Plan Review Stops For Permit 07050164 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
P |
Date |
2008-03-04 |
|
|
Cont ID |
|
Sent By |
kconrad |
Date |
2008-03-04 |
Time |
19:24 |
Rev Time |
0.00 |
Received By |
kconrad |
Date |
2008-03-04 |
Time |
17:49 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
F |
Date |
2008-01-31 |
|
|
Cont ID |
|
Sent By |
kconrad |
Date |
2008-01-31 |
Time |
18:55 |
Rev Time |
0.00 |
Received By |
kconrad |
Date |
2008-01-31 |
Time |
17:54 |
Sent To |
I |
|
Notes |
2008-01-31 18:53:38 | PROJECT: 213 MURRAY ROAD/ # 07050164/ OWNER REVISION | | | | PROJECT DETAIL: ENCLOSE CARPORT, ADD COVERED BREEZEWAY | | AND REMODEL KITCHEN. | | | | APPLICABLE CODE REVIEW: 2004 FLORIDA RESIDENTIAL/ | | BUILDING CODE WITH 2006 REVISIONS AND THE 2004 FEBC. | | | | STATUS: FAILED | | | | PLAN REVIEW COMMENTS: | | | | 1) PLEASE SUBMIT (2) COPIES OF THE PRODUCT APPROVALS | | FOR THE DOUBLE OUTSWING FRENCHDOORS W/ SIDELITES AND | | TRANSOM AS INDICATED ON SHEET 2.1. | | ALSO, SUBMIT MULLION BAR PRODUCT APPROVALS IF | | APPLICABLE. | | | | 2) PLEASE INDICATE THE FINISHED FLOOR ELEVATIONS: NEW | | SUNROOM SHOWS AN ELEVATION TRANSITION OF 6". THE | | INITIAL PLAN INDICATED THE FLOOR TO BE FLUSH WITH THE | | EXISTING FINISHED FLOOR. | | | | 3) PLEASE ADJUSTTHE PROJECT VALUATION TO REFLECT THE | | PROPOSED REVISIONS. | | | | 4) NOTES ON SHEET 2.1 HAVE BEEN MARKED OUT. THE AOR | | SHALL INITIAL AND DATE OR DELETE FROM PLAN. | | | | 5) THERE ARE TWO DETAILS REFERENCING SECTION 2/4.1: | | MISSING A WALL/ROOF FRAMING SECTION DETAIL FOR THE NEW | | SUNROOM HVAC CLOSET AND STORAGE ROOMS. | | | | 6) THE REVISION DATE WITHIN THE TITLE BLOCK IS | | 1/18/2007 SHOULD BE 1/18/2008?? | | | | END OF COMMENTS | | | | PLAN REVIEW: KEN CONRAD | | PHONE: 561.805.6666 | | E-MAIL: KCONRAD @WPB.ORG |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2007-10-29 |
|
|
Cont ID |
|
Sent By |
kconrad |
Date |
2007-10-29 |
Time |
18:29 |
Rev Time |
0.00 |
Received By |
kconrad |
Date |
2007-10-29 |
Time |
16:30 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2007-09-26 |
|
|
Cont ID |
|
Sent By |
kconrad |
Date |
2007-09-26 |
Time |
19:09 |
Rev Time |
0.00 |
Received By |
kconrad |
Date |
2007-09-26 |
Time |
17:59 |
Sent To |
I |
|
Notes |
2007-09-26 18:57:51 | PROJECT: 213 MURRAY ROAD/ # 07050164 | | | | PROJECT DETAIL: ENCLOSE CARPORT, ADD COVERED BREEZEWAY | | AND REMODEL KITCHEN. | | | | APPLICABLE CODE REVIEW: 2004 FLORIDA RESIDENTIAL/ | | BUILDING CODE WITH 2006 REVISIONS AND THE 2004 FEBC. | | | | STATUS: APPROVED | | | | PLAN REVIEW COMMENTS: | | | | NOTE: ITEMS MARKED "X" HAVE COMPLIED. | | | | | | | | X1) REQUIRE SHOP DRAWINGS FOR TS COLUMNS AS INDICATED | | ON SHEET 4.1. | | | | X2) PLEASE PROVIDE CLARIFICATION: SHEET 2.1 LOGGIA | | FOUNDATION PLAN INDICATES 3" DIAMETER STEEL COLUMN; | | DETAIL 3/4.1 REFLECTS 3.5 X 3.5" TS COLUMN. | | | | X3) SUBMIT PRODUCT APPROVALS FOR ALL FRAMING | | CONNECTORS. | | | | X4) PROVIDE DETAIL FOR NEW CMU WALLTO EXISTING CMU | | WALL CONNECTION. | | | | X5)SUBMIT EPOXY SPECIFICATIONS. | | | | X6) PROVIDE MECHANICAL ATTACHMENT DETAIL FOR IN-FILL | | WALL FRAMING TO CMU WALL. SEE DETAIL 1/4.1. | | | | X7) SPECIFY GRADE AND SPECIES OF LUMBER USED FOR WALL | | FRAMING, HEADERS AND BEAMS. | | | | X8) INDICATE LENGTH OF CARRIAGE BOLTS AND THE DIAMETER | | OF WASHERS TO BE INSTALLED. SEE WALL LEGEND, SHEET | | 2.1. | | | | X9) SHOW DETAILS OF 3X12 WOOD BEAM: MECHANICAL | | ATTACHMENT PATTERN AND SPLICE LOCATIONS IF APPLICABLE. | | | | X10) PROVIDE DETAILS INDICATING THE ATTACHMENT OF THE | | NEW LOGGIA ROOF TO THE EXISTING GARAGE ROOF FRAMING. | | | | X11) PLEASE SHOW SECTION MARK 2/4.1 ON SHEET 2.1 OR | | 3.1. | | | | X12) PLAN INDICATES 4043 SINGLE HUNG WINDOW | | INSTALLATION; THE SUBMITTED P/A'S ARE FOR CASEMENT | | WINDOWS. PLEASE CLARIFY. | | | | X13) PROVIDE COLUMN WRAP DETAIL. | | | | X14)WOOD BUCKS SHALL CONFORM TO THE FOLLOWING | | BUILDING CODE SECTION: | | | | 1714.5.4.2 MASONRY, CONCRETE OR OTHER STRUCTURAL | | SUBSTRATE. | | WHERE THE WOOD SHIM OR BUCK THICKNESS IS LESS THAN 1? | | INCHES (38 MM), WINDOW AND DOOR ASSEMBLIES SHALL BE | | ANCHORED THROUGH THE MAIN FRAME OR BY JAMB CLIP OR | | SUBFRAME SYSTEM, IN ACCORDANCE WITH THE MANUFACTURER?S | | PUBLISHED INSTALLATION INSTRUCTIONS. ANCHORS SHALL BE | | SECURELY FASTENED DIRECTLY INTO THE MASONRY, CONCRETE | | OR OTHER STRUCTURAL SUBSTRATE MATERIAL. UNLESS | | OTHERWISE TESTED, BUCKS SHALL EXTEND BEYOND THE | | INTERIOR FACE OF THE WINDOW OR DOOR FRAME SUCH THAT | | FULL SUPPORT OF THE FRAME IS PROVIDED. SHIMS SHALL BE | | MADE FROM MATERIALS CAPABLE OF SUSTAINING APPLICABLE | | LOADS, LOCATED AND APPLIED IN A THICKNESS CAPABLE OF | | SUSTAINING APPLICABLE LOADS. ANCHORS SHALL BE PROVIDED | | TO TRANSFER LOAD FROM THE WINDOW OR DOOR FRAME TO THE | | ROUGH OPENING SUBSTRATE. | | WHERE THE WOOD BUCK THICKNESS IS 1? INCHES (38 MM) OR | | GREATER, THE BUCK SHALL BE SECURELY FASTENED TO | | TRANSFER LOAD TO THE MASONRY, CONCRETE OR OTHER | | STRUCTURAL SUBTRATE AND THE BUCK SHALL EXTEND BEYOND | | THE INTERIOR FACE OF THE WINDOW OR DOOR FRAME.WINDOW | | AND DOOR ASSEMBLIES SHALL BE ANCHORED THROUGH THE MAIN | | FRAME OR BY JAMB CLIP OR SUBFRAME SYSTEM OR THROUGH THE | | FLANGE TO THE SECURED WOOD BUCK IN ACCORDANCE WITH THE | | MANUFACTURER?S PUBLISHED INSTALLATION INSTRUCTIONS. | | UNLESS OTHERWISE TESTED, BUCKS SHALL EXTEND BEYOND THE | | INTERIOR FACE OF THE WINDOW OR DOOR FRAME SUCH THAT | | FULL SUPPORT OF THE FRAME IS PROVIDED. SHIMS SHALL BE | | MADE FROM MATERIALS CAPABLE OF SUSTAINING APPLICABLE | | LOADS, LOCATED AND APPLIED IN A THICKNESS CAPABLE OF | | SUSTAINING APPLICABLE LOADS. ANCHORS SHALL BE PROVIDED | | TO TRANSFER LOAD FROM THE WINDOW OR DOOR FRAME ASSEMBLY | | TO THE SECURED WOOD BUCK. | | | | X15)607.2REDUCTION OF STRENGTH. | | ALTERATIONS SHALL NOT REDUCE THE STRUCTURAL STRENGTH OR | | STABILITY OF THE BUILDING, STRUCTURE, OR ANY INDIVIDUAL | | MEMBER THEREOF. | | EXCEPTION: SUCH REDUCTION SHALL BE ALLOWED AS LONG AS | | THE STRENGTH AND THE STABILITY OF THE BUILDING ARE NOT | | REDUCED TO BELOW THE FLORIDA BUILDING CODE, BUILDING | | LEVELS. | | | | 607.3NEW STRUCTURAL MEMBERS. | | NEW STRUCTURAL MEMBERS IN ALTERATIONS, INCLUDING | | CONNECTIONS AND ANCHORAGE, SHALL COMPLY WITH THE | | FLORIDA BUILDING CODE, BUILDING. | | | | X16) PLEASE SHOW ALLEXTERIOR BUILDING ELEVATIONS: | | | | 106.3.5 MINIMUM PLAN REVIEW CRITERIA FOR | | BUILDINGS. | | THE EXAMINATION OF THE DOCUMENTS BY THE BUILDING | | OFFICIAL SHALL INCLUDE THE FOLLOWING MINIMUM CRITERIA | | AND DOCUMENTS: A FLOOR PLAN; SITE PLAN; FOUNDATION | | PLAN; FLOOR/ROOF FRAMING PLAN OR TRUSS LAYOUT; AND ALL | | EXTERIOR ELEVATIONS: | | | | RESIDENTIAL (ONE- AND TWO-FAMILY):STRUCTURAL | | REQUIREMENTS SHALL INCLUDE: | | WALL SECTION FROM FOUNDATION THROUGH ROOF, INCLUDING | | ASSEMBLY AND MATERIALS CONNECTOR TABLES WIND | | REQUIREMENTS STRUCTURAL CALCULATIONS (IF REQUIRED) . | | RESIDENTIAL (ONE- AND TWO-FAMILY) | | | | | | | | | | PLAN REVIEW: KEN CONRAD | | PHONE: 561.805.6666 | | FAX:561.805.6676 | 2007-09-26 18:06:06 | PROJECT: |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2007-06-21 |
|
|
Cont ID |
|
Sent By |
kconrad |
Date |
2007-06-21 |
Time |
20:05 |
Rev Time |
0.00 |
Received By |
kconrad |
Date |
2007-06-21 |
Time |
16:19 |
Sent To |
I |
|
Notes |
2007-06-21 19:28:00 | PROJECT: 213 MURRAY ROAD/ # 07050164 | | | | PROJECT DETAIL: ENCLOSE CARPORT, ADD COVERED BREEZEWAY | | AND REMODEL KITCHEN. | | | | APPLICABLE CODE REVIEW: 2004 FLORIDA RESIDENTIAL/ | | BUILDING CODE WITH 2006 REVISIONS AND THE 2004 FEBC. | | | | STATUS: DENIED | | | | | | PLAN REVIEW COMMENTS: | | | | | | 106.3.5 MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS. THE | | EXAMINATION OF THE DOCUMENTS BY THE BUILDING OFFICIAL | | SHALL INCLUDE THE FOLLOWING MINIMUM CRITERIA AND | | DOCUMENTS: A FLOOR PLAN; SITE PLAN; FOUNDATION PLAN; | | FLOOR/ROOF FRAMING PLAN OR TRUSS LAYOUT; AND ALL | | EXTERIOR ELEVATIONS: | | | | RESIDENTIAL (ONE- AND TWO-FAMILY): | | 6. STRUCTURAL REQUIREMENTS SHALL INCLUDE: | | WALL SECTION FROM FOUNDATION THROUGH ROOF, INCLUDING | | ASSEMBLY AND MATERIALS CONNECTOR TABLES WIND | | REQUIREMENTS STRUCTURAL CALCULATIONS (IF REQUIRED) | | | | | | 1) REQUIRE SHOP DRAWINGS FOR TS COLUMNS AS INDICATED ON | | SHEET 4.1. | | | | 2) PLEASE PROVIDE CLARIFICATION: SHEET 2.1 LOGGIA | | FOUNDATION PLAN INDICATES 3" DIAMETER STEEL COLUMN; | | DETAIL 3/4.1 REFLECTS 3.5 X 3.5" TS COLUMN. | | | | 3) SUBMIT PRODUCT APPROVALS FOR ALL FRAMING | | CONNECTORS. | | | | 4) PROVIDE DETAIL FOR NEW CMU WALLTO EXISTING CMU | | WALL CONNECTION. | | | | 5) SUBMIT EPOXY SPECIFICATIONS. | | | | 6) PROVIDE MECHANICAL ATTACHMENT DETAIL FOR IN-FILL | | WALL FRAMING TO CMU WALL. SEE DETAIL 1/4.1. | | | | 7) SPECIFY GRADE AND SPECIES OF LUMBER USED FOR WALL | | FRAMING, HEADERS AND BEAMS. | | | | 8) INDICATE LENGTH OF CARRIAGE BOLTS AND THE DIAMETER | | OF WASHERS TO BE INSTALLED. SEE WALL LEGEND, SHEET | | 2.1. | | | | 9) SHOW DETAILS OF 3X12 WOOD BEAM: MECHANICAL | | ATTACHMENT PATTERN AND SPLICE LOCATIONS IF APPLICABLE. | | | | 10) PROVIDE DETAILS INDICATING THE ATTACHMENT OF THE | | NEW LOGGIA ROOF TO THE EXISTING GARAGE ROOF FRAMING. | | | | 11) PLEASE SHOW SECTION MARK 2/4.1 ON SHEET 2.1 OR | | 3.1. | | | | 12) PLAN INDICATES 4043 SINGLE HUNG WINDOW | | INSTALLATION; THE SUBMITTED P/A'S ARE FOR CASEMENT | | WINDOWS. PLEASE CLARIFY. | | | | 13) PROVIDE COLUMN WRAP DETAIL. | | | | 14)WOOD BUCKS SHALL CONFORM TO THE FOLLOWING BUILDING | | CODE SECTION: | | | | 1714.5.4.2 MASONRY, CONCRETE OR OTHER STRUCTURAL | | SUBSTRATE. | | WHERE THE WOOD SHIM OR BUCK THICKNESS IS LESS THAN 1? | | INCHES (38 MM), WINDOW AND DOOR ASSEMBLIES SHALL BE | | ANCHORED THROUGH THE MAIN FRAME OR BY JAMB CLIP OR | | SUBFRAME SYSTEM, IN ACCORDANCE WITH THE MANUFACTURER?S | | PUBLISHED INSTALLATION INSTRUCTIONS. ANCHORS SHALL BE | | SECURELY FASTENED DIRECTLY INTO THE MASONRY, CONCRETE | | OR OTHER STRUCTURAL SUBSTRATE MATERIAL. UNLESS | | OTHERWISE TESTED, BUCKS SHALL EXTEND BEYOND THE | | INTERIOR FACE OF THE WINDOW OR DOOR FRAME SUCH THAT | | FULL SUPPORT OF THE FRAME IS PROVIDED. SHIMS SHALL BE | | MADE FROM MATERIALS CAPABLE OF SUSTAINING APPLICABLE | | LOADS, LOCATED AND APPLIED IN A THICKNESS CAPABLE OF | | SUSTAINING APPLICABLE LOADS. ANCHORS SHALL BE PROVIDED | | TO TRANSFER LOAD FROM THE WINDOW OR DOOR FRAME TO THE | | ROUGH OPENING SUBSTRATE. | | WHERE THE WOOD BUCK THICKNESS IS 1? INCHES (38 MM) OR | | GREATER, THE BUCK SHALL BE SECURELY FASTENED TO | | TRANSFER LOAD TO THE MASONRY, CONCRETE OR OTHER | | STRUCTURAL SUBTRATE AND THE BUCK SHALL EXTEND BEYOND | | THE INTERIOR FACE OF THE WINDOW OR DOOR FRAME.WINDOW | | AND DOOR ASSEMBLIES SHALL BE ANCHORED THROUGH THE MAIN | | FRAME OR BY JAMB CLIP OR SUBFRAME SYSTEM OR THROUGH THE | | FLANGE TO THE SECURED WOOD BUCK IN ACCORDANCE WITH THE | | MANUFACTURER?S PUBLISHED INSTALLATION INSTRUCTIONS. | | UNLESS OTHERWISE TESTED, BUCKS SHALL EXTEND BEYOND THE | | INTERIOR FACE OF THE WINDOW OR DOOR FRAME SUCH THAT | | FULL SUPPORT OF THE FRAME IS PROVIDED. SHIMS SHALL BE | | MADE FROM MATERIALS CAPABLE OF SUSTAINING APPLICABLE | | LOADS, LOCATED AND APPLIED IN A THICKNESS CAPABLE OF | | SUSTAINING APPLICABLE LOADS. ANCHORS SHALL BE PROVIDED | | TO TRANSFER LOAD FROM THE WINDOW OR DOOR FRAME ASSEMBLY | | TO THE SECURED WOOD BUCK. | | | | 15)607.2REDUCTION OF STRENGTH. | | ALTERATIONS SHALL NOT REDUCE THE STRUCTURAL STRENGTH OR | | STABILITY OF THE BUILDING, STRUCTURE, OR ANY INDIVIDUAL | | MEMBER THEREOF. | | EXCEPTION: SUCH REDUCTION SHALL BE ALLOWED AS LONG AS | | THE STRENGTH AND THE STABILITY OF THE BUILDING ARE NOT | | REDUCED TO BELOW THE FLORIDA BUILDING CODE, BUILDING | | LEVELS. | | | | 607.3NEW STRUCTURAL MEMBERS. | | NEW STRUCTURAL MEMBERS IN ALTERATIONS, INCLUDING | | CONNECTIONS AND ANCHORAGE, SHALL COMPLY WITH THE | | FLORIDA BUILDING CODE, BUILDING. | | | | 16) PLEASE SHOW ALLEXTERIOR BUILDING ELEVATIONS: | | | | 106.3.5 MINIMUM PLAN REVIEW CRITERIA FOR | | BUILDINGS. | | THE EXAMINATION OF THE DOCUMENTS BY THE BUILDING | | OFFICIAL SHALL INCLUDE THE FOLLOWING MINIMUM CRITERIA | | AND DOCUMENTS: A FLOOR PLAN; SITE PLAN; FOUNDATION | | PLAN; FLOOR/ROOF FRAMING PLAN OR TRUSS LAYOUT; AND ALL | | EXTERIOR ELEVATIONS: | | | | RESIDENTIAL (ONE- AND TWO-FAMILY) | | | | | | | | | | PLAN REVIEW: KEN CONRAD | | PHONE: 561.805.6666 | | FAX:561.805.6676 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
5 |
Status |
P |
Date |
2008-03-03 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2008-03-03 |
Time |
08:40 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2008-03-03 |
Time |
08:23 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
F |
Date |
2008-01-30 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2008-01-30 |
Time |
12:16 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2008-01-30 |
Time |
11:51 |
Sent To |
M |
|
Notes |
2008-01-30 12:16:23 | | | | | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE | | CYCLES: | | | | THE 2004 FLORIDA BUILDING CODE, 2007 REVISIONS, 2004 | | RESIDENTIAL BUILDING CODE, 2005 NEC, NFPA-72 2002, | | NFPA-101 2003, 2004 FBC AS AMENDED, CHAPTER 1.AND FOUND | | NONCOMPLIANT WITH THE FOLLOWING: | | | | 1} THE PERSON TAKING RESPONSIBILITY FOR THE DESIGN MUST | | PRINT AND SIGN THEIR NAME TO SAME, ALL SHEETS, PER | | 106.1.3.FBC. | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | BILL TROBAUGH | | ELECTRICAL PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561/805-6718 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2007-10-25 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2007-10-25 |
Time |
07:27 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2007-10-25 |
Time |
06:48 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2007-09-18 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2007-09-18 |
Time |
15:30 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2007-09-18 |
Time |
15:22 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2007-05-11 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2007-05-11 |
Time |
12:17 |
Rev Time |
0.33 |
Received By |
btrobaug |
Date |
2007-05-11 |
Time |
12:15 |
Sent To |
M |
|
Notes |
2007-05-11 12:17:45 | | | | | | | NONCOMPLIANT | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS FOR CODE | | COMPLIANCE AND RESUBMIT FOR REVIEW. | | | | THE PERSON TAKING RESPONSIBILITY FOR THE DESIGN MUST | | PRINT AND SIGN THEIR NAME TO SAME PER 106.3.4.3. FBC. | | IF AN ARCHITECT OR ENGINEER, COMPLY WITH 418 AND 417 | | FS, RESPECTIVELY. | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | BILL TROBAUGH | | ELECTRICAL PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561/805-6718 | | [email protected] |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2008-02-28 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-02-28 |
Time |
09:46 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-02-28 |
Time |
09:46 |
Sent To |
Z |
|
Notes |
2008-02-28 09:46:43 | TO "Z" BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2008-01-25 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2008-01-25 |
Time |
11:27 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2008-01-25 |
Time |
11:27 |
Sent To |
Z |
|
Notes |
2008-01-25 11:27:44 | TO "Z" BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2007-10-17 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-10-17 |
Time |
16:11 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-10-17 |
Time |
16:11 |
Sent To |
Z |
|
Notes |
2007-10-17 16:11:31 | TO "Z" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2007-09-12 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-09-12 |
Time |
12:15 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-09-12 |
Time |
12:15 |
Sent To |
Z |
|
Notes |
2007-09-12 12:15:46 | TO "Z" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2007-05-10 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-05-10 |
Time |
10:11 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-05-10 |
Time |
10:11 |
Sent To |
E |
|
Notes |
2007-05-10 10:11:28 | TO "SFR" "E" |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2007-06-22 |
|
|
Cont ID |
|
Sent By |
kconrad |
Date |
2007-06-22 |
Time |
15:32 |
Rev Time |
0.00 |
Received By |
kconrad |
Date |
2007-05-07 |
Time |
14:34 |
Sent To |
I |
|
Notes |
2007-05-07 14:34:57 | TO "Z" BOX |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
5 |
Status |
P |
Date |
2008-03-03 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2008-03-03 |
Time |
11:25 |
Rev Time |
0.20 |
Received By |
tgordon |
Date |
2008-03-03 |
Time |
11:24 |
Sent To |
B |
|
Notes |
2008-03-03 11:25:44 | REVISION TO MECH. PLAN. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
F |
Date |
2008-01-30 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2008-01-30 |
Time |
16:33 |
Rev Time |
0.30 |
Received By |
tgordon |
Date |
2008-01-30 |
Time |
16:33 |
Sent To |
B |
|
Notes |
2008-01-30 16:41:37 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM | | BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | (F.S.). | | | | ** MECHANICAL REVISION ** | | *** DENIED *** | | 1) PLEASE SUBMITCOOLING LOAD CALCULATIONS AS A NEW | | SYSTEM IS BEING INSTALLED, SEE 2004 FBC 13-607.1.ABC.1 | | OR 13-407.1.ABC.1. | | | | 2) PLEASE SHOW THE LOCATION OF THE NEW A/C CONDENSER | | UNIT ON PLAN 3.1, SEE 2004 FBC/R M1307.3. | | | | 3) PLEASE SHOW AN A/C EQUIPMENT SCHEDULE ON PLAN 3.1 | | WITH ALL PERTINENT INFORMATION, SEE 2004 WPB AMEND. | | 106.3.5.4 (10). | | | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729 | | E-MAIL; [email protected] |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2007-10-26 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2007-10-26 |
Time |
08:14 |
Rev Time |
0.30 |
Received By |
tgordon |
Date |
2007-10-26 |
Time |
08:14 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2007-09-19 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2007-09-19 |
Time |
09:21 |
Rev Time |
0.30 |
Received By |
tgordon |
Date |
2007-09-19 |
Time |
09:21 |
Sent To |
P |
|
Notes |
2007-09-19 09:38:50 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | REFERENCED CODES WITH 05, 06 REVISIONS, CITY OF WEST | | PALM BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | (F.S.). | | | | *** DENIED *** | | 1) AS NOTED IN LAST REVIEW, ENERGY CALCULATIONS NEED TO | | BE ON FORM600C-04R NOT FORM 600-04, SEE 2004 FBC | | 13-600.3.C. | | | | 2) WHEN SUBMITTING THE 'CORRECT' ENERGY CALCULATIONS | | HAVE THEM SIGNED BY THE OWNER/AGENT ALSO, PER 2004 FBC | | 13-600.3.ABC.2. | | | | 3) ENERGY CALCULATIONS LINE 9A1 SHOW WALL INSULATION IS | | R-5. PLANS PAGE 4.1 DETAIL 2/4.1 SHOWS NO INSULATION ON | | THE WALLS, SEE FBC 13-103.2. PLEASE CORRECT. | | | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729 | | E-MAIL; [email protected] |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2007-05-15 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2007-05-15 |
Time |
14:03 |
Rev Time |
0.20 |
Received By |
tgordon |
Date |
2007-05-15 |
Time |
14:03 |
Sent To |
P |
|
Notes |
2007-05-15 14:12:24 | *** DENIED *** | | 1) ENERGY CALCULATIONS NEED TO BE ON FORM600C-04R, | | SEE 2004 FBC 13-600.3.C (12-8-06 REVISION). | | | | 2) WHEN SUBMITTING REVISED ENERGY CALCULATIONS HAVE | | THEM SIGNED BY THE OWNER/AGENT ALSO, PER 2004 FBC | | 13-600.3.ABC.2. | | | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
N |
Date |
2007-09-26 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2007-09-26 |
Time |
15:56 |
Rev Time |
0.00 |
Received By |
mperson |
Date |
2007-09-26 |
Time |
15:56 |
Sent To |
B |
|
Notes |
2007-09-26 15:58:26 | NOTE: RESUBMITTED PERMIT APPLICATION DELETED KITCHEN | | REMODEL. THERE IS NO PLUMBING ON RESUBMITTED PLANS. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2007-05-18 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2007-05-18 |
Time |
08:47 |
Rev Time |
0.33 |
Received By |
mperson |
Date |
2007-05-18 |
Time |
08:47 |
Sent To |
B |
|
Notes |
2007-05-18 09:02:40 | DENIED | | REFERENCE: | | ** FBC-2004 PLUMBING. | | ** FBC-2004 CHAPTER 1, THE CITY OF | | WEST PALM BEACH AMENDMENTS. | | | | THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR | | PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE: | | | | 1. THE PERMIT APPLICATION IS INDICATING "REMODEL | | KITCHEN". THE SUBMITTED PRINTS DO NOT INDICATE ANY | | KITCHEN REMODEL. | | NOTE: MORE INFORMATION IS REQUIRED. PLEASE | | INDICATE ON THE DRAWING THE EXISTING KITCHEN LAYOUT, | | AND ON A SEPERATE DRAWING PLEASE INDICATE THE NEW | | PROPOSED | | KITCHEN LAYOUT. | | A} IF KITCHEN REMODEL PLUMBING LAYOUT IS THE SAME | | WITH NO CHANGES, PLEASE INDICATE THIS ON | | THE DRAWING. | | B} IF KITCHEN REMODEL PLUMBING LAYOUT IS THE | | SAME AND THE PLUMBING FIXTURES ARE TO BE | | CHANGED, PLEASE INDCATE ON THE DRAWING. | | "EXACT FIXTURE CHANGE OUT ONLY." | | C} IF THE PROPOSED KITCHEN REMODEL PLUMBING LAYOUT IS | | DIFFERENT FROM THE EXISTING PLEASE FOLLOW WHAT IS | | REQUIRED IN COMMENT #2. | | | | 2. PER FBC-2004 CHAPTER 1, SECTION 106.3.5.4 | | RESIDENTIAL (ONE AND TWO-FAMILY) PLEASE SUBMIT A | | PLUMBING SANITARY ISOMETRIC RISER DIAGRAM INDICATING | | ALL WASTE, VENTS, TRAPS AND SIZES WITH CLEANOUT | | LOCATIONS. | | | | END OF COMMENTS: | | | | REVIEW BY MIKE PERSON | | (561) 805-6730 | | FAX (561) 805-6731 | | E-MAIL [email protected] | | UNDER SUPERVISION OF K.STEVENS | | (561) 805-6721 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
5 |
Status |
P |
Date |
2008-02-28 |
|
|
Cont ID |
|
Sent By |
choops |
Date |
2008-02-28 |
Time |
13:57 |
Rev Time |
0.00 |
Received By |
choops |
Date |
2008-02-28 |
Time |
13:57 |
Sent To |
E |
|
Notes |
2008-02-28 13:59:13 | ***APPROVED - REVISION - CHANGE WINDOWS TO DOORS IN SUN | | ROOM, ADD A/C CLOSET*** | | | | PROVISOS: | | 1)APPROVED TO ENCLOSE EXISTING CARPORT, ALL NEW | | CONSTRUCTION SHALL MEET CURRENT SETBACK REGULATIONS | | FOUND IN SECTION 94-74 OF THE CITY'S ZONING AND LAND | | DEVELOPMENT REGULATIONS. | | 2)NO NEW NONCONFORMITY SHALL BE CREATED.NO | | EXISTING NONCONFORMITY SHALL BE ENLARGED OR INCREASED. | | | | 3)MECHANICAL EQUIPMENT SHALL NOT PROJECT MORE THAN 4 | | FEET INTO A REQUIRED SETBACK. | | | | | | | | | | SENT TO "E" - BT |
|
|
Review Stop |
Z |
ZONING |
Rev No |
4 |
Status |
F |
Date |
2008-01-28 |
|
|
Cont ID |
|
Sent By |
choops |
Date |
2008-01-28 |
Time |
14:11 |
Rev Time |
0.00 |
Received By |
choops |
Date |
2008-01-28 |
Time |
14:11 |
Sent To |
E |
|
Notes |
2008-01-28 14:06:49 | *** FAILED - REVISION - CHANGE WINDOWS TO DOORS IN SUN | | ROOM, ADD A/C CLOSET*** | | | | | | 1)PROVIDE TWO (2) COPIES OF A CURRENT SURVEY SHOWING | | THE LOCATION OF THE PROPOSED WITH DIMENSIONS AND | | SETBACK DIMENSIONS TO ALL PROPERTY LINES.NOTE:ANY | | NEW CONSTRUCTION MUST MEET CURRENT REGULATIONS, SETBACK | | REQUIREMENTS CAN BE FOUND IN SECTION 94-74 OF THE | | ZONING AND LAND DEVELOPMENT REGULATIONS (ZLDRS). | | | | 2)AS THE EXISTING STRUCTURE IS A NONCONFORMING | | STRUCTURE, NOTHING NEW WILL BE PERMITTED TO BE BUILT | | UNLESS IT MEETS CURRENT REGULATIONS FOUND IN THE | | AFOREMENTIONED SECTION OF THE ZLDRS.THE NEWLY | | SUBMITTED PLANS SHOW AN EXTENSION OF THE EXISTING | | NONCONFORMING STRUCTURE OTHER THAN WHAT WAS ORIGINALLY | | PERMITTED.THIS IS NOT ALLOWABLE, NO NEW NONCONFORMITY | | SHALL BE CREATED OR EXISTING NONCONFORMITY ENLARGED. | | | | 3)INDICATE SETBACK DIMENSIONS FROM ANY PROPOSED A/C | | EQUIPMENT TO ALL PROPERTY LINES.AS PER SECTION | | 94-305(B)(4) OF THE ZLDRS: MECHANICAL EQUIPMENT MAY NOT | | PROJECT MORE THAN 4' INTO A REQUIRED SETBACK. | | | | | | QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, | | ZONING TECHNICIAN (561)805-6720 | | | | | | | | | | | | SENT TO "E" - BT |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2007-10-22 |
|
|
Cont ID |
|
Sent By |
choops |
Date |
2007-10-22 |
Time |
13:50 |
Rev Time |
0.00 |
Received By |
choops |
Date |
2007-10-22 |
Time |
13:50 |
Sent To |
E |
|
Notes |
2007-10-22 13:50:57 | ***APPROVED - RESUB #2*** | | | | PROVISO - NO NEW NONCONFORMITY SHALL BE CREATED OR | | EXISTING NONCONFORMITY ENLARGED. | | | | SENT TO "E" - BT |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2007-09-14 |
|
|
Cont ID |
|
Sent By |
choops |
Date |
2007-09-14 |
Time |
11:33 |
Rev Time |
0.00 |
Received By |
choops |
Date |
2007-09-14 |
Time |
11:33 |
Sent To |
E |
|
Notes |
2007-09-14 11:49:06 | ***FAILED - RESUB #1*** | | | | | | 1)PLEASE PROVIDE A FLOOR PLAN SHOWING THE REMODEL OF | | THE KITCHEN AND 2ND FLOOR ABOVE THE CARPORT SHOWING THE | | INTERCONNECTIVITY WITH THE REMAINDER OF THE HOUSE. | | (REPEAT COMMENT) | | | | 2)CLARIFY IF PROPOSED DRIVEWAY IS TO BE INCLUDE IN | | THE SCOPE OF WORK UNDER THIS PERMIT.IF SO, ADD TO | | VALUE AND ADJUST FEES AND PROVIDE SQUARE FOOTAGE OF | | PROPOSED AND EXISTING, ALSO INDICATE IF APPROACH TO BE | | DONE OR NOT.IF NOT INCLUDED IN SCOPE OF WORK LABEL | | "TO BE PERMITTED SEPARATELY"(REPEAT COMMENT) | | | | 3)SHEETS 1.1 AND 5.1 SHOW PROPOSED LOGGIA STILL | | CONNECTING THE PRINCIPAL STRUCTURE AND THE GUEST | | HOUSE...REVISE TO SHOW A MINIMUM OF 6' SEPARATION. | | | | 4)SURVEYS AND SITE PLANS DO NOT MATCH.SURVEY, | | INCLUDING NORTH ELEVATION OF SHEET AD.1 SHOWS PROPOSED | | LOGGIA EXTENDING FROM PRINCIPAL STRUCTURE...OTHER PAGES | | SHOW EXTENDING FROM GUEST HOUSE.CLARIFY. | | | | 5)PLEASE PROVIDE FLOOR PLAN OF GUEST HOUSE.CITY | | RECORDS SHOW IT ORIGINALLY CONSTRUCTED AS A UTILITY | | BUILDING.PROVIDE PROOF (RECORDS OF BUILDING PERMIT) | | THAT IT WAS LEGALLY CONVERTED. | | | | | | QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, ZONING | | TECHNICIAN | | (561)805-6720 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2007-05-08 |
|
|
Cont ID |
|
Sent By |
choops |
Date |
2007-05-08 |
Time |
17:10 |
Rev Time |
0.00 |
Received By |
choops |
Date |
2007-05-08 |
Time |
17:10 |
Sent To |
I |
|
Notes |
2007-05-08 17:17:45 | ***FAILED *** | | | | | | 1)PLEASE PROVIDE FLOOR PLANS SHOWING REMODEL OF | | KITCHEN, ALSO SHOWING IF CARPORT IS 2 STORIES OR NOT. | | | | 2)SHOW ELEVATIONS FOR ALL SIDES | | | | 3)PLEASE SHOW SCOPE OF WORK ON BOTH COPIES OF SURVEYS | | WITH DIMENSIONS OF PROJECTS, AND DIMENSIONS TO PROPERTY | | LINES. | | | | 4)DRIVEWAY MUST BE UNDER A SEPERATE PERMIT. | | | | 5)SPECIFY IF GARAGE IS A GARAGE OR A GUEST HOUSE | | | | 6)THE CONNECTION OF THIS ROOFED BREEZEWAY FROM | | RESIDENCE TO GARAGE QUALIFIES THE GARAGE AS A PRINCIPAL | | STRUCTURE AND IS SUBJECT TO THE PRINCIPAL STRUCTURE'S | | SETBACK REQUIREMENTS (WHICH IT DOES NOT MEET) THE ONLY | | WAY IT WOULD BE PERMITTED IS IF THE BREEZEWAY IS | | COVERED(ROOFED) BY CANVAS, NOT ACTUALLY ROOFED IN. | | | | | | CHRIS HOOPS | | ZONING TECHNICIAN | | 561-805-6720 |
|
|