Plan Review Stops For Permit 07060292 |
Review Stop |
AD |
ADDRESSING |
Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
Received By |
|
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2007-10-26 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2007-10-26 |
Time |
16:42 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2007-10-26 |
Time |
12:41 |
Sent To |
PC |
|
Notes |
2007-10-26 17:00:16 | NEW SINGLE FAMILY RESIDENCE BUILDING REVIEW THIRD | | CHECKLIST. | | REVIEW UNDER FLORIDA RESIDENTIAL CODE 2004 AND FBC 2004 | | WITH 2006 REVISIONS. | | | | 1- NEED TO GET APPROVAL FROM ZONING. SEE ZONING | | COMMENTS. | | | | 2- SHEET 3.1 SPECIFIES CONSTRUCTION TYPE III.SPECIFY | | WHAT TYPE III.A OR B?.ALSO,BE AWARE THAT TYPE III | | CONSTRUCTION REQUIRES A TWO HOUR FIRE RATED WALL. SEE | | TABLE 601 AND TABLE 602 OF FBC 2004. NEED TO SPECIFY | | HOW ACHIEVING THE 2 HOUR FIRE RATING REQUIRED BY TABLES | | 601 AND 602 FBC 2004. | | | | 3- PROVIDE COMPLETE MANUFACTURER SPECS FOR 2 HOUR | | CONCRETE BLOCK AS REQUIRED BY ITEM 2 ABOVE. | | | | 4- RE-SUBMITTAL FEEOF $193.10 WAS NOT PAID AT TIME OF | | SUBMITTAL.IN ADDITION, NEW RE-SUBMITTAL FEEWILL BE | | DUE AT TIME OF RE-SUBMITTAL. | | | | 5- PROVIDE SOIL TEST REPORT. SEC. R401.4 OF 2004 | | FLORIDA RESIDENTIAL CODE.(REPEAT COMMENT). | | | | 6- PROVIDE 2 COPIES OF PRODUCT APPROVALS AS REQUIRED BY | | DCA RULE 9B-72 FOR: | | ***NOTE: REMEMBER THAT ENGINEER OF RECORD NEEDS TO | | REVIEW AND APPROVE ALL PRODUCT APPROVALS IN WRITING | | (NOT SIGNING AND SEALING) PRIOR TO SUBMITTAL TO THIS | | OFFICE. | | | | A) PRECAST LINTELS. PROVIDE CURRENT FLORIDA PRODUCT | | APPROVAL REPORT FL158-R2. THIS IS THE ONE THAT | | REFERENCES NOA 06-0222.01 SUBMITTED.ONE SUBMITTED IS | | FL158-R1 WHICH IS THE OLD ONE AND WAS REVISED. | | | | B) SINGLE HUNG WINDOWS. PROVIDE CURRENT FLORIDA | | PRODUCT APPROVAL REPORT FL239-R10 AND CORRESPONDING | | NOA.FL239-R4 IS OLD AND WAS REVISED. | | | | 7- STORM SHUTTERS: | | A) INSTALLATION SCHEDULE SUBMITTED SHOWS 12.5" | | ANCHOR SPACING. LOOK AT STORM PANEL DETAIL #1 ON SHEET | | 1 OF 6 OF STORM SHUTTERS DRAWINGS AND REVISE AS | | REQUIRED. | | | | B) REVISE MINIMUM PANEL LENGTH FOR THE FOLLOWING | | OPENINGS: #1, #3, #5 AND #8.SEE TABLE 2 ON PAGE 6 OF | | 6 OF SHUTTERS DRAWINGS SUBMITTED. | | | | C) CLEARLY SPECIFYSHUTTER MOUNTING CONDITION ON | | THE 4TH COLUMN OF STORM SHUTTER INSTALLATIONSCHEDULE. | | EG:NEED TO SPECIFYIFWALL MOUNTED OR BUILT OUT, | | ETC.TO VERIFY COMPLIANCE WITH WIND LOADS SEC. 1609 | | FBC 2004.(REPEAT COMMENT). | | | | D) PROVIDE KEY PLAN TO IDENTIFY OPENING LOCATION TO | | VERIFY COMPLIANCE WITH WIND LOADS SEC. 1609 FBC 2004. | | (REPEAT COMMENT). | | | | 8- ROOF DESIGN LOADS ON SHEET 5.1 IS MISSING THE ATTIC | | LIVE LOAD AS REQUIRED BY TABLE R301.5 OF 2004 FLORIDA | | RESIDENTIAL CODE. | | | | 9- A) SURVEY SUBMITTED NEEDS THE SURVEYOR ORIGINAL | | SIGNATURE AS REQUIRED BY CHAPTER 472 FLORIDA STATUTE. | | | | B) SURVEY TO HAVE COMPLETE ADDRESS NUMBER. | | | | 10- TRUSS PACKAGE: | | A) ENGINEER TO PROVIDE ORIGINAL SIGNATURE, NOT | | RUBBER STAMP SIGNATURE.SEC. 61G15-23.002 FLORIDA | | ADMINISTRATIVE CODE. | | NOTE: ONE OF OF TRUSS PACKAGE WILL BE HELD IN THIS | | OFFICE TO BE SUBMITTED TO THE BOARD OF ENGINEERS FOR | | THEIR REVIEW. | | | | B) TRUSS LOADING DOESN'T MATCH DESIGNCRITERIA | | SPECIFIED BY THE ENGINEER OF RECORD. REVISE AS | | REQUIRED. | | | | C) THERE IS AN ENGINEER OF RECORD IN THIS PROJECT. | | HIS NAME MUST BE INCLUDED IN THE TRUSS PACKAGE AS | | REQUIRED BY SEC. 61G15-31.003 FLORIDA ADMINISTRATIVE | | CODE. | | | | D) ENGINEER OF RECORD NEEDS TO REVIEW AND APPROVE | | TRUSS PACKAGE PRIOR TO SUBMITTAL TO THIS OFFICE. | | | | E) CLARIFY WHY THE ATTIC LIVE LOAD IS NONCONCURRENT. | | TABLE R301.5OF 2004 FLORIDA RESIDENTIAL CODE REQUIRES | | THIS LOAD TO BE CALCULATED ON THE TRUSSES.CLEARLY | | SPECIFY WHAT SECTION OF THE CODE ALLOWS THIS LOAD TO BE | | NONCONCURRENT AND IS NONCONCURRENT WITH WHAT OTHER | | LOADS. SEC. 106.1.2 CITY AMENDMENTS TO FBC 2004. | | | | JULIO GOMEZ | | BUILDING PLANS EXAMINER | | (561)805-6712 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2007-08-17 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2007-08-17 |
Time |
16:57 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2007-08-17 |
Time |
16:57 |
Sent To |
M |
|
Notes |
2007-08-17 16:59:11 | NEW SINGLE FAMILY RESIDENCE BUILDING REVIEW SECOND | | CHECKLIST. | | REVIEW DONE UNDER 2004 FLORIDA RESIDENTIAL CODE AND FBC | | 2004 WITH 2006 REVISIONS. | | | | 1- TYPE OF CONSTRUCTION SPECIFIED ON SHEET 3.1 IS | | WRONG. SEE SEC. 602.1 FBC 2004 AND REVISE AS REQUIRED. | | | | 2- BRING PLANS TO PALM BEACH COUNTY (2300 N. JOG RD | | (561)233-5115) TO PAY IMPACT FEES.BRING BACK STAMPED | | PLANS AND COPY OF PAID RECEIPT.REPEATED COMMENT FROM | | PREVIOUS CHECKLIST. | | | | 3- NEED RECORDED NOTICE OF COMMENCEMENT AS REQUIRED BY | | SEC. 713.13 FLORIDA STATUTE. REPEATED COMMENT FROM | | PREVIOUS CHECKLIST. | | | | 4- PROVIDE DRAINAGE PLAN AS REQUIRED BY SEC. SEC. | | R401.3 OF 2004 FLORIDA RESIDENTIAL CODE. | | ***NOTE: WATER CAN'T BE DIRECTED TO NEIGHBOR'S | | PROPERTY. REPEATED COMMENT FROM PREVIOUS CHECKLIST. | | | | 5- SHEET 1.1: | | A) REVISE PLYWOOD ROOF SHEATHING NOTE D.MINIMUM | | FASTENER PENETRATIONIS 1 3/4" AS REQUIRED BY ASTM | | C-926 AND ASTM C-1063.THEREFORE 1 3/4" NAILING AS | | SPECIFIED ON THIS NOTE IS NOT ADEQUATE. SEE ASTM | | STANDARDS AND REVISE AS REQUIRED. | | | | B) UPDATE ALL GENERAL NOTES. SEE CHAPTER 43 OF 2004 | | FLORIDA RESIDENTIAL CODE FOR SPECIFIC STANDARDS AND | | SPECIFIC YEAR TO BE USED. REPEATED COMMENT FROM | | PREVIOUS CHECKLIST. | | | | 6- OWES $415.47 FOR UPDATED VALUATION AND RADON FEES. | | REPEATED COMMENT FROM PREVIOUS CHECKLIST. | | | | 7- PROVIDE SOIL TEST REPORT. REPEATED COMMENT-FROM | | PREVIOUS CHECKLIST. | | | | 8- ENERGY CALCULATIONS NEED TO HAVE CORRECT BUILDER'S | | NAME. REPEATED COMMENT FROM PREVIOUS CHECKLIST. | | | | 9- PROVIDE 2 COPIES OF PRODUCT APPROVALS AS REQUIRED BY | | DCA RULE 9B-72 FOR: | | A) PRECAST LINTELS.NOA 03-0605.05 SUBMITTED | | EXPIRED ON 05/21/06. ON THE OTHER HAND NOA 03-0605.04 | | IS FOR 4", 6" AND 12" WIDE LINTELS. THEREFORE IT CAN BE | | USED IN THIS PROJECT BECAUSE THIS LINTEL SIZE IS NOT | | SPECIFIED ON PLANS. | | | | B) SINGLE HUNG WINDOWS. NOA 05-0928.03 SUBMITTED | | DON'T CORRESPOND TO FL239-R4 SUBMITTED. GO THE THE DCA | | WEBSITE WWW.FLORIDABUILDING.ORG TO DOWNLOAD NOA THAT | | CORRESPONDS TO FL239. | | | | C) ENTRY DOOR AS SHOWN ON PLANS. REPEAT COMMENT FROM | | PREVIOUS CHECKLIST. | | | | D) FRENCH DOORS AS SHOWN ON PLANS.NOA 05-0107.01 | | SUBMITTED DOESN'T CORRESPOND TO FL253-R2 SUBMITTED. GO | | TO DCA WEBSITE TO DOWNLOAD CORRESPONDING NOA. | | ***NOTE: THERE ARE TWO DIFFERENT PRODUCT APPROVALS | | SUBMITTED. PROVIDE ONLY ONE PRODUCT APPROVAL. ON THE | | OTHER HAND NOA 02-1216.09 EXPIRED ON 08/15/07. | | THEREFORE IT CAN'T BE USED. | | | | 10- STORM SHUTTERS: | | A) COMPLETE ALL THE INFORMATION IN THE INSTALLATION | | SCHEDULE SUBMITTED. NEED TO SPECIFY SHUTTER MOUNTING | | CONDITION (EG: WALL MOUNTED, BUILT OUT MOUNTED, ETC.), | | SHUTTER SPAN, SPECIFIC ANCHOR AND SUBSTRATE (STRUCTURE | | TO BE ATTACHED TO: CONCRETE BLOCK). | | | | B) CLEARLY MARK ON SHUTTERS DRAWINGS SPECIFIC ANCHOR | | TYPE. SEE SHEET 5 OF 6 OFSHUTTERS DRAWINGS. | | | | C) PROVIDE KEY PLAN TO IDENTIFY LOCATION OF | | OPENINGS. | | | | 11- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING | | (NOT SIGNING AND SEALING)ALL PRODUCT APPROVALS AS | | REQUIRED BY SEC. 106.3.3 CITY AMENDMENTS TO FBC 2004. | | | | 12- SHEET 2.1: REVISE WINDOW BUCK DETAIL. SEE SEC. | | R613.6.2 OF 2004 FLORIDA RESIDENTIAL CODE FOR CORRECT | | WAY OF SHOWING BUCK DETAIL.BUCK NEEDS TO PROVIDE | | FULL FRAME SUPPORT. REPEAT COMMENT FROM PREVIOUS | | CHECKLIST. | | | | 13- SHEET 5.1:ROOF DESIGN LOADS INFORMATION DOESN'T | | MATCH INFORMATION SHOWN ON SHEET. 1.1.REVISE AS | | REQUIRED. REPEATED COMMENT FROM PREVIOUS CHECKLIST. | | | | JULIO GOMEZ | | BUILDING PLANS EXAMINER | | (561)805-6712 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2007-07-11 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2007-07-11 |
Time |
17:28 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2007-07-11 |
Time |
17:14 |
Sent To |
PC |
|
Notes |
2007-07-11 17:59:31 | BUILDING REVIEW CHECKLIST: | | 1- PLANS TO SPECIFY CONSTRUCTION TYPE AS REQUIRED BY | | SEC. 602.1 OF FBC 2004. | | | | 2- GARAGE DOOR LEADING TO THE LIVING ROOM AREA NEEDS TO | | COMPLY WITH SEC. R309.1 OF 2004 FLORIDA RESIDENTIAL | | CODE. PROVIDE SPECS FOR DOOR THAT COMPLIES WITH THIS | | CODE SECTION. | | | | 3- AFTER PLANS ARE REVISED, BRING THEM TO PALM BEACH | | COUNTY (2300 N. JOG RD (561)233-5115)TO PAY IMPACT | | FEES. BRING BACK STAMPED PLANS AND COPY OF PAID | | RECEIPT. | | | | 4- BRING RECORDED NOTICE OF COMMENCEMENT AS REQUIRED BY | | SEC. 713.13 FLORIDA STATUTE. | | | | 5- PROVIDE DRAINAGE PLANS AS REQUIRED BY SEC. R401.3 OF | | 2004 FLORIDA RESIDENTIAL CODE. | | ***NOTE:WATER CAN'T BE DIRECTED TO THE NEIGHBOR'S | | PROPERTY. | | | | 6- REVISE ROOF SHEATHING NOTES ON SHEET 1.1,ROOF | | FRAMING PLANS AND PLYWOOD SHEATHING NAILING SCHEDULE. | | MINIMUM TYPE OF NAIL IS 8D RING SHANK NAIL AND SPACING | | AT ZONE 3IS 4" ON CENTER. SEESEC. R803.2.3.1 OF | | 2004 FLORIDA RESIDENTIAL CODE. | | | | 7-VALUATION DECLARED ON PERMIT APPLICATION WAS | | UPDATED AS REQUIRED BY SEC. 108.3 CITY AMENDMENTSTO | | FBC 2004.THEREFORE OWES $415.47 FOR VALUATION UPDATE | | AND RADON FEES. | | | | 8- PROVIDE SOIL TEST REPORT.2 COPIES WITH ORIGINAL | | ENGINEER'S SEAL AND SIGNATURE. | | | | 9- ENERGY CALCULATIONS: | | A) PROVIDECORRECT BUILDER INFORMATION. AND, | | COMPLETE ALL INFORMATION ON TOP OF FORM. | | B) CLARIFY ITEM 9 (B): WHERE IS THE EXTERIOR | | CONCRETE WALL WITH R11 INSULATION? ANDHOW IS THE R11 | | VALUE ACHIEVED. | | | | 10- ENERGY CALCULATIONS ARE TAKEN THE CEILING FANS | | CREDIT. THEREFORE, PLANS NEED TO SHOW SIZE OF CEILING | | FAN IN ALL ROOMS AS REQUIRED BY TABLE 13-607.1.A.1FBC | | 2004. | | | | 11- PROVIDE 2 COPIES OF PRODUCT APPROVALS AS REQUIRED | | BY DCA RULE 9B-72 FOR: | | A) ENTRY DOOR. | | B) FRENCH DOORS AS SHOWN ON PLANS. | | C) SINGLE HUNG WINDOWS. | | D) STORM SHUTTERS IF SINGLE HUNG WINDOWS DON'T HAVE | | IMPACT GLASS. | | ***NOTE: NEED TO PROVIDE STORM SHUTTERS COMPLETE | | INSTALLATION SCHEDULE. SEE ATTACHED SAMPLE.AND, MARK | | ON SHUTTERS DRAWINGS SPECIFIC SHUTTER MOUNTING | | CONDITIONS (EG: WALL MOUNTED)AND SPECIFIC ANCHOR TYPE | | AND SPACING TO BE USED ACCORDING TO DESIGN PRESSURES, | | EDGE DISTANCE, CONNECTION TYPE, PANEL SPAN AND | | STRUCTURE TO BE ATTACHED TO (CONCRETE BLOCK).SEC. | | 106.1.2 CITY AMENDMENTS TO FBC 2004. | | E) 8" PRECAST LINTELS AS SPECIFIED ON PLANS. CLARIFY | | WHY ENGINEER APPROVED PRODUCT APPROVAL FOR 4", 6" AND | | 12" PRECAST LINTELS IF THEY WERE NOT USED? | | | | 12- SHEET 1.1: | | A) REVISE DESIGN CRITERIAITEM (D). WHAT ARE THE | | WIND ZONES AVERAGE PRESSURES? WHERE ARE THESE TAKEN | | FROM?. IS THIS REALLY REQUIRED? ALL ZONES ARE MIXED UP? | | THESE WIND ZONES ARE FOR WHAT?. WALLS, ROOF?. WHAT'S | | THE CONSIDERED TRIBUTARY AREA ?.ARE THESE FOR | | COMPONENTS AND CLADDING? SEE 2006 REVISED TABLE | | 1609.6.2.1(2). | | SEC. 106.1.2 CITY AMENDMENTS TO FBC 2004. | | | | B) REVIEW ALL NOTES AND UPDATE THE SPECIFIC STANDARD | | AND YEAR TO BE REFERENCED IN THE CODE. SEE CHAPTER 43 | | OF 2004 FLORIDA RESIDENTIAL CODE FOR CORRECT REFERENCE | | STANDARD AND YEAR TO BE USED FOR EACH CHAPTER OF THE | | CODE. | | | | C) MASONRY WALL NOTES:SEE SEC. R606.4 OF 2004 | | FLORIDA RESIDENTIAL CODE AND REVISEMINIMUM NET AREA | | COMPRESSIVE STRENGTH OF CONCRETE BLOCK. | | | | 13- SHEET 2.1: REVISE WINDOW BUCK DETAIL.SEE SEC. | | R613.6.2 OF 2004 FLORIDA RESIDENTIAL CODE FOR PROPER | | WAY OF INSTALLING THE BUCK. | | WINDOW/DOORFRAME NED TO HAVE FULL SUPPORT ON THE | | BUCK. | | | | 14- SHEET 5.1:ROOF DESIGN LOADS INFORMATION DOESN'T | | MATCH INFORMATION GIVEN ON SHEET 1.1. REVISE AS | | REQUIRED. | | | | JULIO GOMEZ | | BUILDING PLANS EXAMINER | | (561)805-6712 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2007-08-16 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2007-08-16 |
Time |
17:07 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2007-08-16 |
Time |
17:03 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2007-06-18 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2007-06-18 |
Time |
08:18 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2007-06-18 |
Time |
07:53 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2007-10-15 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-10-15 |
Time |
08:23 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-10-15 |
Time |
08:23 |
Sent To |
Z |
|
Notes |
2007-10-15 08:23:51 | TO "Z" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2007-08-09 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2007-08-09 |
Time |
12:47 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2007-08-09 |
Time |
12:47 |
Sent To |
Z |
|
Notes |
2007-08-09 12:48:07 | TO ZONING INBOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2007-07-11 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2007-07-11 |
Time |
17:59 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2007-06-12 |
Time |
08:51 |
Sent To |
|
|
Notes |
2007-06-12 08:52:09 | TO "SFR" "Z" |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
F |
Date |
2007-10-17 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2007-10-17 |
Time |
10:15 |
Rev Time |
0.30 |
Received By |
tgordon |
Date |
2007-10-17 |
Time |
10:15 |
Sent To |
B |
|
Notes |
2007-10-17 10:25:35 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | REFERENCED CODES WITH 05, 06 REVISIONS, CITY OF WEST | | PALM BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | (F.S.). | | | | *** DENIED *** | | 1) ENERGY CALCULATIONS LINE 15 IS TAKING A CREDIT FOR | | HF-WHOLE HOUSE FAN, PER 2004 FBC 13-607.1.A.3.2 THIS | | BUILDING DOES NOT QUALIFY FOR THAT CREDIT. PLEASE | | CORRECT. | | *** SEE SUBCHAPTER 13-2 DEFINITIONS WHOLE - HOUSE FAN . | | A MECHANICAL VENTILATION SYSTEM USUALLY INSTALLED IN | | THE CEILING OF A RESIDENCE WHICH IS USED TO EXHAUST AIR | | FROM THE INTERIOR OF A BUILDING TO AN ATTIC SPACE WITH | | SUFFICIENT VENTING AREA TO TRANSFER THE AIR TO THE | | OUTSIDE. | | ***13-607.1.A.3.2 WHOLE HOUSE FAN CREDIT. | | HOUSES FOR WHICH WHOLE HOUSE FAN CREDIT IS CLAIMED | | SHALL HAVE INSTALLED A WHOLE HOUSE FAN SIZED TO PROVIDE | | A MINIMUM OF 20 AIR CHANGES PER HOUR FOR THE ENTIRE | | HOUSE. THE FAN INSTALLED SHALL HAVE A FREE AIR CFM | | RATING OF AT LEAST THREE TIMES THE SQUARE FOOTAGE OF | | THE CONDITIONED AREA OF THE HOUSE. TO ENSURE ADEQUATE | | AIR EXHAUST, THE HOUSE ATTIC SHALL HAVE GABLE, RIDGE OR | | WIND TURBINE VENTS WHOSE TOTAL OPENING AREA IS EQUAL TO | | FOUR TIMES THE CEILING CUTOUT AREA FOR THE WHOLE HOUSE | | FAN. SOFFIT VENTS SHALL NOT BE INCLUDED IN THE EXHAUST | | VENT AREA. | | | | 2) PLEASE SHOW THE SIZE OF THE RETURN AIR GRILL TO THE | | AIR HANDLER, SEE W.P.B 106.3.5.4 (10). | | | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729 | | E-MAIL; [email protected] |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2007-08-20 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2007-08-20 |
Time |
16:08 |
Rev Time |
0.30 |
Received By |
tgordon |
Date |
2007-08-20 |
Time |
16:08 |
Sent To |
|
|
Notes |
2007-08-20 16:21:33 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | REFERENCED CODES WITH 2005, 2006 REVISIONS, AND CHAPTER | | 1 CITY OF WEST PALM BEACH AMENDMENTS. | | | | *** DENIED *** | | 1) ENERGY CALCULATIONS LINE 11A STATES AIR HANDLER | | INTERIOR, MECHANICAL PLANS SHOW THE AIR HANDLER IS IN | | THE GARAGE, PLEASE CORRECT ENERGY CALCULATIONS. | | | | 2) MECHANICAL PLANS NOTES STATE "ACCORDING TO | | F.M.C.2004. AS THIS IS A SINGLE FAMILY DWELLING IT | | NEEDS TO COMPLY WITH THE 2004 FBC/RESIDENTIAL, SEE | | R101.2. PLEASE CORRECT. | | | | 3) MECHANICAL PLANS EQUIPMENT SCHEDULE, CAN NOT READ | | THE CONDENSER UNIT MODEL NUMBER, SEE 2004 FBC 106.1.1. | | PLEASE CORRECT. | | | | 4) PLEASE SHOW THE A/C SYSTEM'S SEER IN THE EQUIPMENT | | SCHEDULE. | | | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729 | | E-MAIL: [email protected]. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2007-06-19 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2007-06-19 |
Time |
08:29 |
Rev Time |
0.30 |
Received By |
tgordon |
Date |
2007-06-19 |
Time |
08:29 |
Sent To |
P |
|
Notes |
2007-06-19 08:34:48 | *** DENIED *** | | 1) CLOTHES DRYER VENT TERMINATION MAY NOT DISCHARGE | | NEAR A/C CONDENSER UNIT, SEE 2004 BC/M 501.2 . | | | | 2) SEE MECHANICAL PLANS A/C NOTES STATES ACCORDING TO | | PALM BEACH COUNTY, PERMIT IS BEING APPLIED FOR IN THE | | CITY OF WEST PALM BEACH, PLEASE CORRECT A/C NOTES. | | | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2007-07-05 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2007-07-05 |
Time |
08:27 |
Rev Time |
0.00 |
Received By |
jleech |
Date |
2007-07-05 |
Time |
08:27 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
F |
Date |
2007-10-16 |
|
|
Cont ID |
|
Sent By |
choops |
Date |
2007-10-16 |
Time |
11:54 |
Rev Time |
0.00 |
Received By |
choops |
Date |
2007-10-16 |
Time |
11:54 |
Sent To |
M |
|
Notes |
2007-10-16 11:57:17 | ***FAILED - RESUB #2*** | | | | REPEAT COMMENT: | | | | 1)PROVIDED LETTER REGARDING SUBDIVISION IS | | INSUFFICIENT, PROPERTY CONTROL NUMBERS ARE ISSUED BY | | THE COUNTY REGARDLESS OF A LEGAL SUBDIVISION. | | | | THE PLANNING AND ZONING DEPARTMENT HAS NO RECORD THAT | | THE CITY OF WEST PALM BEACH APPROVED THIS SUBDIVISION. | | THE PROPERTY OWNER SWOULD BE REQUIRED TO APPLY FOR A | | MINOR SUBDIVISION THROUGH THE PLANNING AND ZONING | | DEPARTMENT.HOWEVER THE MINOR SUBDIVISION WILL NOT BE | | APPROVED, AS IT WOULD CREATE A DIMENSIONAL | | NONCONFORMITY AND INCREASE THE NONCONFORMITY WITH | | RESPECT TO DENSITY. | | | | ***LOTS MUST BE UNIFIED AS ONE PARCEL, BACK TO ORIGINAL | | FORM*** ***THIS LOT IS NOT BUILDABLE*** | | | | | | | | QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, ZONING | | TECHNICIAN | | (561)805-6720 | | | | | | | | SENT TO "AD" |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2007-08-10 |
|
|
Cont ID |
|
Sent By |
choops |
Date |
2007-08-10 |
Time |
14:25 |
Rev Time |
0.00 |
Received By |
choops |
Date |
2007-08-10 |
Time |
14:25 |
Sent To |
E |
|
Notes |
2007-08-10 14:35:16 | ***FAILED******RESUB. #1*** | | | | | | 1)INDICATE SETBACK DIMENSIONS FROM A/C EQUIPMENT TO | | THE PROPERTY LINES. (REPEAT COMMENT) | | | | 2)SHOW ELEVATION DIMENSIONS FROM GRADE TO THE | | MIDPOINT OF THE ROOF'S PITCH (REPEAT COMMENT) | | | | 3)PROPOSED DRIVEWAY EXCEEDS MAXIMUM IMPERMEABLE | | SURFACE ALLOWABLE WITHIN THE FRONT YARD.PROPOSED = | | 331.5 SQ. FT. (NOT INCLUDING WALKWAY)ALLOWABLE = | | 318.75 SQ.FT. (INCLUDING FRONT OF WALKWAY THAT EXTENDS | | PAST FRONT EDGE OF GARAGE).PURSUANT TO THE CITY OF | | WEST PALM BEACH ZONING AND LAND DEVELOPMENT | | REGULATIONS, SECTION 94-482(A): | | | | LOCATION AND SURFACE.REQUIRED OFF-STREET PARKING | | SPACES FOR LESS THAN FOUR RESIDENTIAL DWELLING UNITS | | SHALL BE LOCATED ON THE PROPERTY ON WHICH THE UNITS ARE | | CONSTRUCTED. REQUIRED PARKING MAY BE LOCATED IN A FRONT | | YARD; HOWEVER, THE LESSER OF 1,000 SQUARE FEET OR 75 | | PERCENT OF THE FRONT YARD AREA MUST BE LANDSCAPED. | | PARKING AREAS LOCATED IN THE FRONT YARD SHALL BE | | SURFACED WITH A SMOOTH, NONDUSTING SURFACE IN | | COMPLIANCE WITH SUBSECTION 33-485(E). IT SHALL BE A | | VIOLATION OF THIS CHAPTER TO PARK ON ANY UNPAVED AREAS | | AS DESCRIBEDIN THIS ARTICLE. | | | | 4)PROVIDE A DATA TABLE ON THE LANDSCAPE PLAN SHOWING | | THE OPEN SPACE CALCULATIONS, HOW MANY TREES/SHRUBS ARE | | REQUIRED AND HOW MANY ARE PROVIDED. | | | | 5)PROVIDED DEEDS DO NOT PROVIDE PROOF OF A LEGAL | | SUBDIVISION, THEY SIMPLY SHOW THAT THE LOTS WERE INDEED | | SOLD. ***PARCEL APPEARS TO BE ILLEGALLY SUBDIVIDED*** | | EITHER PROVIDE PROOF OF A LEGAL SUBDIVISION OR CONTACT | | THE PLANNING DEPARTMENT (561)822-1435 TO POTENTIALLY | | SUBDIVIDE LEGALLY. | | | | | | QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, ZONING | | TECHNICIAN | | (561)805-6720 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2007-06-12 |
|
|
Cont ID |
|
Sent By |
choops |
Date |
2007-06-12 |
Time |
10:26 |
Rev Time |
0.00 |
Received By |
choops |
Date |
2007-06-12 |
Time |
10:26 |
Sent To |
E |
|
Notes |
2007-06-12 10:33:44 | ***FAILED*** | | | | | | 1)***PARCEL APPEARS TO BE ILLEGALLY SUBDIVIDED*** | | EITHER PROVIDE PROOF OF A LEGAL SUBDIVISION OR CONTACT | | THE PLANNING DEPARTMENT (561)822-1435 TO POTENTIALLY | | SUBDIVIDE LEGALLY.ONCE THIS PROCESS IS COMPLETE OR | | PROOF IS SHOWN...THE FOLLOWING COMMENTS NEED | | ADDRESSED. | | | | 2)PLEASE PROVIDE A LANDSCAPE PLAN THAT INDICATES | | COMPLIANCE WITH SECTION 94-442 OF THE ZONING AND LAND | | DEVELOPMENT REGULATIONS. | | | | 3)PLEASE PROVIDE ELEVATION DIMENSIONS FROM GRADE TO | | THE MIDPOINT OF THE ROOF'S PITCH. | | | | 4)PLEASE PROVIDE 2 COPIES OF AN UPDATED SURVEY | | SHOWING THE SCOPE OF WORK WITH DIMENSIONS AND SETBACK | | DIMENSIONS TO PROPERTY LINES. | | | | 5)SHOW ANY PROPOSED A/C OR MECHANICAL EQUIPMENT ON | | SURVEYS AND SITE PLANS WITH SETBACK DIMENSIONS TO | | PROPERTY LINES. | | | | 6)IS THE DRIVEWAY PROPOSED ON THIS PERMIT?IF SO, | | PROVIDE DIMENSIONS IN DETAIL.IF NOT, DRIVEWAY TO BE | | ON A SEPERATE PERMIT. | | | | | | | | CHRIS HOOPS | | ZONING TECHNICIAN | | 561-805-6720 |
|
|