Plan Review Details - Permit 07041005
Plan Review Stops For Permit 07041005 |
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2008-01-02 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2008-01-02 |
Time |
12:33 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2008-01-02 |
Time |
12:26 |
Sent To |
|
|
Notes |
2008-01-02 12:32:40 | *****RECEIVED***** | | | | | | RECEIVED TWO LETTERS FROM SPRINKLER CONTRACTOR IN | | REFERENCE TO PRESSURE TEST EXCEPTION AS PER NFPA 13. | | ONE COPY FILED AT CSD AND THE OTHER IN THE FILES OF THE | | FIRE PREVENTION BUREAU. | | | | | | CAPT. MICHAEL A. WILLIAMS | | FIRE PLAN REVIEW | | 561-805-6722 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2007-12-17 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2007-12-17 |
Time |
14:56 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2007-12-17 |
Time |
14:36 |
Sent To |
|
|
Notes |
2007-12-17 14:43:13 | *****APPROVED REVISION***** | | | | | | REVISED PLAN SHEET FP1 OF FP1 STAMPED, INITIALED, AND | | DATED. | | | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2007-05-14 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2007-05-14 |
Time |
10:02 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2007-05-14 |
Time |
14:35 |
Sent To |
|
|
Notes |
2007-05-14 10:00:50 | *****APPROVED*****W/ REMINDER | | | | | | PLAN SHEET FP1 OF FP1 STAMPED, INITIALED, AND DATED; | | READY FOR PERMIT ISSUANCE. | | | | | | THE ADDITION OR MODIFICATION OF THE SPRINKLER SYSTEM | | SHALL BE HYDROSTATICALLY TESTED AT 200 PSI FOR TWO (2) | | HOURS;HOWEVER IF THE MODIFICATION CANNOT BE ISOLATED | | AS PER EXCEPTION INNFPA 13 - 2002 EDITION,PLEASE | | SUBMIT AT THE TIME OF INSPECTION ON YOUR OFFICIAL | | LETTERHEAD:THE LOCATION OF THE SCOPE OF WORK, THE | | PERMIT NUMBER, THE CODE REFERENCE AND LANGUAGE,TO BE | | FILED BY WPB FIRE PREVENTION. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2007-12-20 |
|
|
Cont ID |
|
Sent By |
mmiller |
Date |
2007-12-20 |
Time |
17:27 |
Rev Time |
0.00 |
Received By |
mmiller |
Date |
2007-12-20 |
Time |
17:27 |
Sent To |
|
|
Notes |
2007-12-20 17:27:21 | SENT TO FIRE INBOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2007-05-11 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2007-05-11 |
Time |
12:39 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2007-05-02 |
Time |
11:08 |
Sent To |
|
|
Notes |
2007-05-02 11:09:17 | TO "F" BOX |
|
|
|