Plan Review Details - Permit 07030890
Plan Review Stops For Permit 07030890 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2007-05-01 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-05-01 |
Time |
17:57 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-05-01 |
Time |
17:57 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2007-04-07 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-04-07 |
Time |
12:56 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-04-07 |
Time |
12:56 |
Sent To |
|
|
Notes |
2007-04-07 12:58:44 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBCFLORIDA BUILDING CODE 2004 | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | CODE | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC* | | CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 FAC | | FLORIDA ADMINISTRATIVE CODE | | FSFLORIDA STATUTE | | | | | | 1.)PROVIDE CALCULATIONS FOR THE CORNER AND PERIMETER | | FASTENING SHOWING VALUE PER FASTENER PER SQUARE.THIS | | WILL INCLUDE THE ROW AT THE LAP AS WELL AS THE FIELD | | ROWS. | | | | IT IS NOT CLEAR WHETHER THE ROW FASTENING IS COMPLIANT | | AS THEY WERE NOT ENHANCED IN THE SAME PROPORTION AS THE | | FIELD ROWS, BUT THE RAS117 TAKES ALL ROWS INTO ACCOUNT, | | NOT ONLY THE FIELD.THEREFORE, PROVIDE CALCULATIONS | | SHOWING THAT THE VALUE PER FASTENER EXCEEDS THE VALUE | | REQUIRED TO MEET THE PRESSURES SPECIFIED. | | | | 2.)PROVIDE SPECS FROM THE MANUFACTURER FOR THE BASE | | SHEET SPECIFIED.NOTE THAT THE NOA DOES NOT INCLUDE | | INFORMATION ON PRODUCTS THAT ARE NOT MANUFACTURED BY | | POLYGLASS.THE FIRST SET OF ENGINEERING STATED THAT | | THE SHEET HAD A 31INCH WIDTH, THIS ONE STATES THAT IT | | IS 36INCHES.TO MY KNOWLEDGE THIS HAS ALWAYS HAD A | | 39.4" SHEET WIDTH.PLEASE PROVIDE SPECIFICATIONS | | SHOWING THE 36" WIDTH AS REQUESTED. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2007-03-26 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-03-26 |
Time |
16:19 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-03-26 |
Time |
16:00 |
Sent To |
|
|
Notes |
2007-03-26 16:28:13 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBCFLORIDA BUILDING CODE 2004 | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | CODE | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL | | FBC*CITY OF WEST PALM BEACH AMENDMENTS TO THE | | FBC2004 | | FACFLORIDA ADMINISTRATIVE CODE | | FSFLORIDA STATUTE | | | | 1.)THE NAME OF THE ENGINEERING FIRM DOES NOT MATCH | | THE CERTIFICATE OF AUTHORIZATION ("BUCK ENGINEERING" | | RATHER THAN "BUCK ENGINEERING INC."). | | | | 2.)FBC35, ASCE7-02 IS TO BE USED RATHER THAN | | ASCE7-05. | | | | 3.)PROVIDE MANUFACTURER SPEC SHEETS FOR THE BASE | | SHEET.BASE SHEET WIDTH OF -31.11502 IS SPECIFIED BY | | THE ENGINEER. | | | | 4.)PROVIDE CALCULATIONS IN ACCORDANCE WITH RAS117. | | | | 5.)YOU HAVE SPECIFIED BASE SHEET FASTENING IN | | FRACTIONS OF INCHES.ALL SPACING IS TO BE ROUNDED | | DOWN, SEE RAS117 10.4.2. | | | | 6.)CONTRACTOR IS TO SELECT METHOD OF INSTALLATION FOR | | THE METAL ROOF. | | |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
P |
Date |
2007-03-26 |
|
|
Cont ID |
|
Sent By |
swurafti |
Date |
2007-03-26 |
Time |
10:51 |
Rev Time |
0.00 |
Received By |
swurafti |
Date |
2007-03-26 |
Time |
10:51 |
Sent To |
|
|
Notes |
2007-03-26 10:52:17 | HISTORIC APPROVED BY GJUDGE |
|
|
|
Account Summary | Usage Policy | Privacy Policy