Plan Review Details - Permit 07060290
Plan Review Stops For Permit 07060290 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2007-09-13 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-09-13 |
Time |
18:31 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-09-13 |
Time |
18:31 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2007-08-22 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-08-22 |
Time |
11:17 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-08-22 |
Time |
11:17 |
Sent To |
|
|
Notes |
2007-08-22 11:18:54 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBCFLORIDA BUILDING CODE 2004 | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | CODE | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | FAC FLORIDA ADMINISTRATIVE CODE | | FSFLORIDA STATUTE | | | | 1.)SEE PREVIOUS LIST.YOU'VE WRITTEN ON THE PRODUCT | | APPROVAL THAT THE BOTTOM CONNECTION IS CONCRETE.THE | | INSTALLATION SCHEDULE STATES THIS IS BLOCK.YOU MAY | | SPECIFY TWO DIFFERENT SUBSTRATES FOR TOP AND BOTTOM BY | | WRITING, FOR INSTANCE, CBS/PC.THIS WOULD INDICATE A | | BLOCK SUBSTRATE AT THE TOP, POURED CONCRETE AT THE | | BOTTOM. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2007-07-17 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-07-17 |
Time |
16:35 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-07-17 |
Time |
16:35 |
Sent To |
|
|
Notes |
2007-07-17 16:36:15 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBCFLORIDA BUILDING CODE 2004 | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | CODE | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | FAC FLORIDA ADMINISTRATIVE CODE | | FSFLORIDA STATUTE | | | | | | 1.)SEE HIGHLIGHTED PRODUCT APPROVAL.C4 CONNECTION | | CANNOT BE USED WITH DESIGN PRESSURE SPECIFIED, CONCRETE | | BLOCK SUBSTRATE. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2007-06-19 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-06-19 |
Time |
13:24 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-06-19 |
Time |
13:24 |
Sent To |
|
|
Notes |
2007-06-19 13:25:20 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBC FLORIDA BUILDING CODE 2004 | | FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | | SHUTTER PERMIT APPLICATION, ONLY CHECKED ITEMS APPLY | | | | ____1.A NOTICE OF COMMENCEMENT MUST BE FILED WITH | | THE CLERK OF COURTS BEFORE A PERMIT CAN BE ISSUED, | | FS713.13. | | | | ____2.PROVIDE BUILDING HEIGHT ON THE PLAN.DESIGN | | PRESSURES FOR BUILDINGS OVER 60FEET ARE REQUIRED TO BE | | DESIGNED USING ASCE7, FBC1609.1.1 AND MUST BE DONE BY A | | DESIGN PROFESSIONAL. DOCUMENTS PREPARED BY AN ENGINEER | | AND SUBMITTED FOR PUBLIC RECORD ARE TO BE SIGNED SEALED | | ORIGINALS FAC61G15-23.002. | | | | ____3.PROVIDE A COPY OF THE CONDO ASSOCIATION | | APPROVAL. | | | | _XX_4.COMPLETE THE ATTACHED INSTALLATION SCHEDULE | | OR PROVIDE ALL INFORMATION TO SHOW CODE COMPLIANCE IN | | ANOTHER FORMAT. | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2007-09-10 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-09-10 |
Time |
16:15 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-09-10 |
Time |
16:15 |
Sent To |
B |
|
Notes |
2007-09-10 16:15:33 | TO "SHILL" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2007-08-14 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-08-14 |
Time |
16:42 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-08-14 |
Time |
16:42 |
Sent To |
B |
|
Notes |
2007-08-14 16:42:39 | TO "SHILL" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2007-07-11 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-07-11 |
Time |
15:14 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-07-11 |
Time |
15:14 |
Sent To |
B |
|
Notes |
2007-07-11 15:14:45 | TO "SHILL" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2007-06-19 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-06-19 |
Time |
13:25 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-06-12 |
Time |
10:42 |
Sent To |
|
|
Notes |
2007-06-12 10:43:09 | TO "MISC" BOX#1 |
|
|
|
Account Summary | Usage Policy | Privacy Policy