2007-05-23 07:44:33 | DENIED BY BUILDING | | | | 1) A RECORDED COPY OF THE NOTICE OF | | COMMENCEMENT MUST BE SUBMITTED BEFORE A | | PERMIT CAN BE ISSUED. | | | | 2) IN ADDITION TO THE FL COVERSHEETS, SUBMIT TWO COPIES | | OF NOA 05-1115.08 FOR THE GAF TIMBERLINE SHINGLES. | | | | 3) THE PRODUCT APPROVAL SUBMITTED IS FOR TAMKO MODIFIED | | ROOF SYSTEM OVER RECOVER DECKS. THE DESCRIPTION OF WORK | | ON THE PERMIT APPLICATION IS FOR TEAR OFF. PLEASE | | CLARIFY. | | NOTE: IF THIS IS A RECOVER (ROOF-OVER), A | | PRE-INSPECTION BY THIS DEPARTMENT IS REQUIRED TO | | DETERMINE THE EXISTING ROOF CONDITION. | | | | 4) SPECIFY ON THE PRODUCT APPROVAL WHICH ONE OF THE | | SYSTEMS WILL BE USED, WHICH ONE OF THE FASTENING | | OPTIONS AND UPLIFT PRESSURES WILL BE USED AND THE DECK | | TYPE (WOOD,CONCRETE, ETC.) | | | | 5) IF THE UPLIFT FOR THE SYSTEM REQUIRES ENHANCED | | FASTENING AND IT IS ALLOWED BY GENERAL LIMITATION | | NUMBER 7, SUBMIT RAS 117 CALCULATIONS. IF LIMITATION | | NUMBER 7 OF THEPRODUCT APPROVAL REQUIRES THE RAS 117 | | CALCULATIONS TO BE DONE BY AN ENGINEER, ARCHITECT OR | | REGISTERED ROOF CONSULTAN, THEY ARE REQUIRED TO BE | | SIGNED AND SEALED. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2007-05-11 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2007-05-11 |
Time |
11:37 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2007-05-11 |
Time |
11:37 |
Sent To |
|
|
Notes |
2007-05-11 12:11:07 | DENIED BY BUILDING | | | | 1)THE DESIGN PRESSURE OF 60 PSF FOR THE SELECTED | | SYSTEM ON PAGE 30 OF THE NOA IS TOO LOW FOR THE | | CORNERS. SUBMIT RAS 117 CALCULATIONS FROM A FLORIDA | | LICENSED ENGINEER, ARCHITECT OR REGISTERED ROOF | | CONSULTANT AS REQUIRED BY GENERAL LIMITATION NUMBER 7 | | ON PAGE 33 OF THE NOA FOR ENHANCED FASTENING. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2007-05-04 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-05-04 |
Time |
10:52 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-05-04 |
Time |
10:52 |
Sent To |
|
|
Notes |
2007-05-04 10:54:22 | ****CORRECTIONS**** | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBCFLORIDA BUILDING CODE 2004 | | FBC EBFLORIDA BUILDING CODE 2004 | | EXISTING BUILDING CODE | | FBC*CITY OF WEST PALM BEACH | | AMENDMENTS TO THE FBC2004 | | | | ROOFING PERMIT; ONLY CHECKED ITEMS APPLY | | | | ____1.)A NOTICE OF COMMENCEMENT MUST BE FILED WITH | | THE CLERK OF COURTS PRIOR TO PERMIT PICKUP, FS713.13. | | | | ____2.)CONTRACTOR IS TO PROVIDE THE FOLLOWING | | INFORMATION ON THE APPLICATION, SEE ATTACHED POLICY; | | MEAN ROOF HEIGHT, ROOF PITCH, ROOF DECK TYPE, AREA OF | | EACH ROOF TYPE | | | | ____3.)FLORIDA STATE OR LOCAL PRODUCT APPROVAL | | REQUIRED IN ADDITION TO THE EVALUATION REPORT | | SUBMITTED, FAC9B72.WWW.FLORIDABUILDING.ORG | | | | _XX_4.)FOR THE FLAT DECK, SELECT THE APPROVED | | ASSEMBLY YOU ARE USING.ALSO INDICATE WHICH FASTENER | | YOU ARE USING IF THE OPTIONS HAVE DIFFERENT PRESSURE | | LIMITATIONS. | | | | _XX_5.)FOR THE FLAT DECK, SPECIFY THE ENHANCED | | FASTENING FOR CORNER AND PERIMETER ZONES. | | | | ____ 6.)ON THE TILE PRODUCT APPROVAL, INDICATE WHICH | | METHOD OF ATTACHMENT YOU ARE USING. | | | | _XX_ 7.)YOU HAVE PROVIDED PAPERWORK SPECIFYING | | RAS150.THIS IS A PRESCRIPTIVE METHOD WHICH IS ALLOWED | | IN HIGH VELOCITY WHEN ADOPTED BY THE AHJ, FBC | | R4402.8.1.AS WE ARE NOT IN HIGH VELOCITY, YOU MUST | | FOLLOW MANUFACTURER'S INSTRUCTIONS (NOA IN THIS CASE) | | FOR INSTALLATION, FBC R905.11.3. | | |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
P |
Date |
2007-05-04 |
|
|
Cont ID |
|
Sent By |
swurafti |
Date |
2007-05-04 |
Time |
09:28 |
Rev Time |
0.00 |
Received By |
swurafti |
Date |
2007-05-04 |
Time |
09:28 |
Sent To |
|
|
Notes |
2007-05-04 09:28:54 | HISTORIC APPROVED BY GJUDGE |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2007-05-31 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-05-31 |
Time |
15:10 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-05-31 |
Time |
15:10 |
Sent To |
B |
|
Notes |
2007-05-31 15:11:15 | TO "RMCDOUGAL" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2007-05-17 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-05-17 |
Time |
10:00 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-05-17 |
Time |
10:00 |
Sent To |
B |
|
Notes |
2007-05-17 10:00:41 | TO "RMCDOUGAL" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2007-05-10 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-05-10 |
Time |
16:37 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-05-10 |
Time |
16:37 |
Sent To |
B |
|
Notes |
2007-05-10 16:37:47 | TO "RMCDOUGAL" DESK/RESUB |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |