Plan Review Details - Permit 07040598
Plan Review Stops For Permit 07040598
Review Stop B BUILDING (STRUCTURAL)
Rev No 6 Status P Date 2008-09-26 Cont ID  
Sent By kconrad Date 2008-09-25 Time 08:10 Rev Time 0.00
Received By kconrad Date 2008-09-25 Time 08:10 Sent To  
Notes
2008-09-26 08:09:56REVIEWED SHEET A-3 FOR CLARIFICATION NOTES/DETAILS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2008-05-21 Cont ID  
Sent By lmartine Date 2008-05-21 Time 15:55 Rev Time 0.00
Received By lmartine Date 2008-05-21 Time 15:55 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status F Date 2008-02-01 Cont ID  
Sent By amorse Date 2008-02-01 Time 17:29 Rev Time 0.00
Received By amorse Date 2008-02-01 Time 17:29 Sent To PC
Notes
2008-02-01 17:34:48 
  
 DENIED
  
 1)APPLICATION APPEARS TO BE CODE COMPLIANT BUT THE
 FOLLOWING REQUIREMENTS ARE TO BE MET PRIOR TO FINAL
 DATE STAMPING OF DRAWINGS AND ISSUE OF PERMIT.
  
 IMPACT FEES MUST BE PAID TO PALM BEACH COUNTY. THE
 ACTUAL PERMIT SETS OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT ATTACHED TO THE
 PERMIT APPLICATION. PLEASE CALL (561) 233-5025 FOR MORE
 INFORMATION.
  
 SUBMIT A COPY OF THE RECORDED NOTICE OF COMMENCEMENT TO
 THE CONSTRUCTION SERVICES DEPARTMENT
  
 BLDG PLAN REVIEW
 ADRIAN MORSE
 561-805-6716

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2007-11-21 Cont ID  
Sent By amorse Date 2007-11-21 Time 14:13 Rev Time 0.00
Received By amorse Date 2007-11-21 Time 14:12 Sent To PC
Notes
2007-11-21 14:36:15 
  
  
 DENIED
  
 THE FOLLOWING COMMENTS WERE NOT ADDRESSED FROM THE
 FIRST OR SECOND REVIEW:
  
 1ST REVIEW
  
 3)BEFORE A PERMIT TO CONSTRUCT, MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SETS OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561) 233-5025 FOR MOREINFORMATION.
 ******* IMPACT FEE STAMP REQUIRED EVEN IF ZERO FEES
 DUE*******
  
 5)THOSE PRODUCTS WHICH ARE REGULATED BY DCA RULE
 9B-72 SHALL BE REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR
 JURISDICTIONAL APPROVAL PER 106.3.3 FBC*
 ****NOT PERFORMED/ DESIGNER OF RECORD SHALL REVIEW AND
 APPROVE ALL SUBMITTALS *****
  
  
 2ND REVIEW
  
 2)PROVIDE PRODUCT APPROVALS FOR THE (2) SINGLE FRENCH
 DOORS ON THE FRONT OF BUILDING AND THE DOUBLE SET AT
 THE REAR
 ********NO PRODUCT APPROVALS SUBMITTED********
  
 3)PROVIDE THE CORRECT FLORIDA STATEWIDE PRODUCT
 APPROVAL COVERS AND MIAMI-DADE NOA (03-0605.05) THAT
 VALIDATES THE CASTCRETE LINTELS
 ********PRODUCT APPROVALS NOT CORRECTED********
  
 4)A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT IS REQUIRED PRIOR TO
 A PERMIT BEING ISSUED
  
 NOTE: FBC = FLORIDA BUILDING CODE 2004
 FBC* = WEST PALM BEACH ADMINISTRATIVE
 AMENDMENTS TO FBC
 FAC = FLORIDA ADMINISTRATIVE CODE
 FS = FLORIDA STATUTES
 FBC RES. = FLORIDA BUILDING CODE
 RESIDENTIAL 2004 C/W 2006 AMENDMENTS
  
 BLDG PLAN REVIEW
 ADRIAN MORSE
 561-805-6716
  
  
  
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2007-08-11 Cont ID  
Sent By amorse Date 2007-08-11 Time 06:47 Rev Time 0.00
Received By amorse Date 2007-08-11 Time 06:47 Sent To PC
Notes
2007-08-11 07:27:19 
  
  
 DENIED
  
 THE FOLLOWING COMMENTS WERE NOT ADDRESSED FROM THE
 FIRST REVIEW:
  
 2)THE CLAIMED VALUATION ON THE PERMIT APPLICATION IS
 LOW. FOR PERMITTING PURPOSES, VALUATION OF BUILDINGS
 AND SYSTEMS SHALL BE THE TOTAL REPLACEMENT COST
 EXCLUDING LAND VALUE. OUR VALUATION REFERENCE IS ICC
 (BVD), MARSHALL-SWIFT AND MEANS COST ANALYSIS SERVICES
 PER 108.3 FBC*.DUE TO INCREASED VALUE, RADON FEES AND
 NSF RETURNED CHECK ******$ 585.62 SHALL BE PAID BEFORE
 FURTHER REVIEW.*******
 ****NOT PERFORMED*****
  
 3)BEFORE A PERMIT TO CONSTRUCT, MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SETS OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561) 233-5025 FOR MOREINFORMATION.
 ****NOT PERFORMED*****
  
 5)THOSE PRODUCTS WHICH ARE REGULATED BY DCA RULE
 9B-72 SHALL BE REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR
 JURISDICTIONAL APPROVAL PER 106.3.3 FBC*
 ****NOT PERFORMED*****
  
 6)SUBMIT 2 COPIES OF ENGINEERED TRUSS DRAWINGS THAT
 COMPLY WITH R802.10.1 FBC WITH PERMIT APPLICATION OR
 BEFORE INSTALLATION THAT HAVE BEEN REVIEWED AND
 APPROVED BY THE DESIGNER OF RECORD
 ****NOTE THESE SETS ARE NOT THE ENGINEERED SIGNED AND
 SEALED SET BUT THIS WILL NOT HOLD UP ISSUANCE OF PERMIT
 AS THEY CAN BE GIVEN TO INSPECTOR ON SITE*****
  
 8)SUBMIT ENERGY CALC'S PER 13-101.2.2
 FBC. BE SURE THAT THEY ARE SIGNED AND
 DATED BY PREPARER AND OWNER/AGENT PRIOR
 TO SUBMITTAL
 ****ONLY ONE SET WAS SUBMITTED******
  
 NEW COMMENTS
  
 1)IN AN EXISTING BUILDING WHERE ALTERATIONS ARE BEING
 MADE A DESIGN PROFESSIONAL MUST ELECT THE LEVEL OF
 ALTERATION PER 301.5 OF EXISTING BUILDING CODE AND
 STATE ALONG WITH THE TYPE OF CONSTRUCTION ON THE
 DRAWINGS. )PLANS AND SPECIFICATIONS DESIGN PARAMETERS
 SHALL COMPLY WITH THE 2004 FLORIDA BLDG CODE WITH 2006
 AMENDMENTS PER 106.1.1 FBC*
  
 2)PROVIDE PRODUCT APPROVALS FOR THE (2) SINGLE FRENCH
 DOORS ON THE FRONT OF BUILDING AND THE DOUBLE SET AT
 THE REAR
  
 3)PROVIDE THE CORRECT FLORIDA STATEWIDE PRODUCT
 APPROVAL COVERS AND MIAMI-DADE NOA (03-0605.05) THAT
 VALIDATES THE CASTCRETE LINTELS
  
 4)A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT IS REQUIRED PRIOR TO
 A PERMIT BEING ISSUED
  
 NOTE: FBC = FLORIDA BUILDING CODE 2004
 FBC* = WEST PALM BEACH ADMINISTRATIVE
 AMENDMENTS TO FBC
 FAC = FLORIDA ADMINISTRATIVE CODE
 FS = FLORIDA STATUTES
 FBC RES. = FLORIDA BUILDING CODE
 RESIDENTIAL 2004 C/W 2006 AMENDMENTS
  
 BLDG PLAN REVIEW
 ADRIAN MORSE
 561-805-6716
  
  
  
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-06-09 Cont ID  
Sent By amorse Date 2007-06-09 Time 14:31 Rev Time 0.00
Received By amorse Date 2007-06-09 Time 14:31 Sent To PC
Notes
2007-06-09 15:11:43 
  
 DENIED
  
 1)THE STATE OF FLORIDA REQUIRES COLLECTION OF A RADON
 SURCHARGE ON ALL NEW CONSTRUCTION COMPUTED ON UNDER
 ROOF FLOOR SPACE PER 10D-91 FAC. THESE FEES WILL BE
 ADDED TO THE PERMIT APPLICATION FEES
  
 2)THE CLAIMED VALUATION ON THE PERMIT APPLICATION IS
 LOW. FOR PERMITTING PURPOSES, VALUATION OF BUILDINGS
 AND SYSTEMS SHALL BE THE TOTAL REPLACEMENT COST
 EXCLUDING LAND VALUE. OUR VALUATION REFERENCE IS ICC
 (BVD), MARSHALL-SWIFT AND MEANS COST ANALYSIS SERVICES
 PER 108.3 FBC*.DUE TO INCREASED VALUE RADON FEES AND
 NSF RETURNED CHECK $ 585.62 SHALL BE PAID BEFORE
 FURTHER REVIEW.
  
 3)BEFORE A PERMIT TO CONSTRUCT, MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SETS OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561) 233-5025 FOR MOREINFORMATION.
  
 4)THE PERMIT APPLICATION SHALL INCLUDE TWO COPIES OF
 EACH PRODUCT APPROVAL THAT
 IS RELEVANT PER 9B-72. THESE SHOULD INCLUDE THE FLORIDA
 STATE APPROVAL COVER PAGES, AND THE PRODUCT NOA THAT
 LISTS THE SYSTEM COMPONENTS/ FASTENER LIST PAGES, THE
 PAGES WITH THE CHOSEN ASSEMBLY/ SYSTEM TO BE USED AND
 THE GENERAL LIMITATIONS PAGE. ALL CAN BE FOUND ON
 WWW.FLORIDABUILDING.ORG
  
 5)THOSE PRODUCTS WHICH ARE REGULATED BY DCA RULE
 9B-72 SHALL BE REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR
 JURISDICTIONAL APPROVAL PER 106.3.3 FBC*
  
 6)SUBMIT 2 COPIES OF ENGINEERED TRUSS DRAWINGS THAT
 COMPLY WITH R802.10.1 FBC WITH PERMIT APPLICATION OR
 BEFORE INSTALLATION THAT HAVE BEEN REVIEWED AND
 APPROVED BY THE DESIGNER OF RECORD
  
 7)CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT
 CLARITY TO INDICATE THE LOCATION,NATURE, AND EXTENT OF
 THE WORK PROPOSED AND SHOW IN DETAIL THAT IT WILL
 CONFORM TO THE PROVISIONS OF THIS CODE PER 106.1.1
 FBC*. PLEASE NOTE THAT PAGE 4 OF 4 IS ILLEGIBLE.
  
 8)SUBMIT ENERGY CALC'S PER 13-101.2.2
 FBC. BE SURE THAT THEY ARE SIGNED AND
 DATED BY PREPARER AND OWNER/AGENT PRIOR
 TO SUBMITTAL
  
 9)PROVIDE EXISTING LAYOUT OF BUILDING, SHOW ALL WALLS
 TO BE DEMOLISHED AND WHICH WALLS WILL BE REBUILT ON NEW
 FLOOR PLAN. SHOW ALL CHANGES IN CONFIGURATION IF ANY.
  
 10)WALL SECTION OF FAMILY ROOM ON PAGE 4/4 SHOWS 2X6
 WALL WHICH WOULD REQUIRE R19 INSULATION, ALSO PROVIDE
 CEILING INSULATION VALUE TO MATCH ENERGY CALC'S.
  
 11)FOUNDATION MEASUREMENTS ON TYPICAL WALL SECTION
 PAGE 4/4 DO NOT BALANCE. 16" FOUNDATION WITH 12" BELOW
 GRADE AND 6" ABOVE = 18"
  
 12)PROVIDE TRUSS ANCHORS WITH FL STATE APPROVAL #'S
 ON THE SCHEDULE PAGE 3/4OR SUBMIT PRODUCT APPROVAL
 SHEETS.
  
 13)THE CITY OF WEST PALM BEACH REQUIRES THE FLORIDA
 STATE PRODUCT APPROVAL COVER
 SHEETS WHEN AVAILABLE. THEY CAN BE SEARCHED FOR ON
 WWW.FLORIDABUILDING.ORG.WHEN AVAILABLE AND NOT
 SUBMITTED APPLICATIONS WILL BE DENIED
  
 14)THE FOLLOWING CORRECTIONS ARE REQUIRED FOR THE
 PRODUCT APPROVALS
 A)PROVIDE PRODUCT APPROVALS FOR ROOFING MATERIAL
 (SHINGLES, ETC.), NON GLAZED REAR DOOR
 B)TRACO WINDOWS STATE COVER SHEETS (FL# 6738) AND ODL
 DOORS (MASONITE STEEL DOOR WITH ODL HURRICANE GLAZING
 6'-8" FL# 2979)
  
 15)A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT IS REQUIRED PRIOR TO
 A PERMIT BEING ISSUED
  
 NOTE: FBC = FLORIDA BUILDING CODE 2004
 FBC* = WEST PALM BEACH ADMINISTRATIVE
 AMENDMENTS TO FBC
 FAC = FLORIDA ADMINISTRATIVE CODE
 FS = FLORIDA STATUTES
 FBC RES. = FLORIDA BUILDING CODE
 RESIDENTIAL 2004 C/W 2006 AMENDMENTS
  
 REMOVE ALL OLD PAGES AND RESUBMIT 2 COMPLETE SETS OF
 NEW DRAWINGS AND INCLUDE 1 COPY OF THE OLD PAGES ONLY
 FOR REFERENCE
  
  
 BLDG PLAN REVIEW
 ADRIAN MORSE
 561-805-6716
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2007-10-31 Cont ID  
Sent By btrobaug Date 2007-10-31 Time 07:31 Rev Time 0.00
Received By btrobaug Date 2007-10-31 Time 06:44 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2007-08-07 Cont ID  
Sent By btrobaug Date 2007-08-07 Time 11:44 Rev Time 0.00
Received By btrobaug Date 2007-08-07 Time 09:33 Sent To P
Notes
2007-08-07 11:43:59 
  
 THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES:
  
 THE 2004 FLORIDA BUILDING CODE, 2006 REVISIONS, 2004
 RESIDENTIAL BUILDING CODE, 2005 NEC, NFPA-72 2002, ,
 2004 FBC AS AMENDED, CHAPTER 1.
 AND FOUND NONE COMPLIANT WITH THE FOLLOWING: ALL
 COMMENTS ARE REGARDING SHEET 2 OF 4.
  
 1} THE ELECTRICAL RISER DIAGRAM DOES NOT INCLUDE A
 DISCONNECTING MEANS REQUIRED PER 230.70(A)(1) NEC "THE
 SERVICE DISCONNECTING MEANS SHALL BE INSTALLED AT A
 READILY ACCESSIBLE LOCATION EITHER OUTSIDE OF A
 BUILDING OR STRUCTURE OR INSIDE NEAREST THE POINT OF
 ENTRANCE OF THE SERVICE CONDUCTORS." THE SITE/FLOOR
 PLAN INCLUDES A DISCONNECT AT THE METER LOCATION.
 CORRELATE THE SERVICE EQUIPMENT .
  
 2} THE RISER STATES A 200 AMP SERVICE, THE PANEL IS
 LABLED 150 AMPS, AND THE GROUNDING ELECTRODE CONDUCTOR
 , #6 CU, IS SIZED FOR A150 AMP SERVICE PER 250.66 NEC.
 CORRELATE THE EQUIPMENT.
  
 3}PROVIDE A RISER DIAGRAM WITH CONDUCTOR AND CONDUIT
 SIZE AND TYPE, FOR ALL FEEDERS FROM THE WEATHERHEAD TO
 THE PANEL. 215.5 NEC
  
 4} CIRCUIT # 27 ON THE PANEL SCHEDULE LABLED "DINING
 ROOM REC" IS A 15 AMP CIRCUIT. PER 210.52(B)(1) THIS
 CIRCUIT MUST BE 20 AMP (#12 WIRE).
  
 5} THE RECEPTACLE LOCATION ON THE PENINSULAR MAY NOT
 MEET THE REQUIRWMENTS OF 210.52(C)(5) EXCEPTION, IF THE
 COUNTER EXTENDS MORE THAN 6", THE RECEPTACLE MAY NEED
 TO BE RELOCATED TO THE END AND PLACED WITHIN12" FROM
 THE TOP. SEE ARTICLE AND EXCEPTION.
  
 6} INDICATE A DISCONNECTING MEANS FOR THE WATER HEATER.
 SEE 422.16 NEC FOR CORD AND PLUG RESTRICTIONS, AND
 422.31(B) FOR HARDWIRE REQUIREMENTS.
  
 PLEASE REMOVE ALL OLD OR VOIDED SHEETS AND REPLACE WITH
 CORRECTED ONES WHEN RESUBMITTING. INCLUDE THEM
 SEPARATELY TO EXPEDITE THE REVIEW PROCESS. ANSWER
 REVIEW COMMENTS IN WRITING.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW.
 CITY OF WEST PALM BEACH
 561/805-6718
 [email protected]
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2007-05-18 Cont ID  
Sent By btrobaug Date 2007-05-18 Time 09:04 Rev Time 0.50
Received By btrobaug Date 2007-05-18 Time 08:33 Sent To M
Notes
2007-05-18 09:04:29 
  
  
 NONCOMPLIANT
  
 PLEASE MAKE THE FOLLOWING CORRECTIONS FOR CODE
 COMPLIANCE AND RESUBMIT FOR REVIEW.
  
 1} PLEASE LOCATE ALL SERVICE EQUIPMENT ON THE PLAN,
 METER ENCLOSURE, DISCONNECTS AND PANELS, SO THAT
 COMPLIANCE WITH ARTICLES 225 AND 230 CAN BE REVIEWED.
  
 2} GIVE PANEL SPECIFICATIONS, NUMBER OF SPACES, VOLTAGE
 AND AMPERE RATING, MAIN LUG OR MAIN BREAKER.
  
 3} PROVIDE A PANEL SCHEDULE PER 408.4. PLEASE SEE NEW
 VERBAGE FOR 2005 NEC: "THE IDENTIFICATION SHALL INCLUDE
 SUFFICIENT DETAIL TO ALLOW EACH CIRCUIT TO BE
 DISTINGUISHED FROM ALL OTHERS."
  
 4} PLEASE INDICATE THE CODE CYCLES THIS PROJECT WAS
 DESIGNED UNDER. 2004 FBC, 2005 NEC ETC. ADD TO NOTES
 FOR CLARITY IN THE FIELD.
  
 5} PLEASE INCLUDE THE ADDRESS OF THE PROJECT ON THE
 PLANS FOR RECORD RETENTION.106.1.3.FBC AS AMENDED.
  
 6} KITCHEN RECEPTACLE SPACING MUST COMPLY WITH
 210.52(A), 210.52(C). AND 210.8(A)(6) GFI. CHECK PLAN
 FOR SPACING REQUIREMENTS.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2008-01-28 Cont ID  
Sent By adarroug Date 2008-01-28 Time 10:01 Rev Time 0.00
Received By adarroug Date 2008-01-28 Time 10:01 Sent To Z
Notes
2008-01-28 10:01:29TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2007-10-26 Cont ID  
Sent By shill Date 2007-10-26 Time 13:36 Rev Time 0.00
Received By shill Date 2007-10-26 Time 13:36 Sent To Z
Notes
2007-10-26 13:38:07TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2007-08-02 Cont ID  
Sent By adarroug Date 2007-08-02 Time 15:16 Rev Time 0.00
Received By adarroug Date 2007-08-02 Time 15:16 Sent To Z
Notes
2007-08-02 15:16:43TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-05-09 Cont ID  
Sent By shill Date 2007-05-09 Time 16:41 Rev Time 0.00
Received By shill Date 2007-05-09 Time 16:41 Sent To E
Notes
2007-05-09 16:43:23TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2007-06-09 Time   Rev Time 0.00
Received By adarroug Date 2007-04-18 Time 13:36 Sent To  
Notes
2007-04-18 13:38:36TO "Z" BOX

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2007-05-18 Cont ID  
Sent By tgordon Date 2007-05-18 Time 15:45 Rev Time 0.20
Received By tgordon Date 2007-05-18 Time 15:45 Sent To P
Notes
2007-05-18 15:46:33NO MECHANICAL PLANS SUBMITTED, AND NO
 MECHANICAL PERMIT NUMBER APPLIED FOR AT
 THIS TIME.

Review Stop P PLUMBING
Rev No 3 Status P Date 2007-11-17 Cont ID  
Sent By jleech Date 2007-11-17 Time 13:28 Rev Time 0.00
Received By jleech Date 2007-11-17 Time 13:28 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2007-08-08 Cont ID  
Sent By jleech Date 2007-08-08 Time 07:12 Rev Time 0.00
Received By jleech Date 2007-08-08 Time 07:12 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2007-05-21 Cont ID  
Sent By jleech Date 2007-05-21 Time 07:34 Rev Time 0.00
Received By jleech Date 2007-05-21 Time 07:34 Sent To B
Notes
2007-05-21 07:38:38DENIED;
  
 NOT ENOUGH INFORMATION. PLEASE SHOW A SANITARY RISER
 DIAGRAM. SECTION 106.3.5.4(9).

Review Stop Z ZONING
Rev No 5 Status P Date 2008-07-02 Cont ID  
Sent By choops Date 2008-07-02 Time 16:40 Rev Time 0.00
Received By choops Date 2008-07-02 Time 16:40 Sent To PC
Notes
2008-07-02 16:41:42***APPROVED - SUBMITTAL OF FORMBOARD SURVEY***
  
 PROVISO: FRONT PORCH SHOWN IS A CONCRETE SLAB ONLY (IT
 DOES NOT MEET SETBACK REQUIREMENTS FOR A STRUCTURE).

Review Stop Z ZONING
Rev No 4 Status P Date 2008-01-28 Cont ID  
Sent By choops Date 2008-01-28 Time 15:08 Rev Time 0.00
Received By choops Date 2008-01-28 Time 15:08 Sent To B
Notes
2008-01-28 15:08:56***APPROVED - RESUB #3***
  
  
  
  
 SENT TO "B" - AM

Review Stop Z ZONING
Rev No 3 Status F Date 2007-10-29 Cont ID  
Sent By choops Date 2007-10-29 Time 16:39 Rev Time 0.00
Received By choops Date 2007-10-29 Time 16:39 Sent To E
Notes
2007-10-29 16:40:32***FAILED - RESUB #2***
  
  
 REPEAT COMMENTS:
  
 1) AS THE VALUE OF PROPOSED WORK EXCEEDS 50% OF THE
 VALUE OF THE HOME, LANDSCAPING SHALL BE IN COMPLIANCE
 WITH SECTION 94-442 OF THE ZONING AND LAND DEVELOPMENT
 REGULATIONS (ZLDR'S).
  
 2)AS THE STRUCTURE IS MORE THAN 50% DESTROYED IT
 SHALL BE REBUILT TO MEET ALL CURRENT CODES AND
 REGULATIONS. MUST MEET SETBACK REQUIREMENTS SET FORTH
 IN THE ZLDR'S, SECTION 94-72:
 FRONT = 25'
 SIDES = 5' MINIMUM WITH A TOTAL OF 15' BETWEEN THE TWO
 SIDES.
 REAR= 15' OR 10% OF THE LOT DEPTH.
  
 PLANS SHALL INDICATE SUCH.
  
  
 QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS,
 ZONING TECHNICIAN (561)805-6720

Review Stop Z ZONING
Rev No 2 Status F Date 2007-08-03 Cont ID  
Sent By choops Date 2007-08-03 Time 17:01 Rev Time 0.00
Received By choops Date 2007-08-03 Time 17:01 Sent To E
Notes
2007-08-03 17:15:53***FAILED - RESUB #1***
  
  
 1)AS THE VALUE OF PROPOSED WORK EXCEEDS 50% OF THE
 VALUE OF THE HOME, LANDSCAPING SHALL BE IN COMPLIANCE
 WITH SECTION 94-442 OF THE ZONING AND LAND DEVELOPMENT
 REGULATIONS (ZLDR'S).
  
 2)PLEASE PROVIDE SETBACK DIMENSION OF NOTCHED
 SECTION ON WEST SIDE OF HOUSE.MUST MEET CURRENT
 SETBACK REQUIREMENTS (SIDE SETBACKS MUST BE 5' MINIMUM
 WITH A TOTAL OF 15' BETWEEN THE TWO SIDES).AS THE
 PROPOSED ADDITION IS SHOWN WITH A SIDE SETBACK OF 7.4
 FEET THE WEST SIDE SETBACK MUST BE A MINIMUM OF 7.6
 FEET, IF NOT THE ADDITION MUST BE MOVED IN TO MEET THE
 SETBACK REQUIREMENTS.
  
 3)THE FRONT PORCH DOES NOT MEET THE FRONT SETBACK
 REQUIREMENT OF 25 FEET.
  
 4)THE BUILDING WALLS MUST BE MOVED IN TO MEET
 CURRENT SETBACK REQUIREMENTS PURSUANT TO THE CITY OF
 WEST PALM BEACH ZONING AND LAND DEVELOPMENT
 REGULATIONS, SECTION 94-513(2)(C)(1):A NONCONFORMING
 STRUCTURE OR BUILDING, OR A CONFORMING STRUCTURE OR
 BUILDING OCCUPIED BY A MAJOR USE NONCONFORMITY, WHICH
 IS DESTROYED MAY NOT BE REPLACED EXCEPT IN CONFORMITY
 WITH THE REQUIREMENTS OF THIS CHAPTER.
  
 AS THE STRUCTURE IS MORE THAN 50% DESTROYED IT SHALL BE
 REBUILT TO MEET ALL CURRENT CODES AND REGULATIONS. MUST
 MEET SETBACK REQUIREMENTS SET FORTH IN THE ZLDR'S,
 SECTION 94-72:
  
 FRONT = 25'SIDES = 5' MINIMUM WITH A TOTAL OF 15'
 BETWEEN THE TWO SIDES.REAR= 15' OR 10% OF THE
 LOT DEPTH.
  
 5)PLEASE INDICATE ANY PROPOSED A/C EQUIPMENT WITH
 SETBACK DIMENSIONS TO THE PROPERTY LINES.
  
  
  
 QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, ZONING
 TECHNICIAN
 (561)805-6720

Review Stop Z ZONING
Rev No 1 Status F Date 2007-05-08 Cont ID  
Sent By choops Date 2007-05-08 Time 16:31 Rev Time 0.00
Received By choops Date 2007-05-08 Time 16:31 Sent To P
Notes
2007-05-08 16:36:27***FAILED***
  
  
 1)PLEASE CLARIFY SCOPE OF WORK, AND INDICATE ON BOTH
 COPIES OF SURVEYS AND BOTH SITE PLANS.INDICATE WHAT
 WALLS ARE REMAINING AND WHAT WALLS ARE BEING REPLACED.
  
 2)PROVIDE A DEMOLITION PLAN OF WHAT PRESENTLY EXISTS
 AND WHAT IS GOING TO BE CONSTRUCTED IN PROPOSED
 PROJECT.
  
 3)PROVIDE PICTURES OR OLD SURVEY OR BOTH, SHOWING
 WHAT WAS DAMAGED AND WHAT IS BEING REPLACED.
  
  
 CHRIS HOOPS
 ZONING TECHNICIAN
 561-805-6720