Plan Review Stops For Permit 07060182 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2007-11-09 |
|
|
Cont ID |
|
Sent By |
jjohnsto |
Date |
2007-11-09 |
Time |
10:53 |
Rev Time |
1.00 |
Received By |
jjohnsto |
Date |
2007-11-09 |
Time |
10:53 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2007-09-11 |
|
|
Cont ID |
|
Sent By |
jjohnsto |
Date |
2007-09-11 |
Time |
10:38 |
Rev Time |
0.00 |
Received By |
jjohnsto |
Date |
2007-09-11 |
Time |
08:00 |
Sent To |
|
|
Notes |
2007-09-11 10:37:02 | CONSTRUCTION SERVICES DEPARTMENT | | 200 SECOND STREET, 3RD FLOOR, WEST PALM BEACH, | | FLORIDA33401 | | TEL:561-805-6713FAX: | | 561-805-6731 | | | | JAMES JOHNSTON,CBO PERMIT NO 07060182 | | BUILDING PLAN EXAMINERII PROJECT COOLING TOWER | | REPLACEMENT | | E-MAIL:JJOHNSTON @WPB.ORG ADDRESS 515 N. FLAGLER | | DRIVE | | CONTRACTOR AIRSTRON, INC. | | DATE SEPTEMBER 11, 2007 | | STRUCTURALPLANREVIEW (2) F.S. | | 713.13 NOTICE OF COMMENCEMENT TO BE FILED WITH THE | | CLERK OF COURT | | F.S.713.13 (2) IF THE WORK DESCRIBED | | IN THE NOTICE OF COMMENCEMENT IS NOT COMMENCED WITHIN | | 90 DAYS AFTER RECORDING THEREOF, SUCH NOTICE IS NULL | | AND VOID | | RESUBMIT A NEWLY RECORDED NOTICE OF COMMENCEMENT PRIOR | | TO PERMIT ISSUANCE. | | | | (4) SHEETS-1 PROVIDE WIND IMPORTANCE FACTOR ON DATA | | | | | | (5) SHEET S-2 SUBMIT DETAIL OFCOOLING TOWER WITH ALL | | SUPPORTS. IDENTIFY HIGHEST POINT OF | | | | TOWER FROM ROOF SLAB | | | | (6) SHEET S-1 INFORMATION ON ARBAB ENGINEERING, INC. | | SHEET 10 OF 25 DOES NOT MATCH | | | | SHEET S-1DRAWINGS | | | | (7) SHEET S-2 FBC 1905.1.1STRENGTH OF CONCRETE | | STATE DESIGN STRENGTH FOR FORMED CONCRETE COLUMN | | | | (8) SHEET S-1 PROVIDE INFORMATION STATING? | | MODIFICATION ? OF STUB COLUMN | | | | (9) SHEET S-2 SEE PROTECTION OF METALS AS | | SPECIFIED ON SHEET M-2 ?TYPICAL ROOF MOUNTED | | | | PIPING SERVICE SUPPORT INSTALLATION?PROVIDE | | PROTECTION FOR STRUCTURAL SUPPORTS | | | | COMPATIBLE WITH THAT SPECIFIED ON SHEET M-2. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2007-07-18 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2007-07-18 |
Time |
20:47 |
Rev Time |
0.77 |
Received By |
jwitmer |
Date |
2007-07-18 |
Time |
20:47 |
Sent To |
PC |
|
Notes |
2007-07-18 21:08:27 | 515 N. FLAGLER DR 07060182 | | | | BUILDING PLAN REVIEW | | PERMIT: 07060182 | | ADD: 515 N FLAGLER DR | | CONT: AIRSTRON, INC | | TEL: (954)923-1654 | | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | W/ 2006 FBC REVISIONS | | * WEST PALM BEACH AMENDMENTS | | | | REVIEW | | ACTION: DENIED | | | | 1)--- VERY IMPORTANT STATEMENT --- | | PLEASE DO NOT IGNORE! | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL | | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH | | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE | | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE | | FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR | | YOUR ANTICIPATED COOPERATION. | | | | 2) FL S S 713.13NOTICE OF COMMENCEMENT, TO BE FILED | | WITH THE CLERK OF THE COURT.NOTE: 713.13(2) IF THE | | WORK DESCRIBED IN THE NOTICE OFCOMMENCEMENT IS NOT | | ACTUALLYCOMMENCED WITHIN 90 DAYS AFTER THE RECORDING | | THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6) | | THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE | | CONSTRUCTION SITE BEFORE THE FIRST INSPECTION. | | | | 3 ) 110.2* W. P. B. ADMINISTRATIVE CODE, INFORMATION | | THAT IS REQUIRED FOR RECORD KEEPING & FOR CERTIFICATE | | OF OCCUPANCY: | | A) THE EDITION OFTHE CODE UNDER WHICH THE PROJECT IS | | DESIGNED. 2004 FBC BUILDING W/ 2006 REVISIONS | | | | 4 2004 FL. BLD CODE 1603.1.4 THE FOLLOWING INFORMATION | | RELATED TO WIND SHALL BE SHOWN ON THE CONSTRUCTION | | DRAWINGS, | | 1)- BASIC WIND SPEED, MPH | | 2)- WIND IMPORTANCE FACTOR, & BUILDING | | CATEGORY | | 3)- WIND EXPOSURE | | 4)- COMPONENTS & CLADDING, THE DESIGN | | WIND PRESSURES IN TERMS OF PSF. | | S-2 INDICATES THAT THE DESIFN IS TO ASCE 7-02 BUT | | AFTEWARDS COMPLIES TO THE 2001 FBC, PLEASE CORRECT. | | MISSING THE WIND EXOOSURE, AND THE BUILDING CATEGORY, | | HOW HIGH ABOVE GRADE IS THE COOLING TOWER? THERE MAY BE | | ADJUSTMENT FACTORS. | | | | BUILDING PLAN REVIEW II | | JIM WITMER C. B. O. | | | | TEL: (561)805-6715 | | FAX: (561)659-8026 | | E-MAIL: [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2007-08-31 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2007-08-31 |
Time |
16:30 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2007-08-31 |
Time |
16:30 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2007-06-21 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2007-06-21 |
Time |
20:00 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2007-06-21 |
Time |
20:00 |
Sent To |
|
|
Notes |
2007-06-21 20:01:16 | *** UNSAT *** | | | | 1) NOTE:PLEASE SEE THE SUBMITTED DOCUMENTS REQUIRE | | THE CODES TO BE STATED ON PLANS. | | PLEASE SEE THE FOLLOWING ARE REQUIRED FOR ELECTRICAL | | AND OTHERS WILL BE REQUIRED FOR OTHER TRADES. PLEASE | | KNOW AS OF DECEMBER 8TH, 2006 THE STATE ADOPTED THE | | 2006 REVISIONS TO THE 2004 FBC AND THE 2005 NFPA-70. | | PLEASE LIST THE FOLLOWING | | 2004 FBC W/ 2006 REVISIONS. | | 2005 NFPA-70 | | | | 2) NOTE: PLEASE PROVIDE INFORMATION FOR ANY INCREASE OF | | LOADS FROM EXISTING EQUIPMENT TO NEW EQUIPMENT. THIS | | INFORMATION SHOULD BE STATED ON PLANS. | | 220. | | FBC 106.1.2 | | | | 3) NOTE: PLEASE SEE RISER MENTIONS FOR GUTTER TO BE | | REPLACE PER NEC HOWEVER NO SIZE OR DIMENSIONS ARE SHOWN | | AS NEEDED PER NEC 366. | | FBC 106.1.2 | | | | * ** IMPORTANT** | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | PICKED UP FOR CORRECTIONS, PLEASE BE | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | SHEETS AND ONLY INSERT NEW REVISED | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | AND STAMPING. DO NOT LEAVE ANY | | OLD/VOIDED SHEETS IN SETS. | | PLEASE KNOW ONLY ONE SET OF THE | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | FOR REFERENCE. | | THIS WILL HELP IN THE REVIEW PROCESS AND | | AVOID ANY DELAYS. | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | REVIEWER. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW II | | CONSTRUCTION SERVICES DEPT. | | CITY OF WEST PALM BEACH | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2007-11-05 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-11-05 |
Time |
12:10 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-11-05 |
Time |
12:10 |
Sent To |
|
|
Notes |
2007-11-05 12:11:01 | WAITING FOR "COMM" BD |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2007-08-07 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2007-08-07 |
Time |
12:50 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2007-08-07 |
Time |
12:50 |
Sent To |
|
|
Notes |
2007-08-31 10:16:04 | TO "COMM" BD#1 | 2007-08-07 12:50:52 | | | | | WAITING FOR COM BOARD./WRT. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2007-07-18 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2007-07-18 |
Time |
20:48 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2007-06-08 |
Time |
14:24 |
Sent To |
|
|
Notes |
2007-06-21 14:58:47 | TO "COMM" BD#36 | 2007-06-08 14:26:28 | WAITING FOR "COMM" BD |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2007-09-07 |
|
|
Cont ID |
|
Sent By |
rregueir |
Date |
2007-09-07 |
Time |
18:00 |
Rev Time |
0.00 |
Received By |
rregueir |
Date |
2007-09-07 |
Time |
17:38 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2007-07-02 |
|
|
Cont ID |
|
Sent By |
rregueir |
Date |
2007-07-02 |
Time |
17:38 |
Rev Time |
0.00 |
Received By |
rregueir |
Date |
2007-07-02 |
Time |
17:30 |
Sent To |
|
|
Notes |
2007-07-02 17:38:52 | ---------------DENIED------------------- | | | | FBC 2004 CODE FAMILY W/2006 REVISIONS | | FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH | | NFPA 214-96 | | | | 1. SCHEMATIC AND INLET DETAILS SECTION IS NOT LEGIBLE. | | PLEASE PROVIDE MARLEY SCHEMATIC THAT IS OF LEGIBLE | | SIZE, QUALITY AND CLARITY. FBC 106.1.3 | | | | 2. DETAILS FOR PIPE STANDS AND CLAMPS: SUFFICIENT | | INFORMATION IS NOT PROVIDED WITH DETAILS AS SHOWN ON | | PLAN. PROVIDE ALL RELEVANT INFORMATION ON PLANS, SUCH | | AS SIZE, FASTENERS TO BE USED, SPACING OF SUPPORTS, | | ETC. RATHER THAN REFERRING TO A CATALOG WHICH WAS NOT | | PROVIDED WITH THE APPLICATION. FBC 106.1.1, 106.1.3 | | | | 3. PROVIDE MANUFACTURER'S SUBMITTAL DATA AND | | INSTALLATION INSTRUCTIONS FOR THE COOOLING TOWER. FBC,M | | 908.1 | | | | 4. PROVIDE WIND LOAD CALCULATIONS FOR THE COOLING | | TOWER, SUPPORTS AND ANCHORING SHOWING THE DESIGN TO BE | | ADEQUATE FOR THE WIND ZONE AND EXPOSURE CATEGORY OF THE | | JOB LOCATION PER FBC,M 301.13 AND FBC CH.16. | | | | 5. PLEASE REFERENCE CODES IN EFFECT AT TIME OF PERMIT | | APPLICATION: FBC 2004 W/2006 REVISIONS, NFPA 214-96. | | | | NOTE: ADDITIONAL COMMENTS ARE POSSIBLE PENDING THE | | INCLUSION OF INFORMATION WHICH IS MISSING AT THIS | | TIME. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT: | | RONALD J REGUEIRO | | 561.805.6719 | | [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2007-11-09 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2007-11-09 |
Time |
13:43 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2007-11-09 |
Time |
13:43 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2007-09-21 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2007-09-21 |
Time |
06:51 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2007-09-20 |
Time |
18:56 |
Sent To |
|
|
Notes |
2007-09-21 07:03:40 | DENIED | | REFERENCE: FBC-2004 PLUMBING | | CITY MUNICIPAL CODE | | | | 1. NEW P-1 SHEET SHOWS THE COOLING TOWER DRAIN AND | | OVERFLOW DRAINING TO THE SAME SANITARY RISER STACK. THE | | DRAIN SHALL DRAIN TO THE SANITARY, BUT THE OVERFLOW | | SHALL DRAIN TO STORM. IT CAN BE PIPED TO THE NEAREST | | ROOF DRAIN. ARTICLE III SECTION 90-125(5). PLEASE | | CORRECT THE PLUMBING SHEET TO REFLECT THESE | | REQUIREMENTS. | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 805-6731 | | E-MAIL [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
N |
Date |
2007-07-14 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2007-07-14 |
Time |
08:40 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2007-07-14 |
Time |
08:40 |
Sent To |
|
|
Notes |
2007-07-14 08:40:42 | PLUMBING PERMIT REQUIRED |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
N |
Date |
2007-06-26 |
|
|
Cont ID |
|
Sent By |
mflis |
Date |
2007-06-26 |
Time |
10:20 |
Rev Time |
0.00 |
Received By |
mflis |
Date |
2007-06-26 |
Time |
10:20 |
Sent To |
|
|
Notes |
2007-06-26 10:20:54 | ZONING REVIEW: NOT REQUIRED | | | | * MECH REPLACEMENT ONLY; NO EXTERIOR MODS | | | | MATT FLIS - 822-1445 |
|
|