Plan Review Stops For Permit 07040753 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2007-08-01 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2007-08-01 |
Time |
17:50 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2007-08-01 |
Time |
17:24 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2007-06-21 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2007-06-21 |
Time |
08:52 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2007-06-21 |
Time |
07:27 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2007-05-08 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2007-05-08 |
Time |
08:16 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2007-05-07 |
Time |
14:21 |
Sent To |
|
|
Notes |
2007-05-07 15:57:50 | BUILDING PLAN REVIEW | | PERMIT: 07040753 | | ADD: 1720 CENTREPARK DR. E | | CONT: THE WEITZ CO, LLC. | | TEL: (561)686-5511 | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | W/ 2006 FBC REVISIONS | | * WEST PALM BEACH AMENDMENTS | | | | REVIEW: 1ST | | ACTION: DENIED | | | | 1)--- VERY IMPORTANT STATEMENT --- | | PLEASE DO NOT IGNORE! | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | THE REVISION & REMOVE & REPLACE ANY | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | BER, WITH A DESCRIPTION OF THE REVISION | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | 2)110.2* W. P. B. ADMINISTRATIVE | | CODE, INFORMATION THAT IS REQUIRED FOR | | RECORD KEEPING & FOR CERTIFICATE OF | | OCCUPANCY: | | A) THE EDITION OFTHE CODE UNDER WHICH | | THE PROJECT WAS DESIGNED. | | B) THE USE AND OCCUPANCY, IN ACCORDANCE | | WITH THE PROVISIONS OF CHAPTER 3. | | C) THE DESIGN OCCUPANT LOAD, SEE 1004. | | E) IF AN AUTOMATIC SPRINKLER SYSTEM IS | | PROVIDED, WHETHER THE SPRINKLER SYSTEM | | IS REQUIRED. | | ) NUMBER OF FLOORS | | ) NUMBER OF ROOMS | | ) SQ. FT. FOOTPRINT | | ) SQ. FT. UNDER ROOF (TOTAL) | | ) OCCUPANT LOAD | | | | 3)FL S S 713.13 | | NOTICE OF COMMENCEMENT, TO BE FILED WITH THE CLERK OF | | THE COURT. | | NOTE: 713.13(2) | | IF THE WORK DESCRIBED IN THE NOTICE OFCOMMENCEMENT IS | | NOT ACTUALLYCOMMENCED WITHIN 90 DAYS AFTER THE | | RECORDING THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: | | 713.13(6)THE POSTING OF THE NOTICE OF COMMENCEMENT AT | | THE CONSTRUCTION SITE BEFORE THE FIRST INSPECTION. | | | | 4)THE DOOR ELEVATION ON SHEET A2.01 SHOWS A 3' X 7' | | DOOR, HOWEVER THE FLOOR PLAN SHOWS 3' X 8' DOORS. | | CLARIFY. | | | | 5)WHERE IS THE FOURTH 8'-8" PARTITION WALL LOCATED? | | THERE ARE THREE SECTIONS SHOWN ON THE PLANS, INDICATE | | WHERE THE OTHER WALL IS. | | | | 6)THE TITLE BLOCK IS MISSING THE PRINTED NAME AND | | LICENSE NUMBER OF THE ARCHITECT OF RECORD. THE DATE ON | | THE SEAL IS NOT LEGIBLE. SEE F.A.C.61G1-16.004. | | | | 7)IF THERE IS A SOFFIT AT THE PERIMETER OF THE | | ACOUSTICAL TILE CEILING IN THE OPEN WORKSTATION AREA, | | PROVIDE THE WALL DETAIL FOR THAT SOFFIT. ALSO PROVIDE | | SOME ELEVATION DETAILS OF THE PROJECT. CONSTRUCTION | | DOCUMENTS SHALL BE OF SUFFICIENT CLARITY TO INDICATE | | THE LOCATION, NATURE AND EXTENT OF THE WORK PROPOSED. | | FBC. 106.1.1.(SEE ALSO SEC. 106.3.5). | | | | MYRON JACOBS | | BUILDING PLAN REVIEWER | | 805-6726 | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
5 |
Status |
P |
Date |
2007-08-24 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2007-08-24 |
Time |
07:40 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2007-08-24 |
Time |
07:26 |
Sent To |
PC |
|
Notes |
2007-08-24 07:40:56 | STAMPED PLANS. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
F |
Date |
2007-08-22 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2007-08-22 |
Time |
17:29 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2007-08-22 |
Time |
17:25 |
Sent To |
PC |
|
Notes |
2007-08-22 17:29:34 | *** DENIED 4TH REVIEW *** | | | | | | 1) NOTE: PLEASE SEE THE TWO SETS NEED TO BE COMPLETE | | WITH ORIGINAL SIGNED, DATED AND SEALED PLANS. | | PLEASE SEE SHEET E1.02 IN ONE SET IS MISSING THE RAISED | | SEAL. | | PLEASE SEE SHEET E1.04 ON THE 2ND SET IS A PHOTO-COPY | | OF SIGNED AND SEALED PLANS. | | ** ALL MUST BE ORIGINAL, RAISED SEAL AND DATED PER FS | | 481.221. | | | | ** CALLED MR. RICHARD WATSON OF THE WEITZ COMPANY TO | | HAVE NEW SHEETS BROUGHT IN FOR STAMPING. | | | | 2) NOTE: PLEASE KNOW AS OF THIS REVIEW THE FEE ASSESSED | | PER THE FS 553.80(2)(B) STILL REMAINS AND IS A BALANCE | | OF $1800.00 | | | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW II | | CONSTRUCTION SERVICES DEPARTMENT | | CITY OF WEST PALM BEACH | | 561-805-6717 | | [email protected] | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
F |
Date |
2007-07-27 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2007-07-27 |
Time |
13:10 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2007-07-27 |
Time |
12:37 |
Sent To |
|
|
Notes |
2007-07-27 13:11:00 | *** UNSAT3RD REVIEW *** | | | | ** PLEASE SEE SOME COMMENTS FROM PREVIOUS REVIEW STILL | | REMAIN. | | | | 1) NOTE: PLEASE SEE AS REQUESTED ON THE PREVIOUS | | REVIEW, PLEASE COMPLY WITH FBC CHAPTER 13 FOR LIGHTING | | CONTROLS.ALL NEW BEING INSTALLED NEEDS TO COMPLY. | | THIS TENANT SPACE IS NOT DEFINED AS A BUILDING AND THIS | | SPACE IS LOCATED IN A BUILDING GREATER THAN 5K SQ FT. | | THE RESPONSE MENTIONS THIS IS 2400 + SQ FT AND DOES NOT | | NEED LIGHTING CONTROLS. THIS IS NOT THE CASE.PLEASE | | SEE THE DEFINITIONS OF A BUILDING IN BOTH CHAPTER 13 | | AND FBC DEFINITIONS. TENANT OCCUPANCIES LOCATED IN A | | BUILDING OVER 5K SQ FT EVEN IF 200 SQ FT FOR EXAMPLE | | FOR THE INDIVIDUAL TENANT SPACE STILL REQUIRES LIGHTING | | CONTROLS FOR AUTOMATED SHUTTING OFF/TURNING OFF OF | | LIGHTS. | | THIS HAS BEEN CONFIRMED WITH THE STATE ON MANY | | OCCASIONS AND THE STATE TAC COMMITTEE WHEN THE CODE | | CHANGE WAS MADE ALMOST TWO EARS AGO. | | PLEASE SEE THE ENERGY CALCULATIONS CAN NOT BE CONFIRMED | | AND DO NOT CORRELATE FOR LIGHTING CONTROLS AND PLANS. | | 13-415.1.ABC.1.1, .1.2, 13-415.1.A, 13-415.2 | | 13-101. | | | | 2) NOTE: PLEASE SEE THE PREVIOUS REVIEW REQUESTED THE | | ADDRESS OF THE UNIT OR SUITE NUMBER TO BE ADDED TO THE | | PLANS, HOWEVER THE RESPONSE MENTIONS THIS ENTIRE | | BUILDING IS ONE TENANT. | | PLEASE SEE THE ENERGY CALCULATIONS WHICH WERE SUBMITTED | | BY THE ARCHITECT STATES A UNIT/SUITE OF #118? | | PLEASE CLARIFY HOW THIS IS POSSIBLE. | | | | 3) NOTE: PLEASE SEE THE PREVIOUS REVIEW NOTES GAVE | | NOTICE TO FS 553.80(2)(B) WITH RESPECT TO REPEAT | | COMMENTS FOR CODE COMPLIANCE. | | PLEASE SEE A FEE HAS NOW BEEN ASSESSED TO THE DESIGN | | PROFESSIONAL AS REQUIRED PER THE ABOVE FLORIDA STATUTE. | | THIS FEE OF $1800.00 IS DUE BEFORE PLANS CAN BE | | RESUBMITTED. | | ONE COPY OF ELECTRICAL PLANS ALONG WITH ONE COPY OF | | ENERGY CALCULATIONS ARE BEING RETAINED BY THIS OFFICE. | | TO DATE NO ONE HAS CONTACTED THIS REVIEWER TO GO OVER | | ANY OF THE COMMENTS. | | | | * ** IMPORTANT** | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | PICKED UP FOR CORRECTIONS, PLEASE BE | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | SHEETS AND ONLY INSERT NEW REVISED | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | AND STAMPING. DO NOT LEAVE ANY | | OLD/VOIDED SHEETS IN SETS. | | PLEASE KNOW ONLY ONE SET OF THE | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | FOR REFERENCE. | | THIS WILL HELP IN THE REVIEW PROCESS AND | | AVOID ANY DELAYS. | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | REVIEWER. | | | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW II | | CONSTRUCTION SERVICES DEPT. | | CITY OF WEST PALM BEACH | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2007-06-18 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2007-06-18 |
Time |
11:15 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2007-06-18 |
Time |
09:05 |
Sent To |
|
|
Notes |
2007-06-18 11:16:08 | | | | | *** UNSAT 2ND REVIEW *** | | | | ** PLEASE SEE SOME COMMENTS FROM THE PREVIOUS ARE STILL | | IN NEED OF ADDRESSING. | | ** PLEASE KNOW AS NOT ALL INFORMATION NEEDED WAS | | SUBMITTED FOR A CODE COMPLIANT REVIEW THERE MAY BE NEW | | COMMENTS ON RE-SUBMITTAL OF PLANS. | | | | 1) NOTE: PLEASE SEE COMPLIANCE WITH CHAPTER 13 OF THE | | FBC HAS NOT BEEN ADDRESSED. THE REQUIRED LIGHTING | | CONTROLS AS PREVIOUSLY NOTED HAVE NOT BEEN PLACED ON | | PLANS. PLEASE SEE THE ENERGY CALCULATIONS SUBMITTED ARE | | NOT CORRECT. THE FIXTURES DO NOT CORRELATE, THE TYPES, | | THE CONTROLS ETC. | | PLEASE SEE ALL OF CHAPTER AND THE SECTIONS AS | | PREVIOUSLY GIVEN. | | 13-415.1.ABC.1.1, .1.2, .1.3, 13-415.1.AB.1.1, | | 13-415.2, 13-415.2.ABC.1.2 | | | | 2) NOTE: PLEASE SEE NOTE #3 FROM PREVIOUS REVIEW WHICH | | STATED THE MISSING REQUIRED INFORMATION ON TITLE BLOCKS | | PER 61G1-16.004. (STILL MISSING THE PRINTED LICENSE | | NUMBER OF THE ARCHITECT). | | | | 3) NOTE: PLEASE SEE THE CIRCUITING MAY NOT ONLY USE | | LIGHTING, RECEPTACLES ETC. THESE NEED TO BE SPECIFIC TO | | ROOMS, AREAS, OR OTHER TYPE OF DESIGNATION. MAY USE A | | NUMERICAL DESIGNATION TO OFFICES OR OTHER LOCATIONS. | | PLEASE SEE 408.4 | | | | 4) NOTE: PLEASE SEE ADDRESS ONLY INDICATES THE | | LOCATION. THIS BUILDING CONTAINS MORE THAN ONE | | SUITE/UNIT NUMBER? IF SO PLEASE SEE THE PERMIT | | APPLICATION NEEDS TO STATE THE SUITE/UNIT ALONG WITH | | THE PLANS. | | | | 5) NOTE: PLEASE SEE MISPRINT FOR NEW PANEL L1C, WHICH | | IS SHOWN AS LC1 ON PANEL AND L1C ON RISER. | | FBC 106.1.2 | | | | 6) NOTE: PLEASE SEE FS 553.802B WITH RESPECT TO REPEAT | | COMMENTS FOR CODE COMPLIANCE. THIS IS ONLY A NOTICE | | GIVEN AT THIS TIME. | | | | ** PLEASE SEE POSSIBLE COMMENTS FROM OTHER TRADES WHICH | | MAY AFFECT THE ELECTRICAL PLANS OR DESIGN OF PROJECT. | | | | ** IMPORTANT** | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | PICKED UP FOR CORRECTIONS, PLEASE BE | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | SHEETS AND ONLY INSERT NEW REVISED | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | AND STAMPING. DO NOT LEAVE ANY | | OLD/VOIDED SHEETS IN SETS. | | PLEASE KNOW ONLY ONE SET OF THE | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | FOR REFERENCE. | | THIS WILL HELP IN THE REVIEW PROCESS AND | | AVOID ANY DELAYS. | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | REVIEWER. | | | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW II | | CONSTRUCTION SERVICES DEPT. | | CITY OF WEST PALM BEACH | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2007-04-30 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2007-04-30 |
Time |
15:21 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2007-04-30 |
Time |
13:18 |
Sent To |
|
|
Notes |
2007-04-30 15:21:42 | ** UNSAT ** | | | | ** PLEASE SEE THAT ANY REFERENCES TO THE FBC CHAPTER 1 | | ARE FROM THE ADMINISTRATIVE CODE ADOPTED BY THE CITY OF | | WEST PALM BEACH. | | | | | | 1) NOTE:PLEASE KNOW THAT ANY PERMIT APPLICATIONS | | WHICH ARE SUBMITTED AFTER DECEMBER 8TH, 2006 PLACES | | PROJECTS UNDER THE NEW CODES ADOPTED BY THE STATE. | | PLEASE SEE THAT THIS SHALL INCLUDE 2006 REVISIONS TO | | THE 2004 FBC FOR ALL TRADES AND THE 2005 NFPA-70. | | PLEASE KNOW THERE ARE CHANGES IN THE FBC WHICH MAY | | AFFECT DESIGNS FOR ALL TRADES. | | PLEASE LIST THE FOLLOWING ON ELECTRICAL SHEETS FOR THIS | | REVIEWER AT A MINIMUM. | | 2004 FBC W/ 2006 REVISIONS | | 2005 NFPA-70 | | | | 2) NOTE: PLEASE SEE 2004 FBC CHAPTER 13 W/ 2006 | | REVISIONS. | | PLEASE SEE MISSING LIGHTING CONTROLS PER | | 13-415.1.ABC.1.1, .1.2. A LIGHTING CONTACTOR IS | | INDICATED, HOWEVER NO TIMES SCHEDULING, NO TIME OVER | | RIDES, ETC ARE SHOWN. | | PLEASE SEE THE WRONG EDITION OF THE FLORIDA ENERGY CODE | | IS SHOWN AND CALCULATED. | | PLEASE CORRELATE THE LIGHTING AS SHOWN ON PLANS WITH | | THAT OF THE FIXTURES, WATTAGES ETC AS SHOWN ON | | CALCULATIONS. | | PLEASE SEE THE CONTROL FOR LIGHTING NEEDS TO COORDINATE | | WITH THE METHOD ON PLANS. | | PLEASE SEE 13-415.ABC.1.2 | | PLEASE BE SURE THAT ANY OVER RIDE DEVICES ARE SHOWN ON | | PLANS AND SYMBOL LEGEND. | | PLEASE BE SURE THE ENERGY CALCULATIONS ARE SIGNED AND | | SEALED. THEY ARE ONLY SIGNED AS SUBMITTED. | | 13-103.1.1.1 | | | | 3) NOTE: PLEASE SEE MISSING INFORMATION ON TITLE BLOCKS | | AS REQUIRED PER FAC 61G1-16.004. | | PLEASE SEE THE MISSING PRINTED NAME AND PRINTED LICENSE | | NUMBER FOR THE ARCHITECT OF RECORD. | | | | 4) NOTE: PLEASE SEE 408.4 WHICH REQUIRE THE CIRCUITING | | TO BE SPECIFIC TO THE ROOMS AND AREAS IN WHICH THEY | | FEED. | | PLEASE KNOW THESE CAN BE DONE BY THE ROOM NAME OR | | NUMERICAL DESIGNATION. | | PLEASE SEE THE FOLLOWING TEXT WHICH IS TAKEN FROM THE | | CODE. | | | | *SECTION 408.4 WAS REVISED FOR THE 2005 CODE TO REQUIRE | | THAT THE IDENTIFICATION FOR EVERY CIRCUIT SUPPLIED BY A | | PANEL-BOARD OR SWITCHBOARD BE LEGIBLE AND CLEARLY STATE | | THE SPECIFIC PURPOSE FOR WHICH THE CIRCUIT IS USED. | | CIRCUITS USED FOR THE SAME PURPOSE MUST BE IDENTIFIED | | AS TO THEIR LOCATION. FOR EXAMPLE, SMALL APPLIANCE | | BRANCH CIRCUITS CAN SUPPLY OUTLETS IN THE KITCHEN, | | DINING ROOM, AND KITCHEN COUNTERTOPS. IDENTIFYING THE | | CIRCUITS AS SMALL APPLIANCE BRANCH CIRCUITS IS NOT | | ACCEPTABLE; INSTEAD, THEY SHOULD BE IDENTIFIED AS | | ``KITCHEN WALL RECEPTACLES,'' ``DINING ROOM FLOOR | | RECEPTACLE,'' OR ``KITCHEN COUNTERTOP RECEPTACLES LEFT | | OF SINK.'' CIRCUIT DIRECTORIES CONTAINING MULTIPLE | | ENTRIES WITH ONLY ``LIGHTS'' OR ``OUTLETS'' DO NOT | | PROVIDE THE SUFFICIENT DETAIL REQUIRED BY THIS | | SECTION.* | | 408.4, 310.16, 240.4 ETC | | FBC 106.3.5.4 | | | | 5) NOTE: PLEASE INCLUDE THE ADDRESS OF THE PROJECT ON | | TITLE BLOCKS. | | PLEASE SEE AS APPLIED IS 1720 E CENTREPARK DR. | | | | ** IMPORTANT** | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | PICKED UP FOR CORRECTIONS, PLEASE BE | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | SHEETS AND ONLY INSERT NEW REVISED | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | AND STAMPING. DO NOT LEAVE ANY | | OLD/VOIDED SHEETS IN SETS. | | PLEASE KNOW ONLY ONE SET OF THE | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | FOR REFERENCE. | | THIS WILL HELP IN THE REVIEW PROCESS AND | | AVOID ANY DELAYS. | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | REVIEWER. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW II | | CONSTRUCTION SERVICES DEPT. | | CITY OF WEST PALM BEACH | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2007-08-07 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2007-08-07 |
Time |
11:53 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2007-08-07 |
Time |
11:04 |
Sent To |
|
|
Notes |
2007-08-07 11:53:07 | *****APPROVED W/REMINDER***** | | | | | | ALL COMMENTS FROM THE PREVIOUS FIRE PLAN REVIEWS HAVE | | BEEN ADDRESSED;PLAN SHEETS A2.01, E1.01, AND FP 1.01 | | WERE STAMPED, INITIALED, AND DATED.SINCE1 OF THE 2 | | SUBMITTED PLAN SHEETSE1.02, E 1.03, AND E1.03 WERE | | RETAINED BY THE ELECTRICAL PLAN REVIEWER, FIRE STAMPING | | WILL BE REQUIRED FOR SHEET E1.02 AND E1.04. | | | | CAPT. MICHAEL A. WILLIAMS | | FIRE PLAN REVIEW |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
F |
Date |
2007-06-20 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2007-06-20 |
Time |
11:58 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2007-06-20 |
Time |
11:45 |
Sent To |
|
|
Notes |
2007-06-20 11:57:49 | *****UNSAT***** | | | | THE FOLLOWING COMMENTS FROM THE PREVIOUS FIRE PLAN | | REVIEW STILL NEED TO BE ADDRESSED: | | | | | | 3.STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR | | DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241.ADD | | TO THE APPROPIATE PLAN SHEET | | | | 4.COMBUSTIBLE WASTE MATERIALS, DUST, AND DEBRIS SHALL | | BE REMOVED FROM THE SITE DAILY OR MORE FREQUENTLY AS | | NECESSARY FOR SAFE OPERATION.ADD TO THE APPROPIATE | | PLAN SHEET | | | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | LETTER INDICATING HOW/WHERE EACH COMMENT WAS ADDRESSED | | | | | | CAPT. MICHAEL A. WILLIAMS | | FIRE PLAN REVIEW | | 561-805-6722 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2007-05-14 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2007-05-14 |
Time |
11:19 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2007-05-14 |
Time |
10:47 |
Sent To |
|
|
Notes |
2007-05-14 11:19:13 | *****DENIED***** | | | | | | 1.THE COMPLETE ADDRESS OF WHERE THE SCOPE OF WORK IS | | TO BE CONDUCTED SHALL BE IN THE TITLE BLOCK OF EACH | | SUBMITTED PLAN SHEET. | | | | 2.THE 2003 EDITION OF NFPA 101 - LIFE SAFETY CODE - | | SHALL BE REFERENCED. | | | | 3.STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR | | DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241. | | | | 4.COMBUSTIBLE WASTE MATERIALS, DUST, AND DEBRIS SHALL | | BE REMOVED FROM THE SITE DAILY OR MORE FREQUENTLY AS | | NECESSARY FOR SAFE OPERATION. | | | | 5.SPECIFY THE INTERIOR FINISH MATERIALS FOR WALLS AND | | CEILINGS AS CLASS A, CLASS B, OR CLASS C. | | | | 6.ON DRAWING E1.04,AMEND FIRE ALARM SYSTEM NOTE #17 | | TO INDICATE THAT DUCT SMOKE DETECTORS SHALL INITIATE A | | GENERAL FIRE ALARM. | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | LETTER INDICATING HOW/WHERE EACH COMMENT WAS ADDRESSED | | | | | | CAPT. MICHAEL A. WILLIAMS | | FIRE PLAN REVIEW | | 561-805-6722 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2007-11-29 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-11-29 |
Time |
16:44 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-11-29 |
Time |
16:44 |
Sent To |
M |
|
Notes |
2007-11-29 16:44:44 | TO "M" BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2007-10-17 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-10-17 |
Time |
11:50 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-10-17 |
Time |
11:50 |
Sent To |
M |
|
Notes |
2007-10-17 11:51:05 | TO "M" BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2007-08-16 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-08-16 |
Time |
16:05 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-08-16 |
Time |
16:05 |
Sent To |
E |
|
Notes |
2007-08-16 16:05:21 | TO "DPALMER" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2007-07-18 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-07-18 |
Time |
10:17 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-07-18 |
Time |
10:17 |
Sent To |
|
|
Notes |
2007-07-26 14:29:03 | TO "BOB"#10 | 2007-07-18 10:18:02 | WAITING FOR "BOB" |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2007-06-13 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-06-13 |
Time |
09:42 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-06-13 |
Time |
09:42 |
Sent To |
|
|
Notes |
2007-06-14 14:27:15 | TO "BOB"#5 | 2007-06-13 09:42:47 | WAITING FOR "BOB" |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2007-05-14 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2007-05-14 |
Time |
10:47 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2007-04-23 |
Time |
15:09 |
Sent To |
|
|
Notes |
2007-04-23 15:10:59 | TO "BOB"#16 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
P |
Date |
2007-12-04 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2007-12-04 |
Time |
11:57 |
Rev Time |
0.25 |
Received By |
tgordon |
Date |
2007-12-04 |
Time |
11:56 |
Sent To |
|
|
Notes |
2007-12-04 11:57:43 | REVISION TO MECH. PLAN PAGE M1.01. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2007-10-22 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2007-10-22 |
Time |
10:18 |
Rev Time |
0.25 |
Received By |
tgordon |
Date |
2007-10-22 |
Time |
10:18 |
Sent To |
|
|
Notes |
2007-10-22 10:19:38 | REVISION TO MECH. PLANS PAGE M1.01. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2007-06-15 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2007-06-15 |
Time |
11:14 |
Rev Time |
0.45 |
Received By |
tgordon |
Date |
2007-06-15 |
Time |
11:14 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2007-04-25 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2007-04-25 |
Time |
14:03 |
Rev Time |
0.45 |
Received By |
tgordon |
Date |
2007-04-25 |
Time |
14:03 |
Sent To |
|
|
Notes |
2007-04-25 14:34:18 | *** DENIED *** | | 1) ENERGY CALCULATIONS ARE CALLING FOR A 92,000 BTU A/C | | SYSTEM, MECHANICAL PLANS ARE CALLING FOR A 30,000 BTU | | A/C SYSTEM, THE TWO MUST COINCIDE, PLEASE CORRECT. | | | | 2) COOLING LOAD CALCULATIONS ARE CALLING FOR 76,810 | | TOTAL BTU'S, MECHANICAL PLANS ARE CALLING FOR 30,000 | | TOTAL BTU'S. SEE 2004 FBC 13--407.1.ABC.1.1, PLEASE | | CORRECT. | | | | 3) PLEASE SHOW OUTDOOR AIR CALCULATIONS ON MECHANICAL | | PLANS, SEE 2004 FBC/M 403.3. | | | | 4) ENERGY CALCULATIONS NEED TO BE SIGNED BY OWNER/AGENT | | ALSO, PER 2004 FBC 13-400.3.ABC.2. | | | | 5) COULD NOT FIND THE A/C SYSTEM IN THE EQUIPMENT SPEC. | | LISTED ON THE ARI DIRECTORY WEB SITE. PLEASE SUBMIT | | DETAILED MANUFACTURER'S SPECIFICATION'S AND | | INSTALLATION INSTRUCTIONS FOR A/C SYSTEM BEING | | INSTALLED.. | | | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
N |
Date |
2007-07-30 |
|
|
Cont ID |
|
Sent By |
choops |
Date |
2007-07-30 |
Time |
17:33 |
Rev Time |
0.00 |
Received By |
choops |
Date |
2007-07-30 |
Time |
17:33 |
Sent To |
PC |
|
Notes |
2007-07-30 17:34:24 | *VALUE OF PROPOSED WORK DOES NOT EXCEED 50% OF THE | | IMPROVEMENT VALUE. |
|
|