Plan Review Details - Permit 07060790
Plan Review Stops For Permit 07060790 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2007-08-21 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-08-21 |
Time |
18:47 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-08-21 |
Time |
18:47 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2007-07-31 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-07-31 |
Time |
14:34 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-07-31 |
Time |
14:34 |
Sent To |
|
|
Notes |
2007-07-31 14:35:20 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBCFLORIDA BUILDING CODE 2004 | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | CODE | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC* | | CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 FAC | | FLORIDA ADMINISTRATIVE CODE | | FSFLORIDA STATUTE | | | | 1.)SEE OPENING 5.FBC R TABLE 301.2(2) AND 301.2(3) | | REQUIRE A DESIGN PRESSURE OF -38.2 FOR 10SF, MULTIPLIED | | BY 1.29 FOR MRH OF 20', EXPOSURE C, FOR A DESIGN | | PRESSURE OF -49.28.YOU ARE DESIGNING TO -45PSF.YOUR | | PRODUCT APPROVAL REQUIRES USE OF THE -77PSF ROW FOR | | PRESSURES OVER -47.2, SO THE ANCHOR SPACING OF 6"/6" IS | | NOT COMPLIANT FOR THIS OPENING. | | | | CHECK ALL OPENINGS.THIS COMMENT APPLIES TO OTHER | | OPENINGS.YOU MUST DESIGN USING EITHER FBC TABLE | | R301.2.1(2) AND (3), FBC R 301, OR WITH AN ARCHITECT OR | | ENGINEER USING ASCE7-02. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2007-07-10 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-07-10 |
Time |
16:21 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-07-10 |
Time |
16:21 |
Sent To |
|
|
Notes |
2007-07-10 16:23:20 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBCFLORIDA BUILDING CODE 2004 | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | CODE | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | FAC FLORIDA ADMINISTRATIVE CODE | | FSFLORIDA STATUTE | | | | | | 1.)PLEASE EXPLAIN WHY THE SPAN IS THE SAME AS THE | | OPENING HEIGHT WITH A 3" EDGE DISTANCE.IF THE SPAN IS | | AFFECTED BY OVER 2" FROM THIS COMMENT, PLEASE REVISE | | ANCHOR SPACING AS YOU HAVE USED THE 6' CHART (OPENINGS | | ARE 70"). |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2007-08-07 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2007-08-07 |
Time |
14:53 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2007-08-07 |
Time |
14:53 |
Sent To |
B |
|
Notes |
2007-08-07 14:55:05 | | | SAMANTHA./WRT. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2007-07-18 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-07-18 |
Time |
14:15 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-07-18 |
Time |
14:15 |
Sent To |
B |
|
Notes |
2007-07-18 14:15:41 | TO "SHILL' DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2007-06-26 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-06-26 |
Time |
11:43 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-06-26 |
Time |
11:43 |
Sent To |
B |
|
Notes |
2007-06-26 11:44:07 | TO "MISC" BOX#1 |
|
|
|