Plan Review Details - Permit 07030852
Plan Review Stops For Permit 07030852
Review Stop B BUILDING (STRUCTURAL)
Rev No 8 Status P Date 2007-11-20 Cont ID  
Sent By jwitmer Date 2007-11-20 Time 10:29 Rev Time 2.33
Received By jwitmer Date 2007-11-20 Time 10:29 Sent To  
Notes
2007-11-20 10:30:08REVISIONS: S101, S201 & S202
 T100,T101, LS101,LS102,
 A101,A102,A103,A104,
 A201,A202,A204,A205,A206,A208,
 A501,A502,A505,A601, F101,F102

Review Stop B BUILDING (STRUCTURAL)
Rev No 7 Status P Date 2007-10-31 Cont ID  
Sent By jjohnsto Date 2007-10-31 Time 09:38 Rev Time 0.00
Received By jjohnsto Date 2007-10-31 Time 09:37 Sent To  
Notes
2007-10-31 09:38:01FIRE STOP REVISION REVIEWED FOR COMPLIANCE

Review Stop B BUILDING (STRUCTURAL)
Rev No 6 Status P Date 2007-10-30 Cont ID  
Sent By jwitmer Date 2007-10-30 Time 08:12 Rev Time 0.00
Received By jwitmer Date 2007-10-30 Time 08:12 Sent To  
Notes
2007-10-30 08:14:23REVISION: REVIEWED

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2007-10-17 Cont ID  
Sent By jwitmer Date 2007-10-17 Time 11:46 Rev Time 2.22
Received By jwitmer Date   Time   Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2007-08-23 Cont ID  
Sent By jjohnsto Date 2007-08-23 Time 09:45 Rev Time 3.00
Received By jjohnsto Date 2007-08-23 Time 09:45 Sent To PC
Notes
2007-08-23 10:03:06 
 *** ISSUED PERMIT***
 -PLAN REVIEW HISTORY-
  
 PERMIT#07030852
 ADDRESS:651OKEECHOBEEBLVD,SUITE 100
 CONT: RCC & ASSOCIATES, INC
 TELL #(561)856-6655
  
 THE ATTACHED COMMENTS ARE PART OF THE
 PERMIT AND PLAN REVIEW PACKAGE AND ARE
 NOT TO BE REMOVED FROM THE ISSUED SET OF PLANS.106.1.1
 ADMINISTRATIVE CODE/ 06.
  
 BUILDING PROVISO:
 ) 109.3.10.1 HURRICANE PROTECTION.
 IT SHALL BE UNLAWFUL FOR ANY PERSON TO
 ALLOW CONSTRUCTION RELATED MATERIALS
 EQUIPMENT AND DEBRIS TO REMAIN LOOSE OR
 OTHERWISE UNSECURED AT A CONSTRUCTION
 SITE FROM 24 HRS. AFTER A HURRICANE
 WATCH HAS BEEN ISSUED UNTIL THE
 HURRICANE WATCH OR WARNING HAS BEEN
 LIFTED. ALL SUCH CONSTRUCTION MATERIALS,
 EQUIPMENT AND DEBRIS SHALL BE EITHER
 REMOVED FROM THE CONSTRUCTION SITE OR
 SECURED IN SUCH A MANNER AS TO MINIMIZE
 THE DANGER OF SUCH CONSTRUCTION
 MATERIALS, EQUIPMENT AND DEBRIS CAUSING
 DAMAGE TO PERSONS OR PROPERTY FROM HIGH
 WINDS.
 ANY PERSONS WHO FAILS TO COMPLY TO
 REMOVE OR SECURE THE CONSTRUCTION
 MATERIALS EQUIPMENT AND DEBRIS WITHIN
 24 HRS AFTER A HURRICANE WATCH HAS BEEN
 ISSUED SHALL BE SUBJECT TO A FINE NOT TO
 EXCEED $500.00.
 IN ADDITION TO THE ABOVE, A LICENSED
 CONTRACTOR WHO VIOLATES THIS SECTION
 SHALL BE SUBJECT TO DISCIPLINE PURSUANT
 TO SECTION 113 OF THIS CHAPTER.
  
 BUILDING PLAN REVIEW II
 JAMES JOHNSTON
 TEL:561- 805 - 6716
 FAX:561- 805 - 6731
 [email protected]
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2007-08-02 Cont ID  
Sent By jwitmer Date 2007-08-02 Time 15:32 Rev Time 1.55
Received By jwitmer Date 2007-08-02 Time 13:42 Sent To  
Notes
2007-08-02 15:37:43BUILDING PLAN REVIEW
 PERMIT: 07030852
 ADD: 651 OKEECHOBEE BLVD# 100
 CONT: RCC ASSOCIATES, INC
 TEL: (954)691-5385
 FBC = 2004 FLORIDA BUILDING CODE
 W/ 2006 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 2NDREVIEW
 ACTION: DENIED
  
 1)--- VERY IMPORTANT STATEMENT ---
 PLEASE DO NOT IGNORE!
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUM-
 BER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICA
 TION PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK
 YOU FOR YOUR ANTICIPATED COOPERATION.
  
 2) FL S S 713.13
 NOTICE OF COMMENCEMENT, TO BE FILED WITH THE CLERK OF
 THE COURT.
 NOTE: 713.13(2)
 IF THE WORK DESCRIBED IN THE NOTICE OFCOMMENCEMENT IS
 NOT
 ACTUALLYCOMMENCED WITHIN 90 DAYS AFTER THE RECORDING
 THEREOF,
 SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6)THE
 POSTING OF THE
 NOTICE OF COMMENCEMENT AT THE CONSTRUCTION SITE BEFORE
 THE
 FIRST INSPECTION.
  
 3) PLEASE SEE ELECTRICAL COMENTS ABOUT RUBBER OR
 STAMPED SIGNATURES.
 PLANS, SPECIFICATIONS, REPORTS OR
 OTHER DOCUMENTS PREPARED BY THE DESIGN PROFESSIONAL AND
 BEING FILED FOR PUBLIC
 RECORD SHALL HAVE THE SIGNATURE AND
 SEAL OF THE DESIGN PROFESSIONAL AFFIXED
 TO THE DOCUMENT.
 FL STATE STAT: 61G15-23.002 ENGINEERS
 FL ATATE STAT: 61G16.003 ARCHITECTS
  
 4) PLANS APPEAR TO BE CODE COMPLIANT, PLANS NEED TO BE
 ORGANIZED (STAPLED) INTO SETS,ONCE THE SHEETS IN
 QUESTION ARE RESUBMITTED WITH ORIGINAL SIGNATURES
 BUILDING WILL BE OK.
  
 BUILDING PLAN REVIEW II
 JIM WITMER C. B. O.
  
 TEL: (561)805-6715
 FAX: (561)659-8026
 E-MAIL: [email protected]
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2007-06-07 Cont ID  
Sent By jwitmer Date 2007-06-07 Time 08:54 Rev Time 6.75
Received By jwitmer Date 2007-06-06 Time 17:21 Sent To  
Notes
2007-06-07 08:54:28BUILDING PLAN REVIEW
 PERMIT: 07030852
 ADD: 651 OKEECHOBEE BLVD# 100
 CONT: RCC ASSOCIATES, INC
 TEL: (954)691-5385
 FBC = 2004 FLORIDA BUILDING CODE
 W/ 2006 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 2NDREVIEW
 ACTION: DENIED
  
 1)--- VERY IMPORTANT STATEMENT ---
 PLEASE DO NOT IGNORE!
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUM-
 BER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICA
 TION PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK
 YOU FOR YOUR ANTICIPATED COOPERATION.
  
 2) FL S S 713.13
 NOTICE OF COMMENCEMENT, TO BE FILED WITH THE CLERK OF
 THE COURT.
 NOTE: 713.13(2)
 IF THE WORK DESCRIBED IN THE NOTICE OFCOMMENCEMENT IS
 NOT
 ACTUALLYCOMMENCED WITHIN 90 DAYS AFTER THE RECORDING
 THEREOF,
 SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6)THE
 POSTING OF THE
 NOTICE OF COMMENCEMENT AT THE CONSTRUCTION SITE BEFORE
 THE
 FIRST INSPECTION.
  
 3-9 ) COMPLIED.
  
 10 2ND REQUEST, 10) SHEET A201- A205 INDICATE TYPE OF
 WALL FINISHES, THEY INCLUDE WALL COVERINGS, GLASS,
 METAL LAMINATES, PANEL FABRIC, WALL PANEL & WOOD
 VENEERS, PLEASE PROVIDE THE FLAME SPREAD INDEX AND
 SMOKE DEVELOPMENT INDEX FOR EACH OF THE MATERIALS TO BE
 INSTALLED. SEE TABLE 803.5 PLEASE TAKE NOTE OF
 FOOTNOTES A, B, AND C.
 THESE ARE WALL FINISHES THAT DO NOT PROVIDE A FLAME
 SPREAD RATING:
 10A) WV-01 BRAEWOOD PREFINISHED VENEERS
 10B) WV-02 FORMICA CORDIAL CHERRY BIRDSEVE
 10C) WV-03 FORMICA KOFFE FINELINE
 10D) PF-03 PERFORMANCE SUEDE
 10E) BLAIRP 5-6 LEATHERED PLISSE ESPRESSO UPHOLSTERY
  
 11) TEXTILES;803.6 TEXTILES. WHERE USED AS INTERIOR
 WALL OR CEILING FINISH MATERIALS, TEXTILES, INCLUDING
 MATERIALS HAVING WOVEN OR NONWOVEN, NAPPED, TUFTED,
 LOOPED OR SIMILAR SURFACE, SHALL COMPLY WITH THE
 REQUIREMENTS OF THIS SECTION.
  
 803.6.1 TEXTILE WALL COVERINGS.
 TEXTILE WALL COVERINGS SHALL HAVE A CLASS A FLAME
 SPREAD INDEX IN ACCORDANCE WITH ASTM E 84 AND BE
 PROTECTED BY AUTOMATIC SPRINKLERS INSTALLED IN
 ACCORDANCE WITH SECTION 903.3.1.1 OR 903.3.1.2 OR THE
 COVERING SHALL MEET THE CRITERIA OF SECTION 803.6.1.1
 OR 803.6.1.2 WHEN TESTED IN THE MANNER INTENDED FOR USE
 IN ACCORDANCE WITH NFPA 265 USING THE PRODUCT MOUNTING
 SYSTEM, INCLUDING ADHESIVE.
  
 803.6.1.1 METHOD A TEST PROTOCOL.
 DURING THE METHOD A PROTOCOL, FLAME SHALL NOT SPREAD TO
 THE CEILING DURING THE 40 KW EXPOSURE. DURING THE 150
 KW EXPOSURE, THE TEXTILE WALL COVERING SHALL COMPLY
 WITH ALL OF THE FOLLOWING:
 1.FLAME SHALL NOT SPREAD TO THE OUTER EXTREMITY OF
 THE SAMPLE ON THE 8-FOOT BY 12-FOOT (203 MM BY 305 MM)
 WALL.
 2.THE SPECIMEN SHALL NOT BURN TO THE OUTER
 EXTREMITY OF THE 2-FOOT-WIDE (610 MM) SAMPLES MOUNTED
 IN THE CORNER OF THE ROOM.
 3.BURNING DROPLETS DEEMED CAPABLE OF IGNITING
 TEXTILE WALL COVERINGS OR THAT BURN FOR 30 SECONDS OR
 MORE SHALL NOT FORM.
 4.FLASHOVER, AS DEFINED IN NFPA 265, SHALL NOT
 OCCUR.
 5.THE MAXIMUM NET INSTANTANEOUS PEAK HEAT RELEASE
 RATE, DETERMINED BY SUBTRACTING THE BURNER OUTPUT FROM
 THE MAXIMUM HEAT RELEASE RATE, DOES NOT EXCEED 300 KW.
  
  
 803.6.1.2 METHOD B TEST PROTOCOL.
 DURING THE METHOD B PROTOCOL, FLAMES SHALL NOT SPREAD
 TO THE CEILING AT ANY TIME DURING THE 40 KW EXPOSURE.
 DURING THE 150 KW EXPOSURE, THE TEXTILE WALL COVERING
 SHALL COMPLY WITH THE FOLLOWING:
 1.FLAME SHALL NOT SPREAD TO THE OUTER EXTREMITIES
 OF THE SAMPLES ON THE 8-FOOT BY 12-FOOT (203 MM BY 305
 MM) WALLS.
 2.FLASHOVER, AS DESCRIBED IN NFPA 265, SHALL NOT
 OCCUR.
  
 803.6.2 TEXTILE CEILING FINISH.
 WHERE USED AS A CEILING FINISH, CARPET AND SIMILAR
 TEXTILE MATERIALS SHALL HAVE A CLASS A FLAME SPREAD
 INDEX IN ACCORDANCE WITH ASTM E 84 AND BE PROTECTED BY
 AUTOMATIC SPRINKLERS.
  
 12) COMPLIED.
  
 13) 2ND REQUEST,805.5 TRIM. MATERIAL USED AS INTERIOR
 TRIM SHALL HAVE A MINIMUM CLASS C FLAME SPREAD INDEX
 AND SMOKE-DEVELOPED INDEX. COMBUSTIBLE TRIM, EXCLUDING
 HANDRAILS AND GUARDRAILS, SHALL NOT EXCEED 10 PERCENT
 OF THE AGGREGATE WALL OR CEILING AREA IN WHICH IT IS
 LOCATED.
 PLEASE PROVIDE THE PER-CENTAGES THAT THE VENEERS AND
 COMBUSTIBLE WOOD TRIM CONTRIBUTE FOR EACH WALL. 805.5
 INDICATES THAT EACH OF THESE MATERIALS SHALL HAVE A
 MINIMUM FLAME SPREAD RATING OF C" ANDSHALL NOT EXCEED
 10 PERCENT OF THE AGGREGATE WALL OR CEILING AREA IN
 WHICH IT IS LOCATED.
  
 A THOROUGH REVIEW CAN NOT BE MADE AT THIS TIME, AS A
 RESULT OF THE ADDITIONAL
 INFORMATION REQUESTED ADDITIONAL COMMENTS MAY APPEAR
 THAT WERE NOT PART OF THIS REVIEW.
  
 BUILDING PLAN REVIEW
 JIM WITMER C. B. O.
  
 TEL: (561)805-6715
 FAX: (561)659-8026
 E-MAIL: [email protected]
  
  
  
  
 )

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-05-16 Cont ID  
Sent By jwitmer Date 2007-05-16 Time 17:19 Rev Time 3.33
Received By jwitmer Date 2007-05-15 Time 16:45 Sent To  
Notes
2007-05-16 09:24:29BUILDING PLAN REVIEW
 PERMIT: 07030852
 ADD: 651 OKEECHOBEE BLVD# 100
 CONT: RCC ASSOCIATES, INC
 TEL: (954)691-5385
 FBC = 2004 FLORIDA BUILDING CODE
 W/ 2006 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW
 ACTION: DENIED
  
 1)--- VERY IMPORTANT STATEMENT ---
 PLEASE DO NOT IGNORE!
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUM-
 BER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICA
 TION PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK
 YOU FOR YOUR ANTICIPATED COOPERATION.
  
 2) FL S S 713.13
 NOTICE OF COMMENCEMENT, TO BE FILED WITH THE CLERK OF
 THE COURT.
 NOTE: 713.13(2)
 IF THE WORK DESCRIBED IN THE NOTICE OFCOMMENCEMENT IS
 NOT
 ACTUALLYCOMMENCED WITHIN 90 DAYS AFTER THE RECORDING
 THEREOF,
 SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6)THE
 POSTING OF THE
 NOTICE OF COMMENCEMENT AT THE CONSTRUCTION SITE BEFORE
 THE
 FIRST INSPECTION.
  
 3) SHEET T-101, APPLICABLE CODES- THE 2001
 ACCESSIBILITY CODE IS THE WRONG CODE PLEASE CORRECT TO
 THE 2004 FBC CHAPTER 11FLORIDA ACCESSIBILITY CODE
  
 4) SHEET T-101, APPLICABLE CODES- PREVIOUS OCCUPANCY
 WAS ALSO A RESTAURANT: A2 OCCUPANCY
  
 5) SHEET T-101, CONSTRUCTION TYPE: THIS IS A HIGH RISE
 BUILDING REQUIRING TYPE IA CONSTRUCTION.
  
 6) IN THE SEET OF PLANSREVIEWED THE DESIGNER OF
 RECORD MISSED SIGNING AND SEALING THE T, LS ANDQUITE
 A FEW A SHEETS.
 PLANS, SPECIFICATIONS, REPORTS OR
 OTHER DOCUMENTS PREPARED BY THE DESIGN PROFESSIONAL AND
 BEING FILED FOR PUBLIC
 RECORD SHALL HAVE THE SIGNATURE AND
 SEAL OF THE DESIGN PROFESSIONAL AFFIXED
 TO THE DOCUMENT.
 FL STATE STAT: 61G15-23.002 ENGINEERS
 FL ATATE STAT: 61G16.003 ARCHITECTS
  
 7)VOA ASSOCIATES INCORP. DOESN'T INDICATE THEIR
 CERTIFICATE OF AUTHORIZATION.
 481.219 F.S.CERTIFICATE OF
 AUTHORIZATION.THE TITLE BLOCK FOR ANY
 SHEET BEARING THE NAME OF AN ARCHITECT
 PRACTICING UNDER A FICTITIOUS NAME, A
 CORPORATION, OR A PARTNERSHIP, OFFERING ARCHITECTURAL
 SERVICES, SHALL INCLUDE
 THE CERTIFICATE OF AUTHORIZATION
 NUMBER.ADD THE NUMBER TO EACH SHEET.
 THIS MAY BE ADDED BY HAND.
  
 8)ON SHEET A101 THIS SHEET INDICATES A KITHEN BUT NO
 FREEZERS NOR WALK IN COOLERS ARE SHOWN,
 WILL THIS BE UNDER A SEPERATE PERMIT? PLEASE SHOW
 LOCATION. 106.1.2* ADD INFO REQUIRED.
  
 9) SHEET A102 MEZANINE LEVEL IT APPEARS OVER THE 2ND
 FLOOR RESTROOMS IT APPEARSTO BE A VOID SPACE OR ROOM,
 WITH THE EXISTINGWALL HAVING A WALL TYPE MARKER # 3
 AND A NEW WALL WITH NO WALL TYPE DESIGNATION, PLEASE
 EXPLAIN THIS AREA? 106.1.2* ADD INFO REQUIRED.
  
 10) SHEET A201- A205 INDICATE TYPE OF WALL FINISHES,
 THEY INCLUDE WALL COVERINGS, GLASS, METAL LAMINATES,
 PANEL FABRIC, WALL PANEL & WOOD VENEERS, PLEASE PROVIDE
 THE FLAME SPREADINDEX AND SMOKE DEVELOPMENT INDEX FOR
 EACH OF THE MATERIALS TO BE INSTALLED. SEE TABLE 803.5
 PLEASE TAKE NOTE OF FOOTNOTES A, B, AND C.
  
 11) TEXTILES;803.6 TEXTILES. WHERE USED AS INTERIOR
 WALL OR CEILING FINISH MATERIALS, TEXTILES, INCLUDING
 MATERIALS HAVING WOVEN OR NONWOVEN, NAPPED, TUFTED,
 LOOPED OR SIMILAR SURFACE, SHALL COMPLY WITH THE
 REQUIREMENTS OF THIS SECTION.
  
 803.6.1 TEXTILE WALL COVERINGS.
 TEXTILE WALL COVERINGS SHALL HAVE A CLASS A FLAME
 SPREAD INDEX IN ACCORDANCE WITH ASTM E 84 AND BE
 PROTECTED BY AUTOMATIC SPRINKLERS INSTALLED IN
 ACCORDANCE WITH SECTION 903.3.1.1 OR 903.3.1.2 OR THE
 COVERING SHALL MEET THE CRITERIA OF SECTION 803.6.1.1
 OR 803.6.1.2 WHEN TESTED IN THE MANNER INTENDED FOR USE
 IN ACCORDANCE WITH NFPA 265 USING THE PRODUCT MOUNTING
 SYSTEM, INCLUDING ADHESIVE.
  
 803.6.1.1 METHOD A TEST PROTOCOL.
 DURING THE METHOD A PROTOCOL, FLAME SHALL NOT SPREAD TO
 THE CEILING DURING THE 40 KW EXPOSURE. DURING THE 150
 KW EXPOSURE, THE TEXTILE WALL COVERING SHALL COMPLY
 WITH ALL OF THE FOLLOWING:
 1.FLAME SHALL NOT SPREAD TO THE OUTER EXTREMITY OF
 THE SAMPLE ON THE 8-FOOT BY 12-FOOT (203 MM BY 305 MM)
 WALL.
 2.THE SPECIMEN SHALL NOT BURN TO THE OUTER
 EXTREMITY OF THE 2-FOOT-WIDE (610 MM) SAMPLES MOUNTED
 IN THE CORNER OF THE ROOM.
 3.BURNING DROPLETS DEEMED CAPABLE OF IGNITING
 TEXTILE WALL COVERINGS OR THAT BURN FOR 30 SECONDS OR
 MORE SHALL NOT FORM.
 4.FLASHOVER, AS DEFINED IN NFPA 265, SHALL NOT
 OCCUR.
 5.THE MAXIMUM NET INSTANTANEOUS PEAK HEAT RELEASE
 RATE, DETERMINED BY SUBTRACTING THE BURNER OUTPUT FROM
 THE MAXIMUM HEAT RELEASE RATE, DOES NOT EXCEED 300 KW.
  
  
 803.6.1.2 METHOD B TEST PROTOCOL.
 DURING THE METHOD B PROTOCOL, FLAMES SHALL NOT SPREAD
 TO THE CEILING AT ANY TIME DURING THE 40 KW EXPOSURE.
 DURING THE 150 KW EXPOSURE, THE TEXTILE WALL COVERING
 SHALL COMPLY WITH THE FOLLOWING:
 1.FLAME SHALL NOT SPREAD TO THE OUTER EXTREMITIES
 OF THE SAMPLES ON THE 8-FOOT BY 12-FOOT (203 MM BY 305
 MM) WALLS.
 2.FLASHOVER, AS DESCRIBED IN NFPA 265, SHALL NOT
 OCCUR.
  
 803.6.2 TEXTILE CEILING FINISH.
 WHERE USED AS A CEILING FINISH, CARPET AND SIMILAR
 TEXTILE MATERIALS SHALL HAVE A CLASS A FLAME SPREAD
 INDEX IN ACCORDANCE WITH ASTM E 84 AND BE PROTECTED BY
 AUTOMATIC SPRINKLERS.
  
 12) THE MATERIALS LIST ON SHEETS A201-A205 INCLUDE
 GLASS IS THIS TRUELY GLASS OR LIGHT TRANSMITTING
 PLASTICS?IF GLASS PROVIDE HOW IT WILL BE SECURED AND
 THE TYPE OF GLASS? IF PLASTICS
 PLEASE PROVIDE THE SPEC IN ACCORDANCE WITH 2606.4.
  
 13) DECORATIONS AND TRIM:805.1 GENERAL.
 IN OCCUPANCIES OF GROUPS A, E, I, R-1 AND DORMITORIES
 IN GROUP R-2, CURTAINS, DRAPERIES, HANGINGS AND OTHER
 DECORATIVE MATERIALS SUSPENDED FROM WALLS OR CEILINGS
 SHALL BE FLAME RESISTANT IN ACCORDANCE WITH SECTION
 805.2 AND NFPA 701 OR NONCOMBUSTIBLE.
 IN GROUPS I-1 AND I-2, COMBUSTIBLE DECORATIONS SHALL BE
 FLAME RETARDANT UNLESS THE DECORATIONS, SUCH AS
 PHOTOGRAPHS AND PAINTINGS, ARE OF SUCH LIMITED
 QUANTITIES THAT A HAZARD OF FIRE DEVELOPMENT OR SPREAD
 IS NOT PRESENT. IN GROUP I-3, COMBUSTIBLE DECORATIONS
 ARE PROHIBITED.
  
 805.1.1 NONCOMBUSTIBLE MATERIALS.
 THE PERMISSIBLE AMOUNT OF NONCOMBUSTIBLE DECORATIVE
 MATERIAL SHALL NOT BE LIMITED.
  
 805.1.2 FLAME-RESISTANT MATERIALS.
 THE PERMISSIBLE AMOUNT OF FLAME-RESISTANT DECORATIVE
 MATERIALS SHALL NOT EXCEED 10 PERCENT OF THE AGGREGATE
 AREA OF WALLS AND CEILINGS.
 EXCEPTION: IN AUDITORIUMS OF GROUP A, THE PERMISSIBLE
 AMOUNT OF FLAME-RESISTANT DECORATIVE MATERIAL SHALL NOT
 EXCEED 50 PERCENT OF THE AGGREGATE AREA OF WALLS AND
 CEILING WHERE THE BUILDING IS EQUIPPED THROUGHOUT WITH
 AN AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE WITH
 SECTION 903.3.1.1 AND THE MATERIAL IS INSTALLED IN
 ACCORDANCE WITH SECTION 803.3 .
  
 805.2 ACCEPTANCE CRITERIA AND REPORTS.
 WHERE REQUIRED TO BE FLAME RESISTANT, DECORATIVE
 MATERIALS SHALL BE TESTED BY AN APPROVED AGENCY AND
 PASS TEST 1 OR 2, AS APPROPRIATE, DESCRIBED IN NFPA 701
 OR SUCH MATERIALS SHALL BE NONCOMBUSTIBLE. REPORTS OF
 TEST RESULTS SHALL BE PREPARED IN ACCORDANCE WITH NFPA
 701 AND FURNISHED TO THE CODE OFFICIAL UPON REQUEST.
 PLASTIC
 805.3 FOAM PLASTIC .
 FOAM PLASTIC USED AS TRIM IN ANY OCCUPANCY SHALL COMPLY
 WITH SECTION 2604.2 .
 PLASTIC
 805.4 PYROXYLIN PLASTIC .
 IMITATION LEATHER OR OTHER MATERIAL CONSISTING OF OR
 COATED WITH A PYROXYLIN OR SIMILARLY HAZARDOUS BASE
 SHALL NOT BE USED IN GROUP A OCCUPANCIES.
  
 805.5 TRIM.
 MATERIAL USED AS INTERIOR TRIM SHALL HAVE A MINIMUM
 CLASS C FLAME SPREAD INDEX AND SMOKE-DEVELOPED INDEX.
 COMBUSTIBLE TRIM, EXCLUDING HANDRAILS AND GUARDRAILS,
 SHALL NOT EXCEED 10 PERCENT OF THE AGGREGATE WALL OR
 CEILING AREA IN WHICH IT IS LOCATED.
  
 A THOROUGH REVIEW CAN NOT BE MADE AT THIS TIME, AS A
 RESULT OF THE ADDITIONAL
 INFORMATION REQUESTED ADDITIONAL COMMENTS MAY APPEAR
 THAT WERE NOT PART OF THIS REVIEW.
  
 BUILDING PLAN REVIEW
 JIM WITMER C. B. O.
  
 TEL: (561)805-6715
 FAX: (561)659-8026
 E-MAIL: [email protected]
  
  
  
  
 )

Review Stop E ELECTRICAL
Rev No 7 Status P Date 2007-12-10 Cont ID  
Sent By dpalmer Date 2007-12-10 Time 14:06 Rev Time 0.00
Received By dpalmer Date 2007-12-10 Time 14:06 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 6 Status F Date 2007-11-26 Cont ID  
Sent By dpalmer Date 2007-11-26 Time 11:55 Rev Time 0.00
Received By dpalmer Date 2007-11-26 Time 11:26 Sent To  
Notes
2007-11-26 11:55:29** DENIED REVISIONS **
  
 1) NOTE: PLEASE CLARIFY WHERE AND HOW THE EXISTING
 PANEL A/C-1 IS BEING FED?
 PLANS INDICATE THIS PANEL IS TO REMAIN AND REVISED
 RISER MENTIONS PANEL SCHEDULE WAS REMOVED.
 WHAT DOES THIS PANEL NOW FEED AND HOW IS THIS PANEL
 FED?
 PLEASE SEE THE RISER DOES SHOW A 225AMP BREAKER FOR
 SOMETHING HOWEVER THERE IS NO DESIGNATION FOR WHAT THIS
 BREAKER FEEDS.
  
 2) NOTE: PLEASE PROVIDE NOTES ON PLANS PER
 13-413.2.ABC.1.2 AND .2.2.
  
  
 PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR
 COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF
 THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY,
 NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO
 NOT HESITATE IN CONTACTING THIS OFFICE AND THIS
 REVIEWER.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPT.
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 5 Status P Date 2007-08-30 Cont ID  
Sent By dpalmer Date 2007-08-30 Time 16:26 Rev Time 0.00
Received By dpalmer Date 2007-08-30 Time 16:26 Sent To PC
Notes
2007-08-30 16:28:10REVISED ELECTRICLA LIGHTING SHEETS AND PHOTO-METRICS
 STAMPED.
  
 THE LIGHTING AS SHOWN ON FIXTURE TABLE ON PLANS BY
 FIXTURE COUNT IS LESS THAN ALLOWANCES ON THE ENERGY
 CALCULATIONS. THIS IS OK AS THE ENERGY CALCULATIONS ARE
 SHOWN HIGHER YET STILL INDIDCTAE A PASS. THE LPD ON
 TABLES ARE LESS THAN ALLOWANCES.

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2007-08-15 Cont ID  
Sent By dpalmer Date 2007-08-15 Time 11:35 Rev Time 0.00
Received By dpalmer Date 2007-08-15 Time 11:35 Sent To  
Notes
2007-08-15 11:35:55*** PROVISO ***
 **4TH REVIEW**
  
 ***IMPORTANT***
 THE BELOW COMMENTS ARE TO BE REVISED BEFORE ANY ROUGH
 ELECTRICAL INSPECTION IS SCHEDULED OR 30 DAYS WHICH
 EVER COMES FIRST. THIS CONDITION IS PLACED ON THIS
 PROJECT UPON AND 30 DAY TIME BEGINS AT THE DATE OF
 ISSUANCE OF PERMIT FOR REVISED ELECTRICAL PLANS AND
 POSSIBLY ENERGY CALCULATIONS TO BE SUBMITTED FOR
 REVIEW.
 IF PLANS HAVE NOT BEEN SUBMITTED AND CORRECTED IN THIS
 TIME FRAME THE PERMIT MAY BE PLACED ON HOLD OR REVOKED
 AS STATED IN FBC 105.5.2
  
 1) NOTE: PLEASE SEE THE INFORMATION ON LIGHTING
 DENSITIES TABLES ON SHEET E003 HAS NOT BEEN REVISED TO
 COORDINATE WITH LIGHTING PLANS AND THE SUBMITTED ENERGY
 CALCULATIONS.
 PLEASE COORDINATE AND REVISE. PLEASE SEE THE FOLLOWING
 COMMENT ALSO.
 13-415.1.A, 13-415.2
  
 2) NOTE: PLEASE SEE THERE ARE SEVERAL LIGHTING FIXTURES
 ON LIGHTING PLANS WHICH ARE STILL SHOWN BUT IN LT GRAY
 AND DO NOT CONTAIN CIRCUITING OR CONTROLS. PLEASE SEE
 THESE ITEMS ARE REDLINED ON SHEET EL 101 AS IT HAS NOT
 BEEN DETERMINED WHETHER OR NOT THESE ARE A MISPRINT ON
 AN OVERLAY OR IF THESE ARE ACTUAL FIXTURES TO BE
 INSTALLED. PLEASE SEE FOR EXAMPLE *STORAGE 102 WHICH
 SHOWS 3-L-16 FIXTURES, BUT ALSO ONLY SHOWS 1-L27
 FIXTURE? ANOTHER EXAMPLE:*BAR AREA WHICH CONTAIN
 SEVERAL L2,L4 AND L5 FIXTURES WITH NO CONNECTION
 POINTS,* THESE ARE ONLY A COUPLE AS NOTED.
 PLEASE SEE THE PHOTO-METRIC SHEETS WERE NOT REVISED TO
 COORDINATE WITH THE LIGHTING SHEETS. (FIRST FLOOR
 MAINLY).
 PLEASE BE SURE TO CORRELATE AND COORDINATE ALL OF THE
 LIGHTING ON PLANS WITH THE FIXTURES ON PHOTO-METRICS
 SHEETS.
 PLEASE SEE THAT THE ENERGY CALCULATIONS DO SEEM TO
 MATCH WITH PLANS FOR LIGHTING WHICH IS CIRCUITED,
 HOWEVER AS IT IS NOT DETERMINED WHETHER OR NOT SOME OF
 THESE FIXTURES IN LT GRAY ARE TO BE ON PLANS, THE
 ENERGY CALCULATIONS DO CONTAIN MORE FIXTURES/LUMINARIES
 THAN WHAT ARE CIRCUITED ON PLANS.
 PLEASE REVISE ENERGY CALCULATIONS IF ADDITIONAL
 FIXTURES ARE ADDED TO PLANS AND CIRCUITED.
 13-415.1, 13-415.2
 FBC 106.1.2
  
  
 IF THERE ARE ANY QUESTIONS, PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2007-07-13 Cont ID  
Sent By dpalmer Date 2007-07-13 Time 20:29 Rev Time 0.00
Received By dpalmer Date 2007-07-13 Time 19:18 Sent To  
Notes
2007-07-13 20:29:332007-07-13 20:29:33
  
  
 **** UNSAT 3RD REVIEW ****
  
 1) NOTE: PLEASE KNOW WHEN REMOVING SHEETS AND INSERTING
 NEW SHEETS INTO NEW ROLLS PLEASE ATTACH ALL SHEETS
 TOGETHER INTO BOUND ROLLS. PLEASE SEE THE STAPLES USED
 DID NOT MAKE IT THROUGH HALF OF THE SHEETS. PLEASE SEE
 THE ROLLS AND SHEETS ARE FALLING APART WHILE IN
 REVIEW.
 PLEASE ADDRESS THIS WHEN RESUBMITTING PLANS.
 **FBC 106.1.3
  
 2) NOTE: PLEASE SEE THE PACKAGES WERE RESUBMITTED WITH
 OUT THE ORIGINAL PERMIT APPLICATION. THIS WAS NOT IN
 BOXED WITH OTHER DOCUMENTS AS SUBMITTED. PLEASE KNOW
 THE PERMIT APPLICATION MAY BE BROUGHT IN AS SOON AS
 POSSIBLE. PLEASE KNOW THIS HAVE BEEN KEPT BY CITY PLACE
 MANAGEMENT AS THE PLANS WENT BACK WITH THE DESIGNERS OF
 RECORD.
 FBC 106.1
  
 3) NOTE: PLEASE SEE THE REVISED SUBMITTED ENERGY
 CALCULATIONS WERE SUBMITTED. THERE WAS ONLY *ONE* COPY
 SUBMITTED AND THAT COPY WAS JUST THAT. IT WAS A
 *PHOTO-COPY* OF SIGNED AND SEALED CALCULATIONS. PLEASE
 ALSO SEE SIGNATURES WERE MISSING AS REQUIRED PER FBC
 13-103.1.1.1 AND FS 471.025 AND 481.221. PLEASE SEE THE
 OWNER AGENT WAS NOT SIGNED EITHER.
 ** PLEASE SEE PREVIOUS REVIEW COMMENTS WHICH REQUESTED
 COMPLETE COORDINATION OF LIGHTING, FIXTURES, WATTAGE
 AND CONTROLS AS SHOWN ON PLANS TO CORRELATE WITH THE
 ENERGY CALCULATIONS.
 PLEASE SEE THE SHEETS AS SUBMITTED.
 PLEASE SEE *KITCHEN*: PLEASE SEE THE SPACES AND ZONES
 AS PLANS INDICATE CLEAR AUTOMATED CONTROLS FOR THESE
 AREAS YET THE ENERGY CALCULATIONS INDICATE *MANUAL
 ON/OFF*??
 PLEASE SEE SEVERAL OTHER AREAS ON PLANS DO NOT
 COORDINATE WITH PLANS FOR THE SPACES/AREA DESIGNATIONS
 ETC.
 PLEASE SEE TWO FOOD SERVICE AREAS ON PLANS, ONLY ONE ON
 CALCULATIONS.
 PLEASE SEE LIGHTING FOR BATHROOMS: ONLY TWO BATHROOMS
 ON CALCULATIONS, MORE ON PLANS AND THE NUMBER OF
 FIXTURES DO NOT CORRELATE.
 PLEASE SEE OTHER AREAS RM 106, PRIVATE DINING, STORAGE
 AREAS ETC.
 13-415.1.A, 13-415.1.AB.1.1.
 ** AS STATED ON PREVIOUS TWO REVIEWS:
 PLEASE COORIDNATE ALL ROOMS, AREAS, DESIGNATIONS,
 NUMBER OF LUMINARIES, TYPES OF LUMINAIRES, ETC.
  
 4) NOTE: PLEASE SEE COMMENTS FROM OTHER TRADES AS MANY
 OF THE ARCHITECTURAL SHEETS ARE NOT SIGNED, DATED AND
 SEALED AS REQUIRED PER FAC 61G1-16.002, .004, FS
 481.221.
 PLEASE SEE THE FOLLOWING SHEETS FOR EXAMPLE:
 THIS IS BASED ON THE TWO NEWEST DATED SETS:
 SHEETS T101 NOT *ORIGINAL* SIGNATURE IN EITHER SET.
 SHEET LS 101 THE 2ND SET IS NOT SIGNED, DATED OR
 SEALED.
 SHEETS A206 ONE SET IS NOT *ORIGINAL* SIGNATURE, THE
 2ND SET IS ACTUALLY A PHOTO-COPIED SHEET WHICH IS NOT
 SIGNED, DATED OR SEALED.
 SHEETS A207 BOTH SETS DO NOT CONTAIN *ORIGINAL*
 SIGNATURES.
 ** PLEASE BE SURE ALL SHEETS ARE SIGNED, DATED AND
 SEALED AS REQUIRED. SIGNATURES MAY NOT BE STAMPS,
 PHOTO-COPIES OF STAMPS ETC.
  
 *** PLEASE SEE COMMENTS FROM PREVIOUS REVIEWS OF THE
 INTERIOR DEMO PERMIT REVIEW AND THE REVIEWS OF THIS SET
 OF PERMITTED PLANS WHICH CONTAINED NOTES FOR THIS.
 THESE SAME NOTES DATE BACK TO MARCH 07. PLEASE SEE SOME
 OF THE PLANS ORIGINALLY SUBMITTED CONTAIN A
 *RUBBERSTAMP* AND COMMENTS WERE MADE ON THIS AS IT IS
 NOT PERMITTED.
 PLEASE SEE MANY OF THESE SHEETS AS NOTED ABOVE ARE
 COPIES OF THAT SAME *RUBBERSTAMP* AS THOSE PLANS WERE
 RETAINED BY THIS OFFICE.
 PLEASE KNOW PLANS MAY BE RETAINED AND FORWARDED TO THE
 FLORIDA BOARD OF ARCHITECTS AND STATE LEGAL COUNSEL TO
 THE BOARD. THIS COMMENT SHOULD NOT HAVE TO BE REPEATED
 ON THESE REVIEWS.
  
  
 5) NOTE: PLEASE SEE PREVIOUS REVIEW GAVE NOTICE TO FS
 553.80(2)(B) WITH RESPECT TO REPEAT COMMENTS FOR CODE
 COMPLIANCE.
 PLEASE SEE THE PLANS AND SUPPORTING DOCUMENTS (ENERGY
 CALCULATIONS) WILL BE FORWARDED TO THE ASSISTANT
 BUILDING OFFICIAL FOR PIER REVIEW. PLEASE SEE AS THIS
 NOTICE WAS GIVEN PREVIOUSLY AND THE COORDINATION OF THE
 ENERGY CALCULATIONS WITH PLANS HAS NOT BEEN ACHIEVED
 AND FEE MAY BE ASSESSED AS REQUIRED BY THE ABOVE
 FLORIDA STATUTES.
 PLEASE KNOW IF THIS FEE IS ASSESSED AFTER SUCH REVIEWS,
 THIS IS THE RESPONSIBILITY OF THE DESIGNER(S) OF
 RECORD.
 THIS FEE WOULD BE ASSESSED BASED ON THE PLAN REVIEW
 PORTION OF THE BASE PERMIT FEE TIME FOUR AS REQUIRED
 PER THE FLORIDA STATUTES.
 THE AMOUNT OF $18,264.00 WOULD BE DUE BEFORE THE PLANS
 MAY BE RESUBMITTED FOR REVIEW.
  
  
  
 * ** IMPORTANT**
 ONCE ALL REVIEWS ARE DONE AND PLANS ARE
 PICKED UP FOR CORRECTIONS, PLEASE BE
 SURE TO COMPLETELY REMOVE ALL OLD/VOIDED
 SHEETS AND ONLY INSERT NEW REVISED
 SHEETS INTO TWO COMPLETE SETS FOR REVIEW
 AND STAMPING. DO NOT LEAVE ANY
 OLD/VOIDED SHEETS IN SETS.
 PLEASE KNOW ONLY ONE SET OF THE
 OLD/VOIDED SHEETS SHOULD BE SUBMITTED
 FOR REFERENCE.
 THIS WILL HELP IN THE REVIEW PROCESS AND
 AVOID ANY DELAYS.
  
 ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR
 COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF
 THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY,
 NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO
 NOT HESITATE IN CONTACTING THIS OFFICE AND THIS
 REVIEWER.
  
 ** PLEASE BE SURE TO SEE ANY COMMENTS FROM OTHER TRADES
 WHICH MAY AFFECT ELECTRICAL PLANS AND DESIGN CHANGES.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPT.
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2007-06-06 Cont ID  
Sent By dpalmer Date 2007-06-06 Time 19:24 Rev Time 0.00
Received By dpalmer Date 2007-06-06 Time 14:50 Sent To  
Notes
2007-06-06 19:25:52** UNSAT 2ND REVIEW **
  
 *** PLEASE KNOW THAT AS THERE ARE SOME ITEMS WHICH ARE
 FROM PREVIOUS REVIEW AND SOME NEW ITEMS BASED ON
 REVISED PLANS AND NEW COMMENTS.
  
  
 1) NOTE: PLEASE SEE THERE ARE STILL SOME CODE SECTIONS
 ON PLANS WHICH ARE IN NEED O CORRECTING. PLEASE SEE THE
 PREVIOUS NOTES FOR ADA ADOPTED CODE FOR CHAPTER 11 OF
 THE FBC 2004 W/2006 REVISIONS.
 PLEASE SEE SOME ARE NOW INDICATING THE * 1992* CODE?
 PLEASE SEE THE COVER/T-SHEET IS OK, HOWEVER SEE E002.
  
 2) NOTE: PLEASE SEE PREVIOUS NOTE WITH RESPECT TO
 SIGNATURES FOR SOME ARCHITECTURAL AND ENGINEERING
 SHEETS. ONLY ONE LETTER SUBMITTED BY THE ARCHITECT FOR
 SIGNATURE VERIFICATION. THIS WAS NOT SIGNED, DATED AND
 SEALED. THESE LETTER(S) IN PACKAGE WERE PHOTO-COPIES
 AND NOT ORIGINAL. PLEASE ALSO BE SURE THE LETTER IS
 CORRECTLY NOTARIZED PER FLORIDA STATUTES 117.05 AS THE
 NOTARIZATION AS SUBMITTED DOES NOT COMPLY WITH THE
 MINIMUM INFORMATION REQUIRED PER SAID STATUE GIVEN. NO
 LETTER WAS FOUND FOR ENGINEER MR. LIZASOAIN AND THE
 RESPONSE LETTER FROM SGM ENGINEERS DID NOT CONTAIN ANY
 RESPONSE FOR THIS NOTE?
 THESE WILL BE PLACED IN OUR SIGNATURE FILE FOR ANY NEED
 OF FUTURE PROJECTS OR REFERENCE.
 PLEASE BE SURE BOTH LETTERS ARE PROPERLY NOTARIZED PER
 FS 117.05. THIS INFORMATION CAN BE FOUND ON THE STATES
 WEBSITE AT: WWW.LEG.STATE.FL.US/WELCOME/INDEX.CFM **
 THIS COMMENT WAS FOR MR. DOUGLAS AND MR. LIZASOAIN.
  
 3) NOTE: PLEASE SEE COMPLIANCE WITH THE 2004 FBC
 CHAPTER 13 IS STILL IN NEED OF ADDRESSING.
 PLEASE SEE THE SQ FT ON ENERGY CALCULATIONS STILL DOES
 NOT CORRELATE WITH PLANS.
 PLEASE SEE THE NUMBER OF FIXTURES ON ENERGY
 CALCULATIONS DO NOT CORRELATE WITH PLANS.
 PLEASE SEE THE NUMBER OF EACH TYPE OF FIXTURE DOES NOT
 CORRELATE WITH PLANS. (SHOWS ONE FIXTURE FOR EACH TYPE)
 THIS IS NOT POSSIBLE. THE ENERGY CALCULATIONS
 SPECIFICALLY STATE THE NUMBER(S) OF FIXTURE FOR EACH
 TYPE.
 PLEASE SEE THE WATTAGE FOR FIXTURES AND COORDINATION OF
 THE CALCULATIONS TO THE PLANS CAN NOT BE DONE AT THIS
 TIME.
 PLEASE SEE THE VERSION OF THE ENERGY CALCULATIONS IS
 NOT THE CURRENT VERSION FOR THE 2006 REVISIONS TO THE
 2004 FBC. (3.0)
 PLEASE SEE THAT ALL SEPARATE SPACES FOR LIGHTING
 CONTROLS AND/OR OVER RIDES NEED TO MEET
 13-415.1.ABC.1.2. PLEASE SEE ANY TYPE OF OVER RIDE
 DEVICES NEED TO STATE THE MAXIMUM TIME FOR OVER RIDE OF
 SYSTEM OR FOR INDIVIDUAL CONTROL OF A SEPARATE SPACE.
 PLANS INCLUDE NEW TIMER SWITCHES FOR SOME ROOMS HOWEVER
 NO MAXIMUM TIME(S) IS SHOWN ON LEGEND.
 PLEASE SEE 13-415.1.ABC.1.1 (4HRS MAXIMUM FOR TIMER
 TYPE(S) AND 30MINUTES MAXIMUM FOR ANY OS TYPE DEVICES.
 PLEASE INDICATE ALL OVER RIDE DEVICES AND LOCATIONS ON
 PLANS.
 PLEASE STATE ALL MAXIMUM OVER RIDE TIMES.
 PLEASE SEE MISSING EXTERIOR LIGHTING ALLOWANCES ON
 ENERGY CALCULATIONS. PLEASE SEE ENERGY CALCULATIONS
 INDICATE *NONE ENTERED* AND NONE ON THE INPUT DATA
 REPORT.HOW IS THIS POSSIBLE WHEN PLANS CLEARLY
 INDICATE LIGHTING?
 PLEASE CLARIFY WHERE THE ALLOWED WATTS PER SQ FT ON
 TABLE E003 IS COMING FROM? THERE ARE NO NUMBERS IN THE
 TABLES OF THE FBC CHAPTER 13-415.2.B, 13-415.2.C.1
 WHICH CONTAIN THESE SAME HIGH NUMBERS. PLEASE SEE THE
 ENERGY CALCULATIONS AS BEING SUBMITTED IS METHOD A.
 PLEASE CALL TO GO OVER THIS.
 PLEASE SEE THE METHOD OF CONTROL FOR LIGHTING ON ENERGY
 CALCULATIONS IS NOT ENTIRELY ACCURATE AS SOME OF THE
 LIGHTING IS NOT ON A PROGRAMMABLE TIMER.
 PLEASE BE SURE THE *OWNER AGENT* SPACE ON THE SHEET #2
 FOR CERTIFICATIONS IS SIGNED. THIS IS BLANK AT THIS
 TIME.13-103.1.1.1
 ** PLEASE KNOW THAT AS MUCH OF THIS INFORMATION HAS NOT
 YET BEEN COORDINATED REVIEW OF THESE ITEMS WILL STILL
 NEED TO TAKE PLACE FOR CODE COMPLIANCE REVIEW.
  
 4) NOTE: THE RESPONSE LETTER MENTIONS THE EXISTING
 SERVICE FOR PREVIOUS RESTAURANT IS OF SUFFICIENT SIZE
 AND THE PREVIOUS SERVICE FOR THE BUSINESS OCCUPANCY
 WILL NOT BE NEEDED. PLEASE PROVIDE DETAIL AND NOTES ON
 THIS PREVIOUS SERVICE EQUIPMENT INCLUDING, METER, MAINS
 AND PANELS BEING DELETED AND REMOVED.
 FBC 106.1.3.5.1.2
 NEC 230.
  
 5) NOTE: PLEASE SEE PREVIOUS NOTE WHICH REQUESTED
 (ALL) SERVICE EQUIPMENTTO BE SHOWN ON PLANS. MOST
 WERE LOCATED ON PREVIOUS PLANS HOWEVER HDP COULD NOT BE
 LOCATED.
 PLEASE SPECIFY THE SERVICE EQUIPMENT, ELECTRICAL
 PANELS, AND TRANSFORMER LOCATIONS. ARE THESE LOCATED IN
 AN ELECTRICAL ROOM?
 PLEASE PROVIDE ROOM AND AREA DESIGNATIONS FOR ALL AREAS
 AND ROOMS.
 AS REQUESTED PLEASE INDICATE ROOMS AND USE AS SECOND
 FLOOR ROOM FOR SOME OF THE ELECTRICAL EQUIPMENT IS NOT
 IDENTIFIED.
 110.26, 240.24, 450.11, 450.13, 408.7 ETC
  
 6) NOTE: PLEASE SEE THE LOAD CALCULATIONS SUBMITTED ARE
 NOT COMPLETED AT THIS TIME. PLEASE SUBMIT A COMPLETE
 LOAD SUMMARY ON HOW LOADS WERE DERIVED FOR SERVICE.
 PLEASE SEE PREVIOUS NOTES WITH RESPECT TO SHOW WINDOWS,
 SIGN CIRCUIT. PLEASE CLARIFY HOW AND WHERE CU 1,2,3,4
 AND 5 ARE FED? LOADS ON A/C HEAT ETC.
 PLEASE SEE LOADS ON EACH PANEL ARE NOT CLEAR WHERE AND
 WHAT TYPE OF DE-RATING IS BEING DONE. (EXAMPLE, PLEASE
 SEE RECEPTACLES WHICH INDICATES FOR DEMANDON EACH
 PANEL COLUMN * NEC *. THIS IS OK FOR LOADS ON PANELS
 HOWEVER HOW ARE NO RECEPTACLE LOADS SHOWN ON LDP? IT IS
 BEING ASSUMED HOW LOADS ARE BEING FIGURED, HOWEVER AS
 THESE ARE RECORD SETS OF PLANS, THESE SHOULD COORDINATE
 WITH THAT OF THE NEC.
 PLEASE SHOW DETAILED LOAD CALCULATIONS. 215.3, 230.42,
 220.12, 220.14, 220.42, 220.43, 220.44, ETC.
  
 7) NOTE: PLEASE SEE THE MISSING SIGN CIRCUIT IS NOW
 SHOWN HOWEVER THE LOAD AS INDICATED DOES NOT MEET THE
 MINIM PER 600.5 (1200VA MIN)
 PLEASE SEE 220.43A FOR LOADS FOR SHOW WINDOW
 RECEPTACLES.
  
 8) NOTE: PLEASE SUBMIT MANUFACTURES SPECS/CUT SHEETS ON
 THE LIGHTING CONTROL PANELS. THIS WAS REQUESTED ON THE
 PREVIOUS REVIEW. THE RESPONSE MENTIONS SHEETS ADDED TO
 PLANS, HOWEVER NO LISTINGS COULD BE LOCATED AND
 SPECS/CUT SHEETS ON ACTUAL LIGHTING CONTROL/DIMMING
 PANELS ARE BEING REQUESTED FOR REVIEW. 110.3, 90.7.
 FBC 106.1.2
  
 9) NOTE: PLEASE SEE THE PHOTO-METRICS WERE SUBMITTED AS
 PREVIOUSLY REQUESTED FOR REVIEW OF LIGHTING LEVELS OF
 EGRESS PATHS UNDER NORMAL AND EMERGENCY CONDITIONS
 HOWEVER PLANS MENTIONS AND SHOWS NUMEROUS
 *EMERGENCY/NIGHT LIGHT* BATTERY BACK UP TYPE OF
 FIXTURES SHOWN AS BEING DIMMED TO AS MUCH AS 30%. HOW
 IS THE MINIMUM NORMAL AND EMERGENCY LIGHTING LEVELS
 STILL OBTAINED AS REQUIRED UNDER THE LIFE SAFETY CODE
 WHEN THE DIMMED LEVELS FALL BELOW THE 10FT CANDLES FOR
 STAIRS UNDER NORMAL AND UNDER 1FT CANDLE FOR STAIRS
 UNDER EMERGENCY. HOW ARE THE MINIMUM LIGHTING LEVELS
 MET FOR ALL OTHER EGRESS PATHS UNDER EMERGENCY WHEN
 LIGHTS ARE DIMMED AT 30%? ONE STAIR DOES INDICATE A
 NOTE WHICH STATES THE LIGHTING FIXTURES WILL BE WIRED
 AHEAD OF LIGHTING CONTROL AND DIMMING PANELS. PLEASE
 KNOW AT THIS TIME THIS INFORMATION IS BEING FORWARDED
 TO THE FIRE MARSHAL FOR REVIEW.
 THIS IS REQUIRED FOR LIFE SAFETY AND TRIPPING HAZARDS.
  
 10) NOTE: PLEASE BE SURE WHEN OLD/VOIDED ARE REMOVED
 THAT WHEN NEW SHEETS ARE INSERTED OR WHEN NEW SETS ARE
 SUBMITTED THAT ALL SHEETS ARE BOUND INTO SETS. PLEASE
 SEE THAT ALL THE MEP SHEETS WERE SUBMITTED LOOSE IN
 SETS.
  
 11) NOTE: PLEASE LABEL LIGHTING/DIMMING PANELS. (D-1,
 D-2)
 FBC 106.1.2, 106.3.5.1.2
  
 12) NOTE: PLEASE SEE FS 553.80(2)(B) WITH RESPECT TO
 REPEAT CODE COMPLIANT COMMENTS. THIS IS ONLY A NOTICE
 GIVEN AT THIS TIME.
  
 ** PLEASE KNOW AS THERE IS INFORMATION NOT YET
 SUBMITTED, THERE MAY NEW COMMENTS ON THE FOLLOWING
 REVIEW ONCE PLANS ARE COMPLETED FOR REVIEW.
  
 ** PLEASE SEE SOME ITEMS ARE REDLINED ON ONE OF THE
 SETS FO PLANS FOR SOME ITEMS WHICH MAY HELP LOCATE
 NOTES AS TYPES.
  
 ** PLEASE KNOW AS STATED ON PREVIOUS REVIEW: PLEASE BE
 SURE TO CALL IF THERE ARE ANY QUESTIONS OR COMMENTS
 WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF THERE ARE
 ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, NOT
 UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO NOT
 HESITATE IN CONTACTING THIS OFFICE AND THIS REVIEWER.
  
 * ** IMPORTANT**
 ONCE ALL REVIEWS ARE DONE AND PLANS ARE
 PICKED UP FOR CORRECTIONS, PLEASE BE
 SURE TO COMPLETELY REMOVE ALL OLD/VOIDED
 SHEETS AND ONLY INSERT NEW REVISED
 SHEETS INTO TWO COMPLETE SETS FOR REVIEW
 AND STAMPING. DO NOT LEAVE ANY
 OLD/VOIDED SHEETS IN SETS.
 PLEASE KNOW ONLY ONE SET OF THE
 OLD/VOIDED SHEETS SHOULD BE SUBMITTED
 FOR REFERENCE.
 THIS WILL HELP IN THE REVIEW PROCESS AND
 AVOID ANY DELAYS.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPT.
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2007-03-31 Cont ID  
Sent By dpalmer Date 2007-03-31 Time 17:00 Rev Time 0.00
Received By dpalmer Date 2007-03-31 Time 14:21 Sent To  
Notes
2007-03-31 17:00:41** UNSAT **
  
 *RUTH CHRIS*
 INTERIOR BUILD-OUT W/ SOME EXTERIOR WORK.
 PREVIOUS OCCUPANCY: BUSINESS.
  
 1) NOTE: PLEASE KNOW THAT ANY PERMIT APPLICATIONS WHICH
 ARE SUBMITTED AFTER DECEMBER 8TH, 2006 PLACES PROJECTS
 UNDER THE NEW CODES ADOPTED BY THE STATE.
 PLEASE SEE THAT THIS SHALL INCLUDE 2006 REVISIONS TO
 THE 2004 FBC FOR ALL TRADES AND THE 2005 NFPA-70.
 PLEASE KNOW THERE ARE CHANGES IN THE FBC WHICH MAY
 AFFECT DESIGNS FOR ALL TRADES.
 PLEASE LIST THE FOLLOWING ON ELECTRICAL SHEETS FOR THIS
 REVIEWER AT A MINIMUM.
 2004 FBC W/ 2006 REVISIONS
 2005 NFPA-70
 2002 NFPA-72
 2003 NFPA-101
  
 ** PLEASE SEE SOME AREAS WHICH STATE CODES WHICH ARE
 NOT YET ADOPTED BY THE STATE OR CODES WHICH ARE NO
 LONGER IN EFFECT. PLEASE GO OVER PLANS AS CODES AND
 SECTIONS ARE STATED FROM SEVERAL CODES.
 PLEASE SEE THE PLANS STATES THE 2001 FBC FOR ADA
 COMPLIANCE; HOWEVER THIS SHOULD BE THE 2004 W/ 2006
 REVISIONS. THE 2004 FBC WENT INTO EFFECT ON OCT. 1ST,
 2005.
 PLEASE SEE AREAS WHERE THE PLANS INDICATE THE 2007
 NFPA-72 AND 2006 NFPA-101. SEE CODES ABOVE FOR RELEVANT
 ADOPTED CODES.
 PLEASE SEE OTHER REFERENCES TO ADA WHICH SHOULD BE
 NOTED TO THE 2004 FBC.
  
 2) NOTE: PLEASE SEE MISSING FIRM LICENSE NUMBER FOR THE
 ARCHITECTURAL FIRM AS REQUIRED ON TITLE BLOCKS PER FAC
 61G1-16.004 AND FS 481.219.
 PLEASE SEE THIS INFORMATION IS REQUIRED FOR ALL TRADES
 AND FOR ALL SHEETS WHICH CONTAIN THIS TITLE BLOCK
 WHETHER OR NOT COMMENT IS MADE BY ANY OTHER TRADE
 REVIEWER(S).
  
 3) NOTE: PLEASE SEE SEVERAL ARCHITECTURAL SHEETS IN THE
 PLANS ARE NOT SIGNED OR SEALED. PLEASE SEE SHEETS
 T-101, LS (BOTH) AND SHEET A-100 THRU A-205. PLEASE SEE
 FS 481.221.
  
 4) NOTE: PLEASE SEE SHEETS FOR ARCHITECTURAL AND SOME
 ENGINEERING SHEETS APPEAR TO BE SIGNED WITH *INITIALS*,
 IF THESE ARE INDEED THE LEGAL SIGNATURES OF THESE
 DESIGNERS, PLEASE PROVIDE SIGNED, DATED AND SEALED
 LETTERS FOR SIGNATURE VERIFICATION. THESE WILL BE
 PLACED IN OUR SIGNATURE FILE FOR ANY NEED OF FUTURE
 PROJECTS OR REFERENCE.
 PLEASE BE SURE LETTERS ARE ALSO PROPERLY NOTARIZED PER
 FS 117.05.
 ** THIS COMMENT IS FOR MR. DOUGLAS AND MR. LIZASOAIN.
  
 5) NOTE: PLEASE SEE FBC 2004 11-4.28.1, .2 AND .3(4)
 AND STATE THE MINIMUM HORN, STROBE LEVELS ON PLANS FOR
 ADA REQUIRED AREAS. DEVICES ARE BEING SHOWN ON
 PLANS/LEGEND. PLEASE CORRELATE WITH PLANS, AND FA
 SHEETS SUBMITTED.
 ** PLEASE KNOW THAT THE FIRE ALARM WILL BE UNDER A
 SEPARATE PERMIT HOWEVER THE BASE LIFE SAFETY SYSTEM IS
 REQUIRED ON BASE PLANS AS SHOWN. DO NOT REMOVE FROM
 SETS.
 FBC 106.3.5.1.2
  
 6) NOTE: PLEASE SEE COMPLIANCE WITH THE 2004 FBC
 CHAPTER 13 FOR CONTROL OF LIGHTING PER 13-415.1ABC.1.1,
 .1.2 AND .1.3. PLEASE SEE LIGHTING DIMMING PANELS ARE
 SHOWN HOWEVER COMPLIANCE WITH THE 2004 FBC W/2006
 REVISIONS IS NOT SHOWN AT THIS TIME.
 PLEASE SUBMIT LIGHTING POWER DENSITIES PER THE 2004 FBC
 W/ 2006 REVISION. PLEASE SEE 13-415.1.AB.1.1, 13-415.2
 FOR LIGHTING PERFORMANCE CALCULATIONS WHICH ARE TO
 CORRELATE WITH THE ENERGY CALCULATIONS SUBMITTED.
 PLEASE SEE THE ENERGY CALCULATIONS DO NOT INDICATE ALL
 THE FIXTURES, TYPES AND WATTAGE PER FIXTURE AS
 REQUIRED.
 PLEASE SEE THAT THE FIXTURE SCHEDULE SHALL BE SPECIFIC
 FOR FIXTURES TO BE INSTALLED AND COORDINATION WITH THE
 LPD/CALCULATIONS TO BE REVIEWED FOR COMPLIANCE. PLEASE
 SUBMIT SCHEDULING IF A LIGHTING CONTROL SYSTEM IS
 INSTALLED.
 PLEASE INDICATE ALL OVER RIDE DEVICES AND LOCATIONS ON
 PLANS.
 PLEASE STATE ALL MAXIMUM OVER RIDE TIMES.
 PLEASE SEE MISSING EXTERIOR LIGHTING ALLOWANCES ON
 PLANS/ENERGY CALCULATIONS.
 PLEASE SEE THE ENERGY CALCULATIONS INDICATE *MANUAL
 ON/OFF* FOR METHOD OF LIGHTING CONTROL, HOW IS THIS
 POSSIBLE WHEN LIGHTING IS REQUIRED TO BE AUTOMATED.
 PLEASE BE SURE TO HAVE THE DESIGNER OF RECORD FOR THE
 ENERGY CALCULATIONS SIGN, DATE AND SEAL THESE AS
 REQUIRED PER 13-103.1.1.1
 ** PLEASE KNOW THAT AS MUCH OF THIS INFORMATION HAS NOT
 YET BEEN SUBMITTED, MANY OF THESE THINGS CAN NOT YET BE
 REVIEWED FOR CODE COMPLIANCE.
  
 7) NOTE: PLEASE SEE THE SQUARE FOOTAGE ON T-101 SHEET
 DOES NOT CORRELATE WITH THE SQ FT ON THE ENERGY
 CALCULATIONS.
 PLEASE CORRELATE. FBC 106.1.2
  
 8) NOTE: PLEASE KNOW THAT THE SIGNS AS SHOWN ON THE
 ELEVATIONS ON PLANS WILL BE UNDER SEPARATE PERMITS.
 THIS IS ONLY NOTED AND NO CHANGES NEED TO BE MADE.
  
 9) NOTE: PLEASE INDICATE THE EXISTING OR NEW
 TRANSFORMER GROUND PER 250.20,250.30, 250.66. PLEASE
 INDICATE THE ATTACHMENT POINT.
  
 10) NOTE: PLEASE CLARIFY RISER AS THE SERVICE IS BEING
 SHOWN AS ONE EXISTING SERVICE YET THIS BUILD OUT IS
 BEING DONE FROM WHAT USED TO BE TWO SEPARATE TENANTS.
 WHAT IS BEING DONE WITH THE SERVICE WHICH USED TO FEED
 THE PREVIOUS TENANT WHO IS BEING TAKEN OVER/EXPANDED?
 FBC 106.1.2
  
 11) NOTE: PLEASE SPECIFY THE SERVICE EQUIPMENT,
 ELECTRICAL PANELS, AND TRANSFORMER LOCATIONS. ARE THESE
 LOCATED IN AN ELECTRICAL ROOM?
 PLEASE PROVIDE ROOM AND AREA DESIGNATIONS FOR ALL AREAS
 AND ROOMS.
 110.26, 240.24, 450.11, 450.13 ETC
 PLEASE INDICATE HOW THE TRANSFORMER IS MOUNTED.
 EXISTING FLOOR?
  
 12) NOTE: PLEASE SEE THE LOAD CALCULATIONS SUBMITTED
 ARE NOT COMPLETED AT THIS TIME. PLEASE SEE THE LOAD
 SUMMARY WHICH DOES NOT SHOW ANY LIGHTING LOADS? PLEASE
 SHOW. 215.3, 230.42, 220.12, 220.14, 220.42, 220.43,
 220.44, ETC.
  
 13) NOTE: PLEASE SEE MISSING SIGN CIRCUIT PER 600.5,
 PLEASE INDICATE MINIMUM LOADS REQUIRED.
 PLEASE ALSO SEE 210.62 FOR MISSING WINDOW RECEPTACLES
 AND LOADS PER 220.43.
  
 14) NOTE: PLEASE SUBMIT MANUFACTURES SPECS/CUT SHEETS
 ON THE LIGHTING CONTROL PANELS.
 PLEASE SEE NOTE #6 AS ONLY DIMMING PANELS ARE BEING
 SHOWN.
 110.3, 90.7.
 FBC 106.1.2
  
 15) NOTE: PLEASE SEE 2005 NEC 210.8B3 AS ALL 15/20AMP
 120V RECEPTACLES IN KITCHEN AREAS AND THE LIKE SHALL BE
 GFI/GFI PROTECTED. PLEASE SEE PANEL SCHEDULE NOTES SOME
 OF THESE BUT NOT ALL.
  
 16) NOTE: PLEASE PROVIDE SHUNT DETAIL FOR CONNECTION
 AND SHUT OFF OF ALL ELECTRICAL TO HOOD. NFPA-96. FBC
 106.1.2
  
 17) NOTE: PLEASE CONFIRM TIMES ON EMERGENCY LIGHTING
 FIXTURES AS NOTED ON LEGEND.
 PLEASE SEE NFPA-101 7.8, 7.9
 PLEASE ALSO SUBMIT PHOTO-METRICS FOR MINIMUM LEVELS OF
 LIGHTING FOR STAIRS AND EGRESS PATHS PER NFPA-101
 7.8.1.3, 7.9.2.2.
 THIS REQUIRES A MINIMUM OF 10FT CANDLES UNDER NORMAL
 FOR STAIRS AND IS PERMITTED TO DOWN TO 1FC UNDER
 EMERGENCY CONDITIONS.
 THIS IS REQUIRED FOR LIFE SAFETY AND TRIPPING HAZARDS.
  
 ** PLEASE KNOW AS THERE IS INFORMATION NOT YET
 SUBMITTED, THERE MAY NEW COMMENTS ON THE FOLLOWING
 REVIEW ONCE PLANS ARE COMPLETED FOR REVIEW.
  
 * ** IMPORTANT**
 ONCE ALL REVIEWS ARE DONE AND PLANS ARE
 PICKED UP FOR CORRECTIONS, PLEASE BE
 SURE TO COMPLETELY REMOVE ALL OLD/VOIDED
 SHEETS AND ONLY INSERT NEW REVISED
 SHEETS INTO TWO COMPLETE SETS FOR REVIEW
 AND STAMPING. DO NOT LEAVE ANY
 OLD/VOIDED SHEETS IN SETS.
 PLEASE KNOW ONLY ONE SET OF THE
 OLD/VOIDED SHEETS SHOULD BE SUBMITTED
 FOR REFERENCE.
 THIS WILL HELP IN THE REVIEW PROCESS AND
 AVOID ANY DELAYS.
  
 ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR
 COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF
 THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY,
 NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO
 NOT HESITATE IN CONTACTING THIS OFFICE AND THIS
 REVIEWER.
  
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPT.
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 5 Status P Date 2007-11-26 Cont ID  
Sent By mawillia Date 2007-11-26 Time 16:20 Rev Time 0.00
Received By mawillia Date 2007-11-26 Time 15:41 Sent To  
Notes
2007-11-26 16:20:38*****APPROVED, REVISION # 9, DATED 11/07/2007*****
  
 REVISED PLAN SHEETS LS 101-102 AND F101-102 WERE
 STAMPED, INITIALED, AND DATED.

Review Stop FIRE FIRE DEPARTMENT
Rev No 4 Status P Date 2007-08-16 Cont ID  
Sent By mawillia Date 2007-08-16 Time 19:18 Rev Time 0.00
Received By mawillia Date 2007-08-16 Time 18:13 Sent To  
Notes
2007-08-16 19:18:24*****APPROVED*****
  
  
 ALL COMMENTS FROM THE PREVIOUS FIRE PLAN REVIEWS HAVE
 BEEN ADDRESSED;PLAN SHEETS LS 101-102, A200,
 F101-102, F101-102, AND ES101-102 WERE STAMPED,
 INITIALED, AND DATED

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status F Date 2007-08-06 Cont ID  
Sent By mwennerg Date 2007-08-06 Time 12:45 Rev Time 0.00
Received By mwennerg Date 2007-08-06 Time 12:45 Sent To  
Notes
2007-08-06 12:48:31***DENIED***
  
 1) IT IS STILL UNCLEAR AS TO THE EMERGENCY LIGHTING LAY
 OUT ON THE SECOND FLOOR. PLEASE CLEARLY ILLUSTRATE
 LOCATIONS AS INDICATED IN THE ELECTRICAL SYMBOL LEGEND.
 PLANS OTHERWISE APPEAR CODE COMPLIANT AND SHOULD BE OK
 UPON CORRECTION.
  
  
 MIKE WENNERGREN, ASSISTANT FIRE MARSHAL
 FIRE PLAN REVIEW
 FIRE PREVENTION (561) 804-4756

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status F Date 2007-06-08 Cont ID  
Sent By mawillia Date 2007-06-08 Time 15:48 Rev Time 0.00
Received By mawillia Date 2007-06-08 Time 15:14 Sent To  
Notes
2007-06-08 15:48:13****UNSAT*****
  
 THE FOLLOWING COMMENTS FROM THE PREVIOUS FIRE PLAN
 REVIEW STILL NEED TO BE ADDRESSED:
  
  
 09.IT APPEARS THAT THE EXIT LIGHTS ARRANGEMENT ON
 SHEETSEL102 DO NOT CORRELATE TO LS102.
  
 10.NO EMERGENCY LIGHTING NOTED.
  
  
  
  
  
 TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE
 LETTER INDICATING HOW/WHERE EACH ITEM WAS ADRESSED
  
  
 CAPT. MICHAEL A. WILLIAMS
 FIRE PLAN REVIEW
 561-805-6722
  
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2007-05-17 Cont ID  
Sent By mawillia Date 2007-05-17 Time 12:22 Rev Time 0.00
Received By mawillia Date 2007-05-17 Time 10:32 Sent To  
Notes
2007-05-17 12:22:08*****DENIED*****
  
  
 01.THE COMPLETE ADDRESS, INCLUDING THE SUITE NUMBER,
 SHALL BE IN THE TITLE BLOCK OF EACH SUBMITTED PLAN
 SHEET.
  
 02.NFPA 101, LIFE SAFETY CODE, 2003 EDITION AND THE
 FLORIDA FIRE PREVENTION CODE - 2004 EDITION SHALL BE
 REFERENCED.AMEND SHEET T101, UNDER APPLICABLE CODES.
  
 03.STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR
 DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241.
  
 04.THE DEMOLITION OF EXISTING AND/OR THE STOCKING OF
 NEW BUILDING MATERIALS SHALL NOT HINDER OR INTERFERE
 WITH EMERGENCY ACCESS TO THE PROPERTY OR VICINITY
 THEREOF (INCLUDING FIRE LANES).
  
 05.COMBUSTIBLE WASTE MATERIALS, DUST, AND DEBRIS
 SHALL BE REMOVED FROM THE SITE DAILY OR MORE FREQUENTLY
 AS NECESSARY FOR SAFE OPERATRIONS.
  
 06.ON THE APPROPIATE EXTERIOR ELEVATION (SHEET A200),
 DISPLAY THE SUITE NUMBER FOR THIS PROJECT.AS PER WEST
 PALM BEACH CODE,SUITE NUMBERS SHALL BE NO LESS THAN
 3" IN HEIGHT AND NO LESS THAN 1" IN WIDTH.
  
 07.ON SHEET F001, FIRE PROTECTION NOTE #1, REFERENCE
 NFPA 13 - 2002 EDITION.
  
 08.ON SHEET ED101 & ED102, GENERAL NOTE (D.), MIKE
 CARSILLO, NOT CARSICCO, SHOULD BE LISTED AS THE FIRE
 MARSHAL.
  
 09.IT APPEARS THAT THE EXIT LIGHTS ARRANGEMENT ON
 SHEETS EL101- EL102 DO NOT CORRELATE TO LS101- LS102.
  
 10.NO EMERGENCY LIGHTING NOTED.
  
 11.COMMERCIAL COOKING EQUIPMENT SHALL BE IN ACCORDANCE
 WITH NFPA 96 - 2001 EDITION.
  
  
  
 TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE
 LETTER INDICATING HOW/WHERE EACH ITEM WAS ADRESSED
  
  
 CAPT. MICHAEL A. WILLIAMS
 FIRE PLAN REVIEW
 561-805-6722
  
  
  

Review Stop G GAS REVIEW
Rev No 5 Status P Date 2007-09-05 Cont ID  
Sent By kstevens Date 2007-09-05 Time 18:35 Rev Time 0.00
Received By kstevens Date 2007-09-05 Time 18:35 Sent To  
Notes
2007-09-05 18:35:46REVISION OK --SHTS P303 & P401

Review Stop G GAS REVIEW
Rev No 4 Status P Date 2007-08-21 Cont ID  
Sent By kstevens Date 2007-08-21 Time 10:14 Rev Time 0.00
Received By kstevens Date 2007-08-20 Time 19:00 Sent To  
Notes
2007-08-21 10:20:08 
  
  
  
  
 PASSED/PROVISO
  
  
 PER SECTION 409.5 EACH APPLIANCE SHALL BE PROVIDED WITH
 A SHUT OFF VALVE. THERE ARE TWO FRYERS INDICATED BUT
 ONLY ONE SHUT OFF VALVE. THERE ARE TWO CONVECTION OVENS
 INDICATED BUT ONLY ONE SHUT OFF VALVE. ALSO 1" IS
 REQUIRED FOR EACH TANKLESS WATER HEATER PER TABLE
 402.4(2). 3/4" IS SHOWN FOR EACH. A REVISION IS
 REQUIRED PRIOR TO FIRST GAS INSPECTION TO CORRECT THESE
 ITEMS LISTED ON THE PROVISO.--GAS VALVES SHALL BE
 ACCESSIBLE PER SECTION 409.1.3.
  
  
  
  
  
  
 .

Review Stop G GAS REVIEW
Rev No 3 Status F Date 2007-08-10 Cont ID  
Sent By kstevens Date 2007-08-10 Time 08:14 Rev Time 0.00
Received By kstevens Date 2007-08-08 Time 18:58 Sent To  
Notes
2007-08-10 08:16:52DENIED
 REFERENCE: FBC-2004 FUEL GAS
  
  
 ******FROM PREVIOUS REVIEW:
 ****FROM PREVIOUS REVIEWS:
  
  
 1. SHT P402 THE FOLLOWING IS REQUIRED FOR THE GAS
 PERMIT APPROVAL:
  
 A. SUBMIT AN ISOMETRIC DRAWING THAT
 CLEARLY SHOWS ALL CUT SECTIONS OF PIPE
 AND CORRESPONDING LENGTHS PER FBC-2004
 FUEL GAS CODE.
 ******RESPONSE NOTED, BUT A CLARIFICATION IS REQUIRED
 ON THE DROP WITH THE SOLENOID VALVE. THE TOTAL LENGTH
 IS INDICATED AS 3'0", (1'0" +2'0").
 ****RESPONSE NOTED, BUT THE PIPE SIZING THRU THE SHUT
 OFF VALVE FOR EACH GAS APPLIANCE SHALL BE FULL SIZE PER
 TABLE 402.4(2) AND INDICATED ON THE ISOMETRIC. ALSO
 EACH APPLIANCE SHALL PROVIDED WITH A SHUT OFF VALVE PER
 SECTION 409.5. ONLY ONE SUPPLY LINE WITH ONE SHUT OFF
 VALVE IS INDICATED FOR TWO FRYERS. PLEASE CORRECT THE
 GAS RISER DIAGRAM.
  
 B. OK
 C. OK
 D. OK
 E. OK
  
 2. OK
  
 36. TO HELP EXPEDITE PLAN REVIEW, PLEASE RESUBMIT THE
 MARKED UP PLUMBING PLANS ALONG WITH THE NEW PLANS.
 *******NO RESPONSE, NOT ADDRESSED.
 ****RESPONSE NOTED, BUT NO MARKED UP PLUMBING PLANS
 FOUND.
  
 **********NEW COMMENTS**********
  
 1B. IT APPEARS THAT NEW SHEETS WERE INSERTED INTO THE
 OLD PLANS. PLEASE MAKE SURE THE NEWEST REVISED SHEETS
 ARE SUBMITTED IN THE NEW SETS OF PLANS FOR REVIEW.
 SECTION 106.1.1.
  
 2B. SHT FS-5 PLUMBING/GAS SCHEDULE GK113 INDICATES QTY
 AS "LOT" BUT MANUF SPECIFICATION SHEET COVER SHEET
 INDICATES QUANTITY AS TWO FRYERS. PLEASE CLARIFY.
 SECTION 106.1.1.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUM-
 BER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICA
 TION PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK
 YOU FOR YOUR ANTICIPATED COOPERATION.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 805-6731
 E-MAIL [email protected]

Review Stop G GAS REVIEW
Rev No 2 Status F Date 2007-06-08 Cont ID  
Sent By kstevens Date 2007-06-08 Time 14:11 Rev Time 0.00
Received By kstevens Date 2007-06-08 Time 14:11 Sent To  
Notes
2007-06-08 14:12:40DENIED
 REFERENCE: FBC-2004 FUEL GAS
  
 1. SHT P402 THE FOLLOWING IS REQUIRED FOR THE GAS
 PERMIT APPROVAL:
  
 A. SUBMIT AN ISOMETRIC DRAWING THAT
 CLEARLY SHOWS ALL CUT SECTIONS OF PIPE
 AND CORRESPONDING LENGTHS PER FBC-2004
 FUEL GAS CODE.
 ******RESPONSE NOTED, BUT A CLARIFICATION IS REQUIRED
 ON THE DROP WITH THE SOLENOID VALVE. THE TOTAL LENGHT
 IS INDICATED AS 3'0", (1'0" +2'0").
  
 B. SHOW THE DISTANCE FROM THE POINT OF
 DELIVERY, (METER), TO THE MOST REMOTE
 OUTLET IN THE BUILDING AND/OR SYSTEM PER
 FBC-2004 FUEL GAS CODE APPENDIX A - USE
 OF CAPACITY TABLES A.3.1(4).
 ******RESPONSE NOTED, BUT DISTANCE SHALL BE VERIFIED
 WHEN COMMENT "A" CLARIFIED.
  
 C. OK
  
 D. SUBMIT MANUFACTURE SHEETS FOR ALL GAS
 EQUIPMENT TO VERIFY COMPLIANCE WITH
 STANDARDS NFPA 54, NFPA 58, AND THE
 FBC-2004 FUEL GAS CODE SEC 402.2.
 ******RESPONSE NOTED, NOT ADDRESSED.
  
 E. EMERGENCY HOOD SHUT DOWN SHUT OFF
 VALVE TO BE BELOW CEILING. MANUAL SHUT
 OFF VALVE TO BE UPSTREAM. UNION TO BE
 DOWN STREAM OF MANUAL VALVE.
 ******RESPONSE NOTED, BUT NOT COMPLETLY ADDRESSED. NO
 MANUAL SHUT OFF VALVE UPSTREAM OF THE SOLENOID VALVE
 AND NO UNION INDICATED.
  
 2. OK
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUM-
 BER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICA
 TION PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK
 YOU FOR YOUR ANTICIPATED COOPERATION.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 805-6731
 E-MAIL [email protected]

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2007-06-07 Cont ID  
Sent By kstevens Date 2007-05-09 Time 15:43 Rev Time 0.00
Received By kstevens Date 2007-05-09 Time 15:43 Sent To  
Notes
2007-06-07 15:49:42DENIED
 REFERENCE: FBC-2004 FUEL GAS
  
 1. SHT P402 THE FOLLOWING IS REQUIRED FOR THE GAS
 PERMIT APPROVAL:
  
 A. SUBMIT AN ISOMETRIC DRAWING THAT
 CLEARLY SHOWS ALL CUT SECTIONS OF PIPE
 AND CORRESPONDING LENGTHS PER FBC-2004
 FUEL GAS CODE.
  
 B. SHOW THE DISTANCE FROM THE POINT OF
 DELIVERY, (METER), TO THE MOST REMOTE
 OUTLET IN THE BUILDING AND/OR SYSTEM PER
 FBC-2004 FUEL GAS CODE APPENDIX A - USE
 OF CAPACITY TABLES A.3.1(4).
  
 C. SUBMIT A DETAIL SHOWING THE TYPE,
 LOCATION, SIZE AND TERMINATION OF THE
 GAS VENTS PER FBC-2004 FUEL GAS CODE
 SECS. 502 THRU 505.
  
 D. SUBMIT MANUFACTURE SHEETS FOR ALL GAS
 EQUIPMENT TO VERIFY COMPLIANCE WITH
 STANDARDS NFPA 54, NFPA 58, AND THE
 FBC-2004 FUEL GAS CODE SEC 402.2.
  
 E. EMERGENCY HOOD SHUT DOWN SHUT OFF
 VALVE TO BE BELOW CEILING. MANUAL SHUT
 OFF VALVE TO BE UPSTREAM. UNION TO BE
 DOWN STREAM OF MANUAL VALVE.
  
 2. SHT P501 GAS INSTANT WATER HEATER PIPING SCHEMATIC.
 THE DIRT LEGS SHALL BE DOWNSTREAM OF THE GAS SHUT OFF
 VALVES. SECTION 408.4.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUM-
 BER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICA
 TION PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK
 YOU FOR YOUR ANTICIPATED COOPERATION.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 805-6731
 E-MAIL [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 18 Status N Date 2007-12-03 Cont ID  
Sent By adarroug Date 2007-12-03 Time 09:35 Rev Time 0.00
Received By adarroug Date 2007-12-03 Time 09:35 Sent To E
Notes
2007-12-03 09:35:44TO "DPALMER" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 17 Status N Date 2007-11-16 Cont ID  
Sent By adarroug Date 2007-11-16 Time 10:53 Rev Time 0.00
Received By adarroug Date 2007-11-16 Time 10:53 Sent To P
Notes
2007-11-16 12:21:18PLANS WERE TAKEN FROM KEN STEVENS DESK AND ROUTED TO
 "COMM" BD#3
2007-11-16 10:54:20TO "KSTEVENS" DESK/REVISION--EXPEDITED--

Review Stop I INCOMING/PROCESSING
Rev No 16 Status N Date 2007-11-16 Cont ID  
Sent By adarroug Date 2007-11-16 Time 10:34 Rev Time 0.00
Received By adarroug Date 2007-11-16 Time 10:34 Sent To  
Notes
2007-11-16 10:34:34TO "COMM" BD#3--EXPEDITED PERMIT--

Review Stop I INCOMING/PROCESSING
Rev No 15 Status N Date 2007-11-08 Cont ID  
Sent By adarroug Date 2007-11-08 Time 16:03 Rev Time 0.00
Received By adarroug Date 2007-11-08 Time 16:03 Sent To  
Notes
2007-11-09 08:42:40TO "COMM" BD#38
2007-11-08 16:03:30WAITING FOR "COMM" BD--EXPEDITED PERMIT--

Review Stop I INCOMING/PROCESSING
Rev No 14 Status N Date 2007-10-29 Cont ID  
Sent By adarroug Date 2007-10-29 Time 17:04 Rev Time 0.00
Received By adarroug Date 2007-10-29 Time 17:04 Sent To B
Notes
2007-10-29 17:05:04TO "JWITMER" DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 13 Status N Date 2007-10-16 Cont ID  
Sent By adarroug Date 2007-10-16 Time 08:38 Rev Time 0.00
Received By adarroug Date 2007-10-16 Time 08:38 Sent To  
Notes
2007-10-16 08:38:46TO "COMM" BD#10

Review Stop I INCOMING/PROCESSING
Rev No 12 Status N Date 2007-09-25 Cont ID  
Sent By adarroug Date 2007-09-25 Time 16:58 Rev Time 0.00
Received By adarroug Date 2007-09-25 Time 16:58 Sent To B
Notes
2007-09-25 16:58:30TO "JWITMER" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 11 Status N Date 2007-09-21 Cont ID  
Sent By adarroug Date 2007-09-21 Time 15:13 Rev Time 0.00
Received By adarroug Date 2007-09-21 Time 15:13 Sent To M
Notes
2007-09-21 15:13:23TO "M" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 10 Status N Date 2007-09-17 Cont ID  
Sent By adarroug Date 2007-09-17 Time 13:45 Rev Time 0.00
Received By adarroug Date 2007-09-17 Time 13:45 Sent To B
Notes
2007-09-17 13:45:44TO "JWITMER" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 9 Status N Date 2007-09-17 Cont ID  
Sent By adarroug Date 2007-09-17 Time 10:17 Rev Time 0.00
Received By adarroug Date 2007-09-17 Time 10:17 Sent To M
Notes
2007-09-17 10:18:43TO "M" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 8 Status N Date 2007-09-11 Cont ID  
Sent By adarroug Date 2007-09-11 Time 10:59 Rev Time 0.00
Received By adarroug Date 2007-09-11 Time 10:59 Sent To M
Notes
2007-09-11 10:59:49TO "M" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2007-09-05 Cont ID  
Sent By adarroug Date 2007-09-05 Time 11:27 Rev Time 0.00
Received By adarroug Date 2007-09-05 Time 11:27 Sent To M
Notes
2007-09-05 11:27:43TO "M" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2007-08-30 Cont ID  
Sent By adarroug Date 2007-08-30 Time 11:12 Rev Time 0.00
Received By adarroug Date 2007-08-30 Time 11:12 Sent To E
Notes
2007-08-30 11:12:29TO "DPALMER" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2007-08-30 Cont ID  
Sent By adarroug Date 2007-08-30 Time 11:07 Rev Time 0.00
Received By adarroug Date 2007-08-30 Time 11:07 Sent To G
Notes
2007-08-30 11:07:53TO "G"BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2007-08-14 Cont ID  
Sent By adarroug Date 2007-08-14 Time 08:39 Rev Time 0.00
Received By adarroug Date 2007-08-14 Time 08:39 Sent To  
Notes
2007-08-14 08:39:32TO "COMM" BD#55/PLANS ON RACK--EXPEDITED PERMIT--

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2007-07-13 Cont ID  
Sent By adarroug Date 2007-07-13 Time 08:21 Rev Time 0.00
Received By adarroug Date 2007-07-13 Time 08:21 Sent To  
Notes
2007-07-13 08:25:23TO "COMM" BD#47--EXPEDITED PERMIT---/PLANS ON RACK/5
 ROLLS AND 1 BOX

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-06-05 Cont ID  
Sent By adarroug Date 2007-06-05 Time 14:54 Rev Time 0.00
Received By adarroug Date 2007-06-05 Time 14:54 Sent To  
Notes
2007-06-05 14:54:40WAITING FOR "COMM" BD

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-05-17 Cont ID  
Sent By mawillia Date 2007-05-17 Time 10:32 Rev Time 0.00
Received By mawillia Date 2007-03-25 Time 14:00 Sent To  
Notes
2007-03-25 14:00:29TO "COMM" BD#64

Review Stop M MECHANICAL (A/C)
Rev No 9 Status N Date 2007-11-19 Cont ID  
Sent By rregueir Date 2007-11-19 Time 14:11 Rev Time 0.00
Received By rregueir Date 2007-11-19 Time 13:30 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 8 Status P Date 2007-11-02 Cont ID  
Sent By rregueir Date 2007-11-02 Time 09:40 Rev Time 0.00
Received By rregueir Date 2007-11-02 Time 09:16 Sent To PC
Notes
2007-11-02 09:27:04REVIEWED FOR CODE COMPLIANCE. FIELD VERIFICATION BY THE
 INSPECTION TEAM IS REQUIRED TO DETERMINE IF THIS SYSTEM
 IS APPLICABLE FOR THE CONDITIONS IN THE FIELD.
 NOTE: FBC 712.4.1.2 REQUIRES THAT A THROUGH-PENETRATIN
 FIRESTOP SYSTEM IN HORIZONTAL ASSEMBLIES MAINTAINS THE
 F AND T RATING OF THE ASSEMBLY BEING PENETRATED, BUT
 NOT LESS THAN 1 HOUR. THIS ASSEMBLY SHOWS A T RATING OF
 ZERO HOURS.
  
 IF YOU HAVE ANY QUESTIONS PLEASE CONTACT:
 RONALD J. REGUEIRO
 561.805.6719
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 7 Status P Date 2007-10-24 Cont ID  
Sent By hmoser Date 2007-10-24 Time 17:43 Rev Time 0.00
Received By hmoser Date 2007-10-24 Time 17:43 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 6 Status P Date 2007-09-14 Cont ID  
Sent By rregueir Date 2007-09-14 Time 14:41 Rev Time 0.00
Received By rregueir Date 2007-09-14 Time 14:36 Sent To  
Notes
2007-09-14 14:42:05REVISED M100 AND M101. REV.5

Review Stop M MECHANICAL (A/C)
Rev No 5 Status P Date 2007-09-06 Cont ID  
Sent By rregueir Date 2007-09-06 Time 17:10 Rev Time 0.00
Received By rregueir Date 2007-09-06 Time 16:31 Sent To PC
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2007-08-17 Cont ID  
Sent By rregueir Date 2007-08-17 Time 17:40 Rev Time 0.00
Received By rregueir Date 2007-08-17 Time 16:37 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status F Date 2007-07-16 Cont ID  
Sent By rregueir Date 2007-07-16 Time 15:16 Rev Time 0.00
Received By rregueir Date 2007-07-16 Time 14:11 Sent To  
Notes
2007-07-16 15:16:17---------------DENIED-----------------
  
 NOTE: AT THIS TIME ALL OUTSTANDING MECHANICAL PLAN
 REVIEW COMMENTS HAVE BEEN ADEQUATELY ADDRESSED.
 HOWEVER, SOME CORRECTIONS ARE NEEDED TO THE ENERGY
 CALCULATIONS.
  
 1. PLEASE INDICATE ON THE PROJECT SUMMARY THE MAX
 TONNAGE SHOULD INDICATE THE LARGEST PIECE OF EQUIPMENT
 SERVING THE SPACE.
  
 2. AT LEAST 2 COPIES OF THE ENERGY CALCULATIONS SHALL
 BE PROVIDED WITH THE PLANS THAT CONTAIN ORIGINAL
 SIGNATURES AND SEALS PER FBC 13-103.1.1.1 AND SHALL BE
 SIGNED BY THE BUILDING OWNER OR OWNER'S AGENT PER FBC
 13-103.1.2
  
 3. THE INPUT DATA REPORT SHOWS MATERIALS AND TYPES OF
 CONSTRUCTION WHICH DO NOT APPLY TO THIS PROJECT.
 EXAMPLES: METAL SIDING W/ R-11 BATTS AND 1/2" GYP BD IS
 LISTED UNDER WALL TYPE, METAL BLDG ROOF W/ R-19 BATTS
 IS LISTED FOR ROOF TYPE, ALUMINUM POLYSTYRENE-FILLED
 DOORS ARE SHOWN AS DOOR TYPE.
 PLEASE USE DATA WHICH ACCURATELY REFLECTS THE
 CONSTRUCTION MATERIALS WHICH ARE IN PLACE AND WHICH
 ACCURATELY REFLECT THE R-VALUES AS THEY ACTUALLY OCCUR
 IN THE BUILDING.
  
 RONALD J REGUEIRO
 561.805.6719
 [email protected]

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2007-06-07 Cont ID  
Sent By rregueir Date 2007-06-07 Time 10:50 Rev Time 0.00
Received By rregueir Date 2007-06-07 Time 10:42 Sent To  
Notes
2007-06-07 10:50:37---------------DENIED---------------
 *2ND REVIEW*
  
 THE FOLLOWING COMMENTS ARE NUMBERED TO CORRESPOND WITH
 PREVIOUS COMMENTS FOR CONTINUITY.
  
 1. OK
  
 2. OK
  
 3. GENERAL NOTE #40 STILL STATES "ALL... DUCTWORK SHALL
 BE GALVANIZED STEEL, WRAPPED WITH 2"..." THIS IS IN
 CONFLICT WITH NOTES AND DETAILS SHOWING THE USE OF FLEX
 DUCT. PLEASE CLARIFY.
  
 4. OK
  
 5. EXAMPLE: AHU-6 IS LOCATED ABOVE PRIVATE DINING ROOM
 105. FINISH SCHEDULE ON A-600 SHOWS A GYPSUM CEILING.
 CLEARANCES AROUND APPLIANCES TO ELEMENTS OF PERMANENT
 CONSTRUCTION, INCLUDING OTHER INSTALLED EQUIPMENT AND
 APPLIANCES, SHALL BE SUFFICIENT TO ALLOW INSPECTIONS,
 SERVICE, REPAIR OR REPLACEMENT WITHOUT REMOVING SUCH
 ELEMENTS OF PERMANENT CONSTRUCTION OR DISABLING THE
 FUNCTION OF A REQUIRED FIRE RESISTANCE-RATED ASSEMBLY.
 FBC,M 306.1
  
 6. CONTINUATION OF DUCTWORK ON M100 APPEARS TO BE FROM
 AHU-5, NOT AHU-4. THE QUESTIONS RELATED TO AHU-4 IN
 PREVIOUS COMMENT HAVE NOT BEEN ADDRESSED.
  
 7. OK
  
 8. OK
  
 9. NOT CORRECTED. DROPS WERE CIRCLED DURING THIS REVIEW
 ON ONE SET OF PLANS FOR CLARIFICATION OF THE REVIEW
 COMMENT.
  
 10. OK
  
 IF YOU HAVE ANY QUESTIONS PLEASE CONTACT:
  
 RONALD J REGUEIRO
 561.805.6719
 [email protected]

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2007-04-23 Cont ID  
Sent By rregueir Date 2007-04-23 Time 16:28 Rev Time 0.00
Received By rregueir Date 2007-04-21 Time 14:43 Sent To  
Notes
2007-04-23 16:28:38----------------DENIED--------------------
  
 FBC 2004 CODE FAMILY W/ 2006 REVISIONS
 FBC CH 1 AS AMENDED BY THE CITY OF WEST PALM BEACH
 NFPA 90A
 NFPA 96
 ASHRAE 62.1-2004
  
 1. M001 GENERAL NOTE #15: AIR CONDITIONING CONDENSATE
 SHALL NOT BE DISCHARGED INTO WASTE WATER PIPING PER
 W.P.B. MUNICIPAL CODE SEC 90-125(B)(5)
  
 2. M001: GENERAL NOTE #31 IS IN CONFLICT WITH DETAIL
 DRAWINGS ON M002. PLEASE COORDINATE NOTES AND DETAILS
 ON 0DRAWINGS. FBC 106.1.1
  
 3. M001: GENERAL NOTE #40 IS IN CONFLICT WITH GENERAL
 NOTE #31 AND DETAILS ON M002. PLEASE COORDINATE NOTES
 AND DETAILS ON DRAWINGS. FBC 106.1.1
  
 4. M101 VENTILATION TABLE: PLEASE REFERENCE CORRECT
 ASHRAE STANDARD TO BE USED IN DETERMINING VENTILATION
 REQUIREMENTS: ASHRAE 62.1-2004 PER FBC,M 304.3.
  
 5. M101: EQUIPMENT OVER HARD CEILINGS REQUIRE ACCESS
 AND SERVICE SPACE PER FBC,M 306.1 AND 306.3.
  
 6. M101: AHU 4 RETURN DUCT SHOWS A RETURN OPENING ON
 SIDE OF 36X16 DUCT. DOES THIS HAVE A MOTORIZED AND
 MANUAL DAMPER? WHAT IS THE SIZE OF THE OPENING? HOW
 MANY CFM OF RETURN? IS THIS SPACE TO BE USED AS A
 PLENUM? IF SO, EXHAUST DUCTS UNDER POSITIVE PRESSURE
 SHALL NOT BE LOCATED IN A PLENUM PER FBC,M 601.3.
  
 7. M101: OA DUCT FOR AHU 7 APPEARS TO BE MARKED AS 10'
 ROUND AND 12" ROUND. PLEASE CLARIFY.
  
 8. M101 OA DUCT FOR AHU 6: PLEASE SHOW SIZE OF OA DUCT
 FOR AHU 6 ON PLANS.
  
 9. M101 AHU 2: THERE ARE 4 DROPS MISSING CFM, 3 OF THEM
 ARE ALSO MISSING SIZE. PLEASE CLARIFY.
  
 10. M100 WALK-IN COOLER CONDENSERS: BY WHAT MEANS WILL
 COPPER LINES FOR WALK-INS BE ROUTED INTO BUILDING?
 PLEASE PRIVIDE DETAILED INSTRUCTIONS. REFRIGERANNT
 PIPING TO COMPLY WITH FBC,M 1107.2.1
  
 NOTE: SEPARATE PERMITS REQUIRED FOR KITCHEN HOODS, HOOD
 SUPPRESSION SYSTEMS AND WALK-IN COOLERS/FREEZERS.
  
  
 ANY QUESTIONS PLEASE CONTACT:
 RONALD J REGUEIRO
 561,805.6719
 [email protected]

Review Stop P PLUMBING
Rev No 5 Status P Date 2007-11-24 Cont ID  
Sent By kstevens Date 2007-11-24 Time 15:49 Rev Time 0.00
Received By kstevens Date 2007-11-24 Time 15:49 Sent To  
Notes
2007-11-24 15:53:07REVISIONS OK - SHTS P302, P303, P304 & FS SHEETS FOR
 PLUMBING & GAS PIPING CHANGES (SANT & WATER)

Review Stop P PLUMBING
Rev No 4 Status P Date 2007-08-21 Cont ID  
Sent By kstevens Date 2007-08-21 Time 10:14 Rev Time 0.00
Received By kstevens Date 2007-08-20 Time 19:00 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status F Date 2007-08-10 Cont ID  
Sent By kstevens Date 2007-08-10 Time 08:14 Rev Time 0.00
Received By kstevens Date 2007-08-08 Time 18:58 Sent To  
Notes
2007-08-10 07:31:41DENIED
 REFERENCE: FBC-2004 PLUMBING
 FBC-2004 FUEL GAS
 FBC-2004 BUILDING
 FBC-2004 CHAPTER 1
 FBC-2004 CHAPTER 11
 WPB MUNICIPAL CODE
 FLORIDA ADMINISTRATIVE CODE
 FLORIDA STATUTES
  
 ******FROM PREVIOUS REVIEW:
 ****FROM PREVIOUS REVIEWS:
  
 1. ROUTE PLANS TO THE DEPARTMENT OF BUSINESS
 REGULATION, HOTEL & RESTAURANT DIVISION FOR PLAN
 REVIEW. A MINIMUM OF TWO SETS OF PLANS WITH STAMPED
 SHEETS FROM DBPR WITH THE TWO PAGE "WORKSHEETS"
 ATTACHED TO THE STAMPED SHEET SHALL BE RESUBMITTED FOR
 REVIEW. SECTION 102.2.1.
 ******NO RESPONSE/NOT ADDRESSED
 ****RESPONSE NOTED, BUT THE STAMPED DBPR SHEETS WERE
 NOT INCLUDED IN THE NEW SETS OF PLANS AND NO TWO PAGE
 "WORKSHEETS" WERE ATTACHED TO THE STAMPED SHEETS.
  
 2. OK
 3. OK
 4. OK
 5. OK
 6. OK
  
 7. SHT A400 SHOW COMPLIANCE WITH THE FOLLOWING: __FOR
 URINAL
 A. OK
 B. OK
 C. 11-4.18.4 FLUSH CONTROLS
 ******NOT ADDRESSED.
 ****RESPONSE NOTED, BUT URINAL FLUSH CONTROL HEIGHT NOT
 INDICATED.
  
  
 8.OK
 9.OK
 10. OK
 11. OK
 12. OK
  
 13. ALL MECHANICAL & PLUMBING SHEETS. THE ENGINEERS
 SIGNATURE IS REQUIRED ON EACH SHEET. IT APPEARS THAT
 INITIALS HAVE BEEN USED. IF INDEED THIS IS THE LEGAL
 SIGNATURE, A SIGNED, SEALED, NOTORIZED LETTER
 INDICATING THE LEGAL SIGNATURE SHALL BE SUBMITTED FOR
 OUR FILES. FAC 61G15-23.002(1)(2) & FS 471.025.
 ******RESPONSE NOTED. THIS WILL BE REQUIRED PRIOR TO
 PERMIT BEING ISSUED.
 ****RESPONSE NOTED, BUT LETTER STILL NOT SUBMITTED.
  
 14. OK
 15. OK
 16. OK
  
 17. SHT P301 PLUMBING/WASTE SCHEDULE. SHOW ALL MARK
 DESIGNATIONS ON THE ENLARGED KITCHEN WASTE PLAN THAT
 CORRELATES WITH THE SCHEDULE. AT THIS POINT THE KITCHEN
 EQUIPMENT CAN NOT BE IDENTIFIED WITHOUT MARK
 DESIGNATIONS. SECTION 106.1.1.
 ******RESPONSE NOTED, BUT THE FOLLOWING ITEMS WERE NOT
 LOCATED ON THE FLOOR PLAN. P6A, P16, P11, P12A, P13A,
 P14, P14.1, P14A, P14B, P15A, P17A P47B, P150 & P150A.
 PLEASE CORRELATE FLOOR PLAN WITH PLUMBING/WASTE
 SCHEDULE
 ****RESPONSE NOTED, BUT ITEM P6A NOT FOUND.
  
 18. OK
 19. OK
 20. OK
 21. OK
 22. OK
 23. OK
 24. OK
 25. OK
 26. OK
 27. OK
 28. OK
 29. OK
  
 30. SHT P402 THE FOLLOWING IS REQUIRED FOR THE GAS
 PERMIT APPROVAL:
  
 A. SUBMIT AN ISOMETRIC DRAWING THAT
 CLEARLY SHOWS ALL CUT SECTIONS OF PIPE
 AND CORRESPONDING LENGTHS PER FBC-2004
 FUEL GAS CODE.
 ******RESPONSE NOTED, BUT A CLARIFICATION IS REQUIRED
 ON THE DROP WITH THE SOLENOID VALVE. THE TOTAL LENGTH
 IS INDICATED AS 3'0", (1'0" +2'0").
 ****RESPONSE NOTED, BUT THE PIPE SIZING THRU THE SHUT
 OFF VALVE FOR EACH GAS APPLIANCE SHALL BE FULL SIZE PER
 TABLE 402.4(2) AND INDICATED ON THE ISOMETRIC. ALSO
 EACH APPLIANCE SHALL PROVIDED WITH A SHUT OFF VALVE PER
 SECTION 409.5. ONLY ONE SUPPLY LINE WITH ONE SHUT OFF
 VALVE IS INDICATED FOR TWO FRYERS. PLEASE CORRECT THE
 GAS RISER DIAGRAM.
  
 B. OK
 C. OK
 D. OK
 E. OK
 31. OK
 32. OK
 33. OK
 34. OK
 35. OK
  
 36. TO HELP EXPEDITE PLAN REVIEW, PLEASE RESUBMIT THE
 MARKED UP PLUMBING PLANS ALONG WITH THE NEW PLANS.
 *******NO RESPONSE, NOT ADDRESSED.
 ****RESPONSE NOTED, BUT NO MARKED UP PLUMBING PLANS
 FOUND.
  
 **********NEW COMMENTS**********
  
 1B. IT APPEARS THAT NEW SHEETS WERE INSERTED INTO THE
 OLD PLANS. PLEASE MAKE SURE THE NEWEST REVISED SHEETS
 ARE SUBMITTED IN THE NEW SETS OF PLANS FOR REVIEW.
 SECTION 106.1.1.
  
 2B. SHT FS-5 PLUMBING/GAS SCHEDULE GK113 INDICATES QTY
 AS "LOT" BUT MANUF SPECIFICATION SHEET COVER SHEET
 INDICATES QUANTITY AS TWO FRYERS. PLEASE CLARIFY.
 SECTION 106.1.1.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUM-
 BER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICA
 TION PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK
 YOU FOR YOUR ANTICIPATED COOPERATION.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 805-6731
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 2 Status F Date 2007-06-07 Cont ID  
Sent By kstevens Date 2007-06-07 Time 17:26 Rev Time 0.00
Received By kstevens Date 2007-06-07 Time 17:26 Sent To  
Notes
2007-06-07 17:29:14DENIED
 REFERENCE: FBC-2004 PLUMBING
 FBC-2004 FUEL GAS
 FBC-2004 BUILDING
 FBC-2004 CHAPTER 1
 FBC-2004 CHAPTER 11
 WPB MUNICIPAL CODE
 FLORIDA ADMINISTRATIVE CODE
 FLORIDA STATUTES
  
 ******FROM PREVIOUS REVIEW:
  
 1. ROUTE PLANS TO THE DEPARTMENT OF BUSINESS
 REGULATION, HOTEL & RESTAURANT DIVISION FOR PLAN
 REVIEW. A MINIMUM OF TWO SETS OF PLANS WITH STAMPED
 SHEETS FROM DBPR WITH THE TWO PAGE "WORKSHEETS"
 ATTACHED TO THE STAMPED SHEET SHALL BE RESUBMITTED FOR
 REVIEW. SECTION 102.2.1.
 ******NO RESPONSE/NOT ADDRESSED
  
 2. GREASE INTERCEPTORS SHALL BE SIZED AND INSPECTED BY
 ENVIRONMENTAL COMPLIANCE. PLEASE CONTACT RODNEY COMPO
 (561) 822-2272 OR CALVIN WILLIAMS(561) 822-2284.
 THEIR FAX NUMBER IS (561) 822-2287. E-MAIL
 [email protected]@WPB.ORG. PLEASE INDICATE
 THEIR RESPONSE. ARTICLE III 90-124(7). ******WAITING
 FOR REPLY FROM C. WILLIAMS. WILL TRY TO ADDRESS ISSUE
 AT THIS END.
  
 3. OK
 4. OK
 5. OK
  
 6. SHT A400 DETAILS 1 & 2 GRAB BARS FOR THE WATER
 CLOSETS AT THE SIDE SHALL BE 42". SEE FIG 11-30E.--
 DETAIL 4 SHOW THE WATER CLOSET TO BE 1'7" OFF THE WALL
 TO THE CENTERLINE OF THE FIXTURE. 1'6" IS REQUIRED. SEE
 FIG 11-30E.7.
 ******RESPONSE NOTED, NOT ADDRESSED
  
 7. SHT A400 SHOW COMPLIANCE WITH THE FOLLOWING: __FOR
 URINAL
 A. OK
 B. OK
 C. 11-4.18.4 FLUSH CONTROLS
 ******NOT ADDRESSED
 __FOR LAVS
 A MINIMUM 1 LAV OUTSIDE THE ACCESSIBLE STALL SHALL
 COMPLY WITH SECTION 11-4.19 AND ALL SUBSECTIONS.
 FORWARD APPROACH REQUIRED AND SHALL EXTEND UNDERNEATH
 THE LAV A MINIMUM 19" PLEASE SUBMIT A DETAIL FOR THE
 ACCESSIBLE LAV OUTSIDE THE ACCESSIBLE STALL.
 ******RESPONSE NOTED, BUT PER SECTION 11-4.19.1 ALL
 LAVS SHALL BE ACCESSIBLE.
  
 8. SHT A401 DETAILS 1 & 2 FORWARD APPROACH REQUIRED FOR
 THE CLEAR FLOOR SPACE FOR AT LEAST ONE LAV OUTSIDE THE
 ACCESSIBLE STALL PER SECTION 11-419.3. ******RESPONSE
 NOTED, BUT PER SECTION 11-4.19.1 ALL LAVS SHALL BE
 ACCESSIBLE.
  
 9.OK
 10. OK
 11. OK
 12. OK
  
 13. ALL MECHANICAL & PLUMBING SHEETS. THE ENGINEERS
 SIGNATURE IS REQUIRED ON EACH SHEET. IT APPEARS THAT
 INITIALS HAVE BEEN USED. IF INDEED THIS IS THE LEGAL
 SIGNATURE, A SIGNED, SEALED, NOTORIZED LETTER
 INDICATING THE LEGAL SIGNATURE SHALL BE SUBMITTED FOR
 OUR FILES. FAC 61G15-23.002(1)(2) & FS 471.025.
 ******RESPONSE NOTED. THIS WILL BE REQUIRED PRIOR TO
 PERMIT BEING ISSUED.
  
 14. OK
 15. OK
 16. OK
  
 17. SHT P301 PLUMBING/WASTE SCHEDULE. SHOW ALL MARK
 DESIGNATIONS ON THE ENLARGED KITCHEN WASTE PLAN THAT
 CORRELATES WITH THE SCHEDULE. AT THIS POINT THE KITCHEN
 EQUIPMENT CAN NOT BE IDENTIFIED WITHOUT MARK
 DESIGNATIONS. SECTION 106.1.1.
 ******RESPONSE NOTED, BUT THE FOLLOWING ITEMS WERE NOT
 LOCATED ON THE FLOOR PLAN. P6A, P16, P11, P12A, P13A,
 P14, P14.1, P14A, P14B, P15A, P17A P47B, P150 & P150A.
 PLEASE CORRELATE FLOOR PLAN WITH PLUMBING/WASTE
 SCHEDULE.
  
 18. OK
  
 19. SHT P301 PLUMBING/WATER SCHEDULE ITEMS P31-C &
 P39-F INDICATE A WATER FILTER. WATER FILTERS MUST MEET
 THE REQUIREMENTS OF NSF 42. PLEASE SUBMIT MANUF
 SPECIFICATION SHEETS SHOWING COMPLIANCE. SECTION
 611.1.
 ******RESPONSE NOTED, BUT NOT ADDRESSED
  
 20. SHT P301 PLUMBING/WATER SCHEDULE. MARK P33-F
 INDICATES QTY 4, BUT ONLY 2 WERE FOUND. PLEASE CLARIFY.
 SECTION 106.1.1.
 ******RESPONSE NOTED, BUT SCHEDULE NOT CHANGED.
  
 21. OK
  
 22. SHT P302 IDENTIFY ALL FIXURES/APPLIANCES TO REFLECT
 THE MARK NUMBERS INDICATED ON THE PLUMBING/WASTE
 SCHEDULE. MORE INFORMATION IS REQUIRED SECTION
 106.2.1.
 ******RESPONSE NOTED, BUT SOME MARK NUMBER ARE NOT
 INDICATED ON THE FLOOR PLANS. (SEE COMMENT 17).
  
 23. OK
 24. OK
  
 25. SHT P401. DOMESTIC WATER RISER DIAGRAM DOES NOT
 REFLECT THE FLOOR PLAN FOR FIXTURES P88-C, P36-C -
 P36-H, (BY P98) & P55-H. PLEASE CORRELATE THE RISER AND
 FLOOR PLAN INFORMATIONS. SECTION 106.1.1.
 ******RESPONSE NOTED, BUT FIXTURE P88-C PIPING ON THE
 RISER DIAGRAM STILL DOES NOT REFLECT THE FLOOR PLAN.
  
 26. OK
 27. OK
 28. OK
 29. OK
  
 30. SHT P402 THE FOLLOWING IS REQUIRED FOR THE GAS
 PERMIT APPROVAL:
  
 A. SUBMIT AN ISOMETRIC DRAWING THAT
 CLEARLY SHOWS ALL CUT SECTIONS OF PIPE
 AND CORRESPONDING LENGTHS PER FBC-2004
 FUEL GAS CODE.
 ******RESPONSE NOTED, BUT A CLARIFICATION IS REQUIRED
 ON THE DROP WITH THE SOLENOID VALVE. THE TOTAL LENGTH
 IS INDICATED AS 3'0", (1'0" +2'0").
  
 B. SHOW THE DISTANCE FROM THE POINT OF
 DELIVERY, (METER), TO THE MOST REMOTE
 OUTLET IN THE BUILDING AND/OR SYSTEM PER
 FBC-2004 FUEL GAS CODE APPENDIX A - USE
 OF CAPACITY TABLES A.3.1(4).
 ******RESPONSE NOTED, BUT DISTANCE SHALL BE VERIFIED
 WHEN COMMENT "A" CLARIFIED.
  
 C. OK
  
 D. SUBMIT MANUFACTURE SHEETS FOR ALL GAS
 EQUIPMENT TO VERIFY COMPLIANCE WITH
 STANDARDS NFPA 54, NFPA 58, AND THE
 FBC-2004 FUEL GAS CODE SEC 402.2.
 ******RESPONSE NOTED, NOT ADDRESSED.
  
 E. EMERGENCY HOOD SHUT DOWN SHUT OFF
 VALVE TO BE BELOW CEILING. MANUAL SHUT
 OFF VALVE TO BE UPSTREAM. UNION TO BE
 DOWN STREAM OF MANUAL VALVE.
 ******RESPONSE NOTED, BUT NOT COMPLETLY ADDRESSED. NO
 MANUAL SHUT OFF VALVE UPSTREAM OF THE SOLENOID VALVE
 AND NO UNION INDICATED.
  
 31. OK
 32. OK
 33. OK
 34. OK
 35. OK
  
 36. TO HELP EXPEDITE PLAN REVIEW, PLEASE RESUBMIT THE
 MARKED UP PLUMBING PLANS ALONG WITH THE NEW PLANS.
 *******NO RESPONSE, NOT ADDRESSED
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUM-
 BER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICA
 TION PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK
 YOU FOR YOUR ANTICIPATED COOPERATION.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 805-6731
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 1 Status F Date 2007-05-09 Cont ID  
Sent By kstevens Date 2007-05-09 Time 09:45 Rev Time 0.00
Received By kstevens Date 2007-05-09 Time 09:45 Sent To  
Notes
2007-05-09 12:25:36DENIED
 REFERENCE: FBC-2004 PLUMBING
 FBC-2004 FUEL GAS
 FBC-2004 BUILDING
 FBC-2004 CHAPTER 1
 FBC-2004 CHAPTER 11
 WPB MUNICIPAL CODE
 FLORIDA ADMINISTRATIVE CODE
 FLORIDA STATUTES
  
 1. ROUTE PLANS TO THE DEPARTMENT OF BUSINESS
 REGULATION, HOTEL & RESTAURANT DIVISION FOR PLAN
 REVIEW. A MINIMUM OF TWO SETS OF PLANS WITH STAMPED
 SHEETS FROM DBPR WITH THE TWO PAGE "WORKSHEETS"
 ATTACHED TO THE STAMPED SHEET SHALL BE RESUBMITTED FOR
 REVIEW. SECTION 102.2.1.
  
 2. GREASE INTERCEPTORS SHALL BE SIZED AND INSPECTED BY
 ENVIRONMENTAL COMPLIANCE. PLEASE CONTACT RODNEY COMPO
 (561) 822-2272 OR CALVIN WILLIAMS(561) 822-2284.
 THEIR FAX NUMBER IS (561) 822-2287. E-MAIL
 [email protected]@WPB.ORG. PLEASE INDICATE
 THEIR RESPONSE. ARTICLE III 90-124(7).
  
 3. ALL SHEETS WITH AOA ASSOCIATES TITLE BLOCK. THE
 ARCHITECTS BUSINESS NUMBER, (CERTIFICATE OF
 AUTHORIZATION), IS REQUIRED IN THE TITLE BLOCK OF EACH
 SHEET. FAC 61G1-16.004(2) & FS 481.219, 481.2055.
  
 4. SHT T101 INDEX OF DRAWINGS DOES NOT REFLECT THE
 SHEETS SUBMITTED. SHEETS M101 & P402 ARE NOT SHOWN ON
 THE INDEX. SHTS M102, M301, M302, M303 & E100 ARE SHOWN
 ON THE INDEX BUT NOT SUBMITTED. PLEASE CORRELATE THE
 INDEX WITH SHEETS SUBMITTED. SECTION 106.1.1.
  
 5. SHT T101 APPLICABLE CODES ACCESSIBILITY INDICATES
 2001. WE HAVE SINCE ADPOTED THE FBC-2004 ACCESSIBLITY
 CODE. (CHAPTER 11). PLEASE CHANGE CODE REFERENCE.
  
 6. SHT A400 DETAILS 1 & 2 GRAB BARS FOR THE WATER
 CLOSETS AT THE SIDE SHALL BE 42". SEE FIG 11-30E.--
 DETAIL 4 SHOW THE WATER CLOSET TO BE 1'7" OFF THE WALL
 TO THE CENTERLINE OF THE FIXTURE. 1'6" IS REQUIRED. SEE
 FIG 11-30E.7.
  
 7. SHT A400 SHOW COMPLIANCE WITH THE FOLLOWING: __FOR
 URINAL
 A. 11-4.18.2 HEIGHT
 B. 11-4.18.3 CLEAR FLOOR SPACE
 C. 11-4.18.4 FLUSH CONTROLS
 __FOR LAVS
 A MINIMUM 1 LAV OUTSIDE THE ACCESSIBLE STALL SHALL
 COMPLY WITH SECTION 11-4.19 AND ALL SUBSECTIONS.
 FORWARD APPROACH REQUIRED AND SHALL EXTEND UNDERNEATH
 THE LAV A MINIMUM 19" PLEASE SUBMIT A DETAIL FOR THE
 ACCESSIBLE LAV OUTSIDE THE ACCESSIBLE STALL.
  
 8. SHT A401 DETAILS 1 & 2 FORWARD APPROACH REQUIRED FOR
 THE CLEAR FLOOR SPACE FOR AT LEAST ONE LAV OUTSIDE THE
 ACCESSIBLE STALL PER SECTION 11-419.3.
  
 9. SHT A600 ROOM 113 EMPLOYEES RESTROOM CALLS FOR BCT-1
 FOR THE FLOOR. THE FINISH KEY SHT A602 DOES NOT
 INDICATE WHAT BCT-1 REPRESENTS. PLEASE CLARIFY.
 SECTIONS 106.1.1 & 1210.1.
  
 10. SHT A600 FINISH SCHEDULE FOR ROOMS 110 & 111 STATE
 "SEE EL" FOR THE BASE, BUT THE BASE FOR THE WALLS BY
 THE W/C'S & URINALS DO NOT INDICATE THE MATERIAL FOR
 THE BASE. PLEASE CLARIFY. SECTIONS 106.1.1 & 1210.1.
  
 11. SHT A600 WALLS FOR THE W/C'S AND URINALS IN ROOMS
 110 & 111 INDICATE CT-3 ON THE ELEVATIONS, BUT CT-3 IS
 NOT INDICATED ON THE FINISH SCHEDULE. PLEASE CLARIFY.
 SECTIONS 106.1.1. & 1210.2.
  
 12. SHT A600 ROOM 113 WALLS CALL FOR PT-1B. SECTION
 1210.2 CALLS FOR A SMOOTH, HARD, NONABSORBENT SURFACE
 WITHIN 2' OF THE W/C. PAINT DOES NOT COMPLYWITH
 REQUIREMENT FOR A HARD SURFACE. PLEASE SHOW
 COMPLIANCE.
  
 13. ALL MECHANICAL & PLUMBING SHEETS. THE ENGINEERS
 SIGNATURE IS REQUIRED ON EACH SHEET. IT APPEARS THAT
 INITIALS HAVE BEEN USED. IF INDEED THIS IS THE LEGAL
 SIGNATURE, A SIGNED, SEALED, NOTORIZED LETTER
 INDICATING THE LEGAL SIGNATURE SHALL BE SUBMITTED FOR
 OUR FILES. FAC 61G15-23.002(1)(2) & FS 471.025.
  
 14. SHT P001 GENERAL NOTES #3. THE SANITARY PIPING
 SHALL BE INSTALLED PER TABLE 704.1. ALL PIPE 2-1/2" AND
 SMALLER SHALL BE SLOPED 1/4"/FT. PLEASE ADJUST NOTE TO
 REFLECT THIS REQUIREMENT.
  
 15. SHT P001 GENERAL NOTES #30. DIELECTRIC UNIONS ARE
 MANUF. FOR GAS SYSTEMS ONLY. FOR USE IN A WATER SYSTEM
 A DIELECTRIC COUPLING SHALL BE USED. PLEASE ADJUST NOTE
 TO REFLECT THIS REQUIREMENT.
  
 16. SUBMIT A SANITARY RISER DIAGRAM FOR THE PIPING TO
 THE SECOND FLOOR MECHANICAL ROOM. SECTION
 106.3.5.1.3(4)(6)(13).
  
 17. SHT P301 PLUMBING/WASTE SCHEDULE. SHOW ALL MARK
 DESIGNATIONS ON THE ENLARGED KITCHEN WASTE PLAN THAT
 CORRELATES WITH THE SCHEDULE. AT THIS POINT THE KITCHEN
 EQUIPMENT CAN NOT BE IDENTIFIED WITHOUT MARK
 DESIGNATIONS. SECTION 106.1.1.
  
 18. SHT P301. PLUMBING/WASTE SCHEDULE. P36-C & P36-H
 INDICATES QTY 6, BUT ONLY 5 WERE FOUND.PLEASE
 CORRELATE. SECTION 106.1.1.
  
 19. SHT P301 PLUMBING/WATER SCHEDULE ITEMS P31-C &
 P39-F INDICATE A WATER FILTER. WATER FILTERS MUST MEET
 THE REQUIREMENTS OF NSF 42. PLEASE SUBMIT MANUF
 SPECIFICATION SHEETS SHOWING COMPLIANCE. SECTION
 611.1.
  
 20. SHT P301 PLUMBING/WATER SCHEDULE. MARK P33-F
 INDICATES QTY 4, BUT ONLY 2 WERE FOUND. PLEASE CLARIFY.
 SECTION 106.1.1.
  
 21. SHT P301 PLUMBING/GAS SCHEDULE. PK104 DESCRIPTION &
 REMARKS INDICATED A GAS DROP BY THE GENERAL CONTRACTOR.
 ALL GAS WORK SHALL BE BY THE PLUMBING CONTRACTOR.
 PLEASE CHANGE REFERENCE. FS 489.105(M).
  
 22. SHT P302 IDENTIFY ALL FIXURES/APPLIANCES TO REFLECT
 THE MARK NUMBERS INDICATED ON THE PLUMBING/WASTE
 SCHEDULE. MORE INFORMATION IS REQUIRED SECTION
 106.2.1.
  
 23. SHT P302 THE DISHWASHER, (ITEM 55 ON SHT P301),
 SHALL CONNECT TO THE SANITARY SYSTEM, NOT THE GREASE
 SYSTEM. CITY CODE ARTICLE III SECTION 90-124(7)(B).
 PLEASE CHANGE FLOOR PLAN PIPING.
  
 24. SHT P304 BAR SANITARY/WASTE PLAN. DRY HORIZONTAL
 VENTS ARE PROHIBITED. SECTION 905.3. EVERY DRY VENT
 CONNECTING TO A HORIZONTAL DRAIN SHALL CONNECT ABOVE
 THE CENTERLINE OF THE HORIZONTAL DRAIN PIPE. ALSO SEE
 SECTION 905.4.
  
 25. SHT P401. DOMESTIC WATER RISER DIAGRAM DOES NOT
 REFLECT THE FLOOR PLAN FOR FIXTURES P88-C, P36-C -
 P36-H, (BY P98) & P55-H. PLEASE CORRELATE THE RISER AND
 FLOOR PLAN INFORMATIONS. SECTION 106.1.1.
  
 26. SHT P401 FULL OPEN VALVES ARE REQUIRED ON THE WATER
 SUPPLY PIPE TO EVERY W/H. SECTION 606.1(7).
  
 27. SHT P401 A WATER HAMMER ARRESTOR IS REQUIRED ON THE
 WATER SUPPLY TO P55-H WHEN DRAWN ON THE RISER DIAGRAM.
 SECTION 604.9.
  
 28. SHT P402 KITCHEN WASTE& VENT RISER DIAGRAM. THE
 FLOOR SINK FOR THE DISH WASHER SHALL CONNECT TO THE
 SANITARY SYSTEM, NOT THE GREASE SYSTEM. ARTICLE III
 SECTION 90-124(7)(B). PLEASE CHANGE RISER DIAGRAM.
  
 29. SHT P402. BAR WASTE AND VENT RISER DIAGRAM. DRY
 HORIZONTAL VENTS ARE PROHIBITED. SECTION 905.3. EVERY
 DRY VENT CONNECTING TO A HORIZONTAL DRAIN SHALL CONNECT
 ABOVE THE CENTERLINE OF THE HORIZONTAL DRAIN PIPE. ALSO
 SEE SECTION 905.4.
  
 30. SHT P402 THE FOLLOWING IS REQUIRED FOR THE GAS
 PERMIT APPROVAL:
  
 A. SUBMIT AN ISOMETRIC DRAWING THAT
 CLEARLY SHOWS ALL CUT SECTIONS OF PIPE
 AND CORRESPONDING LENGTHS PER FBC-2004
 FUEL GAS CODE.
  
 B. SHOW THE DISTANCE FROM THE POINT OF
 DELIVERY, (METER), TO THE MOST REMOTE
 OUTLET IN THE BUILDING AND/OR SYSTEM PER
 FBC-2004 FUEL GAS CODE APPENDIX A - USE
 OF CAPACITY TABLES A.3.1(4).
  
 C. SUBMIT A DETAIL SHOWING THE TYPE,
 LOCATION, SIZE AND TERMINATION OF THE
 GAS VENTS PER FBC-2004 FUEL GAS CODE
 SECS. 502 THRU 505.
  
 D. SUBMIT MANUFACTURE SHEETS FOR ALL GAS
 EQUIPMENT TO VERIFY COMPLIANCE WITH
 STANDARDS NFPA 54, NFPA 58, AND THE
 FBC-2004 FUEL GAS CODE SEC 402.2.
  
 E. EMERGENCY HOOD SHUT DOWN SHUT OFF
 VALVE TO BE BELOW CEILING. MANUAL SHUT
 OFF VALVE TO BE UPSTREAM. UNION TO BE
 DOWN STREAM OF MANUAL VALVE.
  
 31. SHT P501 GAS INSTANT WATER HEATER PIPING SCHEMATIC.
 THE DIRT LEGS SHALL BE DOWNSTREAM OF THE GAS SHUT OFF
 VALVES. SECTION 408.4.
  
 32. SHT P501 FLOOR SINK DETAIL. THE AIR GAP SHALL BE A
 MINIMUM OF TWICE THE EFFECTIVE OPENING OF THE INDIRECT
 WASTE PIPE. SECTION 802.2.1.-- THE FLOOR SINK SHALL
 BE SET 1" ABOVE THE FINISHED FLOOR AS IT IS FOR
 INDIRECT WASTE ONLY, NOT A FLOOR DRAIN.PLEASE ADJUST
 THE FLOOR SINK DETAIL.
  
 33. SHT PD201 GENERAL NOTES #2 DEAD ENDS ARE
 PROHIBITED. ALL DEMO'D & CAPPED PIPING SHALL BE LEFT
 UNCOVERED UNTIL FIELD INSPECTOR'S APPROVAL. SECTION
 704.5.
  
 34. SHT PD201 GENERAL NOTES #3 & #10 HAVE NOT BEEN
 LOCATED. PLEASE CLARIFY. SECTION 106.1.1.
  
 35. SHT PD202 GENERAL NOTES #1 DEAD ENDS ARE
 PROHIBITED. ALL DEMO'D & CAPPED PIPING SHALL BE LEFT
 UNCOVERED UNTIL FIELD INSPECTOR'S APPROVAL. SECTION
 704.5.
  
 36. TO HELP EXPEDITE PLAN REVIEW, PLEASE RESUBMIT THE
 MARKED UP PLUMBING PLANS ALONG WITH THE NEW PLANS.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUM-
 BER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICA
 TION PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK
 YOU FOR YOUR ANTICIPATED COOPERATION.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 805-6731
 E-MAIL [email protected]
  

Review Stop Z ZONING
Rev No 1 Status P Date 2007-04-05 Cont ID  
Sent By eschneid Date 2007-04-05 Time 16:23 Rev Time 0.00
Received By eschneid Date 2007-04-05 Time 16:23 Sent To  
Notes
***NONE***