Plan Review Details - Permit 07060912
Plan Review Stops For Permit 07060912
Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2007-11-05 Cont ID  
Sent By shill Date 2007-11-05 Time 18:32 Rev Time 0.00
Received By shill Date 2007-11-05 Time 18:32 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status F Date 2007-10-02 Cont ID  
Sent By shill Date 2007-10-02 Time 16:26 Rev Time 0.00
Received By shill Date 2007-10-02 Time 16:26 Sent To  
Notes
2007-10-02 16:31:42****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC*
 CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 FAC
 FLORIDA ADMINISTRATIVE CODE
 FSFLORIDA STATUTE
  
 FROM PREVIOUS LIST:
  
 1.)THE FIRST COMMENT LIST REQUESTED THAT YOU SHOW HOW
 EGRESS IS AFFECTED.YOU ARE BLOCKING THREE DOORS,
 INCLUDING THE MAIN ENTRY DOOR.YOU CANNOT BLOCK A
 REQUIRED MEANS OF EGRESS WITH HURRICANE SHUTTERS.
 PLEASE SEE FBC CHAPTER 10, PARTICULARLY FBC1001.4
 (CANNOT REDUCE THE REQUIRED MEANS OF EGRESS), FBC1007.1
 AND FBC11, FBC1008 (DOORS).PROVIDE A LIFE SAFETY PLAN
 INCLUDING FLOOR PLAN, PATH OF TRAVEL, OCCUPANCY
 CLASSIFICATION FBC3, OCCUPANT LOAD FBC10.YOU CANNOT
 BLOCK THE MAIN ENTRANCE.IT IS NOT CLEAR IF THE OTHER
 TWO DOORS ARE REQUIRED MEANS OF EGRESS OR ACCESSIBLE
 MEANS OF EGRESS.PROVIDE PLANS WHICH SHOW CODE
 COMPLIANCE, TO BE PREPARED BY A DESIGN PROFESSIONAL.
  
 COMMENT NOT ADDRESSED.SEE THE FOLLOWING CODES, ALL
 WHICH PROHIBIT BLOCKING THE REQUIRED EXITS:FBC1001.2
 (UNLAWFUL TO ALTER A BUILDING THAT WILL REDUCE THE
 NUMBER OF EXITS OR THE CAPACITY OF THE MEANS OF EGRESS
 TO LESS THAN REQUIRED), FBC1003.6 (PATH OF EGRESS
 TRAVEL SHALL NOT BE INTERRUPTED BY ANY BUILDING ELEMENT
 OTHER THAN A MEANS OF EGRESS COMPONENT).SOMEONE WROTE
 "EGRESS IS PROVIDED BY SHUTTERS THAT CAN BE DEPLOYED
 AND REMOVED FROM THE NSIDE OR OUTSIDE."THERE IS
 PROVISION FOR THIS IN RESIDENTIAL CODE, BUT NOT IN
 FLORIDA BUILDING CODE.IF YOU FEEL THAT I AM
 INCORRECT, PROVIDE THE CODE SECTION WHICH ALLOWS THIS.
  
  
 DO NOT RESUBMIT WITHOUT THE REQUIRED LIFE SAFETY PLAN
 SHOWING ALL REQUIRED EXIT DOORS UNLESS YOUR SHUTTER
 PLAN IS TO INCLUDE WINDOWS ONLY.
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2007-09-13 Cont ID  
Sent By shill Date 2007-09-13 Time 09:49 Rev Time 0.00
Received By shill Date 2007-09-13 Time 09:49 Sent To  
Notes
2007-09-13 09:55:01****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC*
 CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
 FACFLORIDA ADMINISTRATIVE CODE
 FSFLORIDA STATUTE
  
 1.)THE FIRST COMMENT LIST REQUESTED THAT YOU SHOW HOW
 EGRESS IS AFFECTED.YOU ARE BLOCKING THREE DOORS,
 INCLUDING THE MAIN ENTRY DOOR.YOU CANNOT BLOCK A
 REQUIRED MEANS OF EGRESS WITH HURRICANE SHUTTERS.
 PLEASE SEE FBC CHAPTER 10, PARTICULARLY FBC1001.4
 (CANNOT REDUCE THE REQUIRED MEANS OF EGRESS), FBC1007.1
 AND FBC11, FBC1008 (DOORS).PROVIDE A LIFE SAFETY PLAN
 INCLUDING FLOOR PLAN, PATH OF TRAVEL, OCCUPANCY
 CLASSIFICATION FBC3, OCCUPANT LOAD FBC10.YOU CANNOT
 BLOCK THE MAIN ENTRANCE.IT IS NOT CLEAR IF THE OTHER
 TWO DOORS ARE REQUIRED MEANS OF EGRESS OR ACCESSIBLE
 MEANS OF EGRESS.PROVIDE PLANS WHICH SHOW CODE
 COMPLIANCE, TO BE PREPARED BY A DESIGN PROFESSIONAL.
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2007-09-05 Cont ID  
Sent By shill Date 2007-09-05 Time 17:53 Rev Time 0.00
Received By shill Date 2007-09-05 Time 17:53 Sent To  
Notes
2007-09-05 17:53:31****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC*
 CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
  
 FAC FLORIDA ADMINISTRATIVE CODE
 FSFLORIDA STATUTE
  
 1.)NO DOORS WERE SHOWN ON THE PLAN.PLEASE SHOW HOW
 EGRESS WILL BE AFFTECTED, FBC10.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-07-13 Cont ID  
Sent By shill Date 2007-07-13 Time 14:25 Rev Time 0.00
Received By shill Date 2007-07-13 Time 14:24 Sent To  
Notes
2007-07-13 14:25:47****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2004
 FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
  
 SHUTTER PERMIT APPLICATION, ONLY CHECKED ITEMS APPLY
  
 ____1.PROVIDE BUILDING HEIGHT ON THE PLAN.DESIGN
 PRESSURES FOR BUILDINGS OVER 60FEET ARE REQUIRED TO BE
 DESIGNED USING ASCE7, FBC1609.1.1 AND MUST BE DONE BY A
 DESIGN PROFESSIONAL. DOCUMENTS PREPARED BY AN ENGINEER
 AND SUBMITTED FOR PUBLIC RECORD ARE TO BE SIGNED SEALED
 ORIGINALS FAC61G15-23.002.
  
 ____2.PROVIDE A COPY OF THE CONDO ASSOCIATION
 APPROVAL.
  
 _XX_3.COMPLETE THE ATTACHED INSTALLATION SCHEDULE
 OR PROVIDE ALL INFORMATION TO SHOW CODE COMPLIANCE IN
 ANOTHER FORMAT.
  
 ____4.FLORIDA STATE OR LOCAL PRODUCT APPROVAL
 REQUIRED, FAC9B72, WWW.FLORIDABUILDING.ORG.
  
 ____5.ON THE PRODUCT APPROVAL, MARK WHICH DETAILS
 APPLY TO THIS JOB.PLEASE USE INK RATHER THAN A
 HIGHLIGHTER.
  
 ____6.SHOW THE EMERGENCY MEANS OF ESCAPE, FBC
 R310.
  
 _XX_7.PROVIDE A FLOOR PLAN SHOWING WHERE THE
 SHUTTERS WILL BE INSTALLED AND PANEL SIZES WHICH
 CORRELATES WITH THE INSTALLATION SCHEDULE, ITEM 3
 ABOVE.
  

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2007-10-29 Cont ID  
Sent By adarroug Date 2007-10-29 Time 16:10 Rev Time 0.00
Received By adarroug Date 2007-10-29 Time 16:10 Sent To B
Notes
2007-10-29 16:10:50TO "SHILL' DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2007-09-28 Cont ID  
Sent By adarroug Date 2007-09-28 Time 10:37 Rev Time 0.00
Received By adarroug Date 2007-09-28 Time 10:37 Sent To B
Notes
2007-09-28 10:37:49TO "SHILL" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2007-09-12 Cont ID  
Sent By adarroug Date 2007-09-12 Time 15:02 Rev Time 0.00
Received By adarroug Date 2007-09-12 Time 15:02 Sent To B
Notes
2007-09-12 15:03:09TO "SHILL" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-08-31 Cont ID  
Sent By adarroug Date 2007-08-31 Time 12:36 Rev Time 0.00
Received By adarroug Date 2007-08-31 Time 12:36 Sent To B
Notes
2007-08-31 12:36:20TO "SHILL" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-07-13 Cont ID  
Sent By shill Date 2007-07-13 Time 14:25 Rev Time 0.00
Received By shill Date 2007-06-27 Time 15:01 Sent To  
Notes
2007-06-27 15:01:55TO "MISC" BOX#1


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved