Plan Review Details - Permit 07050831
Plan Review Stops For Permit 07050831
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2007-08-21 Cont ID  
Sent By amorse Date 2007-08-21 Time 17:14 Rev Time 0.00
Received By amorse Date 2007-08-21 Time 17:14 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2007-08-15 Cont ID  
Sent By amorse Date 2007-08-15 Time 18:03 Rev Time 0.00
Received By amorse Date 2007-08-15 Time 18:03 Sent To PC
Notes
2007-08-15 18:13:45 
  
 DENIED
  
 TALKED WITH CONTRACTOR GAETON WITH GM CONST. ON 7/24/07
 AS HE REALLY NEEDED PERMIT ISSUED. I TOLD HIM THAT THE
 ENERGY CALC'S WERE THE ONLY THING HOLDING UP THE PERMIT
 AND ASKED THAT HE SUBMIT 2 COPIES AND HAVE THEM ROUTED
 TO MY DESK AS A NO CHARGE SUBMITTAL AND I COULD PROCESS
 THE REVIEW WITHIN A COUPLE OF DAYS. NO FURTHER CONTACT
 WAS MADE AND NO ENERGY CALC'S WERE SUBMITTED.
  
 8/15/07 THE PERMIT APPLICATION HAS BEEN DENIED AND
 FILED UNDER "G" FOR PICK UP
  
 BLDG PLAN REVIEW
 ADRIAN MORSE
 561-805-6716

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-07-01 Cont ID  
Sent By amorse Date 2007-07-01 Time 14:21 Rev Time 0.00
Received By amorse Date 2007-07-01 Time 14:21 Sent To  
Notes
2007-07-01 14:24:02 
  
 DENIED
  
 1)A DESIGN PROFESSIONAL OR AN OWNER MUST ELECT ONE OR
 A COMBINATION OF LEVELS OF ALTERATION PURSUANT TO
 SECTIONS 303 , 304 AND 305 OF THE FBC EXISTING.
  
 2)THE CLAIMED VALUATION ON THE PERMIT APPLICATION IS
 LOW. FOR PERMITTING PURPOSES, VALUATION OF BUILDINGS
 AND SYSTEMS SHALL BE THE TOTAL REPLACEMENT COST
 EXCLUDING LAND VALUE. OUR VALUATION REFERENCE IS ICC
 (BVD), MARSHALL-SWIFT AND MEANS COST ANALYSIS SERVICES
 PER 108.3 FBC* THE AMOUNT DUE FOR THE INCREASED VALUE
 IS $264.22
  
 3)PROVIDE BATHROOM DOOR THAT MEETS THE ACCESSIBILITY
 REQUIREMENTS MUST BE 29" CLEAR WITH DOOR OPEN AT 90
 DEGREES1
 4)PROVIDE SMOKE ALARMS PER R313.1.1 FBC RES.
  
 5)THE CITY OF WEST PALM BEACH REQUIRES THE FLORIDA
 STATE PRODUCT APPROVAL COVER SHEETS WHEN AVAILABLE.
 THEY CAN BE SEARCHED FOR ON WWW.FLORIDABUILDING.ORG.
 WHEN AVAILABLE AND NOT SUBMITTED APPLICATIONS WILL BE
 DENIED
  
 6)PROVIDE IMPACT PROTECTION FOR OPENINGS PER 507.3
 FBC EXISTING. THIS WILL REQUIRE PRODUCT APPROVALS TO BE
 SUBMITTED
  
 7)PROVIDE WIND DESIGN DATA ON DRAWINGS PER 1603.1.4
 FBC AND STATE ALL WINDOW AND DOOR OPENING DESIGN
 PRESSURES
  
 8)A DESIGN PROFESSIONAL THAT IS REGISTERED TO
 PRACTICE UNDER CHAPTER 481 OR 471 OF THE FLORIDA
 STATUTES SHALL AFFIX THEIR LICENSE NUMBER, OFFICIAL
 SEAL, SIGNATURE AND DATE TO SAID DRAWINGS AND
 SPECIFICATIONS (LICENSE NUMBER IS NOT PRESENT ON
 PLANS)
  
 9)ENERGY CALC'S ARE REQUIRED WHEN THE VALUE OF
 RENOVATIONS EXCEDES 30% OF THE BUILDING VALUE PER
 13-101.2.3 FBC
  
 10)PLEASE HAVE OWNER INFORMATION MATCH ON PERMIT,
 DRAWINGS, AND NOC
  
 11)A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT IS REQUIRED PRIOR TO A PERMIT BEING
 ISSUED
  
 BLDG PLAN REVIEW
 ADRIAN MORSE
 561-805-6716
  
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2007-07-20 Cont ID  
Sent By btrobaug Date 2007-07-20 Time 07:00 Rev Time 0.00
Received By btrobaug Date 2007-07-20 Time 06:36 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2007-06-18 Cont ID  
Sent By btrobaug Date 2007-06-18 Time 11:12 Rev Time 0.00
Received By btrobaug Date 2007-06-18 Time 10:56 Sent To Z
Notes
2007-06-18 11:12:54 
  
  
 NONCOMPLIANT
  
 PLEASE MAKE THE FOLLOWING CORRECTIONS FOR CODE
 COMPLIANCE AND RESUBMIT FOR REVIEW
  
 1} KITCHEN RECEPTACLE SPACING MUST COMPLY WITH
 210.52(A), 210.52(C), AND 210.8(A)(6) GFI. THERE IS
 ONLY ONE SMALL APPLIANCE CIRCUIT LISTED ON THE PANEL
 SCHEDULE.
  
 2} THERE IS A RECEPTACLE SHOWM AT THE WATER HEATER. A
 DISCONNECT IS REQUIRED PER 422.16(A).
  
 3} SMOKE ALARMS MUST BE INSTALLED TO COMPLY WITH R313.1
 RESIDENTIAL FLORIDA BUILDING CODE.SEE HEAT DETECTOR FOR
 KITCHEN.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-07-17 Cont ID  
Sent By adarroug Date 2007-07-17 Time 13:24 Rev Time 0.00
Received By adarroug Date 2007-07-17 Time 13:24 Sent To E
Notes
2007-07-17 13:24:46TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2007-07-01 Time   Rev Time 0.00
Received By adarroug Date 2007-06-07 Time 11:14 Sent To  
Notes
2007-06-07 11:16:03TO "E" BOX

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2007-06-19 Cont ID  
Sent By tgordon Date 2007-06-19 Time 10:41 Rev Time 0.15
Received By tgordon Date 2007-06-19 Time 10:41 Sent To P
Notes
2007-06-19 10:42:30NO MECHANICAL PLANS SUBMITTED, AND NO
 MECHANICAL PERMIT NUMBER APPLIED FOR AT
 THIS TIME.

Review Stop P PLUMBING
Rev No 1 Status N Date 2007-06-27 Cont ID  
Sent By mperson Date 2007-06-27 Time 08:26 Rev Time 0.15
Received By mperson Date 2007-06-27 Time 08:26 Sent To B
Notes
2007-06-27 08:29:27NOTE: SHEET A-1 WORK DESCRIPTION #12, STATES ALL
 EXISTING PLUMBING TO REMAIN.

Review Stop Z ZONING
Rev No 1 Status N Date 2007-06-19 Cont ID  
Sent By choops Date 2007-06-19 Time 08:08 Rev Time 0.00
Received By choops Date 2007-06-19 Time 08:08 Sent To M
Notes
***NONE***