Plan Review Stops For Permit 07050402 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2007-10-21 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-10-21 |
Time |
14:27 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-10-21 |
Time |
14:27 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2007-06-13 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-06-13 |
Time |
15:38 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-06-13 |
Time |
15:38 |
Sent To |
|
|
Notes |
2007-06-13 15:38:49 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBC FLORIDA BUILDING CODE 2004 | | FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | | 1.)SPECIFY ANCHOR, DIAMETER AND LENGTH.FBC R 301 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2007-10-12 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2007-10-12 |
Time |
16:09 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2007-10-12 |
Time |
16:09 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2007-05-21 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2007-05-21 |
Time |
11:54 |
Rev Time |
0.33 |
Received By |
btrobaug |
Date |
2007-05-21 |
Time |
10:55 |
Sent To |
G |
|
Notes |
2007-05-21 11:54:40 | | | NONCOMPLIANT | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS FOR CODE | | COMPLIANCE AND RESUBMIT FOR REVIEW | | | | 1} PROVIDE A RISER DIAGRAM SHOWING ELECTRICAL | | CONNECTION OF ALL SERVICE AND GENERATOR EQUIPMENT | | | | 2} PLEASE LOCATE ALL SERVICE EQUIPMENT ON THE PLAN, | | METER ENCLOSURE, DISCONNECTS AND PANELS, SO THAT | | COMPLIANCE WITH ARTICLES 225 AND 230 CAN BE REVIEWED. | | DO THIS ON A SITE PLAN, NOT ON THE SURVEY, 106.1.3FBC. | | | | 3} 702.5 CAPACITY AND RATING. AN OPTIONAL STANDBY | | SYSTEM SHALL HAVE ADEQUATE CAPACITY AND RATING FOR THE | | SUPPLY OF ALL EQUIPMENT INTENDED TO BE OPERATED AT ONE | | TIME.PROVIDE A LOAD CALCULATION SHOWING COMPLIANCE | | WITH THIS ARTICLE. | | | | 4} THE PERSON TAKING RESPONSIBILITY FOR THE | | PLAN/DRAWINGS, SHALL PRINT AND SIGN THEIR NAME ON THE | | SHEETS THEY DRAW. PLEASE DO THIS PRIOR TO | | RESUBMITTING. | | | | THE VALUE ON THE APPLICATION MUST INCLUDE THE TOTAL | | COST OF LABOR AND MATERIAL. VALUATION REFERENCES MAY | | INCLUDE THE LATEST PUBLISHED DATA OF NATIONAL | | CONSTRUCTION COST ANALYSIS SERVICES PER 108.3 FBC AS | | AMENDED. | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | BILL TROBAUGH | | ELECTRICAL PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561/805-6718 | | [email protected] |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
P |
Date |
2007-10-19 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2007-10-19 |
Time |
11:15 |
Rev Time |
0.00 |
Received By |
mperson |
Date |
2007-10-19 |
Time |
11:15 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
F |
Date |
2007-05-24 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2007-05-24 |
Time |
16:34 |
Rev Time |
0.45 |
Received By |
mperson |
Date |
2007-05-24 |
Time |
16:34 |
Sent To |
B |
|
Notes |
2007-05-24 16:57:28 | DENIED | | REFERENCE: | | ** FBC-2004 FUEL GAS. | | ** THE CITY OF WEST PALM BEACH GAS PERMIT APPLICATION | | REQUIREMENTS. | | ** FBC-2004 CHAPTER 1, THE CITY OF | | WEST PALM BEACH AMENDMENTS. | | ** FLORIDA ADMINISTRATIVE CODE. | | ** FLORIDA STATUTES. | | | | THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR | | GAS PLAN REVIEW TO MEET CODE COMPLIANCE: | | | | 1. PLEASE REFERENCE ZONING COMMENT AND CORRECT.A GAS | | PERMIT CAN NOT BE ISSUED UNTIL | | A GEN/RES PERMIT APPLICATION HAS BEEN | | APPLIED FOR AND APPROVED BY ZONING FOR | | THE GENERATOR LOCATION. | | | | 2. PLEASE CLEARLY INDICATE THE ABOVE GROUND PIPING | | MATERIAL AND CORRESPONDING LENGTHS OF CUT SECTIONS ON | | THE RESUBMITTED GAS ISOMETRIC OFTHE PROPOSED | | GENERATOR PER FBC-2004 FUEL GAS. | | | | 3. PLEASE CLEARLY INDICATE THE SHUT OFF VALVE AND MP | | REGULATOR FOR THE PROPOSED GENERATOR ON THE RESUBMITTED | | GAS ISOMETRIC PER FBC-2004 FUEL GAS, SECTION 409.4 MP | | REGULATOR VALVES: A LISTED SHUTOFF VALVE SHALL BE | | INSTALLED IMMEDIATELY AHEAD OF EACH MP REGULATOR. | | | | 4. PLEASE CLEARLY INDICATE THE GAS TYPE (LP OR | | NATURAL) ON THE RESUBMITTED GAS ISOMETRIC. | | | | 5. PLEASE SUBMIT MANUFACTURER SPECIFICATION OF THE | | PROPOSED GENERATOR TO VERIFY GAS TYPE AND BTU LOAD AND | | INSTALLATION INSTRUCTIONS TO VERIFY SETBACKS TO | | ADJACENT STRUCTURES. | | | | 6. PLEASE SUBMIT MANUFACTURER'S SPECIFICATIONS OF THE | | PROPOSED 2 PSI TO 0.5 PSI MP REGULATOR INDICATING THE | | MANUFACTURER'S NAME, MODEL NUMBER, MAXIMUM LOAD | | CAPACITY AND SHOW A LISTING FROM A NATIONALLY | | RECOGNIZED TESTING LABORATORY (NRTL). | | | | 7. FBC-2004 CHAPTER 1,SECTION 106.3.4.2: | | THE PERSON RESPONSIBLE FOR THE DESIGN OF | | THE DRAWING (GAS ISOMETRIC) SHALL CLEARLY PRINT AND | | SIGN | | NAME, AND ALSO DATE DRAWING. PLEASE DO | | THIS PRIOR TO RESUBMITTING. | | | | END OF COMMENTS: | | | | REVIEW BY MIKE PERSON | | (561) 805-6730 | | FAX (561) 805-6731 | | E-MAIL [email protected] | | UNDER SUPERVISION OF K.STEVENS | | (561) 805-6721 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2007-10-10 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-10-10 |
Time |
10:05 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-10-10 |
Time |
10:05 |
Sent To |
Z |
|
Notes |
2007-10-10 10:05:45 | TO "Z" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2007-05-18 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-05-18 |
Time |
13:17 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-05-18 |
Time |
13:17 |
Sent To |
E |
|
Notes |
2007-05-18 13:17:49 | TO "GEN-RES" "E" |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2007-10-21 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-10-21 |
Time |
14:27 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-05-14 |
Time |
14:40 |
Sent To |
|
|
Notes |
2007-05-14 14:40:43 | TO "Z" BOX |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2007-10-19 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2007-10-19 |
Time |
12:05 |
Rev Time |
0.20 |
Received By |
tgordon |
Date |
2007-10-19 |
Time |
12:05 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2007-05-18 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2007-05-18 |
Time |
14:21 |
Rev Time |
0.15 |
Received By |
tgordon |
Date |
2007-05-18 |
Time |
14:21 |
Sent To |
E |
|
Notes |
2007-05-18 14:22:30 | *** DENIED *** | | 1) SEE ZONING REVIEV NOTE, PLEASE CORRECT. | | | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2007-10-12 |
|
|
Cont ID |
|
Sent By |
choops |
Date |
2007-10-12 |
Time |
15:45 |
Rev Time |
0.00 |
Received By |
choops |
Date |
2007-10-12 |
Time |
15:45 |
Sent To |
E |
|
Notes |
2007-10-12 15:46:05 | ***APPROVED - RESUB #1*** | | | | SENT TO "E" - BT |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2007-05-15 |
|
|
Cont ID |
|
Sent By |
choops |
Date |
2007-05-15 |
Time |
16:03 |
Rev Time |
0.00 |
Received By |
choops |
Date |
2007-05-15 |
Time |
16:03 |
Sent To |
I |
|
Notes |
2007-05-15 16:04:21 | ***FAILED*** | | | | | | 1)PLEASE PROVIDE 2 COPIES OF ACTUAL SURVEYS | | INDICATING SCOPE OF WORK, DIMENSIONS OF SETBACKS TO | | PROPERTY LINES FROM GENERATOR. | | | | | | CHRIS HOOPS | | ZONING TECHNICIAN | | 561-805-6720 |
|
|