Plan Review Details - Permit 07050513
Plan Review Stops For Permit 07050513
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2007-12-05 Cont ID  
Sent By shill Date 2007-12-05 Time 14:41 Rev Time 0.00
Received By shill Date 2007-12-05 Time 14:41 Sent To  
Notes
2007-12-05 14:41:29***PROVISO***SUMBIT DOOR & WINDOW PRODUCT APPROVALS

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2007-11-13 Cont ID  
Sent By shill Date 2007-11-13 Time 15:39 Rev Time 0.00
Received By shill Date 2007-11-13 Time 15:39 Sent To  
Notes
2007-11-13 15:41:15****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC*
 CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 FAC
 FLORIDA ADMINISTRATIVE CODE
 FSFLORIDA STATUTE
  
 COMMENTS FROM PREVIOUS LIST:
  
 1.)THIS JOB DOES NOT FALL UNDER ANY OF THE EXCEPTIONS
 TO ARCHITECTURE, FS481.229.THEREFORE, ALL PLANS
 REQUIRED TO SHOW CODE COMPLIANCE ARE REQUIRED TO BE
 PREPARED BY A DESIGN PROFESSIONAL.
  
 2ND REVIEW; SITE PLAN NOT SEALED.
  
 3RD REVIEW, SOMEONE WROTE A NOTE STATING "DEFINE SITE
 PLAN".THE SITE PLAN IS THE PHOTOCOPY OF A1.1.1,
 LABELED "ARCHITECTURAL SITE PLAN - FIRST FLOOR
 (GARAGE)".DOCUMENTS PREPARED BY AN ARCHITECT AND
 SUBMITTED FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED,
 DATED ORIGINALS.A SITE PLAN IS A PLAN SHOWING SITE
 CONDITIONS AND PROPOSED LOCATION OF IMPROVEMENT.ALSO
 SEE ITEM 7.
  
 2-3.)ADDRESSED.
  
 4.)3RD REVIEW REGARDING WIND PRESSURE DESIGN - SEE
 ATTACHED EMAIL FROM ROBERT BROWN, CBO.
  
 5.)ADDRESSED.
  
 6.)SEE FBC603 REGARDING COMBUSTIBLES.SEE ALSO NOTES
 5 AND 6 ON SHEET 3 OF 3, ELITE PANELS, LIMITATIONS &
 CONDITIONS OF USE.CODE REQUIREMENTS AND COMPLIANCE
 ARE TO BE INCORPORATED INTO THE PLAN.IT IS NOT SURE
 HOW THIS COMMENT HAS BEEN ADDRESSED.
  
 7.)DOCUMENTS PREPARED BY AN ARCHITECT AND SUBMITTED
 FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED
 ORIGINALS (SITE PLAN).
  
 8-9.)ADDRESSED.
  
 10.)REGARDING COMPONENTS AND CLADDING, SEE ATTACHED
 EMAIL FROM ROBERT BROWN, CBO.
  
 11.-12.)ADDRESSED.
  
 13.)FLORIDA STATE OR LOCAL PRODUCT APPROVAL REQUIRED
 FOR THE ELITE PANEL, FAC9B72.APPLICATION IS PENDING.
 PLEASE APPLY FOR LOCAL PRODUCT APPROVAL OR CHECK
 WEBSITE ; APPLICATION IS ATTACHED.
  
 3RD REVIEW - NOT ADDRESSED.PLEASE PROVIDE A CURRENT
 PRODUCT APPROVAL.
  
 14.)REGARDING THE SLIDING DOOR REMOVED FROM THE PLAN,
 PLEASE REMOVE SLIDING DOOR PRODUCT APPROVAL AND SUBMIT
 SWING DOOR PRODUCT APPROVAL (APPROVED BY DOR).
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2007-06-26 Cont ID  
Sent By shill Date 2007-06-26 Time 15:48 Rev Time 0.00
Received By shill Date 2007-06-26 Time 15:48 Sent To  
Notes
2007-06-26 16:04:27****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC*
 CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 FAC
 FLORIDA ADMINISTRATIVE CODE
 FSFLORIDA STATUTE
  
 COMMENTS FROM PREVIOUS LIST:
  
 1.)THIS JOB DOES NOT FALL UNDER ANY OF THE EXCEPTIONS
 TO ARCHITECTURE, FS481.229.THEREFORE, ALL PLANS
 REQUIRED TO SHOW CODE COMPLIANCE ARE REQUIRED TO BE
 PREPARED BY A DESIGN PROFESSIONAL.
  
 2ND REVIEW; SITE PLAN NOT SEALED.
  
 2-3.)ADDRESSED.
  
 4.)THE ENGINEERING STATES THAT THIS IS A SINGLE
 FAMILY HOME, BUILDING HEIGHT LESS THAN 60', OPEN
 STRUCTURE, IMPORTANCE FACTOR OF .77.PLEASE REVISE
 THESE NOTES TO BE SPECIFIC TO THIS JOB, WHICH IS A HIGH
 RISE.
  
 2ND REVIEW - HEIGHT AND IMPORTANCE FACTOR WERE NOT
 REVISED AND PRESSURES APPEAR VERY LOW.THIS BUILDING
 IS A HIGH RISE, AND AS SUCH THE GUARD SHACK IS SUBJECT
 TO THE SAME PRESSURES AS THE BUILDING.NOTE THAT WIND
 TUNNEL TEST REPORT MAY BE AVAILABLE.
  
 5.)INCLUDE A CODE SUMMARY; BUILDING TYPE FBC6
 (INCLUDE A OR B), BUILDING HEIGHT, SPRINKLER
 INFORMATION, OCCUPANCY CLASSIFICATION FBC 3.
  
 2ND REVIEW - THIS REFERS TO THE BUILDING.PROVIDE
 BUILDING HEIGHT AS PRESSURE INFORMATION IS AFFECTED.
  
 6.)SEE FBC603 REGARDING COMBUSTIBLES.SEE ALSO NOTES
 5 AND 6 ON SHEET 3 OF 3, ELITE PANELS, LIMITATIONS &
 CONDITIONS OF USE.CODE REQUIREMENTS AND COMPLIANCE
 ARE TO BE INCORPORATED INTO THE PLAN.
  
 2ND REVIEW - THE RESPONSE STATES "OK".HOW IS THIS
 ADDRESSED ON THE PLAN?
  
 7.)DOCUMENTS PREPARED BY AN ARCHITECT AND SUBMITTED
 FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED
 ORIGINALS (SITE PLAN).
  
 8.)ADDRESSED.
  
 9.)IF THIS IS A FULLY SPRINKLERED BUILDING, FIRE
 SPRINKLERS WILL BE REQUIRED IN THIS NEW ROOM.FIRE
 SPRINKLER PLANS ARE REQUIRED,FBC*106.3.5.1.1(5),
 FS553.79 (2).
  
 2ND REVIEW - IF THIS BUILDING WITHIN A FULLY
 SPRINKLERED BUILIDING HAS A ROOF, FIRE SPRINKLER PLANS
 (WITH THE NEW SPACE SPRINKLERED) REQUIRED.
  
 10.)PROVIDE COMPONENT AND CLADDING DESIGN
 INFORMATION, FBC1603.1.4.
  
 2ND REVIEW - SEE OTHER COMMENTS; APPEARS LOW.
 CLARIFY.
  
 11.) PRODUCT APPROVALS ARE TO BE APPROVED BY DESIGNER
 OF RECORD, FBC*106.3.3.
  
 12.)THE PLAN STATES THAT THE GLASS IS TO BE IMPACT,
 BUT NON IMPACT PRODUCT APPROVALS WERE SUBMITTED. PLEASE
 ADDRESS.ALSO SEE ATTACHED POLICY, ITEM 13, REGARDING
 USE OF REMOVABLE SHUTTERS ON COMMERCIAL BUILDINGS.
  
 2ND REVIEW - STATES THAT NONHABITABLE SPACE DOES NOT
 REQUIRED IMPACT PROTECTION.PLEASE REMOVE STATEMENT AS
 THIS IS NOT A STANDALONE STRUCTURE UNDER ANY
 EXCEPTIONS.IMPACT PROTECTOIN IS REQUIRED.
  
 13.)FLORIDA STATE OR LOCAL PRODUCT APPROVAL REQUIRED
 FOR THE ELITE PANEL, FAC9B72.THE PAPERWORK SUBMITTED
 DOES NOT INCLUDE THE FLORIDA STATE PRODUCT APPROVAL.
  
 2ND REVIEW - APPLICATION IS PENDING.PLEASE APPLY FOR
 LOCAL PRODUCT APPROVAL; APPLICATION IS ATTACHED.
  
 14.)A SIDE HINGE DOOR IS REQUIRED, FBC1001.1,
 FBC1008.1.2 UNLESS THE SLIDING DOOR COMPLIES WITH
 FBC1008.1.3.3.
  
 15.)THIS WORK (DOOR AND WINDOW INSTALLATION) DOES NOT
 FALL UNDER THE SCOPE OF WORK OF AN ALUMINUM SPECIALTIES
 CONTRACTOR.NOTE THAT THIS IS A U LICENSE AND THE PALM
 BEACH COUNTY WEBSITE IS UNAVAILABLE, SO I CANNOT
 CONFIRM LICENSING AT THIS TIME.
  
 2ND REVIEW - PLEASE COMPLETE ANOTHER PERMIT APPLICATION
 AS A PORTION OF THE WORK IS TO BE PERMITTED WITH THE
 ALUMINUM SPECIALTIES LICENSE AND A PORTION IS TO BE
 PERMITTED WITH THE GLAZING LICENSE.TWO DIFFERENT
 PERMIT NUMBERS WILL BE ISSUED.
  
 16.)THE SITE PLAN IS TO BE PROVIDED IN A LEGIBLE
 FORMAT, TO SCALE, FBC106.SHOW THE PROPOSED
 IMPROVEMENT, TO SCALE, ON THE SITE PLAN.EXITING
 INFORMATION, FBC10, SHOULD BE CLEAR ON THE SITE PLAN.
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-06-04 Cont ID  
Sent By shill Date 2007-06-04 Time 10:00 Rev Time 0.00
Received By shill Date 2007-06-04 Time 10:00 Sent To E
Notes
2007-06-04 10:45:35****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC*
 CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 FAC
 FLORIDA ADMINISTRATIVE CODE
 FSFLORIDA STATUTE
  
 1.)THIS JOB DOES NOT FALL UNDER ANY OF THE EXCEPTIONS
 TO ARCHITECTURE, FS481.229.THEREFORE, ALL PLANS
 REQUIRED TO SHOW CODE COMPLIANCE ARE REQUIRED TO BE
 PREPARED BY A DESIGN PROFESSIONAL.
  
 2.)THE ENGINEERING TITLE FOR THIS JOB IS "SUN ROOM
 FOR :ONE WATERMARK PL".PLEASE REVISE TO BE
 CONSISTENT WITH THE SCOPE OF WORK.
  
 3.)THE ENGINEERING STATES THAT THIS IS EXPOSURE B.
 SEE FBC 1609.6.2.1(2), DEFINITION OF EXPOSURE C AND
 REVISE.
  
 4.)THE ENGINEERING STATES THAT THIS IS A SINGLE
 FAMILY HOME, BUILDING HEIGHT LESS THAN 60', OPEN
 STRUCTURE, IMPORTANCE FACTOR OF .77.PLEASE REVISE
 THESE NOTES TO BE SPECIFIC TO THIS JOB, WHICH IS A HIGH
 RISE.
  
 5.)INCLUDE A CODE SUMMARY; BUILDING TYPE FBC6
 (INCLUDE A OR B), BUILDING HEIGHT, SPRINKLER
 INFORMATION, OCCUPANCY CLASSIFICATION FBC 3.
  
 6.)SEE FBC603 REGARDING COMBUSTIBLES.SEE ALSO NOTES
 5 AND 6 ON SHEET 3 OF 3, ELITE PANELS, LIMITATIONS &
 CONDITIONS OF USE.CODE REQUIREMENTS AND COMPLIANCE
 ARE TO BE INCORPORATED INTO THE PLAN.
  
 7.)DOCUMENTS PREPARED BY AN ARCHITECT AND SUBMITTED
 FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED
 ORIGINALS (SITE PLAN).
  
 8.)THE ENGINEERING STATES THAT THIS DESIGN IS FOR A
 4" SLAB, AND ALSO HAS A DISCLAIMER STATEMENT THAT
 DESIGN IS BASED ON INFORMATION PROVIDED BY CLIENT. THIS
 IS A HIGHRISE, THRESHOLD BUILDING.THE ENGINEER IS TO
 CONFIRM STRUCTURAL INFORMATION (PLANS ARE AVAILABLE FOR
 THIS BUILDING) FOR DESIGN.PLEASE DO SO AND REMOVE THE
 STATEMENT FROM THE PLAN.
  
 9.)IF THIS IS A FULLY SPRINKLERED BUILDING, FIRE
 SPRINKLERS WILL BE REQUIRED IN THIS NEW ROOM.FIRE
 SPRINKLER PLANS ARE REQUIRED,FBC*106.3.5.1.1(5),
 FS553.79 (2).
  
 10.)PROVIDE COMPONENT AND CLADDING DESIGN
 INFORMATION, FBC1603.1.4.
  
 11.) PRODUCT APPROVALS ARE TO BE APPROVED BY DESIGNER
 OF RECORD, FBC*106.3.3.
  
 12.)THE PLAN STATES THAT THE GLASS IS TO BE IMPACT,
 BUT NON IMPACT PRODUCT APPROVALS WERE SUBMITTED. PLEASE
 ADDRESS.ALSO SEE ATTACHED POLICY, ITEM 13, REGARDING
 USE OF REMOVABLE SHUTTERS ON COMMERCIAL BUILDINGS.
  
 13.)FLORIDA STATE OR LOCAL PRODUCT APPROVAL REQUIRED
 FOR THE ELITE PANEL, FAC9B72.THE PAPERWORK SUBMITTED
 DOES NOT INCLUDE THE FLORIDA STATE PRODUCT APPROVAL.
  
 14.)A SIDE HINGE DOOR IS REQUIRED, FBC1001.1,
 FBC1008.1.2 UNLESS THE SLIDING DOOR COMPLIES WITH
 FBC1008.1.3.3.
  
 15.)THIS WORK (DOOR AND WINDOW INSTALLATION) DOES NOT
 FALL UNDER THE SCOPE OF WORK OF AN ALUMINUM SPECIALTIES
 CONTRACTOR.NOTE THAT THIS IS A U LICENSE AND THE PALM
 BEACH COUNTY WEBSITE IS UNAVAILABLE, SO I CANNOT
 CONFIRM LICENSING AT THIS TIME.
  
 16.)THE SITE PLAN IS TO BE PROVIDED IN A LEGIBLE
 FORMAT, TO SCALE, FBC106.SHOW THE PROPOSED
 IMPROVEMENT, TO SCALE, ON THE SITE PLAN.EXITING
 INFORMATION, FBC10, SHOULD BE CLEAR ON THE SITE PLAN.
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2007-06-25 Cont ID  
Sent By btrobaug Date 2007-06-25 Time 13:40 Rev Time 0.00
Received By btrobaug Date 2007-06-25 Time 11:58 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2007-06-04 Cont ID  
Sent By btrobaug Date 2007-06-04 Time 11:41 Rev Time 0.33
Received By btrobaug Date 2007-06-04 Time 11:29 Sent To PC
Notes
2007-06-04 11:40:57 
  
 NONCOMPLIANT
  
 PLEASE MAKE THE FOLLOWING CORRECTIONS FOR CODE
 COMPLIANCE AND RESUBMIT FOR REVIEW.
  
 1} THE PERSON TAKING RESPONSIBILITY FOR THE DESIGN MUST
 PRINT AND SIGN THEIR NAME TO SAME PER 106.3.4.3. FBC.
  
 2} PLEASE NOTE AN ELECTRICAL PERMIT IS REQUIRED FOR THE
 SCOPE OF WORK PURPOSED. 105.1 FBC AS AMENDED.
  
 3} INDICATE HOW THE STRUCTURE IS BEING FED.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2007-11-30 Cont ID  
Sent By adarroug Date 2007-11-30 Time 14:57 Rev Time 0.00
Received By adarroug Date 2007-11-30 Time 14:57 Sent To B
Notes
2007-11-30 14:57:31TO "SHILL" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2007-09-20 Cont ID  
Sent By adarroug Date 2007-09-20 Time 10:51 Rev Time 0.00
Received By adarroug Date 2007-09-20 Time 10:51 Sent To B
Notes
2007-09-20 10:52:09TO "SHILL" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-06-20 Cont ID  
Sent By adarroug Date 2007-06-20 Time 14:55 Rev Time 0.00
Received By adarroug Date 2007-06-20 Time 14:55 Sent To E
Notes
2007-06-20 14:55:48TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-06-04 Cont ID  
Sent By shill Date 2007-06-04 Time 10:45 Rev Time 0.00
Received By shill Date 2007-05-16 Time 14:58 Sent To  
Notes
2007-05-16 14:58:31TO "MISC" BOX#1