Plan Review Details - Permit 07060689
Plan Review Stops For Permit 07060689 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2007-08-30 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-08-30 |
Time |
18:58 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-08-30 |
Time |
18:58 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2007-08-03 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-08-03 |
Time |
17:12 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-08-03 |
Time |
17:12 |
Sent To |
|
|
Notes |
2007-08-03 17:16:20 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBCFLORIDA BUILDING CODE 2004 | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | CODE | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | FAC FLORIDA ADMINISTRATIVE CODE | | FSFLORIDA STATUTE | | | | 1.)OPENING 1, YOU STATE SPACING WILL BE 2", MINIMUM | | OF 3" REQUIRED (SEE SHEET 14A OF THE PRODUCT APPROVAL). | | IF THIS IS A FLOOR MOUNT AS STATED, WHY AREN'T YOU | | USING THE ANCHOR SPACING FOR FLOOR/CONCRETE?YOU HAVE | | STATED THAT THIS IS A CBS SUBSTRATE, BUT A FLOOR MOUNT | | REQUIRES A CONCRETE SUBSTRATE. | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2007-07-06 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-07-06 |
Time |
15:13 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-07-06 |
Time |
15:13 |
Sent To |
|
|
Notes |
2007-07-06 15:15:23 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBCFLORIDA BUILDING CODE 2004 | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | CODE | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | FAC FLORIDA ADMINISTRATIVE CODE | | FSFLORIDA STATUTE | | | | 1.)IT IS NOT CLEAR HOW YOU HAVE ARRIVED AT THE SPANS. | | PLEASE CLARIFY HOW THEY CAN ALL BE 12'1" REGARDLESS OF | | OPENING SIZE. | | | | 2.)OPENING 1, 12'1" SPAN, CEILING MOUNT REQUIRES 4 | | 1/2" IF IT HAS A 3 1/2" EDGE DISTANCE, YOU'VE SPECIFIED | | 9".CHECK ALL OPENINGS. | | | | 3.)3" EDGE DISTANCE REQUIRED .86 FACTOR, SEE SHEET | | 14A. | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2007-08-27 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-08-27 |
Time |
15:40 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-08-27 |
Time |
15:40 |
Sent To |
B |
|
Notes |
2007-08-27 15:40:28 | TO "SHILL" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2007-08-02 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-08-02 |
Time |
13:32 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-08-02 |
Time |
13:32 |
Sent To |
B |
|
Notes |
2007-08-02 13:33:05 | TO "SHILL" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2007-07-06 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-07-06 |
Time |
15:15 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-06-22 |
Time |
13:18 |
Sent To |
|
|
Notes |
2007-06-22 13:18:39 | TO "MISC" BOX#1 |
|
|
|
Account Summary | Usage Policy | Privacy Policy