Plan Review Stops For Permit 07040347 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
P |
Date |
2008-03-10 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2008-03-10 |
Time |
08:55 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2008-03-10 |
Time |
08:55 |
Sent To |
|
|
Notes |
2008-03-10 08:56:12 | REVISION |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2008-02-11 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2008-02-11 |
Time |
15:50 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2008-02-11 |
Time |
15:50 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2008-01-16 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2008-01-16 |
Time |
10:51 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2008-01-16 |
Time |
10:50 |
Sent To |
|
|
Notes |
2008-01-16 10:52:39 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBCFLORIDA BUILDING CODE 2004 | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | CODE | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | FAC FLORIDA ADMINISTRATIVE CODE | | FSFLORIDA STATUTE | | | | 1.FROM PREVIOUS LIST, NOT ADDRESSED - A DESIGN | | PRESSURE OF -79 REQUIRES USE OF THE 100PSF ROW, SHEET 6 | | OF THE PRODUCT APPROVAL.11" MINIMUM ANCHOR SPACING | | REQUIRED.PLEASE REVISE INSTALLATION SCHEDULE. | | | | 2ND REVIEW, INSTALLATION SCHEDULE STILL SPECIFIES 12". | | | | | | 2.THE ENGINEERING SUBMITTED IS FOR EXPOSURE B, THIS | | JOB IS IN EXPOSURE C, FBC1609.6.2.1(2). | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2007-10-23 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-10-23 |
Time |
08:56 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-10-23 |
Time |
08:56 |
Sent To |
|
|
Notes |
2007-10-23 08:58:24 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBCFLORIDA BUILDING CODE 2004 | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | CODE | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | | FAC FLORIDA ADMINISTRATIVE CODE | | FSFLORIDA STATUTE | | | | 1.A DESIGN PRESSURE OF -79 REQUIRES USE OF THE 100PSF | | ROW, SHEET 6 OF THE PRODUCT APPROVAL.11" MINIMUM | | ANCHOR SPACING REQUIRED.PLEASE REVISE INSTALLATION | | SCHEDULE. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2007-04-19 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-04-19 |
Time |
10:47 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-04-19 |
Time |
10:47 |
Sent To |
|
|
Notes |
2007-04-19 10:49:26 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBCFLORIDA BUILDING CODE 2004 | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | CODE | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC* | | CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | FACFLORIDA ADMINISTRATIVE CODE | | FSFLORIDA STATUTE | | | | ***ONLY CHECKED ITEMS APPLY*** | | | | _XX_1.A NOTICE OF COMMENCEMENT MUST BE FILED WITH | | THE CLERK OF COURTS PRIOR TO PERMIT PICKUP, FS713.13. | | | | _XX_2.THE DESIGN PRESSURE FOR THE WINDOW (SEE | | SHEETS 1 AND 2, -110) DOES NOT MEET THE DESIGN PRESSURE | | SPECIFIED BY THE ENGINEER (-143.9). | | | | _XX_3.PROVIDE A COPY OF THE CONDO ASSOCIATION | | APPROVAL. | | | | _XX_4.MARK THE MULLION PRODUCT APPROVAL TO SHOW | | WHICH PRODUCT YOU ARE USING.NOTE THAT FOR A 80" WIDE | | OPENING (37+37=74), 63 INCHES HIGH, 1X4 IS LIMITED TO | | DESIGN PRESSURE OF -128, BUT THE ENGINEER SPECIFIES | | -143.9. | | | | _XX_5..)PRODUCT APPROVALS ARE TO BE APPROVED BY | | DESIGNER OF RECORD, FBC*106.3.3. | | | | ____6.PROVIDE A FLOOR PLAN SHOWING: WINDOW | | LOCATIONS, SIZES, WINDOW TYPE, ROOM DESIGNATIONS.NOTE | | EXISTING CONDITIONS (TYPE OF WINDOW) AND OPENING SIZE | | FOR BEDROOMS, FBC R310, FBC EB 505.1. | | | | _XX_7.COMPLETE THE ATTACHED INSTALLATION SCHEDULE | | OR PROVIDE ALL INFORMATION TO SHOW CODE COMPLIANCE IN | | ANOTHER FORMAT.(SHUTTERS) | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2008-03-05 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-03-05 |
Time |
09:16 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-03-05 |
Time |
09:16 |
Sent To |
B |
|
Notes |
2008-03-05 09:16:48 | TO "SHILL" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2008-02-06 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-02-06 |
Time |
11:07 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-02-06 |
Time |
11:07 |
Sent To |
B |
|
Notes |
2008-02-06 11:08:20 | TO "SHILL" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2008-01-14 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-01-14 |
Time |
13:23 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-01-14 |
Time |
13:23 |
Sent To |
B |
|
Notes |
2008-01-14 13:23:49 | TO "SHILL" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2007-10-17 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-10-17 |
Time |
11:12 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-10-17 |
Time |
11:12 |
Sent To |
B |
|
Notes |
2007-10-17 11:12:29 | TO "SHILL" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2007-04-19 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-04-19 |
Time |
11:15 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-04-12 |
Time |
08:47 |
Sent To |
|
|
Notes |
2007-04-12 08:47:31 | TO "MISC" BOX#1 |
|
|