Plan Review Stops For Permit 07060912 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
P |
Date |
2007-11-05 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-11-05 |
Time |
18:32 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-11-05 |
Time |
18:32 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
F |
Date |
2007-10-02 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-10-02 |
Time |
16:26 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-10-02 |
Time |
16:26 |
Sent To |
|
|
Notes |
2007-10-02 16:31:42 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBCFLORIDA BUILDING CODE 2004 | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | CODE | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC* | | CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 FAC | | FLORIDA ADMINISTRATIVE CODE | | FSFLORIDA STATUTE | | | | FROM PREVIOUS LIST: | | | | 1.)THE FIRST COMMENT LIST REQUESTED THAT YOU SHOW HOW | | EGRESS IS AFFECTED.YOU ARE BLOCKING THREE DOORS, | | INCLUDING THE MAIN ENTRY DOOR.YOU CANNOT BLOCK A | | REQUIRED MEANS OF EGRESS WITH HURRICANE SHUTTERS. | | PLEASE SEE FBC CHAPTER 10, PARTICULARLY FBC1001.4 | | (CANNOT REDUCE THE REQUIRED MEANS OF EGRESS), FBC1007.1 | | AND FBC11, FBC1008 (DOORS).PROVIDE A LIFE SAFETY PLAN | | INCLUDING FLOOR PLAN, PATH OF TRAVEL, OCCUPANCY | | CLASSIFICATION FBC3, OCCUPANT LOAD FBC10.YOU CANNOT | | BLOCK THE MAIN ENTRANCE.IT IS NOT CLEAR IF THE OTHER | | TWO DOORS ARE REQUIRED MEANS OF EGRESS OR ACCESSIBLE | | MEANS OF EGRESS.PROVIDE PLANS WHICH SHOW CODE | | COMPLIANCE, TO BE PREPARED BY A DESIGN PROFESSIONAL. | | | | COMMENT NOT ADDRESSED.SEE THE FOLLOWING CODES, ALL | | WHICH PROHIBIT BLOCKING THE REQUIRED EXITS:FBC1001.2 | | (UNLAWFUL TO ALTER A BUILDING THAT WILL REDUCE THE | | NUMBER OF EXITS OR THE CAPACITY OF THE MEANS OF EGRESS | | TO LESS THAN REQUIRED), FBC1003.6 (PATH OF EGRESS | | TRAVEL SHALL NOT BE INTERRUPTED BY ANY BUILDING ELEMENT | | OTHER THAN A MEANS OF EGRESS COMPONENT).SOMEONE WROTE | | "EGRESS IS PROVIDED BY SHUTTERS THAT CAN BE DEPLOYED | | AND REMOVED FROM THE NSIDE OR OUTSIDE."THERE IS | | PROVISION FOR THIS IN RESIDENTIAL CODE, BUT NOT IN | | FLORIDA BUILDING CODE.IF YOU FEEL THAT I AM | | INCORRECT, PROVIDE THE CODE SECTION WHICH ALLOWS THIS. | | | | | | DO NOT RESUBMIT WITHOUT THE REQUIRED LIFE SAFETY PLAN | | SHOWING ALL REQUIRED EXIT DOORS UNLESS YOUR SHUTTER | | PLAN IS TO INCLUDE WINDOWS ONLY. | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2007-09-13 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-09-13 |
Time |
09:49 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-09-13 |
Time |
09:49 |
Sent To |
|
|
Notes |
2007-09-13 09:55:01 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBCFLORIDA BUILDING CODE 2004 | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | CODE | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC* | | CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | FACFLORIDA ADMINISTRATIVE CODE | | FSFLORIDA STATUTE | | | | 1.)THE FIRST COMMENT LIST REQUESTED THAT YOU SHOW HOW | | EGRESS IS AFFECTED.YOU ARE BLOCKING THREE DOORS, | | INCLUDING THE MAIN ENTRY DOOR.YOU CANNOT BLOCK A | | REQUIRED MEANS OF EGRESS WITH HURRICANE SHUTTERS. | | PLEASE SEE FBC CHAPTER 10, PARTICULARLY FBC1001.4 | | (CANNOT REDUCE THE REQUIRED MEANS OF EGRESS), FBC1007.1 | | AND FBC11, FBC1008 (DOORS).PROVIDE A LIFE SAFETY PLAN | | INCLUDING FLOOR PLAN, PATH OF TRAVEL, OCCUPANCY | | CLASSIFICATION FBC3, OCCUPANT LOAD FBC10.YOU CANNOT | | BLOCK THE MAIN ENTRANCE.IT IS NOT CLEAR IF THE OTHER | | TWO DOORS ARE REQUIRED MEANS OF EGRESS OR ACCESSIBLE | | MEANS OF EGRESS.PROVIDE PLANS WHICH SHOW CODE | | COMPLIANCE, TO BE PREPARED BY A DESIGN PROFESSIONAL. | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2007-09-05 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-09-05 |
Time |
17:53 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-09-05 |
Time |
17:53 |
Sent To |
|
|
Notes |
2007-09-05 17:53:31 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBCFLORIDA BUILDING CODE 2004 | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | CODE | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC* | | CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | | FAC FLORIDA ADMINISTRATIVE CODE | | FSFLORIDA STATUTE | | | | 1.)NO DOORS WERE SHOWN ON THE PLAN.PLEASE SHOW HOW | | EGRESS WILL BE AFFTECTED, FBC10. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2007-07-13 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-07-13 |
Time |
14:25 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-07-13 |
Time |
14:24 |
Sent To |
|
|
Notes |
2007-07-13 14:25:47 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBC FLORIDA BUILDING CODE 2004 | | FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | | SHUTTER PERMIT APPLICATION, ONLY CHECKED ITEMS APPLY | | | | ____1.PROVIDE BUILDING HEIGHT ON THE PLAN.DESIGN | | PRESSURES FOR BUILDINGS OVER 60FEET ARE REQUIRED TO BE | | DESIGNED USING ASCE7, FBC1609.1.1 AND MUST BE DONE BY A | | DESIGN PROFESSIONAL. DOCUMENTS PREPARED BY AN ENGINEER | | AND SUBMITTED FOR PUBLIC RECORD ARE TO BE SIGNED SEALED | | ORIGINALS FAC61G15-23.002. | | | | ____2.PROVIDE A COPY OF THE CONDO ASSOCIATION | | APPROVAL. | | | | _XX_3.COMPLETE THE ATTACHED INSTALLATION SCHEDULE | | OR PROVIDE ALL INFORMATION TO SHOW CODE COMPLIANCE IN | | ANOTHER FORMAT. | | | | ____4.FLORIDA STATE OR LOCAL PRODUCT APPROVAL | | REQUIRED, FAC9B72, WWW.FLORIDABUILDING.ORG. | | | | ____5.ON THE PRODUCT APPROVAL, MARK WHICH DETAILS | | APPLY TO THIS JOB.PLEASE USE INK RATHER THAN A | | HIGHLIGHTER. | | | | ____6.SHOW THE EMERGENCY MEANS OF ESCAPE, FBC | | R310. | | | | _XX_7.PROVIDE A FLOOR PLAN SHOWING WHERE THE | | SHUTTERS WILL BE INSTALLED AND PANEL SIZES WHICH | | CORRELATES WITH THE INSTALLATION SCHEDULE, ITEM 3 | | ABOVE. | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2007-10-29 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-10-29 |
Time |
16:10 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-10-29 |
Time |
16:10 |
Sent To |
B |
|
Notes |
2007-10-29 16:10:50 | TO "SHILL' DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2007-09-28 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-09-28 |
Time |
10:37 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-09-28 |
Time |
10:37 |
Sent To |
B |
|
Notes |
2007-09-28 10:37:49 | TO "SHILL" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2007-09-12 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-09-12 |
Time |
15:02 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-09-12 |
Time |
15:02 |
Sent To |
B |
|
Notes |
2007-09-12 15:03:09 | TO "SHILL" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2007-08-31 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-08-31 |
Time |
12:36 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-08-31 |
Time |
12:36 |
Sent To |
B |
|
Notes |
2007-08-31 12:36:20 | TO "SHILL" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2007-07-13 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-07-13 |
Time |
14:25 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-06-27 |
Time |
15:01 |
Sent To |
|
|
Notes |
2007-06-27 15:01:55 | TO "MISC" BOX#1 |
|
|