Plan Review Details - Permit 07060773
Plan Review Stops For Permit 07060773
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2007-08-15 Cont ID  
Sent By mjacobs Date 2007-08-15 Time 15:26 Rev Time 0.00
Received By mjacobs Date 2007-08-15 Time 15:26 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-07-13 Cont ID  
Sent By mjacobs Date 2007-07-13 Time 17:09 Rev Time 0.00
Received By mjacobs Date 2007-07-13 Time 11:02 Sent To  
Notes
2007-07-13 14:50:34BUILDING PLAN REVIEW
 PERMIT: 07060773
 ADD: 422 SUNSET ROAD
 CONT: BURKHART CONST
 TEL: (561)659- 1400
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2006 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW 1ST
 ACTION: DENIED
  
 1)--- VERY IMPORTANT STATEMENT ---
 PLEASE DO NOT IGNORE!
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH
 A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE
 SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE
 FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR
 YOUR ANTICIPATED COOPERATION.
  
 2)THE BREAK ROOM SINK SHALL MEET THE REQUIREMENTS OF
 FBC. SEC, 11-4.24 -11-4.24.7
  
 3)11-4.1.1(12) STORAGE , SHELVING AND DISPLAY
 UNITS.
 (A)IF FIXED OR BUILT-IN STORAGE FACILITIES SUCH AS
 CABINETS, SHELVES , CLOSETS, AND DRAWERS ARE PROVIDED
 IN ACCESSIBLE SPACES, AT LEAST ONE OF EACH TYPE
 PROVIDED SHALL CONTAIN STORAGE SPACE COMPLYING WITH
 SECTION 11-4.25 . ADDITIONAL STORAGE MAY BE PROVIDED
 OUTSIDE OF THE DIMENSIONS REQUIRED BY SECTION 11-4.25
 .
  
 (B) SHELVES OR DISPLAY UNITS ALLOWING SELF-SERVICE
 BY CUSTOMERS IN MERCANTILE OCCUPANCIES SHALL BE LOCATED
 ON AN ACCESSIBLE ROUTE COMPLYING WITH SECTION 11-4.3 .
 REQUIREMENTS FOR ACCESSIBLE REACH RANGE DO NOT APPLY.
  
 4)THE DESCRIPTION ON THE APPLICATION SHALL REFLECT
 THE PROJECT IN DETAIL. THE STATEMENT/ DESCRIPTION ON
 THE APPLICATION FORM NEED TO BE ADJUSTED TO SHOW THE
 ACTURAL WORK.
  
 5)THE CEILING SUPPORT IS PARTIALY SHOWN ON THE SHEET
 S-1. STATE THE SPACING OF THE CEILING ON THE PLANS
 CLEARLY. AN LEGEND FOR THE ABBREVATIONS IS ALSO
 REQUIRED.
  
 6)IS THE STORAGE ROOM #101 CEILING THE SAME AS THE
 OTHER AREA?
  
 7)SUBMIT THE SHOP DRAWINGS FOR THE SUSPENDED CEILING
 SYSTEM AS STATED ON SHEET A-2.
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER
 805-6726
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2007-09-28 Cont ID  
Sent By btrobaug Date 2007-09-28 Time 17:09 Rev Time 0.00
Received By btrobaug Date 2007-09-28 Time 16:30 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2007-08-17 Cont ID  
Sent By btrobaug Date 2007-08-17 Time 16:05 Rev Time 0.00
Received By btrobaug Date 2007-08-17 Time 15:24 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2007-06-29 Cont ID  
Sent By btrobaug Date 2007-06-29 Time 15:04 Rev Time 0.00
Received By btrobaug Date 2007-06-29 Time 14:11 Sent To  
Notes
2007-06-29 15:04:36 
  
  
 NONCOMPLIANT
  
 PLEASE MAKE THE FOLLOWING CORRECTIONS FOR CODE
 COMPLIANCE AND RESUBMIT FOR REVIEW.
  
 1} THE EMERGENCY BATTERY PACK MUST BE ON CIRCUIT P1-15
 TO COMPLY WITH 700-12(F)(4) "THE BRANCH CIRCUIT FEEDING
 THE UNIT EQUIPMENT SHALL BE THE SAME BRANCH CIRCUIT AS
 THAT SERVING THE NORMAL LIGHTING IN THE AREA AND
 CONNECTED AHEAD OF ANY LOCAL SWITCHES."
  
 2} CIRCUITS 67, 69,AND 73ON THE PANEL SCHEDULE DO
 NOT CORRELATE WITH THE EQUIPMENT SHOWN ON THE PLAN,
 SHEET E-1.1.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status N Date 2007-07-09 Cont ID  
Sent By mawillia Date 2007-07-09 Time 16:46 Rev Time 0.00
Received By mawillia Date 2007-07-09 Time 16:40 Sent To  
Notes
2007-07-09 16:46:16*****APPROVED*****
  
  
 THE SCOPE OF WORK APPEARS TO NOT IMPACT LIFE SAFETY
 CONCERNS

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2007-09-28 Cont ID  
Sent By btrobaug Date 2007-09-28 Time 16:30 Rev Time 0.00
Received By btrobaug Date 2007-09-28 Time 16:30 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-07-28 Cont ID  
Sent By adarroug Date 2007-07-28 Time 14:21 Rev Time 0.00
Received By adarroug Date 2007-07-28 Time 14:21 Sent To  
Notes
2007-08-08 19:06:17TO BOB BOARD #9
2007-07-28 14:22:13WAITING FOR "BOB"

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-07-13 Cont ID  
Sent By adarroug Date 2007-07-13 Time 14:21 Rev Time 0.00
Received By adarroug Date 2007-06-25 Time 15:22 Sent To  
Notes
2007-06-26 11:25:00TO "BOB"#10
2007-06-25 15:22:52WAITING FOR "BOB"

Review Stop P PLUMBING
Rev No 2 Status P Date 2007-08-15 Cont ID  
Sent By jleech Date 2007-08-15 Time 12:05 Rev Time 0.00
Received By jleech Date 2007-08-15 Time 12:05 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2007-07-09 Cont ID  
Sent By jleech Date 2007-07-09 Time 07:51 Rev Time 0.00
Received By jleech Date 2007-07-09 Time 07:34 Sent To  
Notes
2007-07-09 08:27:35DENIED;
 1. FLOOR DRAIN SHOULD BE A WASTE RECEPTOR WITH AN
 INTERIOR STRAINER. FBC-2004 PLUMBING SECTIONS 802.2 AND
 802.3.
 2. WATER HAMMER ARRESTOR IS REQUIRED ON HOT WATER TO
 THE DISHWASHER. SECTION 604.9
 3. BREAK SINK TO MEET ACCESSIBILITY CODE SECTIONS
 11-4.24.1 THRU 11-4.23.7
 A) 11-4.24.3 THE FRONT OF CABINET TO BE
 OPEN FOR KNEE CLEARANCE OF 19" UNDER SINK. ALSO THE
 GARBAGE DISPOSAL MUST BE OFF SET OR DELETED.
 B) 11-4.24.4 DEPTH OF SINK TO BE A MAXIMUM
 OF 6 1/2" DEEP. ( SHOW ON PLANS)
 C) EXPOSED PIPES TO BE INSULATED.
 PLUMBING PLAN REVIEW BY:
 JOHN LEECH
 805-6695

Review Stop Z ZONING
Rev No 1 Status N Date 2007-08-10 Cont ID  
Sent By choops Date 2007-08-10 Time 08:35 Rev Time 0.00
Received By choops Date 2007-08-10 Time 08:35 Sent To  
Notes
2007-08-10 08:36:07*VALUE OF PROPOSED WORK DOES NOT EXCEED 50% OF THE
 IMPROVEMENT VALUE.


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved