Plan Review Details - Permit 07051093
Plan Review Stops For Permit 07051093 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2007-06-04 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-06-04 |
Time |
09:34 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-06-04 |
Time |
09:34 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2007-06-01 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-06-01 |
Time |
14:35 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-06-01 |
Time |
14:35 |
Sent To |
|
|
Notes |
2007-06-01 14:47:44 | ****CORRECTIONS**** | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBCFLORIDA BUILDING CODE 2004 | | FBC EBFLORIDA BUILDING CODE 2004 | | EXISTING BUILDING CODE | | FBC*CITY OF WEST PALM BEACH | | AMENDMENTS TO THE FBC2004 | | | | FROM PREVIOUS LIST: | | | | _XX_ 6.)ON THE TILE PRODUCT APPROVAL, INDICATE WHICH | | METHOD OF ATTACHMENT YOU ARE USING. | | | | 2ND REVIEW - IT IS NOT CLEAR WHICH METHOD OF ATTACHMENT | | YOU ARE USING.TWO SETS OF THE ROOF TILE PRODUCT | | APPROVAL WERE SUBMITTED.ONE SET HAS BOTH "1 #8 SCREW" | | AND "2 #8 SCREW" HIGHLIGHTED.THE OTHER SET HAS "1 #8 | | SCREW" HIGHLIGHTED AND "2 #8 SCREW" CIRCLED IN INK. | | WHICH METHOD ARE YOU PROPOSING?IF YOUR INTENTION IS | | TO USE 1 #8 SCREW, SUBMIT CALCULATIONS IN ACCORDANCE | | WITH RAS127. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2007-05-30 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-05-30 |
Time |
13:56 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-05-30 |
Time |
13:55 |
Sent To |
|
|
Notes |
2007-05-30 13:57:39 | ****CORRECTIONS**** | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBCFLORIDA BUILDING CODE 2004 | | FBC EBFLORIDA BUILDING CODE 2004 | | EXISTING BUILDING CODE | | FBC*CITY OF WEST PALM BEACH | | AMENDMENTS TO THE FBC2004 | | | | ROOFING PERMIT; ONLY CHECKED ITEMS APPLY | | | | ____1.)A NOTICE OF COMMENCEMENT MUST BE FILED WITH | | THE CLERK OF COURTS PRIOR TO PERMIT PICKUP, FS713.13. | | | | _XX_2.)CONTRACTOR IS TO PROVIDE THE FOLLOWING | | INFORMATION ON THE APPLICATION; MEAN ROOF HEIGHT, ROOF | | PITCH, ROOF DECK TYPE, AREA OF EACH ROOF TYPE. | | | | _XX_3.)ON THE APPLICATION, STATE THE TYPE OF | | EXISTING ROOF. | | | | ____4.)FOR THE FLAT DECK, SELECT THE APPROVED | | ASSEMBLY YOU ARE USING.ALSO INDICATE WHICH FASTENER | | YOU ARE USING IF THE OPTIONS HAVE DIFFERENT PRESSURE | | LIMITATIONS. | | | | ____5.)FOR THE FLAT DECK, SPECIFY THE ENHANCED | | FASTENING FOR CORNER AND PERIMETER ZONES. | | | | _XX_ 6.)ON THE TILE PRODUCT APPROVAL, INDICATE WHICH | | METHOD OF ATTACHMENT YOU ARE USING. |
|
|
|