Plan Review Details - Permit 07051008
Plan Review Stops For Permit 07051008 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2007-07-31 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-07-31 |
Time |
18:21 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-07-31 |
Time |
18:21 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2007-07-16 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-07-16 |
Time |
18:29 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-07-16 |
Time |
18:29 |
Sent To |
|
|
Notes |
2007-07-16 18:31:48 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBCFLORIDA BUILDING CODE 2004 | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | CODE | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC* | | CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 FAC | | FLORIDA ADMINISTRATIVE CODE | | FSFLORIDA STATUTE | | | | | | 1.)CBS WAS SPECIFIED ON THE INSTALLATION SCHEDULE. | | WALL MOUNT 1 REQUIRES A POURED CONCRETE SUBSTRATE. | | PLEASE REVISE EITHER THE SUBSTRATE OR THE CONNECTION | | TYPE. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2007-06-28 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-06-28 |
Time |
16:48 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-06-28 |
Time |
16:48 |
Sent To |
|
|
Notes |
2007-06-28 16:49:29 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBCFLORIDA BUILDING CODE 2004 | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | CODE | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | FAC FLORIDA ADMINISTRATIVE CODE | | FSFLORIDA STATUTE | | | | | | 1.)ANCHOR SPACING ON THE CHARTS IS FOR 3 1/2" EDGE | | DISTANCE.ON THE INSTALLATION SCHEDULE, YOU'VE | | SPECIFIED 3", WHICH REQUIRES A FACTOR OF .83.SEE | | OPENINGS 6 AND 7, WALL MOUNT 4, 10" SPECIFIED BUT THAT | | SHOULD BE MULTIPLIED BY .83 FOR CORRECT ANCHOR | | SPACING. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2007-06-18 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-06-18 |
Time |
15:23 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-06-18 |
Time |
15:23 |
Sent To |
|
|
Notes |
2007-06-18 15:24:08 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBC FLORIDA BUILDING CODE 2004 | | FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | | SHUTTER PERMIT APPLICATION, ONLY CHECKED ITEMS APPLY | | | | ____1.A NOTICE OF COMMENCEMENT MUST BE FILED WITH | | THE CLERK OF COURTS BEFORE A PERMIT CAN BE ISSUED, | | FS713.13. | | | | ____2.PROVIDE BUILDING HEIGHT ON THE PLAN.DESIGN | | PRESSURES FOR BUILDINGS OVER 60FEET ARE REQUIRED TO BE | | DESIGNED USING ASCE7, FBC1609.1.1 AND MUST BE DONE BY A | | DESIGN PROFESSIONAL. DOCUMENTS PREPARED BY AN ENGINEER | | AND SUBMITTED FOR PUBLIC RECORD ARE TO BE SIGNED SEALED | | ORIGINALS FAC61G15-23.002. | | | | ____3.PROVIDE A COPY OF THE CONDO ASSOCIATION | | APPROVAL. | | | | _XX_4.COMPLETE THE ATTACHED INSTALLATION SCHEDULE | | OR PROVIDE ALL INFORMATION TO SHOW CODE COMPLIANCE IN | | ANOTHER FORMAT. | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2007-07-19 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-07-19 |
Time |
13:05 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-07-19 |
Time |
13:05 |
Sent To |
B |
|
Notes |
2007-07-19 13:06:26 | TO "SHILL" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2007-07-12 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-07-12 |
Time |
08:49 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-07-12 |
Time |
08:49 |
Sent To |
B |
|
Notes |
2007-07-12 08:49:44 | TO "SHILL" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2007-06-22 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-06-22 |
Time |
09:42 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-06-22 |
Time |
09:42 |
Sent To |
B |
|
Notes |
2007-06-22 09:42:20 | TO "SHILL" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2007-06-18 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-06-18 |
Time |
15:24 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-05-29 |
Time |
09:17 |
Sent To |
|
|
Notes |
2007-05-29 09:17:39 | TO "MISC" BOX#1 |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |