Plan Review Details - Permit 07060660
Plan Review Stops For Permit 07060660
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2007-08-16 Cont ID  
Sent By shill Date 2007-08-16 Time 19:17 Rev Time 0.00
Received By shill Date 2007-08-16 Time 19:17 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2007-08-13 Cont ID  
Sent By shill Date 2007-08-13 Time 08:23 Rev Time 0.00
Received By shill Date 2007-08-13 Time 08:23 Sent To  
Notes
2007-08-13 08:24:01****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
 FAC FLORIDA ADMINISTRATIVE CODE
 FSFLORIDA STATUTE
  
 1.)SHUTTER GLASS SEPARATION ON THE INSTALLATION
 SCHEDULE STATES NA.SEE SHEET 3 OF THE PANEL PRODUCT
 APPROVAL, ALSO SEE CLEAR PANEL PRODUCT APPROVAL.THIS
 IS REQUIRED AND DESIGNED BASED ON POSITIVE DESIGN
 PRESSURE.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2007-07-30 Cont ID  
Sent By shill Date 2007-07-30 Time 11:43 Rev Time 0.00
Received By shill Date 2007-07-30 Time 11:43 Sent To  
Notes
2007-07-30 11:45:14****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2004
 FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL FBC* CITY
 OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
 SHUTTER PERMIT APPLICATION, ONLY CHECKED ITEMS APPLY
  
  
 FROM PREVIOUS LIST:
  
  
 _XX_3.COMPLETE THE ATTACHED INSTALLATION SCHEDULE
 OR PROVIDE ALL INFORMATION TO SHOW CODE COMPLIANCE IN
 ANOTHER FORMAT.SHUTTER MOUNTING CONNECTION TYPE AND
 EDGE DISTANCE WERE NOT INCLUDED IN THE SCHEDULE YOU
 PROVIDED.
  
 THE RESPONSE LETTER STATES "YOU KNOW."PLEASE SEE THE
 BUILDING OFFICIAL'S POLICY REGARDING HURRICANE
 SHUTTERS.ALL INFORMATION TO DETERMINE CODE COMPLIANCE
 IS TO BE INCLUDED ON AN INSTALLATION SCHEDULE TO ASSIST
 WITH PLAN REVIEW AND INSPECTIONS.PLEASE PROVIDE THE
 TWO REQUESTED ITEMS.IF YOU NEED ASSISTANCE, PLEASE
 HAVE THE QUALIFIER CONTACT ME.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-07-06 Cont ID  
Sent By shill Date 2007-07-06 Time 13:57 Rev Time 0.00
Received By shill Date 2007-07-06 Time 13:57 Sent To  
Notes
2007-07-06 13:58:49****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2004
 FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
  
 SHUTTER PERMIT APPLICATION, ONLY CHECKED ITEMS APPLY
  
 ____1.PROVIDE BUILDING HEIGHT ON THE PLAN.DESIGN
 PRESSURES FOR BUILDINGS OVER 60FEET ARE REQUIRED TO BE
 DESIGNED USING ASCE7, FBC1609.1.1 AND MUST BE DONE BY A
 DESIGN PROFESSIONAL. DOCUMENTS PREPARED BY AN ENGINEER
 AND SUBMITTED FOR PUBLIC RECORD ARE TO BE SIGNED SEALED
 ORIGINALS FAC61G15-23.002.
  
 ____2.PROVIDE A COPY OF THE CONDO ASSOCIATION
 APPROVAL.
  
 _XX_3.COMPLETE THE ATTACHED INSTALLATION SCHEDULE
 OR PROVIDE ALL INFORMATION TO SHOW CODE COMPLIANCE IN
 ANOTHER FORMAT.SHUTTER MOUNTING CONNECTION TYPE AND
 EDGE DISTANCE WERE NOT INCLUDED IN THE SCHEDULE YOU
 PROVIDED.
  
 ____4.FLORIDA STATE OR LOCAL PRODUCT APPROVAL
 REQUIRED, FAC9B72, WWW.FLORIDABUILDING.ORG.
  
 ____5.ON THE PRODUCT APPROVAL, MARK WHICH DETAILS
 APPLY TO THIS JOB.PLEASE USE INK RATHER THAN A
 HIGHLIGHTER.
  
 ____6.SHOW THE EMERGENCY MEANS OF ESCAPE, FBC
 R310.
  
 ____7.PROVIDE A FLOOR PLAN SHOWING WHERE THE
 SHUTTERS WILL BE INSTALLED AND PANEL SIZES WHICH
 CORRELATES WITH THE INSTALLATION SCHEDULE, ITEM 3
 ABOVE.
  
 ____8.REVISE EXPOSURE CATEGORY FBC1609.6.2.1(2),
 FBC R301.2.1.4.NOTE THAT THE DEFINITION FOR EXPOSURE
 C HAS CHANGED EFFECTIVE DECEMBER 8, 2006 FBC1609.4, FBC
 R301.2.1.4.
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2007-08-06 Cont ID  
Sent By adarroug Date 2007-08-06 Time 13:32 Rev Time 0.00
Received By adarroug Date 2007-08-06 Time 13:32 Sent To B
Notes
2007-08-06 13:32:29TO "SHILL" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-07-23 Cont ID  
Sent By adarroug Date 2007-07-23 Time 08:51 Rev Time 0.00
Received By adarroug Date 2007-07-23 Time 08:51 Sent To B
Notes
2007-07-23 08:51:35TO "SHILL" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-07-06 Cont ID  
Sent By shill Date 2007-07-06 Time 13:58 Rev Time 0.00
Received By shill Date 2007-06-21 Time 09:20 Sent To  
Notes
2007-06-21 09:20:22TO "MISC" BOX#1


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved