Plan Review Details - Permit 07060426
Plan Review Stops For Permit 07060426 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2007-07-13 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-07-13 |
Time |
17:47 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-07-13 |
Time |
17:47 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2007-06-26 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-06-26 |
Time |
17:10 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-06-26 |
Time |
17:10 |
Sent To |
|
|
Notes |
2007-06-26 17:15:16 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBCFLORIDA BUILDING CODE 2004 | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | CODE | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | FAC FLORIDA ADMINISTRATIVE CODE | | FSFLORIDA STATUTE | | | | | | 1.)PLEASE REVISE CORNER FASTENING.SEE CALCULATIONS, | | HIGHLIGHTED (2" CENTER ROWS).THERE ARE SEVERAL MINOR | | ERRORS IN THE CALCULATIONS (OFF BY A FRACTION WHICH MAY | | AFFECT SOME JOBS BUT DOES NOT AFFECT THIS ONE), BUT ONE | | SIGNIFICANT APPARENT ERROR IS THAT THE "2" CENTER ROWS" | | STATES THAT THERE ARE 52 FASTENERS, BUT SHOULD BE | | DOUBLE THIS NUMBER.IN OTHER WORDS, IF THE SIDE LAP IS | | 51 FASTENERS, 8" SPACING, THE TWO CENTER ROWS WOULD BE | | AT LEAST 102 FASTENERS WITH THE SAME SPACING.PLEASE | | CONTACT ME IF YOU NEED ASSISTANCE OR DISAGREE. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2007-06-14 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-06-14 |
Time |
08:40 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-06-14 |
Time |
08:40 |
Sent To |
|
|
Notes |
2007-06-14 08:45:09 | ****CORRECTIONS**** | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBCFLORIDA BUILDING CODE 2004 | | FBC EBFLORIDA BUILDING CODE 2004 | | EXISTING BUILDING CODE | | FBC*CITY OF WEST PALM BEACH | | AMENDMENTS TO THE FBC2004 | | | | ROOFING PERMIT; ONLY CHECKED ITEMS APPLY | | | | _XX_1.)POLYPRO PRODUCT APPROVAL IS ILLEGIBLE. | | | | _XX_2.)CONTRACTOR IS TO PROVIDE THE FOLLOWING | | INFORMATION ON THE APPLICATION, SEE ATTACHED POLICY; | | MEAN ROOF HEIGHT, ROOF PITCH, ROOF DECK TYPE, AREA OF | | EACH ROOF TYPE | | | | _XX_3.)FLORIDA STATE OR LOCAL PRODUCT APPROVAL | | REQUIRED IN ADDITION TO THE EVALUATION REPORT | | SUBMITTED, FAC9B72.WWW.FLORIDABUILDING.ORG | | | | _XX_4.)CONTRACTOR HAS SUBMITTED SHINGLE AND TILE | | PRODUCT APPROVAL.IF BOTH ARE BEING INSTALLED, PROVIDE | | A ROOF PLAN SHOWING WHERE EACH TYPE OF ROOF WILL BE | | INSTALLED (FLAT, SHINGLE, TILE). | | | | _XX_5.)FOR THE FLAT DECK, SPECIFY THE ENHANCED | | FASTENING FOR CORNER AND PERIMETER ZONES.CALCULATIONS | | PREPARED BY AN ARCHITECT, ENGINEER, OR REGISTERED ROOF | | CONSULTANT ARE REQUIRED. | | | | ____ 6.)ON THE TILE PRODUCT APPROVAL, INDICATE WHICH | | METHOD OF ATTACHMENT YOU ARE USING. | | | | _XX_ 7.)SEE PRODUCT LIMITATION #7 (FLAT DECK, | | POLYGLASS).CALCULATIONS PREPARED BY AN ARCHITECT, | | ENGINEER, OR REGISTERED ROOF CONSULTANT REQUIRED FOR | | ENHANCED FASTENING. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2007-06-26 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-06-26 |
Time |
15:38 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-06-26 |
Time |
15:38 |
Sent To |
B |
|
Notes |
2007-06-26 15:40:01 | TO "SHILL" DESK/RESUB |
|
|
|