Plan Review Details - Permit 07030927
Plan Review Stops For Permit 07030927
Review Stop AD ADDRESSING
Rev No 2 Status P Date 2007-08-20 Cont ID  
Sent By lursu Date 2007-08-20 Time 14:09 Rev Time 0.00
Received By lursu Date 2007-08-20 Time 14:09 Sent To  
Notes
2007-08-20 14:11:20CLARIFICATIONSRECEIVED FROM THE OWNER'S
 REPRESENTATIVE ,RICHARD MCDONALD,THAT THESE EXISTING
 UNITS 9 THUR 12 WILL BECOME ONE SINGLE UNIT .PERMIT
 APPLICATION AND TITLE BLOCK SHOULD READ 1109 OKEECHOBEE
 BLVD # 9 .
  
 LACRAMIOARA URSU
 MIS - GIS SUPPORT SPECIALIST
 CITY OF WEST PALM BEACH
 OFFICE:822-1239
 FAX: 822-1249
 E-MAIL:[email protected]

Review Stop AD ADDRESSING
Rev No 1 Status F Date 2007-08-15 Cont ID  
Sent By lursu Date 2007-08-15 Time 10:15 Rev Time 0.00
Received By lursu Date 2007-08-15 Time 10:15 Sent To  
Notes
2007-08-15 10:17:52PERMIT APPLICATION HAS UNITS 11 & 12 DESCRIBED AS WORK
 LOCATION AND SITE PLANS HAS UNIT 10 .PLEASE CLARIFY THE
 LOCATION OF WORK TO BE DONE.
  
 LACRAMIOARA URSU
 MIS - GIS SUPPORT SPECIALIST
 CITY OF WEST PALM BEACH
 OFFICE:822-1239
 FAX: 822-1249
 E-MAIL:[email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2007-11-08 Cont ID  
Sent By mjacobs Date 2007-11-08 Time 11:56 Rev Time 0.00
Received By mjacobs Date 2007-11-08 Time 11:09 Sent To PC
Notes
2007-11-08 10:56:15PROCESS PLANS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2007-10-29 Cont ID  
Sent By mjacobs Date 2007-10-29 Time 15:24 Rev Time 0.00
Received By mjacobs Date 2007-10-29 Time 15:24 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2007-08-22 Cont ID  
Sent By mjacobs Date 2007-08-22 Time 07:56 Rev Time 0.00
Received By mjacobs Date 2007-08-22 Time 06:53 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2007-06-03 Cont ID  
Sent By mjacobs Date 2007-06-03 Time 12:12 Rev Time 0.00
Received By mjacobs Date 2007-06-03 Time 10:19 Sent To  
Notes
2007-06-03 12:12:38 
 BUILDING PLAN REVIEW
 PERMIT: 07030927
 ADD: 1109 OKEECHOBEE BLVD
 CONT: RICHARD MC.DONALD CONST.
 TEL: (561)745-4736
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2006 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW 2ND
 ACTION: DENIED
  
 1)--- VERY IMPORTANT STATEMENT ---
 PLEASE DO NOT IGNORE!
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUM-
 BER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICA
 TION PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK
 YOU FOR YOUR ANTICIPATED COOPERATION.
  
 2)THE LOCATION OF THE NEW DIMISING WALL ON SHEET A2.1
 IS IN DIFFERENT LOCATION ON SHEET A3.1. THE WALL LAYOUT
 ON THE FLOOR PLAN SHALL MATCH THE CEILING PLAN.
 CLARIFY.
  
 3)SHOW IN DETAIL HOW THE NEW SINK OUTSIDE THE WOMEN'S
 BATHROOM WILL MEET THE REQUIREMENTS OF SECTION 11-4.24.
 SHOW THE CLEAR FLOOR SPACE FOR THE SINK AND THE WATER
 COOLER PER SEC. 11-4.15.5.
  
 4)FBC. 406.6.1 REPAIR GARAGES SHALL BE CONSTRUCTED IN
 ACCORDANCE WITH THE FLORIDA FIRE PREVENTION CODE AND
 THIS SECTION.
  
 5)NOTE: IF THE ADDRESS HAS BEEN CHANGED ON THE
 DRAWINGS, THEN THE INFORMATION ON THE APPLICATION SHALL
 BE ALTERED AS WELL.
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER
 805-6726
  
  
  
  
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-04-02 Cont ID  
Sent By mjacobs Date 2007-04-02 Time 07:37 Rev Time 0.00
Received By mjacobs Date 2007-04-02 Time 06:50 Sent To  
Notes
2007-04-02 07:37:17BUILDING PLAN REVIEW
 PERMIT: 07030927
 ADD: 1109 OKEECHOBEE RD
 CONT: RICHARD MC DONALD CONST.
 TEL: (561)745-4736
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2006 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW1ST
 ACTION: DENIED
  
 1)--- VERY IMPORTANT STATEMENT ---
 PLEASE DO NOT IGNORE!
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUM-
 BER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICA
 TION PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK
 YOU FOR YOUR ANTICIPATED COOPERATION.
  
 2)ALL PLANS SUBMITTED AFTER OCTOBER, 1,
 2004 SHALL BE DESIGNED TO THE 2004
 FLORIDA BUILDING CODE.
  
 3)THE NEW WATER COOLER SHALL MEET THE REQUIREMENTS OF
 FBC. 2004 SECTION 11-4.15 AND FIG.27. SUBMIT THE
 ELEVATION DRAWING OF THE WATER COOLER SHOWING ALL
 REQUIRED DIMENTIONS.
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER
 805-6726

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2007-10-27 Cont ID  
Sent By dpalmer Date 2007-10-27 Time 11:16 Rev Time 0.00
Received By dpalmer Date 2007-10-27 Time 11:16 Sent To  
Notes
2007-10-27 11:16:50 
 ** STAMPED NEW ELECTRICAL SHEETS. THE TITLE BLOCKS ON
 E-1 WERE NOT THE ONLY ITEMS REVISED.

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2007-08-12 Cont ID  
Sent By dpalmer Date 2007-08-12 Time 10:37 Rev Time 0.00
Received By dpalmer Date 2007-08-12 Time 10:24 Sent To  
Notes
2007-08-12 10:38:02 
 ** TEMPORARY FAILED STATUS **
  
  
 1) NOTE: PLANS STILL NEEDS ADDRESSING COORDINATION
 ADDED TO OUR SYSTEM AND TO PLANS. RESPONSE FROM DESIGN
 TEAM MENTIONS THIS IS TO BE UNIT #10, YET THE PERMIT
 APPLICATION, RESUB COVER SHEETS AND OUR SYSTEM STILL
 INDICATES UNITS 11 AND 12.
 PLEASE SEE THE RESPONSE ALSO PLACED THE UNIT #10 ON
 SHEET 2.1 ONLY. THE TITLE BLOCKS OF EACH PAGE NEEDS TO
 CLEARLY INDICATE THE SPECIFIC LOCATION.
 THIS CAN BE PRINTED BY HAND ONE THE FINAL LOCATION HAS
 BEEN DETERMINED WITH THE ADDRESSING REVIEWER.
 PLANS ONLY TO REMAIN TO *F* STATUS UNTIL THIS IS
 CORRECTED. ELECTRICAL PLANS ALREADY STAMPED.
  
 IF THERE ARE NAY QUESTIONS, PLEASE DO NOT HESITATE TO
 CALL.
  
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 561-805-6717

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2007-05-17 Cont ID  
Sent By dpalmer Date 2007-05-17 Time 08:24 Rev Time 0.00
Received By dpalmer Date 2007-05-17 Time 08:14 Sent To  
Notes
2007-05-17 08:25:22** UNSAT 2ND REVIEW **
  
 ** PLEASE SEE REFERENCES TO CHAPTER 1 OF THE FLORIDA
 BUILDING CODE IS THE ADMINISTRATIVE SECTION AS ADOPTED
 BY THE CITY OF WEST PALM BEACH.
  
 * PLEASE SEE SOME ITEMS FROM PREVIOUS REVIEW ARE STILL
 IN NEED OF ADDRESSING.
  
  
 1) NOTE: PLEASE SEE THE ADDRESS AS APPLIED STILL
 INDICATES UNIT/SUITES 11&12, YET PLANS NOW CALL FOR
 THIS SPACE TO BE UNIT 10? THIS WILL NEED TO BE GONE
 OVER WITH THE ADDRESSING REVIEWER AND COORDINATE FINAL
 UNIT/SUITE # AND MAKE ANY ADJUSTMENTS AS NEEDED.
  
 2) NOTE: PLEASE SEE THAT NOT ENOUGH INFORMATION WAS
 SUBMITTED FOR THE LIGHTING CONTROL PANEL. NO DETAILS,
 NO INDICATION ON OVER RIDES AND TYPES PER CHAPTER 13.
 PLEASE SEE 13-415.1.ABC.1.1 AS NO MORE THAN 30MINS IS
 PERMITTED ON OCCUPANCY TYPE DEVICES.
 PLEASE SEE PLANS CALL FOR ALL AT 4HRS WHICH IS NOT
 PERMITTED.
 PLEASE SEE NO SCHEDULING IS SHOWNON PLANS WHICH IS
 REQUIRED TO BE PART OF THE RECORD SETFOR PROPOSED
 SCOPE OF WORK.
 PLEASE SEE 13-415
  
 3) NOTE: PLEASE SEE OCCUPANCY IS NOW BEING STATED ON
 PLANS, HOWEVER EVEN AS NO PAINT SPRAY BOOTH IS SHOWN AT
 THIS TIME AND NOT MENTIONED, THE SPACE STILL FALLS
 UNDER 511 OF THE NEC.
 PLEASE SPECIFY AREAS FOR CLASS AND DIVISIONS ON PLANS.
 PLEASE INDICATE WIRING METHODS/INSTALLATIONS ETC PER
 MINIMUM REQUIREMENTS IN THE NEC.
  
 * ** IMPORTANT**
 ONCE ALL REVIEWS ARE DONE AND PLANS ARE
 PICKED UP FOR CORRECTIONS, PLEASE BE
 SURE TO COMPLETELY REMOVE ALL OLD/VOIDED
 SHEETS AND ONLY INSERT NEW REVISED
 SHEETS INTO TWO COMPLETE SETS FOR REVIEW
 AND STAMPING. DO NOT LEAVE ANY
 OLD/VOIDED SHEETS IN SETS.
 PLEASE KNOW ONLY ONE SET OF THE
 OLD/VOIDED SHEETS SHOULD BE SUBMITTED
 FOR REFERENCE.
 THIS WILL HELP IN THE REVIEW PROCESS AND
 AVOID ANY DELAYS.
  
 ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR
 COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF
 THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY,
 NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO
 NOT HESITATE IN CONTACTING THIS OFFICE AND THIS
 REVIEWER.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPT.
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2007-03-31 Cont ID  
Sent By dpalmer Date 2007-03-31 Time 08:07 Rev Time 0.00
Received By dpalmer Date 2007-03-31 Time 07:51 Sent To  
Notes
2007-03-31 08:08:14 
 ****** UNSAT *****
  
 ** PLEASE KNOW THAT ANY REFERENCE TO THE FBC CHAPTER 1
 IN THE PLAN REVIEW COMMENTS CAN BE FOUND IN THE
 ADMINISTRATIVE SECTION OF THE 2004 FBC AS ADOPTED BY
 THE CITY OF WEST PALM BEACH.
  
  
 1) NOTE: PLEASE KNOW THAT ANY PERMIT APPLICATIONS WHICH
 ARE SUBMITTED AFTER DECEMBER 8TH, 2006 PLACES PROJECTS
 UNDER THE NEW CODES ADOPTED BY THE STATE OF FLORIDA
 BUILDING COMMISSION.
 PLEASE SEE THAT THIS SHALL INCLUDE 2006 REVISIONS TO
 THE 2004 FBC FOR ALL TRADES AND THE 2005 NFPA-70.
 PLEASE KNOW THERE ARE CHANGES IN THE FBC WHICH MAY
 AFFECT DESIGNS FOR ALL TRADES. PLEASE SEE AT THIS TIME
 THE PLANS LIST A 2006 FBC IN SEVERAL LOCATIONS. THE
 STATE IS STILL UNDER THE 2004 FBC, AND ONLY ADOPTED THE
 2006 REVISIONS TO THE 2004 FBC. PLEASE ADJUST.
 PLEASE LIST THE FOLLOWING ON SHEETS FOR THIS REVIEWER
 AT A MINIMUM.
 2004 FBC W/ 2006 REVISIONS.
 2005 NFPA-70
 2003 NFPA-101
  
 2) NOTE: PLEASE STATE THE USE AND OCCUPANCY ON THIS
 SPACE/TENANT USE.
 PLEASE CLARIFY SUITE/UNIT # AS THE PLANS INDICATE TWO
 SUITE NUMBERS FOR WHAT IS BEING SHOWN AS THE SAME
 TENANT? SHOWS BOTH UNIT #11 AND #12.
  
 3) NOTE: PLEASE SEE 13-415.2 AS LIGHTING PERFORMANCE
 BASED ON THE USE IS STILL REQUIRED EVEN IF IN A NON
 CONDITIONED SPACE.
  
 4) NOTE: PLEASE CLARIFY THE PLANS WHICH INDICATE A
 LIGHTING CONTROL PANEL BEING INSTALLED WITH OVER RIDES
 HOWEVER PLANS DO NOT DETAIL THIS PANEL WITH THE OVER
 RIDE DEVICES AND THE PLANS ONLY INDICATE OCCUPANCY TYPE
 DEVICES. IF ONLY INCORPORATING OC TYPE DEVICES PLEASE
 CLARIFY.
 IF INSTALLING A LCP, PLEASE PROVIDE DETAIL/MORE
 INFORMATION FOR THIS.
 FBC 106.3.5.1.2
  
 5) NOTE: PLEASE SEE THE BATHROOMS ARE SHOWING TWO
 CIRCUITS THROUGH A SINGLE POINT OF USE FIXTURES? PLEASE
 SEE 210.4 AS ONE DEVICE BEING FED FROM MORE THAN ONE
 CIRCUIT REQUIRES THESE TO BE FED FROM A 2-POLE BREAKER.
 AS THESE ARE SHOWN ON CIRCUIT # 2 AND #6 ON PANEL
 SCHEDULE, THIS IS NOT POSSIBLE.
 PLEASE EITHER RELOCATE BRANCH BREAKERS AND PLACE ON TWO
 POLE BREAKER OR PERHAPS PLACE ON THE SAME CIRCUIT.
 FBC 106.3.5.1.2
  
 * ** IMPORTANT**
 ONCE ALL REVIEWS ARE DONE AND PLANS ARE
 PICKED UP FOR CORRECTIONS, PLEASE BE
 SURE TO COMPLETELY REMOVE ALL OLD/VOIDED
 SHEETS AND ONLY INSERT NEW REVISED
 SHEETS INTO TWO COMPLETE SETS FOR REVIEW
 AND STAMPING. DO NOT LEAVE ANY
 OLD/VOIDED SHEETS IN SETS.
 PLEASE KNOW ONLY ONE SET OF THE
 OLD/VOIDED SHEETS SHOULD BE SUBMITTED
 FOR REFERENCE.
 THIS WILL HELP IN THE REVIEW PROCESS AND
 AVOID ANY DELAYS.
  
 ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR
 COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF
 THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY,
 NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO
 NOT HESITATE IN CONTACTING THIS OFFICE AND THIS
 REVIEWER.
  
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPT.
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 4 Status N Date 2007-11-02 Cont ID  
Sent By mwennerg Date 2007-11-02 Time 15:06 Rev Time 0.00
Received By mwennerg Date 2007-11-02 Time 15:06 Sent To  
Notes
2007-11-02 15:07:50PLANS APPROVED AND STAMPED ON 8/28/07. NEW SHEET THAT
 WAS SUBMITTED STAMPED ON THIS DATE.

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2007-08-28 Cont ID  
Sent By mawillia Date 2007-08-28 Time 12:10 Rev Time 0.00
Received By mawillia Date 2007-08-28 Time 11:28 Sent To  
Notes
2007-08-28 11:56:50******APPROVED W/REMINDER*****
  
  
 IN THE TITLE BLOCK OF EACH SUBMITTED PLAN SHEET, THE
 SUITE NUMBER SHALL BE INCLUDED WITH THE NUMERICAL
 ADDRESS;PLAN SHEETS A2.1 AND E-1 WERE STAMPED,
 INITIALED, AND DATED.
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status F Date 2007-05-30 Cont ID  
Sent By mawillia Date 2007-05-30 Time 14:25 Rev Time 0.00
Received By mawillia Date 2007-05-30 Time 13:51 Sent To  
Notes
2007-05-30 14:23:40**UNSAT*****
  
 THE FOLLOWING COMMENT FROM THE PREVIOUS FIRE PLAN
 REVIEW STILL NEEDS TO BE ADDRESSED:
  
 09.WILL THE NEW DIMISING WALL IMPACT THE DISTRUBUTION
 PATTERN OF THE FIRE SPRINKLER SYSTEM?IF SO, SEPARATE
 PLANS AND PERMIT WILL BE REQUIRED FOR THE FIRE
 SPRINKLER REMODEL.
  
 NEW COMMENT
  
 1.IT APPEARS THAT THE CEILING PLAN (SHEET A3.1) IS
 NOT COMPLETE IN DETAILING SUITE/UNIT #10 AS ON OTHER
 PLAN SHEETS.
  
  
  
  
 TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE
 LETTER INDICATING HOW/WHERE (ON THE PLANS) EACH ITEM
 WAS ADDRESSED
  
  
 CAPT. MICHAEL A. WILLIAMS
 FIRE PLAN REVIEW
 561-805-6722

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2007-04-04 Cont ID  
Sent By mawillia Date 2007-04-04 Time 12:23 Rev Time 0.00
Received By mawillia Date 2007-04-04 Time 11:52 Sent To  
Notes
2007-04-04 12:19:06*****DENIED*****
  
  
 01.ON SHEET A1.0 UNDER CODE COMPLIANCE, REFERENCE (1)
 FLORIDA FIRE PREVENTION CODE 2004 EDITION(2) NFPA
 101, LIFE SAFETY CODE, 2003 EDITION.
  
 02.ON SHEET A1.0 UNDER GENERAL NOTES, NOTE #05,
 CORRECT FIRE EXTINGUISHER RATING TO 2A-10BC INSTEAD OF
 210ABC.
  
 03.THE COMPLETE ADDRESS INCLUDING THE SUITE NUMBER(S)
 OF WHERE THE SCOPE OF WORK WILL BE CONDUCTED SHALL BE
 IN THE TITLE BLOCK OF EACH SUBMITTED PLAN SHEET.
  
 04.PLEASE INDICATE EXISTING AND PROPOSED OCCUPANCY
 CLASSIFICATION FOR THIS LOCATION.
  
 05.STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR
 DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241.
  
 06.COMBUSTIBLE WASTE MATERIALS, DUST, AND DEBRIS
 SHALL BE REMOVED FROM THE SITE AT THE END OF EACH SHIFT
 OR MORE FREQUENTLY AS NECESSARY FOR SAFE OPERATION.
  
 07. THE DEMOLITION OF EXISTING AND/OR THE STOCKING OF
 NEW BUILDING SUPPLIES & MATERIALS SHALL NOT INTERFERE
 OR HINDER WITH ACCESS TO OR EGRESS FROM THE PROPERTY OR
 VICINITY THEREOF (INCLUDING STREETS, ROADS, AND FIRE
 LANES).
  
 08. OPERATIONS INVOLVING THE USE OF CUTTING AND WELDING
 SHALL BE DONE IN ACCORDANCE WITH NFPA 51B.
  
 09.WILL THE NEW DIMISING WALL IMPACT THE DISTRUBUTION
 PATTERN OF THE FIRE SPRINKLER SYSTEM?IF SO, SEPARATE
 PLANS AND PERMIT WILL BE REQUIRED FOR THE FIRE
 SPRINKLER REMODEL.
  
 10.WHEN/IF IT IS NECESSARY TO SHUT DOWN THE FIRE
 PROTECTION SYSTEM, THE FIRE DEPARTMENT WILL BE NOTIFIED
 WHEN IT IS SHUT DOWN AND WHEN IT IS RETURNED TO
 SERVICE.
  
 11.ALL REQUIRED EXIT COMPONENTS WITHIN THE STRUCTURE
 SHALL BE MAINTAINED.
  
  
 TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE
 LETTER INDICATING HOW/WHERE (ON THE PLANS) EACH ITEM
 WAS ADDRESSED
  
  
 CAPT. MICHAEL A. WILLIAMS
 FIRE PLAN REVIEW
 561-805-6722

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2007-10-19 Cont ID  
Sent By adarroug Date 2007-10-19 Time 16:25 Rev Time 0.00
Received By adarroug Date 2007-10-19 Time 16:25 Sent To  
Notes
2007-10-27 11:09:35TO BOB BOARD SPACE #5. DVP
2007-10-19 16:25:48WAITING FOR "BOB"

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2007-08-10 Cont ID  
Sent By dpalmer Date 2007-08-10 Time 08:33 Rev Time 0.00
Received By dpalmer Date 2007-08-10 Time 08:32 Sent To  
Notes
2007-08-10 08:33:22TO BOB BOARD #4

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2007-08-02 Cont ID  
Sent By adarroug Date 2007-08-02 Time 16:37 Rev Time 0.00
Received By adarroug Date 2007-08-02 Time 16:37 Sent To  
Notes
2007-08-02 16:38:00WAITING FOR "BOB"

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-05-14 Cont ID  
Sent By adarroug Date 2007-05-14 Time 15:14 Rev Time 0.00
Received By adarroug Date 2007-05-14 Time 15:14 Sent To  
Notes
2007-05-14 15:15:13TO "BOB"#6

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-04-04 Cont ID  
Sent By mawillia Date 2007-04-04 Time 11:53 Rev Time 0.00
Received By mawillia Date 2007-03-27 Time 18:23 Sent To  
Notes
2007-03-27 18:23:34TO BOB # 9

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2007-10-31 Cont ID  
Sent By tgordon Date 2007-10-31 Time 16:14 Rev Time 0.45
Received By tgordon Date 2007-10-31 Time 16:14 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2007-08-30 Cont ID  
Sent By tgordon Date 2007-08-30 Time 11:38 Rev Time 0.45
Received By tgordon Date 2007-08-30 Time 11:38 Sent To  
Notes
2007-08-30 12:27:25PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE &
 REFERENCED CODES WITH 05, 06 REVISIONS, CITY OF WEST
 PALM BEACH AMENDMENTS TO CHAPTER 1 (WPB), FLORIDA
 ADMINISTRATIVE CODE (FAC), AND FLORIDA STATUTES (FS).
  
 *** DENIED ***
 1) PLEASE ADJUST THE VALUE OF THE JOB ON THE
 APPLICATION AS THE WORK IS NOW TO INCLUDE A BUILDING
 EXHAUST SYSTEM, SEE WPB 108.3.
  
 2) THE EXHAUST SYSTEM APPEARS TO DISCHARGE AT THE
 ENTRANCE OF THE BUILDING, PER FBC/MECH. 501.2 OUTDOOR
 DISCHARGE. THE AIR REMOVED BY EVERY MECHANICAL EXHAUST
 SYSTEM SHALL BE DISCHARGED OUTDOORS AT A POINT WHERE IT
 WILL NOT CAUSE A NUISANCE AND FROM WHICH IT CANNOT
 AGAIN BE READILY DRAWN IN BY A VENTILATING SYSTEM.. THE
 DOOR OPENINGS ARE A PART OF THE NATURAL MEANS OF
 VENTILATION TO THE BUILDING. ADJUST DISCHARGE LOCATION
 SO IT WILL NOT BE A NUISANCE AND MAY NOT RE-ENTER THE
 BUILDING.
  
 3) PLEASE STATE ON PLANS WHAT TYPE OF HAZARD IS BEING
 EXHAUSTED IF ANY BY THIS SYSTEM. SEE FBC/MECH. 510.1.
  
 4) PLEASE ADD A HANGING DETAIL FOR THE DUCT TO THE
 MECHANICAL PLAN.
  
 5) MECHANICAL PLAN PAGE M-1 NOTE #1 STATES "ALL EXHAUST
 DUCTS SHALL RUN CONTINUOUSLY". IF THE DOORS ARE CLOSED
 AT NIGHT AND THE EXHAUST FANS ARE RUNNING WERE WILL THE
 MAKE-UP AIR COME FROM? PLEASE SHOW ON PLAN.
  
 6) NOTE #2 ON PAGE M-1 STATES "IT IS IN VIOLATION OF
 CODE TO TURN OFF EXHAUST FANS". PLEASE SHOW THE CODE
 THAT APPLIES TO AIDE IN THIS REVIEW
  
 7)PLEASE SUBMIT DETAILED MANUFACTURER'S
 SPECIFICATION'S AND INSTALLATION INSTRUCTIONS FOR THE
 EXHAUST FANS AND THE BACKDRAFT DAMPERS, SEE
 FBC/MECH.401.6.
  
 8) PLEASE ADD A DETAIL TO THE PLANS FOR THE GALV.
 WEATHER HOOD FOR THE EXHAUST FANS, SHOWING HOW IT
 SHOULD BE ANCHORED TO COMPLY WITH FBC 1609.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729
 E-MAIL; [email protected]

Review Stop P PLUMBING
Rev No 4 Status P Date 2007-11-08 Cont ID  
Sent By jleech Date 2007-11-08 Time 08:01 Rev Time 0.00
Received By jleech Date 2007-11-08 Time 08:01 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status F Date 2007-08-27 Cont ID  
Sent By mperson Date 2007-08-27 Time 14:26 Rev Time 0.00
Received By mperson Date 2007-08-27 Time 14:26 Sent To  
Notes
2007-08-27 15:20:21DENIED 3RD TIME
 REFERENCE:
 ** FBC-2004 PLUMBING.
 ** FBC-2004 CHAPTER 1, THE CITY OF
 WEST PALM BEACH AMENDMENTS.
 ** FLORIDA ADMINISTRATIVE CODE.
 ** FLORIDA STATUTES.
  
 ** PLEASE SEE SOME NOTES FROM PREVIOUS REVIEW ARE STILL
 IN NEED OF ADDRESSING ALONG WITH SOME NEW COMMENTS,
 SOME BASED ON PLANS NOW SUBMITTED, NEW DOCUMENTS BEING
 REVIEWED FOR THE FIRST TIME AND SOME NEW COMMENTS NOT
 MADE ON PREVIOUS REVIEWS.
  
 ** PLEASE SEE THE NOTES BELOW ARE TAKEN DIRECTLY FROM
 PREVIOUS REVIEW WITH A NO, OK OR A NO/OK.
 THESE WILL BE FOR THE EXACT NUMERICAL NOTATION OF THE
 PREVIOUS REVIEW NOTES.
  
 A NO IS IF THE COMMENT WAS NOT FULLY ADDRESSED AND/OR
 FURTHER EXPLANATION OR CHANGES IN PLANS OR DOCUMENTS
 ARE STILL NEEDED. THIS REVIEWER WILL TRY TO BETTER
 EXPLAIN NOTE ABOVE PREVIOUS REVIEW COMMENT.
  
 AN OK WILL BE LABELED AS SUCH ON THE SAME NUMERICAL
 COMMENT AND WILL HAVE OLD NOTE REMOVED FROM COMMENTS.
  
 A NO/OK MEANS PART OF THE COMMENT MAY HAVE BEEN
 ADDRESSED, HOWEVER NOT ALL OF THE PREVIOUS REVIEW
 COMMENT MAY HAVE BEEN FULLY ADDRESSED.
  
 ** PLEASE SEE ANY NEW NOTES WILL BE ADDED TO THE END OF
 THE PREVIOUS REVIEW COMMENTS AND NOTED AS SUCH.
  
 1. **OK**
  
 2. **OK**
  
 3. **OK**
  
 THE FOLLOWING ARE NEW COMMENTS:
  
 4. SHEET A-2 ELEVATION DETAIL FOR THE DRINKING
 FOUNTAIN: THE ELEVATION DETAIL OF THE DRINKING FOUNTAIN
 DOES NOT INDICATE COMPLIANCE TO 11-4.3(10)(A) WHERE
 ONLY ONE DRINKING FOUNTAIN IS PROVIDED THERE SHALL BE A
 DRINKING FOUNTAIN WHICH IS ACCESSIBLE TO INDIVIDUALS
 WHO USE WHEELCHAIRS IN ACCORDANCE TO 11-4.15 AND ONE
 ACCESSIBLE TO THOSE WHO HAVE DIFFICULTY BENDING OR
 STOOPING; OR BY SUCH OTHER MEANS AS WOULD ACHIEVE THE
 REQUIRED ACCESSIBILITY FOR EACH GROUP.
  
 5. SHEET A2.1 AND P-1 THE EMERGENCY SHOWER AND
 EYEWASH: PER FBC-2004 PLUMBING SECTION 411.2 WASTE
 CONNECTIONS SHALL NOT BE REQUIRED FOR EMERGENCY SHOWERS
 AND EYEWASH STATIONS. THE RESUBMITTED PLANS ARE
 INDICATING A 150/GAL NEUTRALIZATION TANK BEING
 INSTALLED WITH THIS EMERGENCY SHOWER AND EYEWASH
 STATION. PLEASE CLARIFY WHY THIS IS REQUIRED. ARE THERE
 CHEMICALS INVOLVED? IF THERE ARE CHEMICALS INVOVED WHAT
 ARE THEY?
 NOTE:PER FBC-2004 PLUMBING SECTION 301.3 CONNECTIONS TO
 THE SANITARY DRAINAGE SYSTEM. ALL PLUMBING FIXTURES,
 DRAINS, APPURTENANCES AND APPLIANCES USED TO RECIEVE OR
 DISCHARGE LIQUID WASTES (NEUTRALIZATION TANK) OR SEWAGE
 SHALL BE DIRECTLY CONNECTED TO THE SANITARY DRAINAGE
 SYSTEM OF THE BUILDING OR PREMISES.
  
 END OF COMMENTS:
  
 REVIEW BY MIKE PERSON
 PLUMBING PLANS EXAMINER
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL= [email protected]
  
  

Review Stop P PLUMBING
Rev No 2 Status F Date 2007-06-04 Cont ID  
Sent By jleech Date 2007-06-04 Time 09:16 Rev Time 0.00
Received By jleech Date 2007-06-04 Time 09:16 Sent To  
Notes
2007-06-04 09:59:38DENIED;
 1.EMERGENCY EYE WASH AND SHOWER SHALL COMPLY WITH
 ISEA-Z358.1, PER SECTION 411.1 OF THE FBC PLUMBING
 CODE. SEND IN MANUFACTURE'S CUT SHEET THAT SHOWS
 COMPLIANCE TO ISEA STANDARDS.
 2. WATER RISER DIAGRAM; SHUT OFF VALVE REQUIRED FOR BAY
 10. WATER SUPPLY FOR EYE WASH AND EMERGENCY SHOWER ARE
 NOT SHOWN. WATER SUPPLY TO MEET MANUFACTURE
 INSTRUCTIONS.
 3.SERVICE SINK REQUIRES HOT WATER FOR BUILDING
 MAINTENANCE. SECTION 607.1
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695

Review Stop P PLUMBING
Rev No 1 Status F Date 2007-03-31 Cont ID  
Sent By jleech Date 2007-03-31 Time 10:17 Rev Time 0.00
Received By jleech Date 2007-03-31 Time 10:17 Sent To  
Notes
2007-03-31 10:32:05DENIED;
 CODE REFERENCE TO BE 2004 WITH 2006 AMENDMENTS.
 FBC-2004 PLUMBING TABLE 403.1 8 S-1, S-2 A SERVICE SINK
 IS REQUIRED.
 SHOW WHAT MATERIALS WILL BE STORED. A EMERGENCY SHOWER
 AND EYE WASH MAY BE REQUIRED.
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695

Review Stop Z ZONING
Rev No 1 Status N Date 2007-08-10 Cont ID  
Sent By choops Date 2007-08-10 Time 08:44 Rev Time 0.00
Received By choops Date 2007-08-10 Time 08:44 Sent To  
Notes
2007-08-10 08:44:26*VALUE OF PROPOSED WORK DOES NOT EXCEED 50% OF THE
 IMPROVEMENT VALUE.