Plan Review Details - Permit 07060790
Plan Review Stops For Permit 07060790
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2007-08-21 Cont ID  
Sent By shill Date 2007-08-21 Time 18:47 Rev Time 0.00
Received By shill Date 2007-08-21 Time 18:47 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2007-07-31 Cont ID  
Sent By shill Date 2007-07-31 Time 14:34 Rev Time 0.00
Received By shill Date 2007-07-31 Time 14:34 Sent To  
Notes
2007-07-31 14:35:20****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC*
 CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 FAC
 FLORIDA ADMINISTRATIVE CODE
 FSFLORIDA STATUTE
  
 1.)SEE OPENING 5.FBC R TABLE 301.2(2) AND 301.2(3)
 REQUIRE A DESIGN PRESSURE OF -38.2 FOR 10SF, MULTIPLIED
 BY 1.29 FOR MRH OF 20', EXPOSURE C, FOR A DESIGN
 PRESSURE OF -49.28.YOU ARE DESIGNING TO -45PSF.YOUR
 PRODUCT APPROVAL REQUIRES USE OF THE -77PSF ROW FOR
 PRESSURES OVER -47.2, SO THE ANCHOR SPACING OF 6"/6" IS
 NOT COMPLIANT FOR THIS OPENING.
  
 CHECK ALL OPENINGS.THIS COMMENT APPLIES TO OTHER
 OPENINGS.YOU MUST DESIGN USING EITHER FBC TABLE
 R301.2.1(2) AND (3), FBC R 301, OR WITH AN ARCHITECT OR
 ENGINEER USING ASCE7-02.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-07-10 Cont ID  
Sent By shill Date 2007-07-10 Time 16:21 Rev Time 0.00
Received By shill Date 2007-07-10 Time 16:21 Sent To  
Notes
2007-07-10 16:23:20****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
 FAC FLORIDA ADMINISTRATIVE CODE
 FSFLORIDA STATUTE
  
  
 1.)PLEASE EXPLAIN WHY THE SPAN IS THE SAME AS THE
 OPENING HEIGHT WITH A 3" EDGE DISTANCE.IF THE SPAN IS
 AFFECTED BY OVER 2" FROM THIS COMMENT, PLEASE REVISE
 ANCHOR SPACING AS YOU HAVE USED THE 6' CHART (OPENINGS
 ARE 70").

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2007-08-07 Cont ID  
Sent By btrobaug Date 2007-08-07 Time 14:53 Rev Time 0.00
Received By btrobaug Date 2007-08-07 Time 14:53 Sent To B
Notes
2007-08-07 14:55:05 
 SAMANTHA./WRT.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-07-18 Cont ID  
Sent By adarroug Date 2007-07-18 Time 14:15 Rev Time 0.00
Received By adarroug Date 2007-07-18 Time 14:15 Sent To B
Notes
2007-07-18 14:15:41TO "SHILL' DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-06-26 Cont ID  
Sent By adarroug Date 2007-06-26 Time 11:43 Rev Time 0.00
Received By adarroug Date 2007-06-26 Time 11:43 Sent To B
Notes
2007-06-26 11:44:07TO "MISC" BOX#1


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved