Plan Review Details - Permit 07030796
Plan Review Stops For Permit 07030796 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2007-05-09 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-05-09 |
Time |
11:01 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-05-09 |
Time |
11:01 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2007-04-21 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-04-21 |
Time |
14:03 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-04-21 |
Time |
14:03 |
Sent To |
|
|
Notes |
2007-04-21 14:11:03 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBCFLORIDA BUILDING CODE 2004 | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | CODE | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC* | | CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | FACFLORIDA ADMINISTRATIVE CODE | | FSFLORIDA STATUTE | | | | | | 1.)YOU HAVE USED EXPOSURE B PRESSURES, THIS IS | | EXPOSURE C.REVISE PRESSURES AND REVISE ANCHOR | | SCHEDULE AS NECESSARY.FOR INSTANCE, OPENING 5, END | | ZONE, HAS A MINIMUM DESIGN PRESSURE OF -48.16 FOR 50SF, | | END ZONE, EXPOSURE C.SEE HIGHLIGHTED PRODUCT | | APPROVAL, 11INCH SPACING REQUIRED.CHECK ALL | | OPENINGS. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2007-03-30 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-03-30 |
Time |
13:49 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-03-30 |
Time |
13:49 |
Sent To |
|
|
Notes |
2007-03-30 13:50:56 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBCFLORIDA BUILDING CODE 2004 | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | CODE | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL | | FBC*CITY OF WEST PALM BEACH AMENDMENTS TO THE | | FBC2004 | | FACFLORIDA ADMINISTRATIVE CODE | | FSFLORIDA STATUTE | | | | 1.)OPENING 1, 48 PSF, MUST USE THE 77PSF HOLLOW BLOCK | | CHART, SPAN UP TO 15' (OPENING IS OVER 9'), YOU SPECIFY | | ANCHOR SPACING ON THE BOTTOM OF 8" BUT THIS CONNECTION | | TYPE NOT ALLOWED FOR THIS SUBSTRATE AND CONNECTION | | DETAIL, SEE HIGHLIGHTED PLAN.CHECK ALL OPENINGS; | | THERE MAY BE OTHER ERRORS.PLEASE CONTACT ME IF YOU | | NEED ASSISTANCE. | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2007-05-07 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-05-07 |
Time |
14:40 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-05-07 |
Time |
14:40 |
Sent To |
B |
|
Notes |
2007-05-07 14:40:45 | TO "SHILL" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2007-04-30 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-04-30 |
Time |
16:23 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-04-30 |
Time |
16:23 |
Sent To |
B |
|
Notes |
2007-04-30 16:23:27 | TO "SHILL" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2007-04-18 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-04-18 |
Time |
10:58 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-04-18 |
Time |
10:58 |
Sent To |
B |
|
Notes |
2007-04-18 10:58:47 | TO "SHILL" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2007-03-30 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-03-30 |
Time |
13:51 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-03-24 |
Time |
15:04 |
Sent To |
|
|
Notes |
2007-03-24 15:04:57 | TO "MISC" BOX#1 |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |