Plan Review Stops For Permit 07031012 |
Review Stop |
AD |
ADDRESSING |
Rev No |
1 |
Status |
P |
Date |
2007-05-18 |
|
|
Cont ID |
|
Sent By |
lursu |
Date |
2007-05-18 |
Time |
10:29 |
Rev Time |
0.00 |
Received By |
lursu |
Date |
2007-05-18 |
Time |
10:29 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
N |
Date |
2007-09-11 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2007-09-11 |
Time |
08:06 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2007-09-11 |
Time |
08:06 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2007-04-15 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2007-04-15 |
Time |
19:13 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2007-04-15 |
Time |
19:13 |
Sent To |
|
|
Notes |
2007-04-15 19:13:30 | REVIEW DONE UNDER 07031011 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
F |
Date |
2007-12-03 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2007-12-03 |
Time |
11:09 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2007-12-03 |
Time |
11:05 |
Sent To |
M |
|
Notes |
2007-12-03 11:09:41 | *****DENIED***** | | | | | | SEE MECHANICAL PLAN REVIEWER'S COMMENTS (REVISED PLAN | | TO BE FIRE-STAMPED WHEN MECHANICAL'S COMMENTS HAVE BEEN | | ADDRESSED) | | | | | | CAPT. MICHAEL A. WILLIAMS | | FIRE PLAN REVIEW | | 561-805-6722 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2007-09-10 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2007-09-10 |
Time |
16:04 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2007-09-10 |
Time |
15:59 |
Sent To |
M |
|
Notes |
2007-09-10 16:04:16 | *****APPROVED***** | | | | | | PLAN SHEET 1 OF 2 STAMPED, INITIALED, AND DATED. |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2007-05-17 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2007-05-17 |
Time |
13:51 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2007-05-17 |
Time |
13:43 |
Sent To |
|
|
Notes |
2007-05-17 13:50:48 | *****DENIED***** | | | | | | MASTER PERMIT (07031011) HAS NOT BEEN ISSUED; | | SUB-PERMIT (07031012) SHALL NOT BE REVIEWED UNTIL THE | | MASTER IS ISSUED. | | | | | | CAPT. MICHAEL A. WILLIAMS | | FIRE PLAN REVIEW | | 561-805-6722 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2007-12-20 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2007-12-20 |
Time |
12:32 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2007-12-20 |
Time |
12:32 |
Sent To |
|
|
Notes |
2007-12-20 12:33:02 | HOOD REVISION SENT TO "M" INBOX.ADVISED TOM GORDON. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2007-12-06 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-12-06 |
Time |
14:49 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-12-06 |
Time |
14:49 |
Sent To |
M |
|
Notes |
2007-12-06 14:53:20 | TO "M" BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2007-11-30 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-11-30 |
Time |
14:26 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-11-30 |
Time |
14:26 |
Sent To |
M |
|
Notes |
2007-11-30 14:26:44 | TO "TGORDON" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2007-09-07 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2007-09-07 |
Time |
14:56 |
Rev Time |
0.00 |
Received By |
tgordon |
Date |
2007-09-07 |
Time |
14:56 |
Sent To |
M |
|
Notes |
2007-09-07 14:56:57 | TO TOM G. DESK. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2007-05-17 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2007-05-17 |
Time |
13:43 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2007-04-02 |
Time |
17:11 |
Sent To |
|
|
Notes |
2007-04-02 17:11:14 | TO COMM BOARD # 2 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
5 |
Status |
P |
Date |
2007-12-20 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2007-12-20 |
Time |
15:09 |
Rev Time |
0.30 |
Received By |
tgordon |
Date |
2007-12-20 |
Time |
15:09 |
Sent To |
|
|
Notes |
2007-12-20 15:11:01 | REVISION TO HOOD PLANS PAGES 1 OF 2 AND 2 OF 2. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
F |
Date |
2007-12-07 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2007-12-07 |
Time |
11:09 |
Rev Time |
0.25 |
Received By |
tgordon |
Date |
2007-12-07 |
Time |
11:09 |
Sent To |
|
|
Notes |
2007-12-07 11:16:39 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM | | BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | (F.S.). | | | | ***REVISION DENIED *** | | 1) CHANGES MAY NOT BE DONE BY HAND TO ENGINEER SEALED | | PLANS. | | | | 2) THE CHANGES TO THE PLANS BY HAND DO NOT ADDRESS THE | | COMMENTS FROM THE LAST REVIEW 12-3-07 AND MAKE NO | | SENSE. PLEASE SEE NOTES FROM LAST REVIEW AND MAKE | | CORRECTIONS. | | | | ** NOTES FROM LAST REVIEW 12-3-07 ** | | 1) EXHAUST HOOD #1 HAS TWO 9"X16" EXHAUST DUCTS THE | | EXHAUST FAN IS 2,500 CFM'S , THAT WOULD PUT THE EXHAUST | | DUCT VELOCITY AT 1,250 CFM'S. SEE NOTE #4 ON PAGE 2 OF | | THE PLANS AND SEE 2004 FBC/M 506.3.4 STATES DUCT | | VELOCITY NOT LESS THAN 1,500 CFM'S. PLEASE CORRECT. | | | | 2) PAGE 1 OF PLANS FRONT ELEVATION OF HOOD #1 SHOWS THE | | EXHAUST FAN AND CURB NOT TO BE SECURED TO THE ROOF, | | PLEASE COMPLY WITH 2004 FBC 1609. | | | | 3) NEED TO ADD A FRONT VIEW FOR HOOD #2 TO THE PLANS. | | | | 4) PAGE 1 SECTION VIEW FOR HOOD #1 IS LISTING THE | | SUPPLY AND EXHAUST FANS AS #1, PLEASE CORRECT. | | | | 5) PLEASE LABEL HOODS AS #1 AND #2 ON PLAN. | | | | 6) PAGE TWO HOOD SCHEDULE SHOWS HOOD 1 EXHAUST SIZE AS | | 20X12, PLEASE CORRECT TO (2) 9X16. | | | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729 | | E-MAIL; [email protected] |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
F |
Date |
2007-12-03 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2007-12-03 |
Time |
08:26 |
Rev Time |
0.40 |
Received By |
tgordon |
Date |
2007-12-03 |
Time |
08:26 |
Sent To |
FIRE |
|
Notes |
2007-12-03 09:09:32 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM | | BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | (F.S.). | | | | ***REVISION DENIED *** | | 1) EXHAUST HOOD #1 HAS TWO 9"X16" EXHAUST DUCTS THE | | EXHAUST FAN IS 2,500 CFM'S , THAT WOULD PUT THE EXHAUST | | DUCT VELOCITY AT 1,250 CFM'S. SEE NOTE #4 ON PAGE 2 OF | | THE PLANS AND SEE 2004 FBC/M 506.3.4 STATES DUCT | | VELOCITY NOT LESS THAN 1,500 CFM'S. PLEASE CORRECT. | | | | 2) PAGE 1 OF PLANS FRONT ELEVATION OF HOOD #1 SHOWS THE | | EXHAUST FAN AND CURB NOT TO BE SECURED TO THE ROOF, | | PLEASE COMPLY WITH 2004 FBC 1609. | | | | 3) NEED TO ADD A FRONT VIEW FOR HOOD #2 TO THE PLANS. | | | | 4) PAGE 1 SECTION VIEW FOR HOOD #1 IS LISTING THE | | SUPPLY AND EXHAUST FANS AS #1, PLEASE CORRECT. | | | | 5) PLEASE LABEL HOODS AS #1 AND #2 ON PLAN. | | | | 6) PAGE TWO HOOD SCHEDULE SHOWS HOOD 1 EXHAUST SIZE AS | | 20X12, PLEASE CORRECT TO (2) 9X16. | | | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729 | | E-MAIL; [email protected] |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2007-09-11 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2007-09-11 |
Time |
08:05 |
Rev Time |
0.25 |
Received By |
tgordon |
Date |
2007-09-11 |
Time |
08:05 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2007-04-16 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2007-04-16 |
Time |
16:22 |
Rev Time |
0.45 |
Received By |
tgordon |
Date |
2007-04-16 |
Time |
16:22 |
Sent To |
|
|
Notes |
2007-04-16 16:26:24 | *** DENIED *** | | 1) MASTER PERMIT # 07031011 NEEDS TO PASS REVIEW AND | | PERMIT PRINTED BEFORE ANY SUB-PERMITS MAY BE ISSUED. | | | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
N |
Date |
2007-04-10 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2007-04-10 |
Time |
13:33 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2007-04-10 |
Time |
13:33 |
Sent To |
|
|
Notes |
|
|