:41 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2007-08-27 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-08-27 |
Time |
13:01 |
Rev Time |
|
Received By |
shill |
Date |
2007-08-27 |
Time |
12:33 |
Sent To |
|
|
Notes |
2007-08-27 13:02:36 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBCFLORIDA BUILDING CODE 2004 | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | CODE | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC* | | CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 FAC | | FLORIDA ADMINISTRATIVE CODE | | FSFLORIDA STATUTE | | | | FROM PREVIOUS LIST: | | | | 1.)YOU'VE DESIGNED THIS JOB TO -47.2 PSF.ENGINEER | | HAS SPECIFIED DESIGN PRESSURE OF -51.6.YOU HAVE | | CHANGED THE DESIGN PRESSURE ON THE INSTALLATION | | SCHEDULE BUT DID NOT CHANGE THE ANCHOR SPACING, SEE | | SHEET 7 OF THE PRODUCT APPROVAL. | | | | THE PLANS WERE RETURNED WITH NO CORRECTIONS AND NOTES | | STATING:"CORRECT NEGATIVE PRESSURE IS CIRCLED ON | | TABLE 1" AND "POSITIVE PRESSURES IS 36.5 ANCHOR | | SCHEDULE IS CORRECT." | | | | PLEASE SEE THE PRODUCT APPROVAL, SHEET 7, WHICH I HAVE | | HIGHLIGHTED.TABLE 1 IS A TABLE FOR ALLOWABLE SPANS | | PER DESIGN PRESSURE.YOU HAVE CIRCLED -52, MAX | | ALLOWABLE SPAN OF 11'6.THIS INFORMATION IS CODE | | COMPLIANT FOR THIS JOB AND WAS NOT MENTIONED IN MY | | PREVIOUS REVIEW. | | | | THE ANCHOR SCHEDULE ON SHEET 7 IS FOR NEGATIVE | | PRESSURES.YOU HAVE CIRCLED 47.2, BUT AS THE NEGATIVE | | PRESSURE FOR THIS JOB IS -51.6, YOU SHOULD BE USING THE | | 77PSF ROW.IF I UNDERSTAND YOUR RESPONSE CORRECTLY, | | YOU ARE STATING THAT THE ANCHOR SCHEDULE IS FOR | | POSITIVE PRESSURES.THIS IS NOT CORRECT; THIS CHART IS | | TO BE USED FOR NEGATIVE PRESSURES AS THAT IS WORST | | CASE.PLEASE EITHER HAVE THE QUALIFIER CONTACT ME OR | | CONTACT THE ENGINEER FOR CLARIFICATION. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2007-08-21 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-08-21 |
Time |
07:16 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-08-21 |
Time |
07:16 |
Sent To |
|
|
Notes |
2007-08-21 07:19:30 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBCFLORIDA BUILDING CODE 2004 | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | CODE | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | FAC FLORIDA ADMINISTRATIVE CODE | | FSFLORIDA STATUTE | | | | 1.)YOU'VE DESIGNED THIS JOB TO -47.2 PSF.ENGINEER | | HAS SPECIFIED DESIGN PRESSURE OF -51.6.YOU HAVE | | CHANGED THE DESIGN PRESSURE ON THE INSTALLATION | | SCHEDULE BUT DID NOT CHANGE THE ANCHOR SPACING, SEE | | SHEET 7 OF THE PRODUCT APPROVAL. | | | | 2.)PLEASE SEE THE NOTE AT THE BOTTOM OF THE | | INSTALLATION SCHEDULE - "ANCHOR TYPE MUST BE SPECIFIC, | | EG. THERE ARE DIFFERENT TYPES OF TAPCONS WITH DIFFERENT | | STRENGTH VALUES."THE INSTALLATION SCHEDULE STATES | | "1/4" TAPCON".THERE ARE TWO DIFFERENT 1/4" TAPCONS ON | | THE ANCHOR SCHEDULE.IN THIS CASE, IT APPEARS THAT YOU | | ARE SPECIFYING ANCHORING FOR THE MORE STRINGENT.IF | | THIS IS NOT THE CASE, SPECIFIC ANCHOR TYPE WILL BE | | REQUIRED ON THE INSTALLATION SCHEDULE. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2007-07-26 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-07-26 |
Time |
19:35 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-07-26 |
Time |
19:35 |
Sent To |
|
|
Notes |
2007-07-26 19:36:16 | ****CORRECTIONS**** | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | FBC FLORIDA BUILDING CODE 2004 | | FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL | | | | SHUTTER PERMIT APPLICATION, ONLY CHECKED ITEMS APPLY | | | | _XX_1.PROVIDE BUILDING HEIGHT ON THE PLAN.DESIGN | | PRESSURES FOR BUILDINGS OVER 60FEET ARE REQUIRED TO BE | | DESIGNED USING ASCE7, FBC1609.1.1 AND MUST BE DONE BY A | | DESIGN PROFESSIONAL. DOCUMENTS PREPARED BY AN ARCHITECT | | OR ENGINEER AND SUBMITTED FOR PUBLIC RECORD ARE TO BE | | SIGNED SEALED ORIGINALS FAC61G15, FAC61G1 16. | | | | ____2.PROVIDE A COPY OF THE CONDO ASSOCIATION | | APPROVAL. | | | | ____3.COMPLETE THE ATTACHED INSTALLATION SCHEDULE | | OR PROVIDE ALL INFORMATION TO SHOW CODE COMPLIANCE IN | | ANOTHER FORMAT. | | | | ____4.FLORIDA STATE OR LOCAL PRODUCT APPROVAL | | REQUIRED, FAC9B72, WWW.FLORIDABUILDING.ORG. | | | | ____5.SHOW THE EMERGENCY MEANS OF ESCAPE, FBC | | R310. | | | | ____6.PROVIDE A FLOOR PLAN SHOWING WHERE THE | | SHUTTERS WILL BE INSTALLED AND PANEL SIZES WHICH | | CORRELATES WITH THE INSTALLATION SCHEDULE, ITEM 3 | | ABOVE. | | | | ____8.REVISE EXPOSURE CATEGORY FBC1609.6.2.1(2), | | FBC R301.2.1.4.NOTE THAT THE DEFINITION FOR EXPOSURE | | C HAS CHANGED EFFECTIVE DECEMBER 8, 2006 FBC1609.4, FBC | | R301.2.1.4. | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2007-09-05 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-09-05 |
Time |
12:04 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-09-05 |
Time |
12:04 |
Sent To |
B |
|
Notes |
2007-09-05 12:05:17 | TO "SHILL" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2007-08-27 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-08-27 |
Time |
08:31 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-08-27 |
Time |
08:31 |
Sent To |
B |
|
Notes |
2007-08-27 08:31:45 | TO "SHILL" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2007-08-09 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2007-08-09 |
Time |
09:52 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2007-08-09 |
Time |
09:52 |
Sent To |
B |
|
Notes |
2007-08-09 09:53:10 | TO SH'S DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2007-07-26 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-07-26 |
Time |
19:36 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-07-06 |
Time |
10:59 |
Sent To |
|
|
Notes |
2007-07-06 10:59:38 | TO "MISC" BOX#1 |
|
|
|