Plan Review Stops For Permit 07060181 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
P |
Date |
2007-08-23 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-08-23 |
Time |
18:41 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-08-23 |
Time |
18:41 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
F |
Date |
2007-08-08 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-08-08 |
Time |
16:03 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-08-08 |
Time |
16:03 |
Sent To |
|
|
Notes |
2007-08-08 16:10:32 | ****CORRECTIONS**** | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | FBC FLORIDA BUILDING CODE 2004 | | FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL | | | | FOURTH REVIEW BUT FIRST REVIEW FOR INSTALLATION | | SCHEDULE | | | | 1.)SHUTTER MOUNTING CONNECTION TYPE (INSTALLATION | | SCHEDULE) SHOULD BE THE CONNECTION TYPE, C1 THROUGH C5, | | SEE SHEET 5 OF THE PRODUCT APPROVAL. | | | | 2.)INSTALLATION SCHEDULE STATES THAT YOU WILL BE | | INSTALLING TAPCONS.THERE ARE TWO TYPES, ELCO AND ITW, | | AND YOU HAVE HIGHLIGHTED ELCO BUT HIGHLIGHTED ANCHORING | | FOR ITW, WHICH REQUIRES 6" ANCHOR SPACING, BUT YOU | | SPECIFY 12".COMPLETE INFORMATION REQUIRED ON THE | | INSTALL SCHEDULE (SEE NOTE ON THE BOTTOM OF THE | | INSTALLATION SCHEDULE WHICH STATES "ANCHOR TYPE MUST BE | | SPECIFIC, EG THERE ARE DIFFERENT TYPES OF TAPCONS WITH | | DIFFERENT STRENGTH VALUES"THERE IS INCOMPLETE | | INFORMATION ON THE SCHEDULE AND INCONSISTENT | | INFORMATION ON THE PRODUCT APPROVAL. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2007-07-27 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-07-27 |
Time |
11:41 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-07-27 |
Time |
11:41 |
Sent To |
|
|
Notes |
2007-07-27 11:41:12 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBC FLORIDA BUILDING CODE 2004 | | FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL FBC* CITY | | OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 SHUTTER | | PERMIT APPLICATION, ONLY CHECKED ITEMS APPLY | | | | FROM PREVIOUS LIST: | | | | _XX_4.COMPLETE THE ATTACHED INSTALLATION SCHEDULE | | OR PROVIDE ALL INFORMATION TO SHOW CODE COMPLIANCE IN | | ANOTHER FORMAT. | | | | 2ND REVIEW - THE INSTALLATION SCHEDULE WAS RETURNED | | BLANK, WITH SOME INFORMATION COMPLETED AT THE TOP | | (DATE, ADDRESS, BLDG HEIGHT, ETC.).ONLY ONE | | SUBMITTED, WITH PAGES FROM THE PRODUCT APPROVAL | | ATTACHED.ALL INFORMATION REQUIRED TO ASSIST IN PLAN | | REVIEW AND INSPECTIONS.TWO SETS OF ALL PERMIT | | DOCUMENTS REQUIRED. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2007-07-06 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-07-06 |
Time |
09:23 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-07-06 |
Time |
09:23 |
Sent To |
|
|
Notes |
2007-07-06 09:26:42 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBC FLORIDA BUILDING CODE 2004 | | FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL FBC* CITY | | OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | SHUTTER PERMIT APPLICATION, ONLY CHECKED ITEMS APPLY | | | | FROM PREVIOUS LIST: | | | | _XX_4.COMPLETE THE ATTACHED INSTALLATION SCHEDULE | | OR PROVIDE ALL INFORMATION TO SHOW CODE COMPLIANCE IN | | ANOTHER FORMAT. | | | | 2ND REVIEW - THE INSTALLATION SCHEDULE WAS RETURNED | | BLANK, WITH SOME INFORMATION COMPLETED AT THE TOP | | (DATE, ADDRESS, BLDG HEIGHT, ETC.).ONLY ONE | | SUBMITTED, WITH PAGES FROM THE PRODUCT APPROVAL | | ATTACHED.ALL INFORMATION REQUIRED TO ASSIST IN PLAN | | REVIEW AND INSPECTIONS.TWO SETS OF ALL PERMIT | | DOCUMENTS REQUIRED. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2007-06-19 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-06-19 |
Time |
10:55 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-06-19 |
Time |
10:55 |
Sent To |
|
|
Notes |
2007-06-19 10:56:28 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBC FLORIDA BUILDING CODE 2004 | | FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | | SHUTTER PERMIT APPLICATION, ONLY CHECKED ITEMS APPLY | | | | ____1.A NOTICE OF COMMENCEMENT MUST BE FILED WITH | | THE CLERK OF COURTS BEFORE A PERMIT CAN BE ISSUED, | | FS713.13. | | | | ____2.PROVIDE BUILDING HEIGHT ON THE PLAN.DESIGN | | PRESSURES FOR BUILDINGS OVER 60FEET ARE REQUIRED TO BE | | DESIGNED USING ASCE7, FBC1609.1.1 AND MUST BE DONE BY A | | DESIGN PROFESSIONAL. DOCUMENTS PREPARED BY AN ENGINEER | | AND SUBMITTED FOR PUBLIC RECORD ARE TO BE SIGNED SEALED | | ORIGINALS FAC61G15-23.002. | | | | ____3.PROVIDE A COPY OF THE CONDO ASSOCIATION | | APPROVAL. | | | | _XX_4.COMPLETE THE ATTACHED INSTALLATION SCHEDULE | | OR PROVIDE ALL INFORMATION TO SHOW CODE COMPLIANCE IN | | ANOTHER FORMAT. | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2007-08-16 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-08-16 |
Time |
08:29 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-08-16 |
Time |
08:29 |
Sent To |
B |
|
Notes |
2007-08-16 08:30:05 | TO "SHILL" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2007-08-03 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-08-03 |
Time |
08:58 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-08-03 |
Time |
08:58 |
Sent To |
B |
|
Notes |
2007-08-03 08:58:47 | TO "SHILL" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2007-07-17 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-07-17 |
Time |
09:15 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-07-17 |
Time |
09:15 |
Sent To |
B |
|
Notes |
2007-07-17 09:16:18 | TO "SHILL" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2007-06-27 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-06-27 |
Time |
15:05 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-06-27 |
Time |
15:05 |
Sent To |
B |
|
Notes |
2007-06-27 15:05:56 | TO "SHILL' DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2007-06-19 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-06-19 |
Time |
10:56 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-06-08 |
Time |
14:46 |
Sent To |
|
|
Notes |
2007-06-08 14:46:50 | TO "MISC" BOX#1 |
|
|