Plan Review Details - Permit 07070009
Plan Review Stops For Permit 07070009 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2007-08-29 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-08-29 |
Time |
19:24 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-08-29 |
Time |
19:24 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2007-08-21 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-08-21 |
Time |
10:18 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-08-21 |
Time |
10:18 |
Sent To |
|
|
Notes |
2007-08-21 10:20:12 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBC FLORIDA BUILDING CODE 2004 | | FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | | | | FROM PREVIOUS LIST: | | | | 1.)SEE INSTALLATION SCHEDULE.THE SHUTTER MOUNTING | | TYPE SHOULD STATE WHICH WALL CONNECTION YOU ARE USING. | | YOU HAVE HIGHLIGHTED BOTH WALL MOUNT 1 AND WALL MOUNT 3 | | ON THE PRODUCT APPROVAL.WALL MOUNT 1 IS FOR CONCRETE | | SUBSTRATE ONLY, ALL OPENINGS ARE CONCRETE BLOCK PER | | INSTALLATION SCHEDULE. | | | | SHUTTER MOUNTING TYPE STILL STATES "WALL".PLEASE | | SPECIFY WHICH WALL CONNECTION YOU ARE USING FOR TOP AND | | BOTTOM. | | | | NEW COMMENT: | | | | 2.)SEE SHEET 11.A 3" EDGE DISTANCE REQUIRES A | | FACTOR OF .83. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2007-08-08 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-08-08 |
Time |
14:37 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-08-08 |
Time |
14:37 |
Sent To |
|
|
Notes |
2007-08-08 15:07:57 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBC FLORIDA BUILDING CODE 2004 | | FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL FBC* CITY | | OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | | | | 1.)SEE INSTALLATION SCHEDULE.THE SHUTTER MOUNTING | | TYPE SHOULD STATE WHICH WALL CONNECTION YOU ARE USING. | | YOU HAVE HIGHLIGHTED BOTH WALL MOUNT 1 AND WALL MOUNT 3 | | ON THE PRODUCT APPROVAL.WALL MOUNT 1 IS FOR CONCRETE | | SUBSTRATE ONLY, ALL OPENINGS ARE CONCRETE BLOCK PER | | INSTALLATION SCHEDULE. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2007-07-26 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-07-26 |
Time |
09:15 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-07-26 |
Time |
09:15 |
Sent To |
|
|
Notes |
2007-07-26 09:16:52 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBC FLORIDA BUILDING CODE 2004 | | FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | | 1.COMPLETE THE ATTACHED INSTALLATION SCHEDULE OR | | PROVIDE ALL INFORMATION TO SHOW CODE COMPLIANCE IN | | ANOTHER FORMAT. | | | | 2.PROVIDE A FLOOR PLAN SHOWING WHERE THE SHUTTERS | | WILL BE INSTALLED AND PANEL SIZES WHICH CORRELATES WITH | | THE INSTALLATION SCHEDULE, ITEM 3 ABOVE. | | | | 3.PROVIDE A FLOOR PLAN SHOWING: WINDOW LOCATIONS, | | SIZES, WINDOW TYPE, ROOM DESIGNATIONS.NOTE EXISTING | | CONDITIONS (TYPE OF WINDOW) AND OPENING SIZE FOR | | BEDROOMS, FBC R310, FBC EB 505.1. | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2007-08-27 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-08-27 |
Time |
15:30 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-08-27 |
Time |
15:30 |
Sent To |
B |
|
Notes |
2007-08-27 15:31:11 | TO "SHILL" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2007-08-13 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-08-13 |
Time |
11:44 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-08-13 |
Time |
11:43 |
Sent To |
B |
|
Notes |
2007-08-13 11:44:13 | TO "SHILL" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2007-08-02 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-08-02 |
Time |
16:07 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-08-02 |
Time |
16:07 |
Sent To |
B |
|
Notes |
2007-08-02 16:07:30 | TO "SHILL" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2007-07-26 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-07-26 |
Time |
09:17 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-07-03 |
Time |
15:45 |
Sent To |
|
|
Notes |
2007-07-03 15:45:44 | TO "MISC" BOX#1 |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |