Plan Review Details - Permit 07050714
Plan Review Stops For Permit 07050714 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
N |
Date |
2007-08-01 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-08-01 |
Time |
17:27 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-08-01 |
Time |
17:27 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2007-07-11 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-07-11 |
Time |
15:40 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-07-11 |
Time |
15:40 |
Sent To |
|
|
Notes |
2007-07-11 15:49:06 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBC FLORIDA BUILDING CODE 2004 | | FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL FBC* CITY | | OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | | FROM PREVIOUS LIST: | | | | 2.)OPENINGS 8 THROUGH 17, INSTALLATION SCHEDULE | | SPECIFIES CBS, A FOR BOTTOM MOUNTING TYPE."A" IS | | POURED CONCRETE, WALL HEADER ONLY.OTHER OPENINGS | | (18-19) SPECIFY TYPE "L", WHICH IS FOR POURED CONCRETE. | | PLEASE ADDRESS.CHECK ALL OPENINGS. | | | | 2ND REVIEW, OPENINGS 18-19 STILL STATE THIS IS CBS, | | CONNECTION TYPE L.REVISE AND CHECK ALL OPENINGS. | | | | NEW COMMENT: | | | | ALL DOCUMENTS PREPARED BY AN ENGINEER AND SUBMITTED FOR | | PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED ORIGINALS | | FAC61G15-23.002 (WIND LOAD CHART).ENGINEERING IS NOT | | REQUIRED BUT IF YOU SUBMIT ENGINEERING, TWO SIGNED, | | SEALED, DATED ORIGINALS ARE REQUIRED. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2007-06-13 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-06-13 |
Time |
15:55 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-06-13 |
Time |
15:55 |
Sent To |
|
|
Notes |
2007-06-13 16:01:39 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBC FLORIDA BUILDING CODE 2004 | | FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | | 1.)ENGINEER IS TO SPECIFY ANCHORING OF TRACK INTO THE | | SPAN TUBE.THE INSTALLATION SCHEDULE STATES "NA", BUT | | THIS INFORMATION IS RQUIRED.PRODUCT APPROVAL DOES NOT | | ADDRESS ANCHORING INTO A METAL SUBSTRATE. | | | | 2.)OPENINGS 8 THROUGH 17, INSTALLATION SCHEDULE | | SPECIFIES CBS, A FOR BOTTOM MOUNTING TYPE."A" IS | | POURED CONCRETE, WALL HEADER ONLY.OTHER OPENINGS | | (18-19) SPECIFY TYPE "L", WHICH IS FOR POURED CONCRETE. | | PLEASE ADDRESS.CHECK ALL OPENINGS. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2007-07-23 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-07-23 |
Time |
16:48 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-07-23 |
Time |
16:48 |
Sent To |
B |
|
Notes |
2007-07-23 16:48:39 | TO "SHILL" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2007-07-03 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-07-03 |
Time |
16:16 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-07-03 |
Time |
16:16 |
Sent To |
B |
|
Notes |
2007-07-03 16:16:21 | TO "SHILL" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2007-06-13 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-06-13 |
Time |
16:01 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-05-18 |
Time |
14:23 |
Sent To |
|
|
Notes |
2007-05-18 14:23:25 | TO "MISC" BOX#1 |
|
|
|
Account Summary | Usage Policy | Privacy Policy