Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2007-10-18 Cont ID  
Sent By kconrad Date 2007-10-18 Time 16:50 Rev Time 0.00
Received By kconrad Date 2007-10-18 Time 15:45 Sent To I
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2007-08-27 Cont ID  
Sent By kconrad Date 2007-08-27 Time 17:13 Rev Time 0.00
Received By kconrad Date 2007-08-27 Time 16:00 Sent To I
Notes
2007-08-27 17:11:25PROJECT: 736 FLAMINGO DRIVE
  
 PROJECT DETAIL: INSTALL 14 AWNINGS/NON-IMPACT
  
 PLAN REVIEW: 2004 FLORIDA BUILDING CODE W/ 2006
 REVISIONS
  
  
 STATUS: 1ST RESUB FAILED
  
 COMMENTS:
  
  
  
  
 1) PLEASE SHOWMECHANICAL CONNECTION DETAIL OF CAMEL
 BACK AND ALUMINUM HEADER TO MAINFRAME OF EXISTING
 STRUCTURE:
  
 A) ANCHOR TYPE, DIAMETER, AND LENGTH.
 B) MINIMUM ANCHOR EMBEDMENT INTO MASONRY/WOOD
 STRUCTURE.
  
 2) SATISFY PLANING AND ZONING REQUIREMENTS.
  
 REVIEW: KEN CONRAD
 PHONE: 805.6666

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-08-08 Cont ID  
Sent By kconrad Date 2007-08-08 Time 20:12 Rev Time 0.00
Received By kconrad Date 2007-08-08 Time 18:35 Sent To I
Notes
2007-08-08 20:11:58PROJECT: 736 FLAMINGO DRIVE
  
 PROJECT DETAIL: INSTALL 14 AWNINGS/NON-IMPACT
  
 PLAN REVIEW: 2004 FLORIDA BUILDING CODE W/ 2006
 REVISIONS
  
  
 STATUS: FAILED
  
 COMMENTS:
  
 1)PLEASE SHOW THAT THE AWNING STRUCTURAL FRAMING
 MEETS THE APPLICABLE WIND LOADS BASED ON RATIONAL
 ANALYSIS:
  
 3105.4.2
 DESIGN OF THE STRUCTURAL FRAMING MEMBERS SHALL BE BASED
 ON RATIONAL ANALYSIS, USING THE APPLICABLE WIND LOADS
 OF CHAPTER 16 AS SHOWN BELOW:
  
 3105.4.2.1
 THE WIND DESIGN LOADS FOR ANY FABRIC OR
 MEMBRANE-COVERED STRUCTURE DESIGNED WITH A QUICK
 REMOVAL OR BREAKAWAY MEMBRANE OR FABRIC AT WIND
 VELOCITIES OF 75 MPH, SHALL BE BASED ON THE FOLLOWING
 CRITERIA:
 1. MINIMUM WIND VELOCITY OF 3-SECOND WIND GUST 90 MPH
 2. IMPORTANCE FACTOR BASED ON LOW HAZARD TO HUMAN LIFE
 OF 0.77.
 3. EXPOSURE CATEGORY B FOR OR C AS DEFINED IN CHAPTER
 16.
  
 2) PLEASE SUBMIT PHOTOGRAPHS INDICATING HOW THE FABRIC
 WILL BE QUICK RELEASED FROM THE FRAMING.
  
 3) STRUCTURES SHALL BE LABELED AS FOLLOWS:
  
 3105.5.3
 STRUCTURES DESIGNED TO BE READILY REMOVED OR
 REPOSITIONED DURING PERIODS OF HIGH WIND VELOCITY SHALL
 BE POSTED WITH A LEGIBLE AND READILY VISIBLE DECAL OR
 PAINTED INSTRUCTIONS TO THE OWNEROR TENANT
 TO REMOVE OR REPOSITION THE STRUCTURE OR PART THEREOF
 DURING SUCH PERIODS OF TIME AS ARE DESIGNATED BY THE
 U.S. WEATHER BUREAU AS BEING A HURRICANE WARNING OR
 ALERT.
  
 4) PLEASE SHOW CONNECTION DETAIL OF CAMEL BACK TO
 MAINFRAME OF EXISTING STRUCTURE:
  
 A) ANCHOR TYPE, DIAMETER, AND LENGTH.
 B) MINIMUM ANCHOR EMBEDMENT INTO MASONRY/WOOD
 STRUCTURE.
  
 5) SATISFY PLANING AND ZONING REQUIREMENTS.
  
  
 PLAN REVIEW: KEN CONRAD
 PHONE: 561.805.6666
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2007-10-09 Cont ID  
Sent By adarroug Date 2007-10-09 Time 11:19 Rev Time 0.00
Received By adarroug Date 2007-10-09 Time 11:19 Sent To Z
Notes
2007-10-09 11:19:24TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-08-23 Cont ID  
Sent By adarroug Date 2007-08-23 Time 15:39 Rev Time 0.00
Received By adarroug Date 2007-08-23 Time 15:39 Sent To Z
Notes
2007-08-23 15:40:05TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-08-08 Cont ID  
Sent By kconrad Date 2007-08-08 Time 20:12 Rev Time 0.00
Received By kconrad Date 2007-06-29 Time 09:26 Sent To  
Notes
2007-06-29 09:26:31TO "Z" BOX

Review Stop Z ZONING
Rev No 3 Status P Date 2007-10-12 Cont ID  
Sent By choops Date 2007-10-12 Time 08:24 Rev Time 0.00
Received By choops Date 2007-10-12 Time 08:24 Sent To B
Notes
2007-10-12 08:25:20***APPROVED - RESUB #2***
  
 PROVISO AWNINGS TO PROJECT NO MORE THAN 4' INTO ANY
 REQUIRED SETBACK.
  
  
  
 SENT TO "B" - KC

Review Stop Z ZONING
Rev No 2 Status F Date 2007-08-27 Cont ID  
Sent By choops Date 2007-08-27 Time 16:20 Rev Time 0.00
Received By choops Date 2007-08-27 Time 16:20 Sent To B
Notes
2007-08-27 16:24:48***FAILED******RESUB #1***
  
  
 1)PURSUANT TO THE CITY OF WEST PALM BEACH ZONING AND
 LAND DEVELOPMENT REGULATIONS, SECTION 94-305(5):
  
 AWNINGS SHALL NOT PROJECT MORE THAN FOUR FEET INTO ANY
 SETBACK OR BE SUPPORTED BY ANY MEANS OTHER THAN
 ATTACHMENT TO THE BUILDING.
  
  
  
 QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, ZONING
 TECHNICIAN
 (561)805-6720

Review Stop Z ZONING
Rev No 1 Status F Date 2007-07-03 Cont ID  
Sent By choops Date 2007-07-03 Time 14:20 Rev Time 0.00
Received By choops Date 2007-07-03 Time 14:20 Sent To B
Notes
2007-07-03 14:25:01***FAILED***
  
  
 1)PLEASE PROVIDE 2 COPIES OF A CURRENT SURVEY
 SHOWING THE LOCATION OF ALL AWNINGS.INCLUDE THE
 DIMENSION AWNINGS PROTRUDE FROM HOUSE.
  
  
 QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, ZONING
 TECHNICIAN
 (561)805-6720