Plan Review Details - Permit 07060314
Plan Review Stops For Permit 07060314
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2007-09-12 Cont ID  
Sent By shill Date 2007-09-12 Time 10:33 Rev Time 0.00
Received By shill Date 2007-09-12 Time 10:33 Sent To  
Notes
2007-09-12 10:34:48****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
  
 FAC FLORIDA ADMINISTRATIVE CODE
 FSFLORIDA STATUTE
  
 1.)FLORIDA STATE OR LOCAL PRODUCT APPROVALS REQUIRED
 FOR PERMIT ISSUANCE, FAC9B72.WWW.FLORIDABUILDING.ORG
  
 THE PRODUCT APPROVALS WHICH WERE IN THE PACKAGE ARE NO
 LONGER IN THE PACKAGE.THIS IS REQUIRED FOR PERMIT
 ISSUANCE.
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2007-08-30 Cont ID  
Sent By shill Date 2007-08-30 Time 17:31 Rev Time 0.00
Received By shill Date 2007-08-30 Time 17:31 Sent To  
Notes
2007-08-30 17:35:29****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2004
 FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL FBC* CITY
 OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
 SHUTTER PERMIT APPLICATION, ONLY CHECKED ITEMS APPLY
  
 FROM PREVIOUS LIST:
  
  
 1.ENGINEER'S SIGNATURE IS TO BE ORIGINAL.
 ENGINEERING IS OPTIONAL FOR BUILDINGS UNDER 60'.
  
 NEW COMMENTS:
  
 2.)ENGINEERING IS BASED ON ASCE7-98, CORRECT VERSION
 IS ASCE7-02, FBC35.
  
 3.)TWO SETS OF PERMIT DOCUMENTS REQUIRED.ONLY ONE
 INSTALLATION SCHEDULE WAS PROVIDED.DUE TO WORK LOAD,
 I CANNOT MAKE COPIES FOR CONTRACTORS.THERE IS A
 PHOTOCOPY MACHINE IN THE LOBBY FOR THIS PURPOSE.
  
 4.)SHUTTER MOUNTING CONNECTION TYPE SHOULD BE A
 THROUGH L, SEE SHEETS 10-11 OF THE PRODUCT APPROVAL.
  
 5.)2/1/2 INCH EDGE DISTANCE WAS SPECIFIED.SEE SHEET
 11, THIS REQUIRES A FACTOR FOR ANCHOR SPACING.
  
 6.)THE ANCHOR YOU CHOSE IS NOT ONE OF THE THREE
 INCLUDED IN THE PRODUCT APPROVAL.EITHER SELECT ONE
 FROM THE PRODUCT APPROVAL OR PROVIDE ENGINEERING.
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-06-19 Cont ID  
Sent By shill Date 2007-06-19 Time 11:50 Rev Time 0.00
Received By shill Date 2007-06-19 Time 11:50 Sent To  
Notes
2007-06-19 11:51:47****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2004
 FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
  
 SHUTTER PERMIT APPLICATION, ONLY CHECKED ITEMS APPLY
  
 ____1.A NOTICE OF COMMENCEMENT MUST BE FILED WITH
 THE CLERK OF COURTS BEFORE A PERMIT CAN BE ISSUED,
 FS713.13.
  
 ____2.PROVIDE BUILDING HEIGHT ON THE PLAN.DESIGN
 PRESSURES FOR BUILDINGS OVER 60FEET ARE REQUIRED TO BE
 DESIGNED USING ASCE7, FBC1609.1.1 AND MUST BE DONE BY A
 DESIGN PROFESSIONAL. DOCUMENTS PREPARED BY AN ENGINEER
 AND SUBMITTED FOR PUBLIC RECORD ARE TO BE SIGNED SEALED
 ORIGINALS FAC61G15-23.002.
  
 ____3.PROVIDE A COPY OF THE CONDO ASSOCIATION
 APPROVAL.
  
 _XX_4.COMPLETE THE ATTACHED INSTALLATION SCHEDULE
 OR PROVIDE ALL INFORMATION TO SHOW CODE COMPLIANCE IN
 ANOTHER FORMAT.
  
 _XX_5.FLORIDA STATE OR LOCAL PRODUCT APPROVAL
 REQUIRED, FAC9B72, WWW.FLORIDABUILDING.ORG.IF A STATE
 PRODUCT APPROVAL IS NOT AVAILABLE, PLEASE ADVISE.
  
 _XX_6.THE ENGINEER IS TO HAVE ALL INFORMATION
 REQUIRED BY FAC61G15-23.002 ON EACH SHEET.ENGINEER'S
 SIGNATURE IS TO BE ORIGINAL.ENGINEERING IS OPTIONAL
 FOR BUILDINGS UNDER 60'.

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2007-09-10 Cont ID  
Sent By adarroug Date 2007-09-10 Time 09:42 Rev Time 0.00
Received By adarroug Date 2007-09-10 Time 09:42 Sent To B
Notes
2007-09-10 09:43:12TO "SHILL" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-08-28 Cont ID  
Sent By adarroug Date 2007-08-28 Time 14:46 Rev Time 0.00
Received By adarroug Date 2007-08-28 Time 14:46 Sent To B
Notes
2007-08-28 14:46:40TO "SHILL" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-06-19 Cont ID  
Sent By shill Date 2007-06-19 Time 11:51 Rev Time 0.00
Received By shill Date 2007-06-11 Time 16:13 Sent To  
Notes
2007-06-11 16:13:53TO "MISC" BOX#1