Plan Review Stops For Permit 07070066 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
F |
Date |
2007-11-08 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-11-08 |
Time |
13:05 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-11-08 |
Time |
13:05 |
Sent To |
|
|
Notes |
2007-11-08 13:07:34 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBCFLORIDA BUILDING CODE 2004 | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | CODE | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | FAC FLORIDA ADMINISTRATIVE CODE | | FSFLORIDA STATUTE | | | | FROM PREVIOUS LISTS: | | | | 1. SEE PREVIOUS LIST.THE MINIMUM SPACING IS 3".YOU | | CANNOT SPECIFY LESS THAN THIS NUMBER; YOU'VE CHANGED | | ALL ANCHOR SPACING TO 2".IT HAS TO BE 3" OR GREATER. | | | | NOW THE SPACING HAS BEEN REDUCED FROM 2 1/2" TO 2". | | THIS CANNOT BE LESS THAN 3", SEE PRODUCT APPROVAL, | | SHEET 7. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2007-10-30 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-10-30 |
Time |
12:11 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-10-30 |
Time |
12:10 |
Sent To |
|
|
Notes |
2007-10-30 12:12:08 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBCFLORIDA BUILDING CODE 2004 | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | CODE | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | | FAC FLORIDA ADMINISTRATIVE CODE | | FSFLORIDA STATUTE | | | | | | 1. SEE PREVIOUS LIST.THE MINIMUM SPACING IS 3".YOU | | CANNOT SPECIFY LESS THAN THIS NUMBER; YOU'VE CHANGED | | ALL ANCHOR SPACING TO 2".IT HAS TO BE 3" OR GREATER. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2007-08-26 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-08-26 |
Time |
16:12 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-08-26 |
Time |
16:12 |
Sent To |
|
|
Notes |
2007-08-26 16:16:05 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBCFLORIDA BUILDING CODE 2004 | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | CODE | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | FAC FLORIDA ADMINISTRATIVE CODE | | FSFLORIDA STATUTE | | | | 1.)SPANS SHOULD BE BLADE LENGTH (ONE DIMENSION). | | | | 2.)MINIMUM SPACING IS 3", SEE SHEET 7 (CANNOT SPECIFY | | 2 1/2" SPACING). | | | | 3.)SHUTTER CONNECTION MOUNTING TYPE SHOULD CORRELATE | | WITH ANCHOR SCHEDULES.YOU'VE HIGHLIGHTED "A" AND "I". | | REVISE INSTALLATION SCHEDULE; "HV" IS NOT A MOUNTING | | TYPE. | | | | 4.)A AND I ARE FOR POURED CONCRETE SUBSTRATES ONLY. | | YOUR INSTALLATION SCHEDULE STATES THAT THIS ENTIRE JOB | | HAS A BLOCK SUBSTRATE. | | | | 5.)9" SPACING WITH A .66 FACTOR REQURES 5.94" ANCHOR | | SPACING (CONCRETE SUBSTRATE, CONNECTION TYPE A, SEE | | PRODUCT APPROVAL).IT IS NOT CLEAR HOW YOU'VE | | DETERMINED THAT THE ANCHOR SPACING SHOULD BE 2 1/2". | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2007-07-26 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-07-26 |
Time |
18:15 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-07-26 |
Time |
18:15 |
Sent To |
|
|
Notes |
2007-07-26 18:15:23 | ****CORRECTIONS**** | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | FBC FLORIDA BUILDING CODE 2004 | | FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL | | | | SHUTTER PERMIT APPLICATION, ONLY CHECKED ITEMS APPLY | | | | ____1.PROVIDE BUILDING HEIGHT ON THE PLAN.DESIGN | | PRESSURES FOR BUILDINGS OVER 60FEET ARE REQUIRED TO BE | | DESIGNED USING ASCE7, FBC1609.1.1 AND MUST BE DONE BY A | | DESIGN PROFESSIONAL. DOCUMENTS PREPARED BY AN ARCHITECT | | OR ENGINEER AND SUBMITTED FOR PUBLIC RECORD ARE TO BE | | SIGNED SEALED ORIGINALS FAC61G15, FAC61G1 16. | | | | ____2.PROVIDE A COPY OF THE CONDO ASSOCIATION | | APPROVAL. | | | | _XX_3.COMPLETE THE ATTACHED INSTALLATION SCHEDULE | | OR PROVIDE ALL INFORMATION TO SHOW CODE COMPLIANCE IN | | ANOTHER FORMAT. | | | | ____4.FLORIDA STATE OR LOCAL PRODUCT APPROVAL | | REQUIRED, FAC9B72, WWW.FLORIDABUILDING.ORG. | | | | ____5.SHOW THE EMERGENCY MEANS OF ESCAPE, FBC | | R310. | | | | ____6.PROVIDE A FLOOR PLAN SHOWING WHERE THE | | SHUTTERS WILL BE INSTALLED AND PANEL SIZES WHICH | | CORRELATES WITH THE INSTALLATION SCHEDULE, ITEM 3 | | ABOVE. | | | | ____8.REVISE EXPOSURE CATEGORY FBC1609.6.2.1(2), | | FBC R301.2.1.4.NOTE THAT THE DEFINITION FOR EXPOSURE | | C HAS CHANGED EFFECTIVE DECEMBER 8, 2006 FBC1609.4, FBC | | R301.2.1.4. | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2007-11-06 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-11-06 |
Time |
11:46 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-11-06 |
Time |
11:46 |
Sent To |
B |
|
Notes |
2007-11-06 11:46:37 | TO "SHILL" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2007-10-25 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-10-25 |
Time |
14:15 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-10-25 |
Time |
14:15 |
Sent To |
B |
|
Notes |
2007-10-25 14:16:12 | TO "SHILL" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2007-08-21 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-08-21 |
Time |
14:58 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-08-21 |
Time |
14:58 |
Sent To |
B |
|
Notes |
2007-08-21 14:58:35 | TO "SHILL" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2007-07-26 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-07-26 |
Time |
18:15 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-07-05 |
Time |
10:24 |
Sent To |
|
|
Notes |
2007-07-05 10:24:55 | TO "MISC" BOX#1 |
|
|