Plan Review Details - Permit 07031080
Plan Review Stops For Permit 07031080
Review Stop B BUILDING (STRUCTURAL)
Rev No 7 Status P Date 2008-02-28 Cont ID  
Sent By jgomez Date 2008-02-28 Time 16:36 Rev Time 0.00
Received By jgomez Date 2008-02-28 Time 16:36 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 6 Status F Date 2008-02-20 Cont ID  
Sent By jgomez Date 2008-02-20 Time 13:04 Rev Time 0.00
Received By jgomez Date 2008-02-20 Time 13:04 Sent To PC
Notes
2008-02-20 13:32:19RESIDENTIAL ADDITION BUILDING REVIEW SIXTH CHECKLIST.
 REVIEW UNDER FBC 2004 WITH 2006 REVISIONS.
  
 1- FLAT ROOFASSEMBLY NAIL ENHANCING SPACING AT
 PERIMETER AND CORNER AREAS SHOWN ON SHEET A1 ARE
 EXACTLY THE SAMEAS SHOWN ON NOA 03-0501.05.ENGINEER
 IS NOT PROVIDING ANY NAIL ENHANCING ON THE CONTRARY IS
 PROVIDING THE SAME SPECIFICATIONS THAT ARE SHOWN ON THE
 PRODUCT APPROVAL ON SHEET 18 OF 21.ENGINEER TO READ
 HOW TO DO THE RAS 117 CALCULATIONS AS REQUIRED BY
 GENERAL LIMITATION #7 OF NOA SUBMITTED AND PROVIDE SUCH
 CALCULATIONS. SEC. 106.1.2 CITY AMENDMENTS TO FBC 2004
 TO VERIFY COMPLIANCE WITH TABLE R301.2(2) OF 2004
 FLORIDA RESIDENTIAL CODE.
  
 ***NOTE: ONE SET OF PLANS WILL BE RETAINED IN THIS
 OFFICE TO BE SEND TO THE BOARD OF ENGINEER'S FOR
 REVIEW.
  
 2- PLANS SUBMITTED NOW ARE REVISED FROM THOSE SUBMITTED
 ON EARLIER RE-SUBMITTALS. NOW ALL THE AREA CALCULATIONS
 DON'T MATCH ACTUAL AREAS SHOWN ON PLANS AND DON'T ADD
 UP CORRECTLY.REVISE AS REQUIRED. PERMIT FEES AND
 RADON FEES WILL BE ADJUSTED ACCORDINGLY ONCE THE AREA
 CALCULATIONS ARE CORRECTED.
  
 3- NOTICE OF COMMENCEMENT EXPIRES AFTER 90 DAYS IF WORK
 IS NOT STARTED.NEED RE-RECORDED NOC AS REQUIRED BY
 SEC. 713.13 FLORIDA STATUTE.
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status F Date 2007-12-12 Cont ID  
Sent By jgomez Date 2007-12-12 Time 13:29 Rev Time 0.00
Received By jgomez Date 2007-12-12 Time 12:37 Sent To PC
Notes
2007-12-12 13:46:00RESIDENTIAL ADDITION BUILDING REVIEW FIFTH CHECKLIST.
 REVIEW UNDER FBC 2004 WITH 2006 REVISIONS.
  
 1- ENERGY CALCULATIONS:R VALUES SHOWN FOR ROOF AND
 WALLS ON ENERGY CALCULATIONS DON'T MATCH THOSE SHOWN ON
 PLANS.REVISE AS REQUIRED TO MATCH.
 ALSO, SEE MECHANICAL PLAN REVIEWER COMMENTS AND
 COORDINATE AS REQUIRED.
 ACCORDING TO TABLE 6C-1 THE MINIMUM WALL INSULATION IS
 R-5. THEN, WHY INSTALLING R-4.2?. REVISE AS REQUIRED.
  
 2- DIMENSIONS SHOWN ON SURVEY DON'T MATCH DIMENSIONS
 SHOWN ON PLANS. REVISE AS REQUIRED.(REPEAT COMMENT).
  
 3- FLAT ROOF PRODUCT APPROVAL:
 A) CLEARLY SPECIFY ON SELECTED ASSEMBLY , PAGE 18,
 THE SPECIFIC FASTENING OPTION FOR BASE SHEET TO BE USED
 TO VERIFY COMPLIANCE WITH THE UPLIFT DESIGN PRESSURES.
 (REPEAT COMMENT).
  
 B) PROVIDE RAS 117 CALCULATIONS FOR NAIL ENHANCING
 AT PERIMETER AND CORNER AREAS. SEE GENERAL LIMITATION
 #7 ON LAST PAGE OF NOA SUBMITTED. (REPEAT COMMENT).
  
 4- ROOF FRAMING PLAN: REVISE NUMBER OF NAILS TO BE USED
 FOR SIMPSON MTSM20. SEE CURRENT CATALOG AND REVISE AS
 REQUIRED. OTHERWISE, PROVIDE COMPLETE ENGINEERINGFOR
 NAIL FASTENERS THAT DIFFER FROM THOSE TESTED AND
 PUBLISHED BY THE MANUFACTURER. SEC. 106.1.2 CITY
 AMENDMENTS TO FBC 2004.
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status F Date 2007-10-02 Cont ID  
Sent By jgomez Date 2007-10-02 Time 12:50 Rev Time 0.00
Received By jgomez Date 2007-10-02 Time 12:34 Sent To PC
Notes
2007-10-02 15:15:00RESIDENTIAL ADDITION BUILDING REVIEW FOURTH CHECKLIST.
  
 REVIEW DONE UNDER 2004 FLORIDA RESIDENTIAL CODE AND FBC
 2004.
  
 1- ENERGY CALCULATIONS (FIRST TIME ENERGY CALCS ARE
 SUBMITTED):
 A) OWNER/AGENT NEEDS TO SIGN AND DATE BOTTOM OF
 FORM.
 B) JURISDICTION NUMBER ON TOP OF FORM IS INCORRECT.
 REVISE AS REQUIRED.
 C) COMPLETE ALL INFORMATION ON TOP OF FORM,
 INCLUDING NAME OF BUILDER AND PERMITTING OFFICE.
 D) CLARIFY WHY THE CONDITIONED FLOOR AREA ON ITEM #4
 IS 210SF, WHILEUNDER ATTIC SQUARE FOOTAGE ON ITEM
 #10(A) IS 274SF. SEC. 106.1.2 CITY AMENDMENTS TO FBC
 2004.
 E) COMPLETE INFORMATION ON TABLE 6C-1.
 F) INFORMATION ON TABLE 6C-2 IS WRONG. REVISE AS
 REQUIRED.
  
 2- ROOF FRAMING PLAN: REVISE NUMBER OF FASTENERS
 SPECIFIED FOR SIMPSON HETAL20 CONNECTOR.SEE CURRENT
 SIMPSON CATALOG AND REVISE AS REQUIRED.OTHERWISE
 PROVIDE COMPLETE ENGINEERING ANALYSISFOR NUMBER OF
 FASTENERS THAT DIFFER FROM THOSE TESTED AND PUBLISHED
 BY THE MANUFACTURER. SEC. 106.1.2 CITY AMENDMENTS TO
 FBC 2004.
  
 3- ROOF FRAMING PLAN AND EXISTING WALL:NEED TO
 SPECIFY WOOD TO MASONRY CONNECTOR FOR ROOF JOISTS THAT
 ARE RESTING ON EXISTING EXTERIOR WALL.FLOOR PLAN
 SHOWS THIS WALL AS CONCRETE BLOCK WALL WITH FILLED
 CELLS AT DOOR OPENING.CONNECTOR MTS-18IS A WOOD TO
 WOOD CONNECTOR. REVISE INFORMATION ON ROOF FRAMING PLAN
 AS REQUIRED. CLEARLY IDENTIFY WHAT KIND OF WALL IS THE
 EXISTING WALL. IS IT MASONRY OR WOOD FRAMED WALL?. SEC.
 106.1.2 CITY AMENDMENTS TO FBC 2004. (THIS INFORMATION
 WAS REQUESTED ON PREVIOUS CHECKLIST ALSO).
  
 4- SOFFIT VENTILATION SPECS SHOWN ON WALL STEM DETAIL
 ON SHEET A2 WERE REVISED AGAIN AND STILLDON'T COMPLY
 WITH SEC. R806 OF 2004 FLORIDA RESIDENTIAL CODE.NEED
 TO PROVIDE CROSS VENTILATION.SEPARATE VENTS DON'T
 PROVIDE CROSS VENTILATION ON A FLAT ROOFWITH 2X12
 ROOF JOISTS. REVISE AS REQUIRED.
  
 5- WALL STEM DETAIL ON SHEET A2: SPECIFICATIONS FOR
 INTERIOR CEILING CONSTRUCTION ARE NOT CLEAR.REVISE
 INFORMATION AS REQUIRED. REMEMBER THIS IS AN INTERIOR
 CEILING. ALSO, WHERE IS THE FIREBLOCKING LOCATED AT?.
 THERE ARE NOT TRUSSES IN THIS ROOF EITHER.WHY USING
 EXTERIOR GRADE GYPSUM BOARD?. SEC. 106.1.2 CITY
 AMENDMENTS TO FBC 2004. REVISE COMPLETE SPECS AS
 REQUIRED.
  
 6- REVISE EMERGENCY EGRESS WINDOWS INFORMATION ON SHEET
 A2:
 A) REVISE REFERENCES. SEC. 1005.4 AND SEC. 105.43
 DON'T CORRESPOND TO 2004 FLORIDA RESIDENTIAL CODE.
 B) NET CLEAR OPENING OF 20". IS THIS FOR CLEAR WIDTH?.
 REVISE AS REQUIRED.
 C) EGRESS IS MEASURED BY EGRESS CLEAR OPENING,NOT
 MINIMUM TOTAL GLASS AREA. REVISE AS REQUIRED.
  
 7- STRUCTURAL LOADS ON SHEET A2:
 A) FLOOR AND ROOF LIVE LOADS CAN'T BE 10PSF.REVISE
 AS REQUIRED.
 B) CLARIFY WHY CEILING DEAD LOAD IS 20LBS?. SEC.
 106.1.2 CITY AMENDMENTS TO FBC 2004.
 C) CLARIFY WHYSUBMITTING WALL INTERIOR AND
 EXTERIOR DEAD LOADS AND WHERE ARE THESE NUMBERSTAKEN
 FROM. SEC. 106.1.2 CITY AMENDMENTS TO FBC 2004.
 D) SPECIFY BUILDING CODE USED AND WIND LOADS AS
 REQUIRED BY SEC. R301 OF 2004 FLORIDA RESIDENTIAL CODE.
 THESE INFORMATION WAS GIVEN ON PREVIOUS SUBMITTALS, BUT
 NOW IS NOT SHOWN ON PLANS. PROVIDE ALL REQUIRED
 INFORMATION.
  
 8- PROVIDE PRODUCT APPROVAL AS REQUIRED BY RULE 9B-72
 FOR:
 A) FLAT ROOF ASSEMBLY:
 * NOA 04-0506.03 EXPIRED ON 5-23-07. NEED CURRENT ONE.
  
 ** NOA 04-0506.03 SUBMITTEDHAS NOTHNG TO DO WITH
 FL735.
 *** CLEARLY IDENTIFY SPECIFIC APPROVED ASSEMBLY TO BE
 INSTALLED.
 **** CLEARLY IDENTIFY ASSEMBLY BASE SHEET FASTENING
 OPTION.
 ***** PROVIDE RAS 117 CALCULATIONS AS REQUIRED BY
 GENERAL LIMITATION #7. SEE GENERAL LIMITATION #7 ON
 LAST PAGE OF NOA SUBMITTED. (NOTE: IF GENERAL
 LIMITATION #7 STATES THAT RAS 117 CALCULATIONS MUST BE
 DONE BY A PROFESSIONAL ARCHITECT, ENGINEER OR
 REGISTERED ROOF CONSULTANT, THEN SUCH CALCS MUST BE
 DONE BY ONE OF THEM ONLY).
  
 SEC. 106.1.2 CITY AMENDMENTS TO FBC 2004.
  
 9- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING)ALL PRODUCT APPROVALS AS
 REQUIRED BY SEC. 106.3.3 CITY AMENDMENTS TO FBC 2004.
 USE COMPANY STANDARD REVIEW STAMP OR WRITE ENGINEERS
 NAME AND CLEARLY WRITE REVIEWED AND APPROVED AND SIGNED
 BY WHO DID THE REVIEW. PRODUCT APPROVALS SUBMITTED WERE
 REVIEWED BY SOMEBODY ELSE OTHER THAN THE ENGINEER OF
 RECORD. AND ENGINEER'S SIGNATURE WITHOUT NAME IS NOT
 INFORMATION ADEQUATE ENOUGH TO IDENTIFY PERSON WHO
 REVIEW THE PRODUCT APPROVAL. THESE COMMENT WAS
 ADDRESSED ON SEVERAL OCCASIONS.
  
 10- SURVEY AND FLOOR PLANS DON'T MATCH REVISE
 DIMENSIONS AS REQUIRED TO MATCH. SEC. 106.1.2 CITY
 AMENDMENTS TO FBC 2004.
  
 11- NOTICE OF COMMENCEMENT WAS RECORDED ON 03/30/07.
 NOTICE OF COMMENCEMENT EXPIRES AFTER 90 DAYS OF
 RECORDING IF WORK IS NOT STARTED.SEC. 713.13 FLORIDA
 STATUTE. NEED RE-RECORDED NOTICE OF COMMENCEMENT.
  
 12- NOW TYPICAL WALL SECTION IS MISSING THE ROOF AND
 WALL INSULATION. PROVIDE COMPLETE SPECIFICATIONS AS
 REQUIRED. SEC. 13-600 FBC 2004.
  
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2007-07-30 Cont ID  
Sent By jgomez Date 2007-07-30 Time 13:28 Rev Time 0.00
Received By jgomez Date 2007-07-30 Time 13:28 Sent To PC
Notes
2007-07-30 14:43:47BUILDING REVIEW THIRD CHECKLIST:
 1- THIS IS THE THIRD TIME THAT THE ENERGY CALCULATIONS
 (FORM 600B-04ROR 600C-04R)ARE REQUESTED AS REQUIRED
 BY SEC. 13-600.3.ABC.3FBC 2004.
  
 2- ROOF FRAMING PLAN: REVISE NUMBER OF FASTENERS
 SPECIFIED FOR SIMPSON HETAL20 CONNECTOR TO ACHIEVE THE
 SPECIFIED UPLIFT LOAD.SEE CURRENT SIMPSON CATALOG AND
 REVISE AS REQUIRED. OTHERWISE, PROVIDE COMPLETE
 ENGINEERING ANALYSIS TO DEMONSTRATE WHY NUMBER OF
 FASTENERS IS DIFFERENT THAN THAT TESTED AND PUBLISHED
 BY THE MANUFACTURER. SEC. 106.1.2 CITY AMENDMENTS TO
 FBC 2004.
  
 3- PROVIDE COMPLETE SPECIFICATIONS FOR SOFFIT
 CONSTRUCTION. "STUCCO FINISH SOFFIT" ARE NOT COMPLETE
 SPECIFICATIONS. SEC. 106.1.2 CITY AMENDMENTS TO FBC
 2004.
  
 4-SOFFIT VENTILATION WAS CHANGED.NEW SPECS CALL FOR
 7" X 24"AT 24" O.C. VENTS.THEY ARE ARE NOT ENOUGH
 TO PROVIDE CROSS VENTILATION AS REQUIRED BY SEC. R806
 FOR FLAT ROOFS. REVISE AS REQUIRED.
  
 5- REVISE REFERENCES FOR EMERGENCY EGRESS WINDOWS. SEE
 RESIDENTIAL CODE FOR CORRECT CODE SECTIONS TO BE USED.
 ON THE OTHER HAND,EGRESS WINDOWS ARE NOT REQUIRED FOR
 BATHROOM WINDOWS.
  
 6- PROVIDE PRODUCT APPROVAL AS REQUIRED BY DCA RULE
 9B-72 FOR:
 A) STORM SHUTTERS. DRAWINGS SUBMITTED ARE NOT AN
 APPROVED PRODUCT APPROVAL.
 ***NOTE: ALSO, CLEARLY INDICATE ON SHUTTER DRAWINGS
 SPECIFIC MOUNTING CONDITIONS (EG; WALL MOUNTED, ETC)
 AND SPECIFIC ANCHOR TYPE AND SPACING TO BE USED.
  
 B) FLAT ROOF ASSEMBLY. AND CLEARLY IDENTIFY SPECIFIC
 ASSEMBLY TO BE INSTALLED AND SPECIFIC FASTENING OPTION.
  
 ALSO, PROVIDE RAS 117 CALCULATIONS FOR NAIL ENHANCING
 AT PERIMETER AND CORNER AREAS AS REQUIRED BY GENERAL
 LIMITATION #7.
  
 7- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS
 REQUIRED BY SEC. 106.3.3 CITY AMENDMENTS TO FBC 2004.
 ***NOTE: ENGINEER NEEDS TO WRITE HIS NAME ON REVIEW
 STAMP.REVIEW & APPROVE STAMP ALONE IS NOT ACCEPTABLE
 BECAUSE IT DOESN'T SAY WHO REVIEWED THE PRODUCT
 APPROVAL.
  
 8- SURVEY AND FLOOR PLANS DON'T MATCH. SEE DIMENSIONS
 AND BUILDING LAYOUT. REVISE AS REQUIRED TO MATCH.
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2007-06-15 Cont ID  
Sent By jgomez Date 2007-06-15 Time 16:28 Rev Time 0.00
Received By jgomez Date 2007-06-15 Time 16:28 Sent To PC
Notes
2007-06-15 17:02:06BUILDING REVIEW 2ND CHECKLIST:
 1- ROOF FRAMING PLAN:
 A) SPECIFY HOW MANY FASTENERS ARE REQUIRED FOR TRUSS
 CONNECTORS. INFORMATION IS MISSING.
  
 B) ROOF FRAMING PLAN SPECIFIESEXISTING WALL TO BE
 WOOD FRAMING.ROOF FRAMING PLAN SHOWS PRECAST LINTEL
 ABOVE DOOR OPENING.HOW CAN YOU HAVE A PRECAST LINTEL
 ON A WOOD FRAMED WALL?. ALSO, FLOOR PLAN SHOW CONCRETE
 BLOCK WALL AND CONCRETE FILLED COLUMNS AT BOTH ENDS OF
 SWING DOOR. CLARIFY/REVISE DRAWINGS AS REQUIRED TO
 MATCH.
  
 2- WALL STEM WALL:
 A) FIREBLOCKING AND FINISH CEILING INFORMATION IS
 MIXED UP.THESE ARE TWO DIFFERENT CODE ISSUES. PROVIDE
 INFORMATION FOR CEILING ASSEMBLY AND INFORMATION FOR
 FIREBLOCKING SEPARATELY. REVISE/CLARIFY NOTE AS
 REQUIRED. SEC. 106.1.2 CITY AMENDMENTS TO FBC 2004.
  
 B) PROVIDE COMPLETE SPECS FOR SOFFIT INSTALLATION.
 INFORMATION SUBMITTED IS INCOMPLETE."MASONRY TEXT.
 FINISH SOFFITS W/3"CONT VENT" IS NOT ENOUGH
 INFORMATION.SEC. 106.1.2 CITY AMENDMENTS TO FBC
 2004.
  
 3- STRUCTURAL LOADS INFORMATION IS INCORRECT:
 A) FLOOR AND ROOF LIVE LOADS CAN'T BE ONLY 10PSF.
 SEE SECTIONS R301 AND TABLE R301.5 OF 2004 FLORIDA
 RESIDENTIAL CODE FOR REQUIRED LOADS TO BE CONSIDERED.
 ALSO, INCLUDE ATTIC LIVE LOADS.
  
 4- EMERGENCY EGRESS WINDOWS.2004 SEE FLORIDA
 RESIDENTIAL BUILDING CODE AND 2006 REVISIONS AND CITE
 SPECIFIC SECTIONS THAT APPLY TO THIS PROJECT.
 INFORMATION SUBMITTED IS MISMATCHING THE FLORIDA
 RESIDENTIAL CODE AND THE FLORIDA BUILDING CODE.
  
 5- PROVIDE PRODUCT APPROVAL AS REQUIRED BY DCA RULE
 9B-72 FOR:
 A) PRECAST LINTELS.NOA 03-0605.04 SUBMITTED IS FOR
 4", 6" AND 12" PRECAST LINTELS.NEED PRODUCT APPROVAL
 FOR 8" PRECAST LINTELS.
  
 B) SINGLE HUNG WINDOWS.
  
 C) STORM SHUTTERS IF WINDOW DOESN'T HAVE IMPACT
 GLASS. AND, CLEARLY SPECIFY ANCHOR TYPE AND SPACING TO
 BE USED. SEE SHUTTERS ENGINEERING DRAWINGS.
  
 D) FLAT ROOF ASSEMBLY. AND CLEARLY IDENTIFY SPECIFIC
 ASSEMBLY TO BE INSTALLED AND SPECIFIC FASTENING OPTION.
 ALSO, PROVIDE NAIL ENHANCING FOR PERIMETER AND CORNER
 AREAS PER RAS 117 AS IT'S TYPICALLY REQUIRED BY GENERAL
 LIMITATION #7.SEE GENERAL LIMITATION #7 ON LAST PAGE
 OF REPORT.SEE ATTACHED CITY POLICY FOR ROOFING
 PERMITS.
  
 6- ENGINEER OF RECORD TO REVIEWAND APPROVE IN WRITING
 (NOT SIGNING AND SEALING)ALL PRODUCT APPROVALS AS
 REQUIRED BY SEC. 106.3.3 CITY AMENDMENTS TO FBC 2004.
 ***NOTE; MAKE SURE NAME OF ENGINEER WHO REVIEWS THE
 PRODUCT APPROVAL IS CLEAR.PRODUCT APPROVALS SUBMITTED
 ONLY STATES "REVIEW & APPROVED". NEED THE NAME OF
 ENGINEER WHO REVIEWED THE PRODUCT APPROVAL.
  
 7- PROVIDE THE ENERGY CALCULATIONS COMPLETELY FILLED
 AND SIGNED AND DATED BY THE OWNER.AGENT.NOW AT TIME
 OF PERMIT. NOTAT A LATER DATE. SEC. 13-600 FBC 2004.
  
 8- OWES $44.06 FOR UPDATED VALUATION PLUSADDITIONAL
 RESUBMITTAL FEES WILL BE CHARGED AFTER THE FIRST
 RE-SUBMITTAL.
  
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-04-26 Cont ID  
Sent By jgomez Date 2007-04-26 Time 07:54 Rev Time 0.00
Received By jgomez Date 2007-04-26 Time 07:39 Sent To PC
Notes
2007-04-26 10:18:53BUILDING REVIEW CHECKLIST:
 1-SHEET A1:
 A) ROOF FRAMING PLAN:
 * SPECIFIED SIMPSON CONNECTORS ARE WOOD TO WOOD
 CONNECTORS. NEED TO SPECIFY WOOD TO MASONRY CONNECTORS.
 SEE CURRENT CATALOG FOR CORRECT CONNECTOR AND FASTENING
 TYPE AND NUMBER AND REVISE AS REQUIRED. SEC. 106.1.2
 CITY AMENDMENTS TO FBC 2004.
 ** CLEARLY SPECIFY CONNECTORS FOR ROOF RAFTER/JOIST TO
 MASONRY WALL AND FOR ROOF RAFTER TO ROOF JOIST. SEC.
 106.1.2 CITY AMENDEMNTS TO FBC 2004.
  
 B) FOUNDATION PLAN/FLOOR PLAN: STARTER COLUMN IS NOT
 DRAWN CORRECTLY. NOTE CALLS FOR CONCRETE POURED COLUMN,
 WHILE DRAWING SHOW CONCRETE FILLED CELL. REVISE AS
 REQUIRED TO MATCH AND AVOID CONFUSIONS.SEC. 106.1.2
 CITY AMENDMENTS TO FBC 2004.
  
 2- SHEET A2:
 A) WALL STEM DETAIL:
 * REVISE SIMPSON CONNECTORS. SEE ITEM 1(A) ABOVE.
 ** REVISETYPE OF FLAT ROOF SPECIFIED. SEE PRODUCT
 APPROVAL FOR SPECIFIC MANUFACTURER AND ASSEMBLY TO BE
 INSTALLED.WHAT DOES BY "BITUMEN" ON 43 LB STANDS
 FOR?. SEC. 106.1.2 CITY AMENDMENTS TO FBC 2004.
 *** REVISE FASCIA DETAIL.REVISE SIZE AND PROPER WAY
 OF INSTALLING DRIP EDGE. SEC. 106.1.2 CITY AMENDEMNTS
 TO FBC 2004.
 **** SPECIFY FIREBLOCKING AS REQUIRED BY SEC. R602.8 OF
 2004 FLORIDA RESIDENTIAL CODE.
 ***** THERE ARE 2 DIFFERENT SPECS FOR FURRING STRIPS ON
 THE SAME WALL. REVISE AS REQUIRED.
  
 B) SHOWER RECESS DETAIL DOESN'T MATCH INFORMATION ON
 FOUNDATION PLAN. REVISE AS REQUIRED.
  
 C) PROVIDE ONLY THE INFORMATION THAT CORRESPONDS TO
 THIS PROJECT TO EXPEDITE REVIEW PROCESS AND AVOID
 CONFLICTS/CONFUSIONS. SEC. 106.1.2 CITY AMENDMENTS TO
 FBC 2004.
  
 D) REVISE DESIGN WIND PRESSURES FOR ROOF AREA. NEED
 TO USE 10SFTRIBUTARY AREA FOR COMPONENTS AND CLADDING
 FOR ROOF ASSEMBLY.SEE REVISED TABLE 1609.6.2.1(2) OF
 FBC 2004.
  
 3-ENGINEER NEEDS TO CONTACT DBPR TO RESOLVE ISSUE
 WITH HIS LICENSE STATUS.NEED CURRENT AND ACTIVE
 STATUS TO PROVIDE ENGINEERING SERVICES. DBPR WEBSITE
 SHOWS LICENSE UNDER A DELINQUENT STATUS.NEED TO
 CORRECT THIS BEFORE RE-SUBMITTING PLANS.
  
 4- PROVIDE PRODUCT APPROVAL AS REQUIRED BY DCA RULE
 9B-72 FOR:
 A) PRECAST LINTELS.
 B) ALL SIMPSON CONNECTORS SPECIFIED ON PLANS.
  
 5- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING)ALL PRODUCT APPROVALS AS
 REQUIRED BY SEC. 106.3.3 CITY AMENDMENTS TO FBC 2004.
  
 6- NEED TO PROVIDE THE ENERGY CALCULATIONS COMPLETELY
 FILLED AND SIGNED AND DATEDAS REQUIRED BY SEC. 13-600
 FBC 2004.
  
 7- ENGINEER SEAL IS NOT LEGIBLE AND WHAT'S DATED
 1-30-06?
  
 8- OWES $44.06 FOR UPDATED VALUATION AND RADON FEES.
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712

Review Stop E ELECTRICAL
Rev No 7 Status P Date 2008-02-28 Cont ID  
Sent By btrobaug Date 2008-02-28 Time 12:04 Rev Time 0.00
Received By btrobaug Date 2008-02-28 Time 11:22 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 6 Status P Date 2008-02-19 Cont ID  
Sent By btrobaug Date 2008-02-19 Time 10:14 Rev Time 0.00
Received By btrobaug Date 2008-02-19 Time 09:35 Sent To M
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 5 Status P Date 2007-11-08 Cont ID  
Sent By btrobaug Date 2007-11-08 Time 09:59 Rev Time 0.00
Received By btrobaug Date 2007-11-08 Time 09:58 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2007-09-13 Cont ID  
Sent By btrobaug Date 2007-09-13 Time 10:09 Rev Time 0.00
Received By btrobaug Date 2007-09-13 Time 10:04 Sent To M
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2007-07-11 Cont ID  
Sent By btrobaug Date 2007-07-11 Time 06:54 Rev Time 0.00
Received By btrobaug Date 2007-07-11 Time 06:18 Sent To M
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2007-06-04 Cont ID  
Sent By btrobaug Date 2007-06-04 Time 07:19 Rev Time 0.33
Received By btrobaug Date 2007-06-04 Time 07:13 Sent To M
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2007-04-12 Cont ID  
Sent By btrobaug Date 2007-04-12 Time 12:31 Rev Time 0.50
Received By btrobaug Date 2007-04-12 Time 11:52 Sent To M
Notes
2007-04-12 12:30:57 
  
  
  
  
 210.11(C)(3) BATHROOM BRANCH CIRCUITS IN ADDITION TO
 THE NUMBER OF BRANCH CIRCUITS REQUIRED BY OTHER PARTS
 OF THIS SECTION, AT LEAST ONE 20-AMPERE BRANCH CIRCUIT
 SHALL BE PROVIDED TO SUPPLY BATHROOM RECEPTACLE
 OUTLET(S). SUCH CIRCUITS SHALL HAVE NO OTHER OUTLETS.
  
 R313.1.1 SMOKE ALARMS SHALL BE LOCATED AS REQUIRED IN
 NEW DWELLINGS WHEN REPAIRS OR ADDITIONS REQUIRING A
 PERMIT OCCUR. SEE ARTICLE FOR COMPLETE TEXT.

Review Stop I INCOMING/PROCESSING
Rev No 10 Status N Date 2008-02-26 Cont ID  
Sent By adarroug Date 2008-02-26 Time 16:44 Rev Time 0.00
Received By adarroug Date 2008-02-26 Time 16:44 Sent To Z
Notes
2008-02-26 16:44:56TO "Z" BOX/RESUB--NEW SHEETS ALL TRADES

Review Stop I INCOMING/PROCESSING
Rev No 9 Status N Date 2008-02-08 Cont ID  
Sent By adarroug Date 2008-02-08 Time 11:07 Rev Time 0.00
Received By adarroug Date 2008-02-08 Time 11:07 Sent To Z
Notes
2008-02-08 11:08:00TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 8 Status N Date 2007-11-05 Cont ID  
Sent By adarroug Date 2007-11-05 Time 11:45 Rev Time 0.00
Received By adarroug Date 2007-11-05 Time 11:45 Sent To Z
Notes
2007-11-05 11:45:46TO "Z" BOX/RESUB--NEW SHEETS ALL TRADES

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2007-09-10 Cont ID  
Sent By adarroug Date 2007-09-10 Time 09:56 Rev Time 0.00
Received By adarroug Date 2007-09-10 Time 09:56 Sent To Z
Notes
2007-09-10 09:57:04TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2007-07-10 Cont ID  
Sent By adarroug Date 2007-07-10 Time 08:44 Rev Time 0.00
Received By adarroug Date 2007-07-10 Time 08:44 Sent To E
Notes
2007-07-10 08:44:48TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2007-07-06 Cont ID  
Sent By adarroug Date 2007-07-06 Time 11:21 Rev Time 0.00
Received By adarroug Date 2007-07-06 Time 11:21 Sent To Z
Notes
2007-07-06 11:22:04TO "Z" BOX/RESUB--NEW SHEETS FOR "P" AND "Z"

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2007-06-01 Cont ID  
Sent By adarroug Date 2007-06-01 Time 08:34 Rev Time 0.00
Received By adarroug Date 2007-06-01 Time 08:34 Sent To E
Notes
2007-06-01 08:35:10TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2007-05-24 Cont ID  
Sent By adarroug Date 2007-05-24 Time 13:26 Rev Time 0.00
Received By adarroug Date 2007-05-24 Time 13:26 Sent To Z
Notes
2007-05-24 13:27:15TO "Z" BOX/RESUB--NEW SHEETS SUBMITTED

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-04-10 Cont ID  
Sent By adarroug Date 2007-04-10 Time 11:32 Rev Time 0.00
Received By adarroug Date 2007-04-10 Time 11:32 Sent To E
Notes
2007-04-10 11:33:02TO "SFR" "E"

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-04-26 Cont ID  
Sent By jgomez Date 2007-04-26 Time 07:57 Rev Time 0.00
Received By jgomez Date 2007-03-30 Time 17:20 Sent To  
Notes
2007-03-30 17:20:56TO ZONING BOX

Review Stop M MECHANICAL (A/C)
Rev No 7 Status P Date 2008-02-28 Cont ID  
Sent By tgordon Date 2008-02-28 Time 10:58 Rev Time 0.25
Received By tgordon Date 2008-02-28 Time 10:58 Sent To B
Notes
2008-02-28 10:59:40RE-STAMP. ONE BATH EXHAUST FAN AND RELOCATE CONDENSER
 UNIT.

Review Stop M MECHANICAL (A/C)
Rev No 6 Status P Date 2008-02-19 Cont ID  
Sent By tgordon Date 2008-02-19 Time 12:13 Rev Time 0.25
Received By tgordon Date 2008-02-19 Time 12:13 Sent To P
Notes
2008-02-19 12:14:24ONE BATH EXHAUST FAN AND RELOCATE CONDENSER UNIT.

Review Stop M MECHANICAL (A/C)
Rev No 5 Status F Date 2007-11-26 Cont ID  
Sent By tgordon Date 2007-11-26 Time 08:54 Rev Time 0.30
Received By tgordon Date 2007-11-26 Time 08:54 Sent To B
Notes
2007-11-26 09:07:16PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE &
 REFERENCED CODES WITH 05, 06 REVISIONS, CITY OF WEST
 PALM BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA
 ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES
 (F.S.).
  
 *** DENIED ***
 1) ENERGY CALCULATIONS NEED TO BE ON FORM600C-04R,
 "R", SEE 2004 FBC 13-600.3.C (12-8-06 REVISION).
  
 2) ENERGY CALCULATIONS LINE 9A-1 IS CALLING FOR R 4.2
 INSULATION, SEE TABLE 6C-1 ON THE SECOND PAGE OF THE
 ENERGY CALCULATIONS SUBMITTED STATES THE "MINIMUM"
 INSULATION IS TO BE R-5, SEE 2004 FBC 13-602.1.C.1.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729
 E-MAIL; [email protected]

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2007-09-13 Cont ID  
Sent By tgordon Date 2007-09-13 Time 10:56 Rev Time 0.20
Received By tgordon Date 2007-09-13 Time 10:56 Sent To P
Notes
2007-09-13 10:57:52ONE BATHROOM EXHAUST FAN AND RELOCATE A/C CONDENSER
 UNIT.

Review Stop M MECHANICAL (A/C)
Rev No 3 Status F Date 2007-07-11 Cont ID  
Sent By tgordon Date 2007-07-11 Time 09:45 Rev Time 0.25
Received By tgordon Date 2007-07-11 Time 09:45 Sent To P
Notes
2007-07-11 10:04:26*** DENIED ***
 1) COOLING LOAD CALCULATIONS WERE SUBMITTED BUT NOT
 REQUESTED. WHAT WAS REQUESTED WAS ENERGY CALCULATIONS,
 SEE 2004 FBC 13-600.ABC.3. *** PLEASE SUBMIT "ENERGY
 CALCULATIONS".
  
 ** 2004 FBC 13-600.3.ABC.3 FORMS.
 CODE COMPLIANCE BY THIS SUBCHAPTER SHALL BE
 DEMONSTRATED BY COMPLETING AND SUBMITTING TO THE
 BUILDING OFFICIAL THE APPROPRIATE FORMS DESCRIBED
 BELOW. AN ORIGINAL FORM OR FLA/RES-04, VERSION 4.5,
 COMPUTERIZED PRINTOUT, ACCOMPANIED BY A COPY OF THE
 FRONT PAGE OF THE FORM AS PROVIDED IN SECTION 600.4 ,
 SHALL BE SUBMITTED TO THE BUILDING DEPARTMENT TO
 DEMONSTRATE COMPLIANCE WITH THIS CODE BEFORE A BUILDING
 PERMIT IS ISSUED.
  
 2)SEE ATTACHED NOTICE FS 553.80(2)(B) REGARDING FOUR
 TIMES THE FEE.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2007-06-08 Cont ID  
Sent By tgordon Date 2007-06-08 Time 09:06 Rev Time 0.25
Received By tgordon Date 2007-06-08 Time 09:06 Sent To P
Notes
2007-06-08 09:21:29*** DENIED ***
 ** ENERGY CALCULATIONS NEED TO BE SUBMITTED AT TIME OF
 APPLING FOR PERMIT NOT AT A LATER DATE,SEE 2004 FBC
 13-103.2, AS REQUESTED IN LAST REVIEW 4-13-07 NOTE #1.
  
 1) PLEASE SUBMIT ENERGY CALCULATIONS FORM600C-04R,
 SEE 2004 FBC 13-101.2.2 AND 13-600.3.C (12-8-06
 REVISION).
  
 2) PLEASE KNOW WHEN SUBMITTING ENERGY CALCULATIONS THEY
 WILL NEED TO BE SIGNED BY OWNER/AGENT ALSO, PER 2004
 FBC 13-600.3.ABC.2.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2007-04-13 Cont ID  
Sent By tgordon Date 2007-04-13 Time 10:06 Rev Time 0.20
Received By tgordon Date 2007-04-13 Time 10:06 Sent To P
Notes
2007-04-13 10:23:17*** DENIED ***
 1) PLEASE SUBMIT ENERGY CALCULATIONS FORM600C-04R,
 SEE 2004 FBC 13-101.2.2 AND 13-600.3.C (12-8-06
 REVISION).
  
 2) PLEASE KNOW WHEN SUBMITTING ENERGY CALCULATIONS THEY
 WILL NEED TO BE SIGNED BY OWNER/AGENT ALSO, PER 2004
 FBC 13-600.3.ABC.2.
  
 3) BE ADVISED A MECHANICAL (A/C) PERMIT WILL BE
 REQUIRED FOR THE BATHROOM EXHAUST FAN AND RELOCATING
 THE A/C CONDENSER UNIT.
  
 4) BE ADVISED THE CLEARANCES AROUND THE A/C CONDENSER
 UNIT NEW LOCATION WILL NEED TO COMPLY WITH THE
 MANUFACTURER'S SPECIFICATIONS.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop P PLUMBING
Rev No 7 Status P Date 2008-02-28 Cont ID  
Sent By jleech Date 2008-02-28 Time 10:30 Rev Time 0.00
Received By jleech Date 2008-02-28 Time 10:28 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 6 Status P Date 2008-02-20 Cont ID  
Sent By jleech Date 2008-02-20 Time 08:33 Rev Time 0.00
Received By jleech Date 2008-02-20 Time 08:33 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 5 Status P Date 2007-11-19 Cont ID  
Sent By jleech Date 2007-11-19 Time 14:17 Rev Time 0.00
Received By jleech Date 2007-11-19 Time 14:13 Sent To M
Notes
***NONE***

Review Stop P PLUMBING
Rev No 4 Status P Date 2007-09-25 Cont ID  
Sent By jleech Date 2007-09-25 Time 13:53 Rev Time 0.00
Received By jleech Date 2007-09-25 Time 13:53 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2007-07-30 Cont ID  
Sent By jleech Date 2007-07-30 Time 07:59 Rev Time 0.00
Received By jleech Date 2007-07-30 Time 07:48 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2007-06-15 Cont ID  
Sent By jleech Date 2007-06-15 Time 08:15 Rev Time 0.00
Received By jleech Date 2007-06-15 Time 08:15 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2007-04-24 Cont ID  
Sent By jleech Date 2007-04-24 Time 09:29 Rev Time 0.00
Received By jleech Date 2007-04-24 Time 09:29 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 7 Status P Date 2008-02-27 Cont ID  
Sent By adavila Date 2008-02-27 Time 16:37 Rev Time 0.00
Received By adavila Date 2008-02-26 Time 09:08 Sent To B
Notes
2008-02-27 16:38:01PER ERIC SCHNEIDER, PRINCIPAL PLANNER.
  
 PROVISO A/C UNIT SHALL NOT ENCROACH MORE THAN 4 FEET
 INTO ANY SETBACK.

Review Stop Z ZONING
Rev No 6 Status P Date 2008-02-13 Cont ID  
Sent By adavila Date 2008-02-13 Time 09:01 Rev Time 0.00
Received By adavila Date 2008-02-12 Time 08:39 Sent To I
Notes
2008-02-13 09:01:43PER ERIC SCHNEIDER, PRINCIPAL PLANNER.
  
 PROVISO A/C UNIT SHALL NOT ENCROACH MORE THAN 4 FEET
 INTO ANY SETBACK.

Review Stop Z ZONING
Rev No 5 Status F Date 2007-11-07 Cont ID  
Sent By adavila Date 2007-11-07 Time 16:28 Rev Time 0.00
Received By adavila Date 2007-11-06 Time 16:28 Sent To I
Notes
2007-11-07 16:29:27PLANNING AND ZONING DEPARTMENT
  
 ***FAILED***
  
 1. REPEAT COMMENT FROM THE JULY 6, 2007, AND SEPTEMBER
 10, 2007, PLAN REVIEWS: ?WIDTH, DEPTH AND SETBACK
 DIMENSIONS OF THE SITE AND THE PROPOSED ADDITION SHOWN
 ON THE FLOOR, FOUNDATION AND SITE PLANS DO NOT MATCH
 THE DIMENSIONS SHOWN ON THE SURVEY.ALL PLANS SHALL
 SHOW SAME DIMENSIONS.BOTH SHEET A1 AND SURVEY NEED TO
 BE CORRECTED.?
 A. THE SITE PLAN, FOUNDATION PLAN AND FLOOR PLAN, SHOWS
 THE PROPOSED ADDITION TO BE 14 FEET WIDE BY 15 FEET
 DEEP.THE SURVEY SHOWS THE PROPOSED ADDITION TO BE 14
 FEET WIDE BY 15 FEET DEEP.
 B. THE SITE PLAN, FOUNDATION PLAN AND FLOOR PLAN, SHOWS
 THE DISTANCE SEPARATION BETWEEN THE EXISTING BUILDING
 AND THE PROPOSED ADDITION (NEW LOCATION OF THE A/C
 UNIT) TO BE 5 FEET.THE SURVEY SHOWS A DISTANCE
 SEPARATION OF 6 FEET.
 C. THE SURVEY SHOWS A LOT DEPTH OF 104.94 FEET ALONG
 THE WEST PROPERTY LINE AND 105.19 FEET ALONG THE EAST
 PROPERTY LINE.SITE PLAN SHOWS A LOT DEPTH OF 105
 FEET.
  
 2. REPEAT COMMENTS FROM THE MAY 25, 2007, PLAN REVIEW:
 ?PROPOSED ADDITION SHALL BE SHOWN ON BOTH COPIES OF
 SURVEY WITH SETBACK DIMENSIONS (REPEAT COMMENT).ALL
 SETBACK DIMENSIONS SHALL BE SHOWN ON BOTH COPIES OF
 SURVEY AND SITE PLAN.PLEASE NOTE THAT PER SECTION
 94-72 OF THE ZONING AND LAND DEVELOPMENT REGULATIONS,
 MINIMUM SIDE SETBACK IS 5 FEET, 15 FEET TOTAL.?
 A. SETBACK DIMENSIONS ARE NOT SHOWN ALONG THE WEST
 PROPERTY LINE.
 B. ACCORDING TO THE SURVEY, THE EXISTING CONCRETE
 COVERED AREA HAS A SETBACK OF LESS THAN 5 FEET
 (APPROXIMATELY 4 FEET).IN ORDER TO COMPLY WITH THE
 ZONING AND LAND DEVELOPMENT REGULATIONS, THE PROPOSED
 ADDITION SHALL BE SETBACK A MINIMUM OF 11 FEET FROM THE
 EAST PROPERTY LINE.IF THE SETBACKS CAN NOT BE MET,
 THAN A VARIANCE IS NEEDED FOR THE PROPOSED ADDITION.
 PLEASE CONTACT THE PLANNING AND ZONING DEPARTMENT FOR
 FURTHER INFORMATION REGARDING THE VARIANCE
 APPLICATION.
  
 COMMENT/QUESTIONS CONTACT ANDREINA DAVILA Q. OR ERIC
 SCHNEIDER, PRINCIPAL PLANNER, AT 822-1435.

Review Stop Z ZONING
Rev No 4 Status F Date 2007-09-12 Cont ID  
Sent By adavila Date 2007-09-12 Time 11:55 Rev Time 0.00
Received By adavila Date 2007-09-10 Time 12:23 Sent To E
Notes
2007-09-12 11:59:31PLANNING AND ZONING DEPARTMENT
  
 ***FAILED***
  
 1. WIDTH, DEPTH AND SETBACK DIMENSIONS OF THE SITE AND
 THE PROPOSED ADDITION SHOWN ON THE FLOOR, FOUNDATION
 AND SITE PLANS DO NOT MATCH THE DIMENSIONS SHOWN ON THE
 SURVEY.ALL PLANS SHALL SHOW SAME DIMENSIONS.BOTH
 SHEET A1 AND SURVEY NEED TO BE CORRECTED.
  
 COMMENTS/QUESTIONS, CONTACT ANDREINA DAVILA Q. OR ERIC
 SCHNEIDER, PRINCIPAL PLANNER, AT 822-1435.

Review Stop Z ZONING
Rev No 3 Status F Date 2007-07-09 Cont ID  
Sent By adavila Date 2007-07-09 Time 17:40 Rev Time 0.00
Received By adavila Date 2007-07-06 Time 17:07 Sent To I
Notes
2007-07-09 17:42:58PLANNING AND ZONING DEPARTMENT
  
 ***FAILED***
  
 1. WIDTH, DEPTH AND SETBACK DIMENSIONS OF THE PROPOSED
 ADDITION SHOWN ON THE FLOOR, FOUNDATION AND SITE PLANS
 DO NOT MATCH THE DIMENSIONS SHOWN ON THE SURVEY.ALL
 PLANS SHALL SHOW SAME DIMENSIONS.
  
 COMMENTS/QUESTIONS, CONTACT ANDREINA DAVILA Q. OR ERIC
 SCHNEIDER, PRINCIPAL PLANNER, AT 822-1435.

Review Stop Z ZONING
Rev No 2 Status F Date 2007-05-25 Cont ID  
Sent By adavila Date 2007-05-25 Time 11:58 Rev Time 0.00
Received By adavila Date 2007-05-24 Time 18:02 Sent To I
Notes
2007-05-25 12:03:35PLANNING AND ZONING DEPARTMENT
  
 ***FAILED***
  
 1. PROVIDE TWO (2) SIGNED AND SEALED SURVEYS.SURVEY
 SHALL BE LESS THAN A YEAR OLD (REPEAT COMMENT).
  
 2. PROPOSED ADDITION SHALL BE SHOWN ON BOTH COPIES OF
 SURVEY WITH SETBACK DIMENSIONS (REPEAT COMMENT).
  
 3. ALL SETBACK DIMENSIONS SHALL BE SHOWN ON BOTH COPIES
 OF SURVEY AND SITE PLAN.
 A. PLEASE NOTE THAT PER SECTION 94-72 OF THE ZONING AND
 LAND DEVELOPMENT REGULATIONS, MINIMUM SIDE SETBACK IS 5
 FEET, 15 FEET TOTAL.
  
 COMMENTS/QUESTIONS, CONTACT ANDREINA DAVILA Q. OR ERIC
 SCHNEIDER, PRINCIPAL PLANNER, AT 822-1435.

Review Stop Z ZONING
Rev No 1 Status F Date 2007-04-09 Cont ID  
Sent By adavila Date 2007-04-09 Time 19:56 Rev Time 0.00
Received By adavila Date 2007-04-09 Time 18:41 Sent To I
Notes
2007-04-09 19:56:52PLANNING AND ZONING DEPARTMENT
  
 ***FAILED***
  
 1. PROVIDE TWO (2) SIGNED AND SEALED SURVEYS.SURVEY
 SHALL BE LESS THAN A YEAR OLD.
  
 2. PROPOSED ADDITION SHALL BE SHOWN ON BOTH COPIES OF
 SURVEY WITH SETBACK DIMENSIONS.
  
 COMMENTS/QUESTIONS, CONTACT ANDREINA DAVILA Q. OR ERIC
 SCHNEIDER, PRINCIPAL PLANNER, AT 822-1435.