Plan Review Details - Permit 07070050
Plan Review Stops For Permit 07070050
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2007-08-27 Cont ID  
Sent By kconrad Date 2007-08-27 Time 18:01 Rev Time 0.00
Received By kconrad Date 2007-08-27 Time 17:20 Sent To I
Notes
2007-08-27 17:32:16PROJECT: 205 SOUTHERN BLVD.
  
 PROJECT DETAIL: INSTALL FREE STANDING AWNING/CANOPY
  
 PLAN REVIEW: 2004 FLORIDA BUILDING CODE W/2006
 REVISIONS
  
  
 COMMENTS: PASSED
  
  
  
 REVIEW: KEN CONRAD
 PHONE: 561.805.6666

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-08-14 Cont ID  
Sent By kconrad Date 2007-08-14 Time 19:04 Rev Time 0.00
Received By kconrad Date 2007-08-14 Time 18:25 Sent To I
Notes
2007-08-14 19:04:29PROJECT: 205 SOUTHERN BLVD.
  
 PROJECT DETAIL: INSTALL FREE STANDING AWNING/CANOPY
  
 PLAN REVIEW: 2004 FLORIDA BUILDING CODE W/2006
 REVISIONS
  
  
 COMMENTS:
  
 1) PLEASE SHOW THE EXISTING CONCRETE SLAB THICKNESS.
  
 2) PLEASE INDICATE THE HEIGHT OF THE STRUCTURE:
  
 3105.1.1 LOCATION.
  
 3105.1.1.1
 FABRIC AWNINGS AND FABRIC-COVERED FRAMES LOCATED OVER
 PUBLIC PROPERTY OR IN AREAS ACCESSIBLE TO THE GENERAL
 PUBLIC SHALL BE CONSTRUCTED SO THAT NO RIGID PART OF
 SUCH FABRIC AWNINGS OR FABRIC-COVERED FRAMES SHALL BE
 LESS THAN 7 FEET, 6 INCHES (2286 MM) FROM THE GRADE
 DIRECTLY BELOW, AND NO PART OF THE CLOTH DROP SHALL BE
 LESS THAN 7 FEET (2134 MM).
 3105.1.1.2
 A FIXED FABRIC AWNING OR FABRIC-COVERED FRAME SHALL NOT
 EXTEND OVER PUBLIC PROPERTY MORE THAN TWO-THIRDS THE
 DISTANCE FROM THE PROPERTY LINE TO THE NEAREST CURB
 LINE IN FRONT OF THE BUILDING SITE AS MEASURED FROM THE
 EXTERIOR FACE OF THE BUILDING NOR SHALL ANY PORTION BE
 CLOSER THAN 18 INCHES (457 MM) TO THE CURB LINE.
 EXCEPTIONS:
 1. IF INSTALLED OVER 14 FEET (4267 MM) IN HEIGHT, IT
 MAY OCCUPY THE ENTIRE WIDTH OF THE SIDEWALK. 2. UNLESS
 OTHERWISE REGULATED BY LOCAL ZONING REQUIREMENTS.
  
 3)INDICATE THE TYPE AND SPACING OF THE PIPE TRUSSES.
  
 4) SHOW THAT THE AWNING FABRIC IS A QUICK REMOVAL
 SYSTEM:
  
 3105.4.2.1
 THE WIND DESIGN LOADS FOR ANY FABRIC OR
 MEMBRANE-COVERED STRUCTURE DESIGNED WITH A QUICK
 REMOVAL OR BREAKAWAY MEMBRANE OR FABRIC AT WIND
 VELOCITIES OF 75 MPH, SHALL BE BASED ON THE FOLLOWING
 CRITERIA:
 1. MINIMUM WIND VELOCITY OF 3-SECOND WIND GUST 90 MPH
 2. IMPORTANCE FACTOR BASED ON LOW HAZARD TO HUMAN LIFE
 OF 0.77.
 3. EXPOSURE CATEGORY B FOR OR C AS DEFINED IN CHAPTER
 16.
  
  
 REVIEW: KEN CONRAD
 PHONE: 561.805.6666
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-08-23 Cont ID  
Sent By adarroug Date 2007-08-23 Time 10:19 Rev Time 0.00
Received By adarroug Date 2007-08-23 Time 10:19 Sent To Z
Notes
2007-08-23 10:20:09TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-08-14 Cont ID  
Sent By kconrad Date 2007-08-14 Time 19:05 Rev Time 0.00
Received By kconrad Date 2007-07-05 Time 15:17 Sent To  
Notes
2007-07-05 15:18:43TO "Z" BOX

Review Stop Z ZONING
Rev No 2 Status P Date 2007-08-23 Cont ID  
Sent By choops Date 2007-08-23 Time 18:34 Rev Time 0.00
Received By choops Date 2007-08-23 Time 18:34 Sent To B
Notes
2007-08-23 18:37:06APPROVAL FOR AWNING ONLY.
  
 PROVISO:AWNING SHALL NOT EXCEED 30' IN HEIGHT.
 AWNING SHALL NOT BE USED FOR OUTDOOR DINING, AS NO
 PARKING HAS BEEN PROVIDED FOR THAT PURPOSE.

Review Stop Z ZONING
Rev No 1 Status F Date 2007-07-09 Cont ID  
Sent By choops Date 2007-07-09 Time 15:42 Rev Time 0.00
Received By choops Date 2007-07-09 Time 15:42 Sent To B
Notes
2007-07-09 15:45:08***FAILED***
  
  
 1)PROPOSED AWNING WILL REQUIRE FIVE (5) ADDITIONAL
 PARKING SPACES.AS THERE IS NOT SPACE TO ADD PARKING,
 THIS WILL NOT BE PERMITTED.
  
 2)DIMENSIONS NOT SHOWN ON SURVEY.
  
  
 QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, ZONING
 TECHNICIAN
 (561)805-6720