Plan Review Details - Permit 07040851
Plan Review Stops For Permit 07040851 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2007-06-05 |
|
|
Cont ID |
|
Sent By |
amorse |
Date |
2007-06-05 |
Time |
16:39 |
Rev Time |
0.00 |
Received By |
amorse |
Date |
2007-06-05 |
Time |
16:39 |
Sent To |
B |
|
Notes |
2007-06-05 16:39:29 | | | PASSED | | | | *******NOTE********** | | | | TO EXPEDITE PLAN REVIEW ALL INFO AND PROCEDURES PER | | CITY OF WEST PALM MEMO MUST BE MET. 2 COPIES OF | | SCHEDULE COMPLETED AS REQUIRED, PRODUCT APPROVALS SHALL | | ONLY CIRCLE THE APPROPRIATE METHODS THAT WILL BE USED | | AND THE CORRECT TOP AND BOTTOM CONNECTION TYPES. IF | | THESE DO NOT MATCH REVIEW TAKES MUCH LONGER AS WE TRY | | TO ESTABLISH WHAT YOU ARE USING AND END UP FAILING THE | | REVIEW DUE TO CONFLICTING INFORMATION. PLEASE NOTE THAT | | USING THE WORST CASE DESIGN PRESSURES ESPECIALLY ON THE | | LARGER OPENINGS INSTEAD OF THE CORRECT PRESSURE COULD | | LEAD TO THE SHUTTER NOT BEING DESIGNED FOR USE | | REQUIRED. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2007-05-12 |
|
|
Cont ID |
|
Sent By |
amorse |
Date |
2007-05-12 |
Time |
17:00 |
Rev Time |
0.00 |
Received By |
amorse |
Date |
2007-05-12 |
Time |
17:00 |
Sent To |
PC |
|
Notes |
2007-05-12 17:03:25 | | | | | DENIED | | | | 1)DESIGN PRESSURE IN THE 2004 FBC HAVE BEEN UPDATED | | WITH THE 2006 AMENDMENTS, ANY BUILDING IN A NORMALLY | | EXPOSURE BCATEGORY THAT HAS OPEN TERRAIN (INCLUDES | | BODIES OF WATER, GOLF COURSES, ETC) IN ANY QUADRANT FOR | | A DISTANCE OF 600 FT WILL BE CONSIDERED EXPOSURE C. | | | | 2)SHUTTER PERMIT APPLICATIONS REQUIRE A KEY PLAN, | | SHUTTER SCHEDULE CLEARLY MARKED WITH THE INFORMATION | | SPECIFIC TO THE SITE (TYPE OF CONSTRUCTION, MOUNTING | | CONNECTION TYPE, ANCHOR TYPE, ETC.) PLEASE SEE THE | | ATTACHED UPDATED SCHEDULE AND THE DRAWINGS THAT ARE | | PART OF THE PRODUCT APPROVALS TO CORRESPOND WITH THE | | SCHEDULE. ****** PLEASE SEE THAT THE DRAWINGS HAVE MANY | | ITEMS NOT ON SCHEDULE CIRCLED, INCREASES FOR EXPOSURE C | | WILL NOT REACH SPANS REQUIRED,CONNECTION TYPES CHOSEN | | DO NOT MATCH ANCHOR SPACING AND TAPCONS, EDGE DISTANCE | | CIRCLED DO NOT MATCH SCHEDULE. ******* | | | | 3)A RECORDED COPY OF THE NOTICE OF | | COMMENCEMENT IS REQUIRED PRIOR TO | | A PERMIT BEING ISSUED | | | | 4)PROVIDE PROOF OF OWNERSHIP OWNER STATUS IN SYSTEM | | DIFFERS FROM PAPA | | | | BLDG PLAN REVIEW | | ADRIAN MORSE | | 561-805-6716 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2007-05-22 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-05-22 |
Time |
15:58 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-05-22 |
Time |
15:58 |
Sent To |
B |
|
Notes |
2007-05-22 15:59:30 | TO "AMORSE" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2007-05-12 |
Time |
|
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-04-25 |
Time |
09:22 |
Sent To |
|
|
Notes |
2007-04-25 09:22:22 | TO "MISC" BOX#1 |
|
|
|
Account Summary | Usage Policy | Privacy Policy