Plan Review Stops For Permit 07060606 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2007-12-04 |
|
|
Cont ID |
|
Sent By |
amorse |
Date |
2007-12-04 |
Time |
17:05 |
Rev Time |
0.00 |
Received By |
amorse |
Date |
2007-12-04 |
Time |
17:04 |
Sent To |
PC |
|
Notes |
2007-12-04 17:41:33 | DENIED | | | | THE FOLLOWING COMMENT WERE NOT ADDRESSED ON THE 1ST | | REVIEW: | | | | 3)THE PERMIT APPLICATION SHALL INCLUDE TWO COPIES OF | | EACH PRODUCT APPROVAL THAT IS RELEVANT PER 9B-72. THESE | | SHOULD INCLUDE THE FLORIDA STATE APPROVAL COVER PAGES. | | ALL CAN BE FOUND ON WWW.FLORIDABUILDING.ORG | | | | 4) THE CITY OF WEST PALM BEACH REQUIRES THE FLORIDA | | STATE PRODUCT APPROVAL COVER | | SHEETS WHEN AVAILABLE. THEY CAN BE SEARCHED FOR ON | | WWW.FLORIDABUILDING.ORG.WHEN AVAILABLE AND NOT | | SUBMITTED APPLICATIONS WILL BE DENIED | | | | 6)THOSE PRODUCTS WHICH ARE REGULATED BY DCA RULE | | 9B-72 (PRODUCT APPROVALS) SHALL BE REVIEWED AND | | APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR TO | | SUBMITTAL FOR JURISDICTIONAL APPROVAL PER 106.3.3 FBC* | | ********THE PERSONS RESPONSIBLE FOR THE DRAWINGS MUST | | REVIEW AND APPROVE THE PRODUCTS TO BE USED********* | | | | 8)SUBMIT TWO COPIES OF ENERGY CALC'S PER 13-101.2.2 | | FBC. BE SURE THAT THEY ARE SIGNED AND DATED BY PREPARER | | AND OWNER/AGENT PRIOR TO SUBMITTAL | | *********SUBMIT ENERGY CALCULATIONS BASED ON THE | | CONSTRUCTION OF THE ADDITION, NOTE THAT NO INSULATION | | VALUE WAS GIVEN TO THE ROOF******** | | | | 10)TO CONFORM TO THE ZONING (SEE ZONING REVIEW) | | **********ZONING REVIEW COMMENTS MUST BE ADDRESSED | | BEFORE PROJECT CAN BE PERMITTED********* | | | | 11)PROVIDE SMOKE ALARMS TO EXISTING BUILDING PER | | R313.1.1 FBC RES. | | **********PROVIDE FULL FLOOR PLAN TO SHOW | | COMPLIANCE*********** | | | | 13)A RECORDED COPY OF THE NOTICE OF | | COMMENCEMENT IS REQUIRED PRIOR TO | | A PERMIT BEING ISSUED | | | | NEW REVIEW COMMENTS FROM PRODUCT APPROVALS: | | | | 1)PRODUCT APPROVALS WERE SUBMITTED FOR BOTH SINGLE | | HUNG IMPACT WINDOWS AND FIXED NON-IMPACT, PLEASE | | PROVIDE LOCATION,TYPE AND SIZE OF WINDOWS ON THE | | DRAWINGS. | | | | 2)CHOOSE A ROOFING SYSTEM FROM THE PRODUCT APPROVAL, | | NON INSULATED WOOD DECKS ARE ON PAGES 17 & 18. PLEASE | | NOTE THAT THE DESIGN PRESSURES LISTED IN THE NOA DO NOT | | MEET THE REQUIREMENTS FOR THE PERIMETER AND CORNER | | ZONES AND THEREFORE CALCULATION MUST BE PROVIDED BY AN | | ARCHITECT, ENGINEER OR ROOFING CONSULTANT. INCLUDE | | THESE CALCULATIONS WITH THE PRODUCT APPROVAL. | | | | 3)THE SYMBOLS 2 & 2A ON THE FOOTING SCHEDULE SEEM TO | | BE THE OPPOSITE OF THE FOUNDATION PLAN AND WALL | | SECTIONS PLEASE CLARIFY | | | | BLDG PLAN REVIEW | | ADRIAN MORSE | | 561-805-6716 | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2007-07-11 |
|
|
Cont ID |
|
Sent By |
amorse |
Date |
2007-07-11 |
Time |
17:33 |
Rev Time |
0.00 |
Received By |
amorse |
Date |
2007-07-11 |
Time |
17:33 |
Sent To |
PC |
|
Notes |
2007-07-11 17:57:38 | | | | | DENIED | | | | 1)THE CLAIMED VALUATION ON THE PERMIT APPLICATION IS | | LOW. FOR PERMITTING PURPOSES, VALUATION OF BUILDINGS | | AND SYSTEMS SHALL BE THE TOTAL REPLACEMENT COST | | EXCLUDING LAND VALUE. OUR VALUATION REFERENCE IS ICC | | (BVD), MARSHALL-SWIFT AND MEANS COST ANALYSIS SERVICES | | PER 108.3 FBC* | | | | 2)THE STATE OF FLORIDA REQUIRES COLLECTION OF A RADON | | SURCHARGE ON ALL NEW CONSTRUCTION COMPUTED ON UNDER | | ROOF FLOOR SPACE PER 10D-91 FAC. THESE FEES WILL BE | | ADDED TO THE PERMIT APPLICATION FEES. NOTE FEES ARE DUE | | IN THE AMOUNT OF $ 1.44 FOR STATE OF FLORIDA RADON FEE | | | | 3)THE PERMIT APPLICATION SHALL INCLUDE TWO COPIES OF | | EACH PRODUCT APPROVAL THAT IS RELEVANT PER 9B-72. THESE | | SHOULD INCLUDE THE FLORIDA STATE APPROVAL COVER PAGES. | | ALL CAN BE FOUND ON WWW.FLORIDABUILDING.ORG | | | | 4) THE CITY OF WEST PALM BEACH REQUIRES THE FLORIDA | | STATE PRODUCT APPROVAL COVER | | SHEETS WHEN AVAILABLE. THEY CAN BE SEARCHED FOR ON | | WWW.FLORIDABUILDING.ORG.WHEN AVAILABLE AND NOT | | SUBMITTED APPLICATIONS WILL BE DENIED | | | | 5)NO PRODUCT APPROVALS WERE SUBMITTED FOR ROOF | | MEMBRANE, AND CONSTRUCTION STRAPS/TIES | | | | 6)THOSE PRODUCTS WHICH ARE REGULATED BY DCA RULE | | 9B-72 (PRODUCT APPROVALS) SHALL BE REVIEWED AND | | APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR TO | | SUBMITTAL FOR JURISDICTIONAL APPROVAL PER 106.3.3 FBC* | | | | 7)ALTHOUGH THE DRAWINGS SHOW THE MINIMUM DEPTH OF | | FOUNDATION ON THE WALL SECTIONS PER R403.1.4 FBC RES. | | PLEASE SEE THAT THE ELEVATION DRAWINGS ON A/2 SHOWS THE | | FINISHED GRADE AT 36" BELOW FIN FLOOR AND THE | | MONOLITHIC FOUNDATION IS ONLY 20" DEEP. | | | | 8)SUBMIT TWO COPIES OF ENERGY CALC'S PER 13-101.2.2 | | FBC. BE SURE THAT THEY ARE SIGNED AND | | DATED BY PREPARER AND OWNER/AGENT PRIOR | | TO SUBMITTAL | | | | 9)PROVIDE A SITE PLAN THAT SHOWS DRAINAGE IN | | COMPLIANCE WITH THE REQUIREMENTS OF R403.1 FBC RES. | | | | 10)TO CONFORM TO THE ZONING (SEE ZONING REVIEW) | | REGULATIONS THE ADDITION WALL THAT TIES INTO THE | | EXISTING BUILDING ON THE SOUTH SIDE WILL BE REQUIRED TO | | JOG OVER SO THAT THE BACK CORNER IS NOT ANY CLOSER TO | | THE PROPERTY LINE THAN THE EXISTING BUILDING 3.43 FEET. | | SEE THAT THE PROPOSED DISTANCE WOULD BE 3.31 THUS | | INCREASING THE NONCONFORMITY. | | | | 11)PROVIDE SMOKE ALARMS TO EXISTING BUILDING PER | | R313.1.1 FBC RES. | | | | 12)PROVIDE MIN ROOF SHEATHING ATTACHMENT | | PER R803.2.3.1 FBC RES. SHALL BE 8D RING SHANK AT 6" | | O/C EDGES AND FIELD AND 4" O/C EDGES AND FIELD IN ZONES | | 2 & 3 | | | | 13)A RECORDED COPY OF THE NOTICE OF | | COMMENCEMENT IS REQUIRED PRIOR TO | | A PERMIT BEING ISSUED | | | | BLDG PLAN REVIEW | | ADRIAN MORSE | | 561-805-6716 | | | | | | | | | | | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2007-11-08 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2007-11-08 |
Time |
16:20 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2007-11-08 |
Time |
16:03 |
Sent To |
M |
|
Notes |
2007-11-08 16:20:32 | | | | | | | DENIED/INCOMPLETE INFORMATION | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS FOR CODE | | COMPLIANCE AND RESUBMIT FOR REVIEW | | | | COMMENTS FROM PREVIOUS REVIEW; | | | | 1} THE PERSON TAKING RESPONSIBILITY FOR THE DESIGN MUST | | PRINT AND SIGN THEIR NAME TO SAME PER 106.3.4.3. FBC. | | IF AN ARCHITECT OR ENGINEER, COMPLY WITH 418 AND 417 | | FS, RESPECTIVELY.* NO SIGNATURES. | | | | 2} INDICATE THAT THE BATHROOM CIRCUITS COMPLY WITH | | 210.11(C)(3).* STILL NOT LISTED ON THE SCHEDULE. | | | | 3} INDICATE WHAT THE APPLIANCE IN THE BATHROOM IS. | | THERE IS NO SYMBOL IN THE LEGEND INDICATING VOLTAGE OR | | AMPERAGE FOR THAT APPLIANCE. | | | | 4} THE PANEL SCHEDULE IS INCOMPLETE. IF PROVIDING ONE | | IT MUST BE COMPLETE PER 106.3.5.4(8), FBC AS AMENDED. | | | | 6} THERE IS A CONDENSING UNIT ON THE PLAN. LOCATE THE | | AHU IF THIS IS BEING INSTALLED UNDER THE SCOPE OF THIS | | PERMIT. SHOW COMPLIANCE WITH 210.63 FOR THE RECEPTACLE | | AND 110.26 FOR THE DISCONNECT. | | | | 7} R313.1.1 SMOKE ALARMS SHALL BE LOCATED AS REQUIRED | | IN NEW DWELLINGS WHEN REPAIRS OR ADDITIONS REQUIRING A | | PERMIT OCCUR. SEE ARTICLE FOR COMPLETE TEXT. | | | | NEW COMMENTS THIS REVIEW: | | | | 1} PLEASE INDICATE THE CODE CYCLES THIS PROJECT WAS | | DESIGNED UNDER. 2004 FBC, 2005 NEC ETC. ADD TO NOTES | | FOR CLARITY IN THE FIELD AND RECORD RETENTION PER | | 106.1.3 FBC AS AMENDED. | | | | 2 ]SUBMIT WRITTEN RESPONSE TO THE COMMENTS MADE IN THIS | | REVIEW. | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | BILL TROBAUGH | | ELECTRICAL PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561/805-6718 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2007-06-22 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2007-06-22 |
Time |
07:46 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2007-06-22 |
Time |
07:02 |
Sent To |
M |
|
Notes |
2007-06-22 07:46:10 | | | | | | | DENIED/INCOMPLETE INFORMATION | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS FOR CODE | | COMPLIANCE AND RESUBMIT FOR REVIEW | | | | 1} THE PERSON TAKING RESPONSIBILITY FOR THE DESIGN MUST | | PRINT AND SIGN THEIR NAME TO SAME PER 106.3.4.3. FBC. | | IF AN ARCHITECT OR ENGINEER, COMPLY WITH 418 AND 417 | | FS, RESPECTIVELY. | | | | 2} INDICATE THAT THE BATHROOM CIRCUITS COMPLY WITH | | 210.11(C)(3). | | | | 3} INDICATE WHAT THE APPLIANCE IN THE BATHROOM IS. | | THERE IS NO SYMBOL IN THE LEGEND INDICATING VOLTAGE OR | | AMPERAGE FOR THAT APPLIANCE. | | | | 4} THE PANEL SCHEDULE IS INCOMPLETE. IF PROVIDING ONE | | IT MUST BE COMPLETE PER 106.3.5.4(8), FBC AS AMENDED. | | | | 5} INDICATE IF THE SERVICE IS NEW OR EXISTING. REMOVE | | NOTES AND SCHEMATICS THAT ARE NOT RELEVANT TO THE WORK | | TO BE PERMITTED. IF INSTALLED UNDER THIS PERMIT, PER | | 110.9 AND 110.10: OBTAIN THE | | AVAILABLE FAULT CURRENT AT THE UTILITY | | AND CALCULATE THE SAME AT THE EQUIPMENT. | | INDICATE THE AIC RATING FOR THE | | EQUIPMENT IS EQUAL TO OR GREATER THAN | | THE AVAILABLE FAULT. | | | | 6} THERE IS A CONDENSING UNIT ON THE PLAN. LOCATE THE | | AHU IF THIS IS BEING INSTALLED UNDER THE SCOPE OF THIS | | PERMIT. SHOW COMPLIANCE WITH 210.63 FOR THE RECEPTACLE | | AND 110.26 FOR THE DISCONNECT. | | | | 7} R313.1.1 SMOKE ALARMS SHALL BE LOCATED AS REQUIRED | | IN NEW DWELLINGS WHEN REPAIRS OR ADDITIONS REQUIRING A | | PERMIT OCCUR. SEE ARTICLE FOR COMPLETE TEXT. | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | BILL TROBAUGH | | ELECTRICAL PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561/805-6718 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2007-11-06 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-11-06 |
Time |
09:24 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-11-06 |
Time |
09:24 |
Sent To |
Z |
|
Notes |
2007-11-06 09:24:19 | TO "Z" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2007-07-11 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-07-11 |
Time |
09:22 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-06-20 |
Time |
11:26 |
Sent To |
|
|
Notes |
2007-06-20 11:26:18 | TO "Z" BOX |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2007-11-09 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2007-11-09 |
Time |
11:28 |
Rev Time |
0.25 |
Received By |
tgordon |
Date |
2007-11-09 |
Time |
11:28 |
Sent To |
P |
|
Notes |
2007-11-09 11:37:05 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | REFERENCED CODES WITH 05, 06 REVISIONS, CITY OF WEST | | PALM BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | (F.S.). | | | | *** DENIED *** | | 1) AS NOTED IN LAST REVIEW 6-22-07.MECHANICAL PERMIT | | #07060608 HAS BEEN APPLIED FOR BUT NO MECHANICAL PLANS | | WERE SUBMITTED FOR REVIEW. PLEASE SUBMIT MECHANICAL | | PLANS FOR REVIEW, PER 2004 FBC CITY OF WPB AMEND. | | 106.3.5.4 (10). | | | | 2) AS NOTED IN LAST REVIEW 6-22-07. SUBMIT ENERGY | | CALCULATIONS, PER 2004 FBC 13-101.2.2. | | | | 3) AS NOTED IN LAST REVIEW 6-22-07. PLANS SHOW NO ATTIC | | INSULATION, SEE 2004 FBC 13-604.1.ABC.1 PLEASE COMPLY. | | | | 4) SEE ATTACHED NOTICE FS 553.80 (2) (B) REGARDING FOUR | | TIMES THE FEE. | | | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729 | | E-MAIL; [email protected] |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2007-06-22 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2007-06-22 |
Time |
10:51 |
Rev Time |
0.25 |
Received By |
tgordon |
Date |
2007-06-22 |
Time |
10:51 |
Sent To |
P |
|
Notes |
2007-06-22 11:04:48 | *** DENIED *** | | 1) MECHANICAL PERMIT #07060608 HAS BEEN APPLIED FOR BUT | | NO MECHANICAL PLANS WERE SUBMITTED FOR REVIEW. PLEASE | | SUBMIT MECHANICAL PLANS FOR REVIEW, PER 2004 FBC CITY | | OF WPB AMEND. 106.3.5.4 (10). | | | | 2) PLEASE SUBMIT ENERGY CALCULATIONS, SEE 2004 FBC | | 13-101.2.2. | | | | 3) PLANS DO NOT SHOW ANY ATTIC INSULATION, PLEASE | | CORRECT. | | | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2007-11-28 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2007-11-28 |
Time |
07:52 |
Rev Time |
0.00 |
Received By |
jleech |
Date |
2007-11-28 |
Time |
07:28 |
Sent To |
B |
|
Notes |
2007-11-28 07:58:37 | DENIED; | | SANITARY RISER DIAGRAM DOES NOT MATCH FLOOR PLAN. | | AUTOMATIC CLOTHES WASHER REQUIRES A VENT WITH A | | CLEANOUT AT 48" AFF. | | PLUMBING PLAN REVIEW BY; | | JOHN LEECH | | 805-6695 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2007-07-10 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2007-07-10 |
Time |
08:28 |
Rev Time |
0.00 |
Received By |
jleech |
Date |
2007-07-10 |
Time |
08:28 |
Sent To |
B |
|
Notes |
2007-07-10 08:36:56 | DENIED; | | 1. RISER DIAGRAM DOES NOT MATCH FLOOR PLAN. | | 2. AUTOMATIC CLOTHES WASHER NOT SHOWN ON RISER DIAGRAM. | | BRANCH DRAIN IS REQUIRED TO BE 3" WITH A CLEANOUT ON | | VENT STACK AT 48" ABOVE FINISH FLOOR. | | PLUMBING PLAN REVIEW BY | | JOHN LEECH | | 805-6695 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2007-11-08 |
|
|
Cont ID |
|
Sent By |
choops |
Date |
2007-11-08 |
Time |
08:44 |
Rev Time |
0.00 |
Received By |
choops |
Date |
2007-11-08 |
Time |
08:44 |
Sent To |
E |
|
Notes |
2007-11-08 08:50:46 | ***FAILED - RESUB #1*** | | | | | | 1)A MISINTERPRETATION OF THE CODE WAS MADE ON THE | | PREVIOUS REVIEW.PURSUANT TO THE CITY OF WEST PALM | | BEACH ZONING AND LAND DEVELOPMENT REGULATIONS, SECTION | | 94-513(A)(2): | | NONCONFORMING STRUCTURES OR BUILDINGS SHALL NOT BE | | IMPROVED, CONSTRUCTED, ENLARGED, OR ALTERED IN ANY | | MANNER TO CREATE A NEW NONCONFORMITY OR TO INCREASE AN | | EXISTING NONCONFORMITY, BUT MAY BE IMPROVED, | | CONSTRUCTED, ENLARGED, OR ALTERED AS LONG AS NO NEW | | NONCONFORMITY IS CREATED OR AN EXISTING NONCONFORMITY | | INCREASED. | | | | THE PROPOSED ADDITION MUST MEET CURRENT SETBACK | | REQUIREMENTS SET FORTH IN SECTION 94-72(A)(2): | | MINIMUM SETBACK REQUIREMENTS:SIDE = FIVE FEET MINIMUM | | WITH A TOTAL OF FIFTEEN FEET BETWEEN THE TWO SIDES. | | REAR = 15 FEET OR 10% OF THE LOT DEPTH WHICHEVER IS | | LESS. | | | | NOTE:MAY NOT BUILD ANYTHING OUTSIDE OF PROPERTY | | LINES. | | | | | | QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, | | ZONING TECHNICIAN (561)805-6720 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2007-06-21 |
|
|
Cont ID |
|
Sent By |
choops |
Date |
2007-06-21 |
Time |
08:44 |
Rev Time |
0.00 |
Received By |
choops |
Date |
2007-06-21 |
Time |
08:44 |
Sent To |
E |
|
Notes |
2007-06-21 08:55:33 | ***FAILED*** | | | | | | 1)IS THE A/C UNIT SHOWN, NEW OR EXISTING?IF NEW, | | IT MUST BE RELOCATED TO REAR OF PROPERTY, IT MAY NOT | | SIT DIRECTLY ON SIDE PROPERTY LINE. | | | | 2)AS THIS IS AN EXISTING NON-CONFORMING BUILDING, AS | | PER THE CITY OF WEST PALM BEACH ZONING AND LAND | | DEVELOPMENT REGULATIONS, SECTION 94-513(A)(2): | | NONCONFORMING STRUCTURES OR BUILDINGS SHALL NOT BE | | IMPROVED, CONSTRUCTED, ENLARGED, OR ALTERED IN ANY | | MANNER TO CREATE A NEW NONCONFORMITY OR TO INCREASE AN | | EXISTING NONCONFORMITY, BUT MAY BE IMPROVED, | | CONSTRUCTED, ENLARGED, OR ALTERED AS LONG AS NO NEW | | NONCONFORMITY IS CREATED OR AN EXISTING NONCONFORMITY | | INCREASED. | | | | | | CHRIS HOOPS | | ZONING TECHNICIAN | | 561-805-6720 |
|
|