Plan Review Details - Permit 07040347
Plan Review Stops For Permit 07040347
Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2008-03-10 Cont ID  
Sent By shill Date 2008-03-10 Time 08:55 Rev Time 0.00
Received By shill Date 2008-03-10 Time 08:55 Sent To  
Notes
2008-03-10 08:56:12REVISION

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2008-02-11 Cont ID  
Sent By shill Date 2008-02-11 Time 15:50 Rev Time 0.00
Received By shill Date 2008-02-11 Time 15:50 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2008-01-16 Cont ID  
Sent By shill Date 2008-01-16 Time 10:51 Rev Time 0.00
Received By shill Date 2008-01-16 Time 10:50 Sent To  
Notes
2008-01-16 10:52:39****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
 FAC FLORIDA ADMINISTRATIVE CODE
 FSFLORIDA STATUTE
  
 1.FROM PREVIOUS LIST, NOT ADDRESSED - A DESIGN
 PRESSURE OF -79 REQUIRES USE OF THE 100PSF ROW, SHEET 6
 OF THE PRODUCT APPROVAL.11" MINIMUM ANCHOR SPACING
 REQUIRED.PLEASE REVISE INSTALLATION SCHEDULE.
  
 2ND REVIEW, INSTALLATION SCHEDULE STILL SPECIFIES 12".
  
  
 2.THE ENGINEERING SUBMITTED IS FOR EXPOSURE B, THIS
 JOB IS IN EXPOSURE C, FBC1609.6.2.1(2).
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2007-10-23 Cont ID  
Sent By shill Date 2007-10-23 Time 08:56 Rev Time 0.00
Received By shill Date 2007-10-23 Time 08:56 Sent To  
Notes
2007-10-23 08:58:24****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
  
 FAC FLORIDA ADMINISTRATIVE CODE
 FSFLORIDA STATUTE
  
 1.A DESIGN PRESSURE OF -79 REQUIRES USE OF THE 100PSF
 ROW, SHEET 6 OF THE PRODUCT APPROVAL.11" MINIMUM
 ANCHOR SPACING REQUIRED.PLEASE REVISE INSTALLATION
 SCHEDULE.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-04-19 Cont ID  
Sent By shill Date 2007-04-19 Time 10:47 Rev Time 0.00
Received By shill Date 2007-04-19 Time 10:47 Sent To  
Notes
2007-04-19 10:49:26****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC*
 CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
 FACFLORIDA ADMINISTRATIVE CODE
 FSFLORIDA STATUTE
  
 ***ONLY CHECKED ITEMS APPLY***
  
 _XX_1.A NOTICE OF COMMENCEMENT MUST BE FILED WITH
 THE CLERK OF COURTS PRIOR TO PERMIT PICKUP, FS713.13.
  
 _XX_2.THE DESIGN PRESSURE FOR THE WINDOW (SEE
 SHEETS 1 AND 2, -110) DOES NOT MEET THE DESIGN PRESSURE
 SPECIFIED BY THE ENGINEER (-143.9).
  
 _XX_3.PROVIDE A COPY OF THE CONDO ASSOCIATION
 APPROVAL.
  
 _XX_4.MARK THE MULLION PRODUCT APPROVAL TO SHOW
 WHICH PRODUCT YOU ARE USING.NOTE THAT FOR A 80" WIDE
 OPENING (37+37=74), 63 INCHES HIGH, 1X4 IS LIMITED TO
 DESIGN PRESSURE OF -128, BUT THE ENGINEER SPECIFIES
 -143.9.
  
 _XX_5..)PRODUCT APPROVALS ARE TO BE APPROVED BY
 DESIGNER OF RECORD, FBC*106.3.3.
  
 ____6.PROVIDE A FLOOR PLAN SHOWING: WINDOW
 LOCATIONS, SIZES, WINDOW TYPE, ROOM DESIGNATIONS.NOTE
 EXISTING CONDITIONS (TYPE OF WINDOW) AND OPENING SIZE
 FOR BEDROOMS, FBC R310, FBC EB 505.1.
  
 _XX_7.COMPLETE THE ATTACHED INSTALLATION SCHEDULE
 OR PROVIDE ALL INFORMATION TO SHOW CODE COMPLIANCE IN
 ANOTHER FORMAT.(SHUTTERS)
  
  

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2008-03-05 Cont ID  
Sent By adarroug Date 2008-03-05 Time 09:16 Rev Time 0.00
Received By adarroug Date 2008-03-05 Time 09:16 Sent To B
Notes
2008-03-05 09:16:48TO "SHILL" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2008-02-06 Cont ID  
Sent By adarroug Date 2008-02-06 Time 11:07 Rev Time 0.00
Received By adarroug Date 2008-02-06 Time 11:07 Sent To B
Notes
2008-02-06 11:08:20TO "SHILL" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2008-01-14 Cont ID  
Sent By adarroug Date 2008-01-14 Time 13:23 Rev Time 0.00
Received By adarroug Date 2008-01-14 Time 13:23 Sent To B
Notes
2008-01-14 13:23:49TO "SHILL" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-10-17 Cont ID  
Sent By adarroug Date 2007-10-17 Time 11:12 Rev Time 0.00
Received By adarroug Date 2007-10-17 Time 11:12 Sent To B
Notes
2007-10-17 11:12:29TO "SHILL" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-04-19 Cont ID  
Sent By shill Date 2007-04-19 Time 11:15 Rev Time 0.00
Received By shill Date 2007-04-12 Time 08:47 Sent To  
Notes
2007-04-12 08:47:31TO "MISC" BOX#1