Plan Review Details - Permit 07050252
Plan Review Stops For Permit 07050252
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2007-06-13 Cont ID  
Sent By shill Date 2007-06-13 Time 09:58 Rev Time 0.00
Received By shill Date 2007-06-13 Time 09:58 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-05-29 Cont ID  
Sent By shill Date 2007-05-29 Time 11:19 Rev Time 0.00
Received By shill Date 2007-05-29 Time 11:19 Sent To  
Notes
2007-05-29 11:22:28****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC*
 CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 FAC
 FLORIDA ADMINISTRATIVE CODE
 FSFLORIDA STATUTE
  
 1.)THE SHUTTER SPAN FOR ALL OPENINGS IS 11'11 WHICH
 CONFLICTS WITH THE OPENING SIZES.THE ANCHORING
 SPECIFIED APPEARS COMPLIANT FOR OPENING SIZES SPANS,
 BUT NOT FOR THE SPAN WHICH YOU SPECIFY.SPAN FOR
 ACCORDIONS SHOULD BE THE BLADE LENGTH, SPAN FOR PANELS
 SHOULD BE ANCHOR TO ANCHOR.PLEASE REVISE.
  
 2.)REVISE EXPOSURE CATEGORY FBC1609.6.2.1(2), FBC
 R301.2.1.4.NOTE THAT THE DEFINITION FOR EXPOSURE C
 HAS CHANGED EFFECTIVE DECEMBER 8, 2006 FBC1609.4, FBC
 R301.2.1.4.
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-06-06 Cont ID  
Sent By adarroug Date 2007-06-06 Time 10:14 Rev Time 0.00
Received By adarroug Date 2007-06-06 Time 10:14 Sent To B
Notes
2007-06-06 10:14:38TO "SHILL" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-06-06 Cont ID  
Sent By adarroug Date 2007-05-29 Time 10:13 Rev Time 0.00
Received By adarroug Date 2007-05-08 Time 10:21 Sent To  
Notes
2007-05-08 10:21:25TO "MISC" BOX#1