| BUILDING PLAN REVIEW |
| PERMIT: 07050952 |
| ADD: 439 NORTHWOOD RD |
| CONT: KDN CONSTRUCTION SERVICES, LLC |
| TEL: (561)662-1002 |
| |
| FL BLD CODE= 2004 FLORIDA BUILDING CODE |
| W/ 2006 FBC REVISIONS |
| * WEST PALM BEACH AMENDMENTS |
| |
| REVIEW |
| ACTION: DENIED |
| |
| 1)--- VERY IMPORTANT STATEMENT --- |
| PLEASE DO NOT IGNORE! |
| WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & |
| REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL |
| LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH |
| A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE |
| SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE |
| FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR |
| YOUR ANTICIPATED COOPERATION. |
| |
| 2) FL.S. S. 713.13 NOTICE OF COMMENCEMENT, TO BE |
| FILED WITH THE CLERK OF THE COURT.NOTE: 713.13(2) IF |
| THE WORK DESCRIBED IN THE NOTICE OF COMMENCEMENT IS NOT |
| ACTUALLYCOMMENCED WITHIN 90 DAYS AFTER THE RECORDING |
| THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6) |
| THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE FL |
| CONSTRUCTION SITE BEFORE THE FIRST INSPECTION. |
| |
| 3)A THOROUGH REVIEW CAN NOT BE MADE AT THIS TIME, AS |
| A RESULT OF THE ADDITIONAL INFORMATION REQUESTED |
| ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF |
| THIS REVIEW. |
| NEITHER THE PERMIT APPLICATION NOR THE PLAN INDICATES |
| THIS IS A CHANGE OF OCCUPANCY. SITE PLAN INDICATES THIS |
| IS A RESIDENCY WHILE SHEET 1 INDICATES IT IS A DETACHED |
| GARAGE W/ LOFT? IT APPEARS THAT THIS IS A CHANGE OF |
| OCCUPANCY FROM A RESIDENCE TO POSSIBLY BUSINESS OR |
| MERCANTILE? PLEASE PROVIDE ADDITIONAL INFORMATION. |
| 106.1.2. |
| 110.2* W. P. B. ADMINISTRATIVE CODE, INFORMATION THAT |
| IS REQUIRED FOR RECORD KEEPING & FOR CERTIFICATE OF |
| OCCUPANCY: |
| A) THE EDITION OF THE CODE UNDER WHICH THE PROJECT WAS |
| DESIGNED. |
| 2004 FBC BUILDING W/ 2006 AMENDMENTS |
| 2004 EXISTINGBUILDING CODE W? 2006 AMENDMENTS LIST TO |
| WHAT LEVEL OF ALTERATIONS WILL BE COMPLETED UNDER THIS |
| PERMIT? |
| EXISTING BUILDING CODE : CHAPTER 8 CHANGE OF OCCUPANCY |
| : CHAPTER 9 ADDITIONS |
| B) THE USE AND OCCUPANCY, IN ACCORDANCE |
| WITH THE PROVISIONS OF CHAPTER 3. |
| C) THE TYPE OF CONSTRUCTION AS DEFINED |
| IN CHAPTER 6, TABLE 601. |
| D) THE OCCUPANT LOAD, SEE 1004. |
| E) IF AN AUTOMATIC SPRINKLER SYSTEM IS |
| PROVIDED. |
| F) WHETHER THE SPRINKLER SYSTEM IS REQUIRED. |
| G) ANY SPECIAL STIPULATIONS & CONDITIONS OF THE |
| BUILDING PERMIT. |
| H) TOTAL SQ FT UNDER ROOF |
| |
| 4) 109.3.10* IMPACT OF CONSTRUCTION.ALL CONSTRUCTION |
| ACTIVITY REGULATED BY THIS CODE SHALL BE PERFORMED IN A |
| MANNER SO AS NOT TO ADVERSELY IMPACT THE CONDITION OF |
| ADJACENT PROPERTY, UNLESS SUCH ACTIVITY IS PERMITTED TO |
| AFFECT SAID PROPERTY PURSUANT TO A CONSENT BY |
| THE APPLICABLE PROPERTY OWNER, UNDER TERMS & CONDITIONS |
| AGREEABLE TO THE APPLICABLE PROPERTY OWNER. THIS |
| INCLUDES BUT IS NOT LIMITED TO THE CONTROL OF DUST, |
| NOISE, WATER OR DRAINAGE RUN-OFF, DEBRIS, AND THE |
| STORAGE OF CONSTRUCTION MATERIALS. NEW CONSTRUCTION |
| ACTIVITY SHALL NOT ADVERSELY IMPACT HISTORIC SURFACE |
| WATER DRAINAGE FLOWS SERVING ADJACENT PROPERTIES, & MAY |
| REQUIRE SPECIAL DRAINAGE DESIGN COMPLYING WITH |
| ENGINEERING STANDARDS TO PRESERVE THE POSITIVE PATTERNS |
| OF THE AFFECTED SITES. ACCORDINGLY, DEVELOPERS, |
| CONTRACTORS, AND OWNERS OF ALL NEW RESIDENTIAL |
| DEVELOPMENT, INCLUDING ADDITIONS, POOLS, |
| PATIOS, DRIVEWAYS, DECKS, OR SIMILAR ITEMS, ON EXISTING |
| PROPERTIES RESULTING IN A DECREASE IN EXCESS OF 800SQ |
| FT OF PERMEABLE LAND AREA ON ANY PARCEL SHALL AS A |
| PERMIT CONDITION, PROVIDE A PROFESSIONALLY PREPARED |
| DRAINAGE PLAN CLEARLY INDICATING COMPLIANCE WITH THIS |
| PARAGRAPH. UPON COMPLETION OF THE IMPROVEMENT, A |
| CERTIFICATE FROM A LICENSED ENGINEER SHALL BE SUBMITTED |
| TO THE INSPECTOR IN ORDER TO RECEIVE APPROVAL OF THE |
| FINAL INSPECTION. |
| |
| 5) 109.3.10.1 HURRICANE PROTECTION. IT SHALL BE |
| UNLAWFUL FOR ANY PERSON TO ALLOW CONSTRUCTION RELATED |
| MATERIALS EQUIPMENT AND DEBRIS TO REMAIN LOOSE OR |
| OTHERWISE UNSECURED AT A CONSTRUCTION SITE FROM 24 HRS. |
| AFTER A HURRICANE WATCH HAS BEEN ISSUED UNTIL THE |
| HURRICANE WATCH OR WARNING HAS BEEN LIFTED. ALL SUCH |
| CONSTRUCTION MATERIALS, EQUIPMENT AND DEBRIS SHALL BE |
| EITHER REMOVED FROM THE CONSTRUCTION SITE OR SECURED IN |
| SUCH A MANNER AS TO MINIMIZE THE DANGER OF SUCH |
| CONSTRUCTION MATERIALS, EQUIPMENT AND DEBRIS CAUSING |
| DAMAGE TO PERSONS OR PROPERTY FROM HIGH WINDS. ANY |
| PERSONS WHO FAILS TO COMPLY TO REMOVE OR SECURE THE |
| CONSTRUCTION MATERIALS EQUIPMENT AND DEBRIS WITHIN 24 |
| HRS AFTER A HURRICANE WATCH HAS BEEN ISSUED SHALL BE |
| SUBJECT TO A FINE NOT TO EXCEED $500.00. IN ADDITION |
| TO THE ABOVE, A LICENSED CONTRACTOR WHO VIOLATES THIS |
| SECTION SHALL BE SUBJECT TO DISCIPLINE PURSUANT TO |
| SECTION 113 OF THIS CHAPTER. |
| |
| 6) SHEET 4 INDICATES TWO SEPARATE UNITS LOT 26 & 27, |
| WITH A COMMON WALL. THIS IS A SHARED BEARING WALL OR |
| FIRE WALL BETWEEN TWO LOTS OR PROPERTIES REQUIRING |
| RATINGS OF WALL AND ROOFDECKING . 705.1 WHERE A FIRE |
| WALL ALSO SEPARATES GROUPS THAT ARE REQUIRED TO BE |
| SEPARATED BY A FIRE BARRIER WALL, THE MOST RESTRICTIVE |
| REQUIREMENTS OF EACH SEPARATION SHALL APPLY. FIRE WALLS |
| LOCATED ON LOT LINES SHALL ALSO COMPLY WITH SECTION |
| 503.2 . SUCH FIRE WALLS (PARTY WALLS) SHALL PROVIDE A |
| 4-HOUR FIRE-RESISTANCE RATING AND SHALL BE CONSTRUCTED |
| WITHOUT OPENINGS. |
| |
| 7)FIRE WALLS OR PARTY WALLS,705.5 HORIZONTAL |
| CONTINUITY. |
| FIRE WALLS SHALL BE CONTINUOUS FROM EXTERIOR WALL TO |
| EXTERIOR WALL AND SHALL EXTEND AT LEAST 18 INCHES (457 |
| MM) BEYOND THE EXTERIOR SURFACE OF EXTERIOR WALLS. |
| EXCEPTIONS: |
| 1.FIRE WALLS SHALL BE PERMITTED TO TERMINATE AT |
| THE INTERIOR SURFACE OF COMBUSTIBLE EXTERIOR SHEATHING |
| OR SIDING PROVIDED THE EXTERIOR WALL HAS A |
| FIRE-RESISTANCE RATING OF AT LEAST 1 HOUR FOR A |
| HORIZONTAL DISTANCE OF AT LEAST 4 FEET (1220 MM) ON |
| BOTH SIDES OF THE FIRE WALL . OPENINGS WITHIN SUCH |
| EXTERIOR WALLS SHALL BE PROTECTED BY FIRE ASSEMBLIES |
| HAVING A FIRE PROTECTION RATING OF NOT LESS THAN ? |
| HOUR. |
| 2.FIRE WALLS SHALL BE PERMITTED TO TERMINATE AT |
| THE INTERIOR SURFACE OF NONCOMBUSTIBLE EXTERIOR |
| SHEATHING, EXTERIOR SIDING OR OTHER NONCOMBUSTIBLE |
| EXTERIOR FINISHES PROVIDED THE SHEATHING, SIDING, OR |
| OTHER EXTERIOR NONCOMBUSTIBLE FINISH EXTENDS A |
| HORIZONTAL DISTANCE OF AT LEAST 4 FEET (1220 MM) ON |
| BOTH SIDES OF THE FIRE WALL . |
| 3.FIRE WALLS SHALL BE PERMITTED TO TERMINATE AT |
| THE INTERIOR SURFACE OF NONCOMBUSTIBLE EXTERIOR |
| SHEATHING WHERE THE BUILDING ON EACH SIDE OF THE FIRE |
| WALL IS PROTECTED BY AN AUTOMATIC SPRINKLER SYSTEM |
| INSTALLED IN ACCORDANCE WITH SECTION 903.3.1.1 OR |
| 903.3.1.2 . |
| |
| 9) PLEASE PROVIDE AN EXPLANATION WHY THERE IS NO BEAMS |
| OR BEARING WALLS BEING REMOVED DOWN THE CENTER OF THE |
| BUILDING ON THE DEMO SHEET BUT NEW COLUMNS AND LVL'S |
| ARE BEING REPLACED? |
| |
| 10) SHEET# 8 ALSO HAS INK HAND DRAWN CHANGES ADDED TO |
| THIS SHEET. |
| |
| 11) DISCREPANCY, SHEET# 8 INDICATES 3 NEW MASONARY |
| COLUMNS THAT DO NOT SHOW ON SHEET 8 DETAIL# 2. |
| |
| 12) SHEET 8 DETAIL# 2 ALSO INDICATES THE USE OF 3 1/2" |
| 22 GAUGE METAL STUDS FOR FRAMING, ISN'T THIS CONSIDERD |
| LIGHT GAUGE METAL AND NOT FOR STRUCTURALAPPLICATION? |
| |
| 13) BENEATH THE HORIZONTAL FRAMING MEMBERS THERE |
| APPEARS TO BE METAL SLEEPERS THA WILL BE ATTACHED TO |
| THE EXISTING CONCRETE DECK, IS THIS A SINGLE MEMBER |
| STEEL STUD OR TWO MEMBERS CREATING A BOX BEAM? PROVIDE |
| MORE INFORMATION? |
| |
| 14) ON SHEET 8 DETAIL# 2 PLEASE INDICATE WHERE THE |
| PROPERTY LINE IS LOCATED? |
| |
| 15) 11-4.1.5 ACCESSIBLE BUILDINGS: ADDITIONS. |
| EACH ADDITION TO AN EXISTING BUILDING OR FACILITY SHALL |
| BE REGARDED AS AN ALTERATION. EACH SPACE OR ELEMENT |
| ADDED TO THE EXISTING BUILDING OR FACILITY SHALL COMPLY |
| WITH THE APPLICABLE PROVISIONS OF SECTION 11-4.1.1 TO |
| SECTION 11-4.1.3 , MINIMUM REQUIREMENTS FOR NEW |
| CONSTRUCTION, AND THE APPLICABLE TECHNICAL |
| SPECIFICATIONS OF SECTION 11-4.2 THROUGH SECTION |
| 11-4.35 AND SECTION 11-5 THROUGH SECTION 11-10 . EACH |
| ADDITION THAT AFFECTS OR COULD AFFECT THE USABILITY OF |
| AN AREA CONTAINING A PRIMARY FUNCTION SHALL COMPLY WITH |
| SECTION 11-4.1.6 (2). |
| (2)ALTERATIONS TO AN AREA CONTAINING A PRIMARY |
| FUNCTION. IN ADDITION TO THE REQUIREMENTS OF SECTION |
| 11-4.1.6 (1), AN ALTERATION THAT AFFECTS OR COULD |
| AFFECT THE USABILITY OF OR ACCESS TO AN AREA CONTAINING |
| A PRIMARY FUNCTION SHALL BE MADE SO AS TO ENSURE THAT, |
| TO THE MAXIMUM EXTENT FEASIBLE, THE PATH OF TRAVEL TO |
| THE ALTERED AREA AND THE RESTROOMS, TELEPHONES, AND |
| DRINKING FOUNTAINS SERVING THE ALTERED AREA, ARE |
| READILY ACCESSIBLE TO AND USABLE BY INDIVIDUALS WITH |
| DISABILITIES, UNLESS SUCH ALTERATIONS ARE |
| DISPROPORTIONATE TO THE OVERALL ALTERATIONS TIN TERMS |
| OF COST AND SCOPE. |
| 11-4.1.6(2)ALTERATIONS MADE TO PROVIDE AN ACCESSIBLE |
| PATH OF TRAVEL TO ALTERED AREAS SHALL BE DEEMED |
| DISPROPORTIONATE TO THE OVERALL ALTERATION WHEN THE |
| COST EXCEEDS 20 PERCENT OF THE COST OF THE ALTERATION |
| TO THE PRIMARY FUNCTION AREA. |
| DUTY TO PROVIDE ACCESSIBLE FEATURES IN THE EVENT OF |
| DISPROPORTIONALITY. |
| (1)WHEN THE COST OF ALTERATIONS NECESSARY TO MAKE |
| THE PATH OF TRAVEL TO THE ALTERED AREA FULLY ACCESSIBLE |
| IS DISPROPORTIONATE TO THE COST OF THE OVERALL |
| ALTERATION, THE PATH OF TRAVEL SHALL BE MADE ACCESSIBLE |
| TO THE EXTENT THAT IT CAN BE MADE ACCESSIBLE WITHOUT |
| INCURRING DISPROPORTIONATE COSTS. |
| (2)(A)IN CHOOSING WHICH ACCESSIBLE ELEMENTS TO |
| PROVIDE, PRIORITY SHOULD BE GIVEN TO THOSE ELEMENTS |
| THAT WILL PROVIDE THE GREATEST ACCESS, IN THE FOLLOWING |
| ORDER: |
| (I)AN ACCESSIBLE ENTRANCE ; |
| (II)AN ACCESSIBLE ROUTE TO THE ALTERED AREA: (III) |
| AT LEAST ONE ACCESSIBLE RESTROOM FOR EACH SEX OR A |
| SINGLE UNISEX RESTROOM: |
| (IV)ACCESSIBLE TELEPHONES; |
| (V)ACCESSIBLE DRINKING FOUNTAINS; AND |
| (VI)WHEN POSSIBLE, ADDITIONAL ACCESSIBLE ELEMENTS |
| SUCH AS PARKING, STORAGE, AND ALARMS. |
| |
| 13) THE SITE PLAN DOESN?T INDICATE THE HANDICAPPED |
| PARKING WITH AN ACCESSIBLE AISLE, WALKWAY TO THE |
| ENTRANCE OF THE UNIT. PLEASE PROVIDE THE DETAILS. |
| 11-4.6.3 PARKING SPACES. PARKING ACCESS AISLES MUST BE |
| NO LESS THAN 5 FEET (1524 MM) WIDE AND MUST BE PART OF |
| AN ACCESSIBLE ROUTE TO THE BUILDING OR FACILITY |
| ENTRANCE. TWO ACCESSIBLE SPACES MAY SHARE A COMMON |
| ACCESS AISLE [SEE FIGURE 9 (A)]. THE ACCESS AISLE SHALL |
| BE STRIPED DIAGONALLY TO DESIGNATE IT AS A NO-PARKING |
| ZONE. CURB RAMPS MUST BE LOCATED OUTSIDE OF THE |
| DISABLED PARKING SPACES AND ACCESS AISLES. |
| |
| 16) DISCREPANCY, PLEASE SEE SHEET# 6DETAIL1 SHEET7 IS |
| REVERSED WITH DETAIL1 SHEET 8. PLEASE PROVIDE A |
| CONNECTION DETAIL OF THE NEW 5 1/4X 16 LVL BEAM AT BOTH |
| ENDS. |
| 106.1.2 ADDITIONAL INFORMATION REQUIRED. |
| |
| 17)1203.2 ATTIC SPACES. |
| ENCLOSED ATTICS AND ENCLOSED RAFTER SPACES FORMED WHERE |
| CEILINGS ARE APPLIED DIRECTLY TO THE UNDERSIDE OF ROOF |
| FRAMING MEMBERS SHALL HAVE CROSS VENTILATION FOR EACH |
| SEPARATE SPACE BY VENTILATING OPENINGS PROTECTED |
| AGAINST THE ENTRANCE OF RAIN. BLOCKING AND BRIDGING |
| SHALL BE ARRANGED SO AS NOT TO INTERFERE WITH THE |
| MOVEMENT OF AIR. A MINIMUM OF 1 INCH (25 MM) OF |
| AIRSPACE SHALL BE PROVIDED BETWEEN THE INSULATION AND |
| THE ROOF SHEATHING. |
| |
| 18) 1609.1.4 PROTECTION OF OPENINGS. IN WIND-BORNE |
| DEBRIS REGIONS, EXTERIOR GLAZING THAT RECEIVES POSITIVE |
| PRESSURE IN THE LOWER 60 FEET (18.3 M) IN BUILDINGS |
| SHALL BE ASSUMED TO BE OPENINGS AND THE BALANCE OF |
| GLAZED OPENINGS IN THE REST OF THE BUILDING SHALL BE |
| ASSUMED TO BE ZERO UNLESS SUCH GLAZING THAT RECEIVES |
| POSITIVE PRESSURE IS IMPACT RESISTANT OR PROTECTED WITH |
| AN IMPACT RESISTANT COVERING MEETING THE REQUIREMENTS |
| OF SSTD 12, ASTM E 1886 AND ASTM E 1996, OR MIAMI-DADE |
| TAS 201, 202 AND 203 REFERENCED THEREIN AS FOLLOWS: 1. |
| GLAZED OPENINGS LOCATED WITHIN 30 FEET (9.1 M) OF GRADE |
| SHALL MEET THE REQUIREMENTS OF THE LARGE MISSILE TEST. |
| 2.GLAZED OPENINGS LOCATED MORE THAN |
| 30 FEET (9.1 M) ABOVE GRADE SHALL MEET THE PROVISIONS |
| OF THE SMALL MISSILE TEST. |
| |
| FL BLD CODE 1609.1.4: COMPONENTS & |
| CLADDING, PROVIDE 2 COPIES(3 IF THRESHOLD OR RESIDENT |
| INSPECTOR) OF PRODUCT TESTING REPORTS ,MISSING REPORTS |
| ARE AS FOLLOWS: |
| A) FIXED WINDOWS- STOREFRONT GLASS |
| B) GLAZED SWING DOORS |
| C) HOLLOW CORE METAL DOORS |
| D) MULLIONS |
| E) TRUSS ANCHOR STRAPS AND CONNECTIONS |
| F) STORM SHUTTERS |
| G) PRE-ENGINEEREDA/C STANDS |
| H)ROOF ASSEMBLIES |
| |
| 19) PRODUCT APPROVALS SUBMITTED WITH PERMIT APPLICATION |
| AFTER OCTOBER 1, 2003 ARE REQUIRED TO COMPLY WITH THE |
| FLORIDA PRODUCT APPROVAL SYSTEM. FOR INFORMATION PLEASE |
| SEE THE STATE WEBSITE AT WWW.FLORIDABUILDING.ORG. |
| PRODUCTS WITH STATEWIDE APPROVAL ARE REQUIRED TO BE |
| SUBMITTED WITH A COVER SHEET THAT LISTS THE PRODUCT |
| IDENTITY NUMBER FROM THE STATE. IF THE PRODUCT DOES NOT |
| HAVE STATEWIDE APPROVAL, SUBMIT AN APPLICATION FOR |
| LOCAL PRODUCT APPROVAL OR SITE SPECIFIC FORM PER RULE |
| 9B-72. SEE ATTACHMENT. WW.FLORIDABUILDING.ORG |
| |
| 20) ) WPB ADMIN CODE 106.3* PRODUCT APPROVALS. THOSE |
| PRODUCT WHICH ARE REGULATED BY DCA RULE 9B-72 SHALL BE |
| REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF |
| RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. |
| |
| 21) THE MIAMI-DADE PRODUCT APPROVAL REPORTS THAT WERE |
| TESTED BEFORE 2004 FBC WILL NEED TO BE REVIEWED BY AN |
| ENGINEER TO SEE IF REDUCTIONS NEED TO BE TAKEN. 2004 |
| FBC 1605.3.1.1 DO NOT ALLOW FOR THE 1/3RD INCREASES |
| THAT HAD BEEN TAKEN WHEN THE PRODUCTS WERE TESTED .THE |
| PRODUCTS MAY REQUIRE ADDITIONAL FASTENERS. SEE |
| CALCULATIONS LISTED UNDER SUB HEADING# 3 ON THE PRODUCT |
| APPROVALS, IF THE 2004 CODE IS NOT REFERENCED AN |
| ENGINEER WILL NEED TO VERIFY LOADING OF FASTENERS!!!! |
| 1605.3.1.1 LOAD REDUCTION. |
| 1.IT IS PERMITTED TO MULTIPLY THE COMBINED EFFECT |
| OF TWO OR MORE VARIABLE LOADS BY 0.75 AND ADD THE |
| EFFECT OF DEAD LOAD. THE COMBINED LOAD USED IN DESIGN |
| SHALL NOT BE LESS THAN THE SUM OF THE EFFECT OF DEAD |
| LOAD AND ANY OF THE VARIABLE LOADS. |
| 2.INCREASES IN ALLOWABLE STRESS SPECIFIED IN THE |
| MATERIALS, SECTIONS OF THIS CODE OR A REFERENCED |
| STANDARD SHALL NOT BE PERMITTED TO BE USED WITH LOAD |
| COMBINATIONS OF SECTIONS 1605.3.1 . DURATION OF LOAD |
| INCREASE SHALL BE PERMITTED IN ACCORDANCE WITH CHAPTER |
| 23 . |
| |
| 22)PROVIDE STORM PANEL INFORMATION WITH INSTALLATION |
| SCHEDULE AND KEY PLAN WITH |
| SPECIFIC ANCHORS AND MOUNTING TO BE USED FOR ALL |
| NON-IMPACT GLAZING. FBC 1606.1.4. |
| |
| 23) FL BLD CODE 2001 SECTION 103.6, 1606.1.4, 1707.4 |
| & 3401.7.2.4. PROCEDURES: 1(B) A COMPLETE INSTALLATION |
| SCHEDULE SUMMARIZING & IDENTIFYING |
| OPENING SIZES, STORY HEIGHTS, UNIT MARK NUMBERS, UNIT |
| SPANS/WIDTHS, UNIT STORM BAR REINFORCING REQUIREMENTS, |
| WALL PRESSURE ZONES, SLAT TYPES, ETC., SHALL BE |
| SUBMITTED AT TIME OF PERMIT APPLICATION TO FACILITATE |
| PLAN REVIEW AND PERMIT ISSUANCE. |
| 104.6*/ 1609.1.4/ 1714.5 STANDARDS FOR WIND-BORNE |
| DEBRIS IMPACT PROTECTION |
| QUESTION# 13 RECOGNIZING SUCH CONCERNS AS ABSENTEE |
| OWNERS, OR CASES WHERE LONGER TIME & EFFORT IS |
| NECESSARY TO SECURE SHUTTERS ON LARGE OR MULTI-STORY |
| BUILDINGS, WHAT MEASURES ARE BEING RECOMMENDED OR |
| IMPLEMENTED TO ENSURE THAT COMPLETE INSTALLATION OR |
| SECURING IS DONE SUFFICIENTLY IN ADVANCE OF THE |
| HURRICANE? |
| |
| IN MATTERS CONCERNING PUBLIC SAFETY, HEALTH, AND THE |
| GENERAL WELFARE NOT SPECIFICALLY ADDRESSED IN THE CODE, |
| SECTION 104.6 OF THE FLORIDA BUILDING CODE,BUILDING, |
| CHAPTER 1, |
| ADMINISTRATIVE CODE2004 EDITION AS AMENDED BY THE CITY |
| OF WEST PALM BEACH, PROVDES THE ABILITY FOR THE |
| BUILDING OFFICIAL TO IMPLEMENT REQUIREMENTS FOR |
| ENSURING STABILITY, STRENGTH, AND THE PROPER OPERATION |
| OF EXISTING BUILDINGS. |
| |
| IN ORDER TO ASSURE THE SECURING OF SHUTTERS ON LARGE OR |
| MULTI-STORY BUILDINGS, OR MULTIPLE BUILDINGS ON THE |
| SAME PROPERTY, PRE-STORM PREPARATION PLANS MUST BE |
| SUBMITTED BY THE PROPERTY OWNERS OR MANAGING AGENTS FOR |
| REVIEW BY THE CONSTRUCTION SRVICES DEPARTMENT. ANY SUCH |
| PLAN SHALL INCLUDE, AT A MINIMUM, ON SITE LOCATION OF |
| THE SHUTTERS, PARTY RESPONSIBLE FOR SECURING THE |
| SHUTTERS ( SAID PARTY MUST BE LOCATED WITHIN PALM BEACH |
| COUNTY), TOTAL NUMBER OF OPENINGS TO BE PROTECTED AND |
| THE TOTAL TIME REQUIRED TO SECURE ALL OPENINGS. |
| PROTECTION OF OPENINGS SHALL BE ACCOMPLISHEDWITHIN |
| TWELVE (12) HOURS OR LESS OF THE |
| OFFICIAL NOTIFICATION BY THE NATIONAL WEATHER SERVICES |
| OF A HURRICANE WATCH. |
| |
| PROVISIONS IN THE BUILDING CODES (AND THIS STANDARD) |
| ARE NOT INTENDED TO PROHIBIT THE USE OF ALTERNATE |
| MATERIALS AND METHODS, AND THE BUILDING OFFICIAL TO |
| REVIEW AND APPROVE ANY ALTERNATE DEEMED EQUIVALENT IN |
| QUALITY, STRENGTH, EFFECTIVENESS, FIRE RESISTANCE, |
| DURABILITY AND SAFETY PRESCRIBED BY THIS CODE. BASED |
| UPON THIS CODE PROVISION, ACCEPTANCE OF ALTERNATE |
| MATERIALS AND METHODS MAY BE APPROVED ON A CASE-BY-CASE |
| BASIS AND SHALL REQUIRE SUFFICIENT EVIDENCE OR PROOF TO |
| SUBSTANTIATE ANY CLAIM MADE REGARDING THE ALTERNATE. |
| |
| 24)THIS ROOF IS MISSING OR NOT INCOMPLIANCE WITH |
| THE FOLLOW ITEMS: |
| _XXX__ CONTRACTOR / ENGINEER DID NOT INDICATE THE ROOF |
| PITCH. |
| |
| _XXX__ CONTRACTOR FAILED TO INDICATE WHICH SYSTEM TO BE |
| USED. |
| |
| _XXX__ THE SYSTEM PROVIDED HAS A LOWPRESSURE FOR |
| ZONE _2&3__ . |
| |
| |
| _XXX__ NOT KNOWN- THE SYSTEM PROVIDED STATES |
| LIMITATION# 7, SHOULD THE FASTENERRESISTANCE BE |
| LESS THAN THATREQUIRED, AS DETERMINED BY THE |
| BUILDING OFFICIAL, A REVISEDFASTENER SPACING, |
| PREPARED , SIGNEDAND SEALED BY A FLORIDA |
| REGISTEREDPROFESSIONAL ENGINEER, REGISTERED |
| ARCHITECT OR REGISTERED ROOF |
| CONSULTANT MAY BE SUBMITTED. |
| |
| __XXX_ NOT KNOWN- THE SYSTEM PROVIDED INDICATES |
| LIMITATION# 9, NO ENHANCED |
| FASTENING ALLOWED. |
| |
| 25) PLANS DO NOT SHOW ANY ROOF DRAINAGE, SLOPE OR |
| EMERGENCY OVERFLOWS: |
| |
| 1503.4.1 GUTTERS. |
| GUTTERS AND LEADERS PLACED ON THE OUTSIDE OF BUILDINGS, |
| OTHER THAN GROUP R-3 AS APPLICABLE IN SECTION 101.2 , |
| PRIVATE GARAGES AND BUILDINGS OF TYPE V CONSTRUCTION, |
| SHALL BE OF NONCOMBUSTIBLE MATERIAL OR A MINIMUM OF |
| SCHEDULE 40 PLASTIC PIPE. |
| |
| 1503.4.2 SCUPPER. |
| WHERE REQUIRED FOR ROOF DRAINAGE, A SCUPPER SHALL BE |
| PLACED LEVEL WITH THE ROOF SURFACE IN A WALL OR |
| PARAPET. THE SCUPPER SHALL BE LOCATED AS DETERMINED BY |
| THE SLOPE AND THE CONTRIBUTING AREA OF THE ROOF. THE |
| EXTERIOR FACING OR LINING OF A SCUPPER, IF METAL, SHALL |
| BE THE SAME AS FLASHING MATERIAL REQUIRED BY SECTIONS |
| 1503 THROUGH 1510 FOR THE PARTICULAR TYPE OF COVERING |
| SPECIFIED FOR THE BUILDING. FOR OTHER TYPE MATERIALS, |
| FOLLOW MANUFACTURER?S SPECIFICATIONS. |
| |
| 1503.4.3 OVERFLOW SCUPPERS. |
| WHEN OTHER MEANS OF DRAINAGE OF OVERFLOW WATER IS NOT |
| PROVIDED, OVERFLOW SCUPPERS SHALL BE PLACED IN WALLS OR |
| PARAPETS NOT LESS THAN 2 INCHES (51 MM) NOR MORE THAN 4 |
| INCHES (102 MM) ABOVE THE FINISHED ROOF COVERING AND |
| SHALL BE LOCATED AS CLOSE AS PRACTICAL TO REQUIRED |
| VERTICAL LEADERS OR DOWNSPOUTS OR WALL AND PARAPET |
| SCUPPERS. AN OVERFLOW SCUPPER SHALL BE SIZED IN |
| ACCORDANCE WITH THE FLORIDA BUILDING CODE, PLUMBING. |
| |
| 26) PLANS ALSO FAIL TO PROVIDE ENERGY CALCULATIONS. |
| |
| 27) IF THIS IS NOT A RESIDENCEON TARGET DESIGN CAN |
| NOT WORK AS DESIGNER OF RECORD, PLEASE SEE DEPARTMENT |
| OF BUSINESS & PROFESSIONAL REGULATION, DIVISION OF |
| ADMINISTRATION CASE HEARING 03-0489!!!! THIS MAY EFFECT |
| ENGINEER RIZA ALTANS LICENSURE ALSO!!! |
| |
| 28)BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, |
| IMPACT FEES MUST BE PAID TO PALM BEACH COUNTY. THE |
| ACTUAL PERMIT SET OF PLANS MUST BE STAMPED BY THAT |
| OFFICE, AND A COPY OF THE PAID RECEIPT ATTACHED TO THE |
| PERMIT APPLICATION PLEASE CALL (561)233-5025 FOR MORE |
| INFORMATION. |
| |
| BUILDING PLAN REVIEW II |
| JIM WITMER C. B. O. |
| |
| TEL: (561)805-6715 |
| FAX: (561)659-8026 |
| E-MAIL: [email protected] |