Plan Review Details - Permit 07060741
Plan Review Stops For Permit 07060741
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2007-11-01 Cont ID  
Sent By mjacobs Date 2007-11-01 Time 13:40 Rev Time 0.00
Received By mjacobs Date 2007-10-05 Time 06:46 Sent To E
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2007-08-01 Cont ID  
Sent By mjacobs Date 2007-08-01 Time 11:05 Rev Time 0.00
Received By mjacobs Date 2007-08-01 Time 09:44 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-07-05 Cont ID  
Sent By mjacobs Date 2007-07-05 Time 08:38 Rev Time 0.00
Received By mjacobs Date 2007-07-03 Time 08:39 Sent To  
Notes
2007-07-05 08:38:16BUILDING PLAN REVIEW
 PERMIT: 07060741
 ADD: 400 N FLAGLER DR.
 CONT: BRANCH CONSTRUCTION INC.
 TEL: (561)833-6206.
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2006 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW 1ST
 ACTION: DENIED
  
 1)--- VERY IMPORTANT STATEMENT ---
 PLEASE DO NOT IGNORE!
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH
 A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE
 SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE
 FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR
 YOUR ANTICIPATED COOPERATION.
  
 2)FBC:1203.4.2.1 BATHROOMS .
 ROOMS CONTAINING BATHTUBS, SHOWERS, SPAS AND SIMILAR
 BATHING FIXTURES SHALL BE MECHANICALLY VENTILATED IN
 ACCORDANCE WITH THE FLORIDA BUILDING CODE, MECHANICAL
 .
  
  
 3)FBC: TABLE 803.3 MINIMUM INTERIOR FINISH
 CLASSIFICATION; PROVIDE INFORMATION BASED ON INTERIOR
 FINISH REQUIREMENTS BASED ON OCCUPANCY.
  
 4)1207.3THE FLOOR/CEILING ASSEMBLY SHALL HAVE AND
 IMPACE INSULATION CLASS (IIC) RATING OF NOT LESS THAN
 50 (45 IF FIELD TESTED) WITH ASTM E 492. PROVIDE THE
 INFORMATION MEETING THIS REQUIREMENTS. BE SPECIFIC.
  
 5)WPB AMENDMENTS 106.1.3THE BUILDING OFFICIAL MAY
 ESTABLISH THROUGH DEPARTMENTAL POLICY, STANDARDS FOR
 PLANS AND SPECIFICATIONS, IN ORDER TO PROVIDE
 CONFORMITY TO ITS RECORD RETENTION PROGRAM.PROVIDE A
 WALL DETAIL DRAWING OF EACH NEW WALL AND THE INFILLS
 WALLS INDICATING ALL MATERIALS.
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER
 805-6726
  

Review Stop E ELECTRICAL
Rev No 5 Status P Date 2007-11-16 Cont ID  
Sent By btrobaug Date 2007-11-16 Time 10:19 Rev Time 0.00
Received By btrobaug Date 2007-11-15 Time 07:26 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 4 Status F Date 2007-11-01 Cont ID  
Sent By btrobaug Date 2007-11-01 Time 16:24 Rev Time 0.00
Received By btrobaug Date 2007-11-01 Time 15:09 Sent To B
Notes
2007-11-01 16:23:59 
  
  
 REVISION DENIED
  
 THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES:
  
 THE 2004 FLORIDA BUILDING CODE, 2006 REVISIONS, 2004
 RESIDENTIAL BUILDING CODE, 2005 NEC, NFPA-72 2002,
 NFPA-101 2003, 2004 FBC AS AMENDED, CHAPTER 1.AND FOUND
 NONCOMPLIANT WITH THE FOLLOWING:
  
 SHEET E1
  
 1} THE RECEPTACLES IN THE LAUNDRY ARE CIRCUITED WITH
 THE SMALL APPLIANCE CIRCUIT IN THE BREAKFAST NOOK IN
 VIOLATION OF 210.52(B)(2).
  
 2} THE RECEPTACLE IN THE DRESSING ROOM IS ON THE BATH
 CIRCUIT IN VIOLATION OF 210.11(C)(3).
  
 3} THE SMOKE DETECTORS MUST BE ON AN AFCI CIRCUIT PER
 210.12. THEY ARE SHOWN ON A CIRCUIT THAT APPEARS TO BE
 ON A PROGRAMMABLE SWITCH CIRCUIT. PLEASE CLARIFY.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718
 [email protected]

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2007-08-10 Cont ID  
Sent By btrobaug Date 2007-08-10 Time 13:09 Rev Time 0.00
Received By btrobaug Date 2007-08-10 Time 12:53 Sent To M
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2007-08-06 Cont ID  
Sent By btrobaug Date 2007-07-30 Time 07:36 Rev Time 0.00
Received By btrobaug Date 2007-07-30 Time 06:49 Sent To  
Notes
2007-07-30 07:35:09 
  
  
 NONCOMPLIANT
  
 PLEASE MAKE THE FOLLOWING CORRECTIONS FOR CODE
 COMPLIANCE AND RESUBMIT FOR REVIEW.
  
 1} THE HEAT LOAD AND A/C LOAD ARE BOTH LISTED AS
 10,000W IN THE CALCULATIONS, BUT SHOWN ON 30 AND 20 AMP
 BRAKERS ON THE PANEL SCHEDULE. SEE 220.83 FOR OPTIONAL
 EXISTING DWELLING CALCULATIONS. FIELD VERIFY THE A/C
 SYSTEM RATINGS.
  
 2} THE ICE MACHINE AT THE BAR IS ON A SMALL APPLIANCE
 CIRCUIT IN VIOLATION OF 210.52(B)(2).
  
 3} THE BREAKFAST NOOK MUST BE ON A SMALL APPLIANCE
 CIRCUIT PER 210.52(B)(1). THE LIGHTS ON CIRCUIT 28B ARE
 ALSO IN VIOLATION OF 210.52(B)(2).
  
 PLEASE REMOVE ALL OLD OR VOIDED SHEETS AND REPLACE WITH
 CORRECTED ONES WHEN RESUBMITTING. INCLUDE THEM
 SEPARATELY TO EXPEDITE THE REVIEW PROCESS.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2007-06-29 Cont ID  
Sent By btrobaug Date 2007-06-29 Time 10:55 Rev Time 0.00
Received By btrobaug Date 2007-06-28 Time 07:03 Sent To M
Notes
2007-06-28 08:21:28 
  
 NONCOMPLIANT
  
 PLEASE MAKE THE FOLLOWING CORRECTIONS FOR CODE
 COMPLIANCE AND RESUBMIT FOR REVIEW.
  
 1} PLEASE PROVIDE MANUFACTIRERS SPECIFICATION FOR THE
 STEAM GENERATOR TO BE INSTALLED SO THE LOAD CALCULATION
 AND LISTING CAN BE VERIFIED.
  
 2} THE KITCHEN AND BREAKFAST ROOM CIRCUITS DO NOT
 COMPLY WITH 210.52(B)(1), 20 AMP.CIRCUIT 26A MUST ALSO
 BE 20 AMP.
  
 3} THE WASHER/DRYER STACKED UNIT ARE LISTED SEPARATELY
 ON THE PANEL SCHEDULE, PLEASE CLARIFY.
  
 4} THE WHIRPOOL MUST COMPLY WITH 680.7, GFCI PROTECTED
 CIRCUIT.
  
 5} THE SMOKE ALARMS ARE ON DIFFERENT CIRCUITS
 THROUGHOUT THE RESIDENCE AND DO NOT COMPLY WITH THE
 REQUIREMENT TO INTERCONNECT, R313.1 FBC, RESIDENTIAL.
 ALSO SEE THE DEFINITION OF "SMOKE DETECTORS" 11.8.2.1
 NFPA-72, CLARIFY IF USING DETECTORS OR ALARMS, TO AVOID
 CONFUSION IN THE FIELD.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2007-11-01 Cont ID  
Sent By mawillia Date 2007-11-01 Time 17:21 Rev Time 0.00
Received By mawillia Date 2007-11-01 Time 17:09 Sent To  
Notes
2007-11-01 17:20:58*****APPROVED, REVISION DATED 10/25/07*****
  
  
 REVISED PLAN SHEET E1 STAMPED, INITIALED, AND DATED.

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2007-08-06 Cont ID  
Sent By mwennerg Date 2007-08-06 Time 14:22 Rev Time 0.00
Received By mwennerg Date 2007-08-06 Time 14:22 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2007-07-05 Cont ID  
Sent By mwennerg Date 2007-07-05 Time 11:17 Rev Time 0.00
Received By mwennerg Date 2007-07-05 Time 11:17 Sent To  
Notes
2007-07-05 11:20:14***DENIED***
  
 1) PLEASE SEE ELECTRICAL COMMENT #5 REF: SMOKE ALARM
 REQUIREMENTS AND DEFINITION.
  
 2) CONSTRUCTION, ALTERATION AND DEMOLITION TO COMPLY
 WITH NFPA 241.
  
 3) WILL WORK IMPACT FIRE SPRINKLER OR FIRE ALARM
 EQUIPMENT?
  
  
 MIKE WENNERGREN, ASSISTANT FIRE MARSHAL
 FIRE PLAN REVIEW
 FIRE PREVENTION (561) 804-4756

Review Stop I INCOMING/PROCESSING
Rev No 8 Status N Date 2007-11-08 Cont ID  
Sent By adarroug Date 2007-11-08 Time 15:24 Rev Time 0.00
Received By adarroug Date 2007-11-08 Time 15:24 Sent To E
Notes
2007-11-08 15:24:53TO "BTROBAUG' DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2007-10-31 Cont ID  
Sent By adarroug Date 2007-10-31 Time 14:57 Rev Time 0.00
Received By adarroug Date 2007-10-31 Time 14:57 Sent To  
Notes
2007-10-31 14:58:33WAITING FOR "BOB"

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2007-10-02 Cont ID  
Sent By adarroug Date 2007-10-02 Time 09:46 Rev Time 0.00
Received By adarroug Date 2007-10-02 Time 09:46 Sent To B
Notes
2007-10-02 09:47:00TO "MJACOBS" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2007-09-28 Cont ID  
Sent By adarroug Date 2007-09-28 Time 16:16 Rev Time 0.00
Received By adarroug Date 2007-09-28 Time 16:16 Sent To M
Notes
2007-09-28 16:17:15TO "M" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2007-09-13 Cont ID  
Sent By adarroug Date 2007-09-13 Time 10:35 Rev Time 0.00
Received By adarroug Date 2007-09-13 Time 10:35 Sent To M
Notes
2007-09-13 10:35:17TO "M" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2007-08-08 Cont ID  
Sent By dpalmer Date 2007-08-08 Time 18:27 Rev Time 0.00
Received By dpalmer Date 2007-08-08 Time 18:27 Sent To  
Notes
2007-08-08 18:28:08WAITING FOR BOB BOARD.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-07-16 Cont ID  
Sent By adarroug Date 2007-07-16 Time 16:01 Rev Time 0.00
Received By adarroug Date 2007-07-16 Time 16:01 Sent To  
Notes
2007-07-19 15:51:33TO "BOB"#14
2007-07-16 16:02:03WAITING FOR "BOB"

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-07-06 Cont ID  
Sent By jleech Date 2007-07-06 Time 08:42 Rev Time 0.00
Received By jleech Date 2007-06-24 Time 15:37 Sent To  
Notes
2007-06-25 13:08:38TO "BOB"#5
2007-06-24 15:38:17WAITING FOR "BOB"

Review Stop M MECHANICAL (A/C)
Rev No 5 Status P Date 2007-10-12 Cont ID  
Sent By tgordon Date 2007-10-12 Time 11:44 Rev Time 0.30
Received By tgordon Date 2007-10-12 Time 11:44 Sent To  
Notes
2007-10-12 11:44:59REVISION TO MECH.PLANS PAGE AC

Review Stop M MECHANICAL (A/C)
Rev No 4 Status F Date 2007-09-14 Cont ID  
Sent By tgordon Date 2007-09-14 Time 09:36 Rev Time 0.30
Received By tgordon Date 2007-09-14 Time 09:36 Sent To  
Notes
2007-09-14 09:45:41PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE &
 REFERENCED CODES WITH 05, 06 REVISIONS, CITY OF WEST
 PALM BEACH AMENDMENTS TO CHAPTER 1 (WPB), FLORIDA
 ADMINISTRATIVE CODE (FAC), AND FLORIDA STATUTES (FS).
  
 *** DENIED ***
 1) THE KITCHEN HOOD VENT IS GOING TO THE KITCHEN SINK,
 PLEASE CORRECT.
  
 2) SHOW SUPPLY AIR CFM'S AT ALL SUPPLY AIR GRILLS (SEE
 YELLOW HIGH LIGHT ON MECHANICAL PLAN).
  
 3) SHOW CFM'S AT BATHROOM EXHAUST FANS, SEE RES.
 M1506.3.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729
 E-MAIL; [email protected]

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2007-08-10 Cont ID  
Sent By tgordon Date 2007-08-10 Time 14:32 Rev Time 0.25
Received By tgordon Date 2007-08-10 Time 14:32 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2007-08-07 Cont ID  
Sent By tgordon Date 2007-08-07 Time 16:22 Rev Time 0.30
Received By tgordon Date 2007-08-07 Time 16:22 Sent To  
Notes
2007-08-07 16:37:28PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE &
 REFERENCED CODES WITH 2005, 2006 REVISIONS, AND CHAPTER
 1 CITY OF WEST PALM BEACH AMENDMENTS.
  
 *** DENIED ***
 1) MECHANICAL PLANS NEED CASSIDY A/C INFORMATION IN THE
 TITLE BLOCK ALL INFORMATION, DRAWINGS, SPECIFICATIONS
 AND ACCOMPANYING DATA SHALL BEAR THE PRINTED NAME AND
 SIGNATURE OF THE PERSON RESPONSIBLE FOR THE DESIGN. PER
 2004 FBC, CITY WPB AMEND. 106.1.3.
  
 2) MECHANICAL PLAN SHOWS A LOOPED SUPPLY AIR DUCT AT
 THE AIR HANDLED (SEE YELLOW HIGH LIGHT) PLEASE EXPLAIN
 OR CORRECT.
  
 3) SEE YELLOW HIGH LIGHT ON MECHANICAL PLAN SHOWING
 SUPPLY DUCTS THAT NEED TO BE SIZED.
  
 4) MECHANICAL PLAN STATES "ALL RETURN AIR THROUGH
 LOUVERED DOORS" . DOES THIS APPLY TO THE BEDROOMS AND
 THE POCKET DOOR TO THE LIVING ROOM? IF SO PLEASE STATE
 SO ON MECHANICAL PLAN IF NOT COMPLY WITH 2004 FBC/M
 601.4 BALANCED RETURN AIR.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729
 E-MAIL: [email protected].

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2007-07-05 Cont ID  
Sent By tgordon Date 2007-07-05 Time 10:17 Rev Time 0.30
Received By tgordon Date 2007-07-05 Time 10:17 Sent To  
Notes
2007-07-05 10:27:24*** DENIED ***
 1) PLEASE SUBMIT MECHANICAL PLANS SHOWING HOW THE
 SUPPLY AIR DUCTS, RETURN AIR DUCTS, DRAIN LINE,
 REFRIGERANT LINES OR WATER LINES ARE BEING ALTERED AS A
 RESULT OF RELOCATING THE AIR HANDLER. ALSO PLEASE SHOW
 IF ANY SUPPLY OR RETURN AIR GRILLS ARE BEING
 RELOCATED.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop P PLUMBING
Rev No 3 Status P Date 2007-11-01 Cont ID  
Sent By jleech Date 2007-11-01 Time 14:35 Rev Time 0.00
Received By jleech Date 2007-11-01 Time 14:35 Sent To B
Notes
2007-11-01 14:36:17REVISED PLUMBING SHEET A-1 OK

Review Stop P PLUMBING
Rev No 2 Status P Date 2007-08-06 Cont ID  
Sent By jleech Date 2007-08-06 Time 08:59 Rev Time 0.00
Received By jleech Date 2007-08-06 Time 07:57 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2007-07-06 Cont ID  
Sent By jleech Date 2007-07-06 Time 08:33 Rev Time 0.00
Received By jleech Date 2007-07-06 Time 07:56 Sent To  
Notes
2007-07-06 08:41:35DENIED;
 1. NO DEAD ENDS PERMITED IN THE SANITARY DRAINAGE
 SYSTEM. SEE FBC-2004 PLUMBING SECTION 704.5. ALL
 PLUMBING DEMO SHALL BE DONE BY A LICENSED PLUMBING
 CONTRACTOR, PERMIT AND INSPECTIONS REQUIRED. SANITARY
 TO BE CAPPED WITH APPROVED PLUMBING PARTS.
 2. SUBMIT MANUFACTURE SPECS. FOR STEAM GENERATOR AND
 BACKFLUSH WATER CLOSETS.
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695

Review Stop Z ZONING
Rev No 1 Status N Date 2007-07-19 Cont ID  
Sent By choops Date 2007-07-19 Time 17:52 Rev Time 0.00
Received By choops Date 2007-07-19 Time 17:52 Sent To  
Notes
2007-07-19 17:52:27*VALUE OF PROPOSED WORK DOES NOT EXCEED 50% OF THE
 IMPROVEMENT VALUE.