Plan Review Details - Permit 07040075
Plan Review Stops For Permit 07040075 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2007-05-09 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-05-09 |
Time |
11:33 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-05-09 |
Time |
11:33 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2007-04-21 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-04-21 |
Time |
12:45 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-04-21 |
Time |
12:44 |
Sent To |
|
|
Notes |
2007-04-21 12:53:27 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBCFLORIDA BUILDING CODE 2004 | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | CODE | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC* | | CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 FAC | | FLORIDA ADMINISTRATIVE CODE | | FSFLORIDA STATUTE | | | | | | 1.)OPENING REFERENCED IN PREVIOUS LIST WAS NOT | | REVISED. | | | | 2.)THIS IS EXPOSURE C.YOU HVE DESIGNED TO 47.2 | | EXPOSURE B WORST CASE.THIS IS NOT HIGH ENOUGH FOR | | SOME OPENINGS, SUCH AS SOME ON THE END ZONES SUCH AS | | OPENING 5.WORST CASE FOR EXPOSURE C, 15' MRH, IS | | -57.1.OPENING 5 WOULD REQUIRE 9" SPACING, NOT 12". | | | | 3.) OPENING 4 REQUIRES USE OF THE 15' CHART, HAS A | | MINIMUM REQUIRED DESIGN PRESSURE OF -48.19, SO YOU MUST | | USE THE -77PSF CHART.THIS REQUIERS 4" SPACING, NOT | | 12". | | | | 4.)SOME OF THE OPENING SIZES DO NOT ALL CORRELATE | | WITH THE FLOOR PLAN; FOR INSTANCE, SEE OPENING 18.ONE | | STATES 26X57, ONE IS 26X50. | | | | 5.)CHECK ALL OPENINGS.OTHER OPENINGS MAY HAVE | | INCORRECT ANCHOR SPACING. | | | | 6.)THERE ARE TWO DIFFERENT FLORIDA STATE PRODUCT | | APPROVALS INCLUDED IN THE PACKAGE, ONE EVALUATION | | REPORT.INCLUDE ONLY THE FL STATE PA THAT APPLIES TO | | THIS JOB. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2007-04-07 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-04-07 |
Time |
14:42 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-04-07 |
Time |
14:42 |
Sent To |
|
|
Notes |
2007-04-07 14:43:26 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBCFLORIDA BUILDING CODE 2004 | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | CODE | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL | | FBC*CITY OF WEST PALM BEACH AMENDMENTS TO THE | | FBC2004 | | FACFLORIDA ADMINISTRATIVE CODE | | FSFLORIDA STATUTE | | | | 1.)SEE OPENING 11.THIS REQUIRES 4" SPACING, SEE | | PRODUCT APPROVAL. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2007-05-07 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-05-07 |
Time |
14:43 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-05-07 |
Time |
14:43 |
Sent To |
B |
|
Notes |
2007-05-07 14:43:51 | TO "SHILL" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2007-04-30 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-04-30 |
Time |
16:22 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-04-30 |
Time |
16:22 |
Sent To |
B |
|
Notes |
2007-04-30 16:22:21 | TO "SHILL" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2007-04-18 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-04-18 |
Time |
11:18 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-04-18 |
Time |
11:18 |
Sent To |
B |
|
Notes |
2007-04-18 11:18:18 | TO "SHILL"DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2007-04-07 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-04-07 |
Time |
14:43 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-04-03 |
Time |
18:28 |
Sent To |
|
|
Notes |
2007-04-03 18:28:11 | TO MISC # 1 |
|
|
|