Plan Review Stops For Permit 07060649 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2007-08-09 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2007-08-09 |
Time |
13:44 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2007-08-09 |
Time |
10:44 |
Sent To |
PC |
|
Notes |
2007-08-09 13:43:59 | BUILDING PROVISO: | | TO BE IN PLACE AT C.O.: | | | | 1) 424.2.17.1 OUTDOOR SWIMMING POOLS. | | OUTDOOR SWIMMING POOLS SHALL BE PROVIDED | | WITH A BARRIER COMPLYING WITH | | 424.2.17.1.1 THROUGH 424.2.17.1.14. | | | | 424.2.17.1.5 CHILD SAFETY BARRIER | | ASTM D5034 100 LB TENSILE STRNGTH | | ASTM D3787 150 LB BALL BURST STRENGTH | | | | 2) 13-612.1.ABC.2.3.2 COVERS REQUIRED. | | SPAS AND HEATED SWIMMING POOLS SHALL BE | | EQUIPPED WITH A COVER DESIGNED TO | | MINIMIZE HEAT LOSS. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2007-07-31 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2007-07-31 |
Time |
12:14 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2007-07-31 |
Time |
11:31 |
Sent To |
PC |
|
Notes |
2007-07-31 12:14:08 | BUILDING PLAN REVIEW | | PERMIT: 07060649 | | ADD: 2172 TIGRIS DR | | CONT: CUSHING POOLS | | TEL: (561)198-1441 | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | W/ 2006 FBC REVISIONS | | * WEST PALM BEACH AMENDMENTS | | | | REVIEW 2ND | | ACTION: DENIED | | | | 1) FBC 106.1.1ALL INFORMATION SHALL BE OF SUFFICIENT | | CLARITY. THE INFORMATION SUBMITTED HAS CONFLICTING | | INFORMATION ABOUT THE SIZE OF THE POOL.SUBMIT TWO NEW | | COMPLETE SETS OF DRAWINGS AND ONE OLD SET FOR REVIEW. | | REMOVE THE OLD SHEET AND REPLACE IT WITH THE NEW | | SHEET. | | | | MYRON JACOBS | | BUILDING PLAN REVIEWER | | 805-6726 | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2007-07-13 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2007-07-13 |
Time |
17:54 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2007-07-13 |
Time |
17:14 |
Sent To |
PC |
|
Notes |
2007-07-13 17:54:31 | BUILDING PLAN REVIEW | | PERMIT: 07060649 | | ADD: 2172 TIGIS DR. | | CONT: CUSHING POOLS CONST. INC. | | TEL: (561)798-1441 | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | W/ 2006 FBC REVISIONS | | * WEST PALM BEACH AMENDMENTS | | | | REVIEW 1ST | | ACTION: DENIED | | | | 1) ALL PLANS SUBMITTED AFTER OCTOBER, 1, | | 2004 SHALL BE DESIGNED TO THE 2004 | | FLORIDA BUILDING CODE WITH 2006 FBC REVISIONS. | | | | MYRON JACOBS | | BUILDING PLAN REVIEWER | | 805-6726 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2007-06-26 |
|
|
Cont ID |
|
Sent By |
choops |
Date |
2007-06-22 |
Time |
13:30 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2007-06-26 |
Time |
11:37 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
N |
Date |
2007-07-10 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2007-07-10 |
Time |
14:56 |
Rev Time |
0.00 |
Received By |
mperson |
Date |
2007-07-10 |
Time |
14:56 |
Sent To |
B |
|
Notes |
2007-07-10 14:56:53 | NOTE: THERE IS NO POOL HEATER. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2007-08-02 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-08-02 |
Time |
16:05 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-08-02 |
Time |
16:05 |
Sent To |
Z |
|
Notes |
2007-08-02 16:05:51 | TO "Z" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2007-07-24 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-07-24 |
Time |
15:33 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-07-24 |
Time |
15:33 |
Sent To |
Z |
|
Notes |
2007-07-24 15:33:29 | TO "Z" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2007-07-13 |
Time |
|
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-06-22 |
Time |
09:44 |
Sent To |
|
|
Notes |
2007-06-22 09:45:04 | TO "Z" BOX |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2007-07-10 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2007-07-10 |
Time |
14:55 |
Rev Time |
0.33 |
Received By |
mperson |
Date |
2007-07-10 |
Time |
14:55 |
Sent To |
G |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2007-08-06 |
|
|
Cont ID |
|
Sent By |
choops |
Date |
2007-08-06 |
Time |
10:48 |
Rev Time |
0.00 |
Received By |
choops |
Date |
2007-08-06 |
Time |
10:48 |
Sent To |
B |
|
Notes |
2007-08-06 10:49:16 | SENT TO MJ |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2007-07-24 |
|
|
Cont ID |
|
Sent By |
choops |
Date |
2007-07-24 |
Time |
16:54 |
Rev Time |
0.00 |
Received By |
choops |
Date |
2007-07-24 |
Time |
16:54 |
Sent To |
B |
|
Notes |
2007-07-24 16:56:24 | ***FAILED*** | | | | | | 1)AS THE POOL EQUIPMENT LOCATION HAS CHANGED AND NO | | SETBACK DIMENSION PROVIDED...PLANS SHALL SHOW SETBACK | | DIMENSION FROM PROPOSED POOL EQUIPMENT TO THE PROPERTY | | LINES. | | | | 2)(REPEAT COMMENT) AS THE SURVEY DOES NOT SHOW AN | | EXISTING FENCE COMPLETELY SURROUNDING THE POOL, A FENCE | | PERMIT SHALL BE SUBMITTED CONCURRENTLY AND SHALL | | CONFORM TO THE MINIMUM STANDARDS PROVIDED BELOW. | | | | AS PER THE CITY OF WEST PALM BEACH ZONING AND LAND | | DEVELOPMENT REGULATIONS, SECTION, 94-304(D)(2)(B)+(C): | | | | B.EVERY SWIMMING POOL SHALL BE ENCLOSED BY A FENCE | | OR SIMILAR STRUCTURE WHICH IS INSTALLED TO OBSTRUCT | | ACCESS BY PERSONS OTHER THAN THE OWNERS OR OCCUPANTS OF | | THE RESIDENCE WITHIN WHICH A SWIMMING POOL IS LOCATED. | | BARRIERS OR FENCES SHALL BE AT LEAST FOUR FEET IN | | HEIGHT ABOVE GRADE. | | C.ACCESS TO AN ACCESSORY SWIMMING POOL MUST BE | | THROUGH A BUILDING OR THROUGH A SELF-CLOSING AND | | SELF-LATCHING GATE OR THROUGH A SCREEN ENCLOSURE DOOR | | WITH LATCHES PLACED AT LEAST 54 INCHES ABOVE BOTTOM OF | | GATE. AT LEAST 90 PERCENT OF THE SURFACE AREA OF ALL | | SCREEN ENCLOSURES SHALL BE SCREENING MATERIAL THROUGH | | WHICH AIR SHALL FLOW. ALL POOLS LOCATED ON A CORNER LOT | | SHALL BE SCREENED AT THE CORNER LOT LINE BY AT LEAST A | | 42-INCH HIGH LANDSCAPE BUFFER, AS MEASURED FROM GRADE, | | AT THE PROPERTY LINE, TO ENSURE PRIVACY. | | | | 3)PLEASE PROVIDE AN ACC (ARCHITECTURAL CONTROL | | COMMITTEE) APPROVAL FROM RIVERWALK HOA. | | | | | | | | QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, ZONING | | TECHNICIAN | | (561)805-6720 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2007-06-22 |
|
|
Cont ID |
|
Sent By |
choops |
Date |
2007-06-22 |
Time |
13:30 |
Rev Time |
0.00 |
Received By |
choops |
Date |
2007-06-22 |
Time |
13:30 |
Sent To |
E |
|
Notes |
2007-06-22 13:37:50 | ***FAILED*** | | | | | | 1)SETBACKS ARE INSUFFICIENT.MEASURED FROM WATER'S | | EDGE, THERE MUST BE A 5' SETBACK TO BOTH THE SIDES AND | | THE REAR PROPERTY LINE.ALSO, PLEASE INDICATE DISTANCE | | FRO PRINCIPAL STRUCTURE TO WATER'S EDGE (MUST BE A | | MINIMUM OF 4'). | | | | 2)AS THE SURVEY DOES NOT SHOW AN EXISTING FENCE | | SURROUNDING THE POOL, A FENCE PERMIT SHALL BE SUBMITTED | | CONCURRENTLY AND SHALL CONFORM TO THE MINIMUM STANDARDS | | PROVIDED BELOW. | | | | AS PER THE CITY OF WEST PALM BEACH ZONING AND LAND | | DEVELOPMENT REGULATIONS, SECTION 94-304(D)(2)(B)+(C): | | | | B.EVERY SWIMMING POOL SHALL BE ENCLOSED BY A FENCE | | OR SIMILAR STRUCTURE WHICH IS INSTALLED TO OBSTRUCT | | ACCESS BY PERSONS OTHER THAN THE OWNERS OR OCCUPANTS OF | | THE RESIDENCE WITHIN WHICH A SWIMMING POOL IS LOCATED. | | BARRIERS OR FENCES SHALL BE AT LEAST FOUR FEET IN | | HEIGHT ABOVE GRADE. | | C.ACCESS TO AN ACCESSORY SWIMMING POOL MUST BE | | THROUGH A BUILDING OR THROUGH A SELF-CLOSING AND | | SELF-LATCHING GATE OR THROUGH A SCREEN ENCLOSURE DOOR | | WITH LATCHES PLACED AT LEAST 54 INCHES ABOVE BOTTOM OF | | GATE. AT LEAST 90 PERCENT OF THE SURFACE AREA OF ALL | | SCREEN ENCLOSURES SHALL BE SCREENING MATERIAL THROUGH | | WHICH AIR SHALL FLOW. ALL POOLS LOCATED ON A CORNER LOT | | SHALL BE SCREENED AT THE CORNER LOT LINE BY AT LEAST A | | 42-INCH HIGH LANDSCAPE BUFFER, AS MEASURED FROM GRADE, | | AT THE PROPERTY LINE, TO ENSURE PRIVACY. | | | | | | CHRIS HOOPS | | ZONING TECHNICIAN | | 561-805-6720 |
|
|