Plan Review Details - Permit 07030752
Plan Review Stops For Permit 07030752
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2007-05-16 Cont ID  
Sent By lmartine Date 2007-05-16 Time 11:37 Rev Time 0.00
Received By lmartine Date 2007-05-16 Time 11:36 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-04-20 Cont ID  
Sent By shill Date 2007-04-20 Time 17:53 Rev Time 0.00
Received By shill Date 2007-04-20 Time 17:53 Sent To  
Notes
2007-04-20 17:54:34****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL
 FBC*CITY OF WEST PALM BEACH AMENDMENTS TO THE
 FBC2004
 FACFLORIDA ADMINISTRATIVE CODE
 FSFLORIDA STATUTE
  
  
  
  
 1.)FBC*106.1, TWO SETS OF ALL PERMIT DOCUMENTS
 REQUIRED.
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2007-05-09 Cont ID  
Sent By btrobaug Date 2007-05-09 Time 07:37 Rev Time 0.33
Received By btrobaug Date 2007-05-09 Time 07:16 Sent To G
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2007-03-28 Cont ID  
Sent By btrobaug Date 2007-03-28 Time 09:02 Rev Time 0.50
Received By btrobaug Date 2007-03-28 Time 08:30 Sent To M
Notes
2007-03-28 09:02:26 
  
 DENIED/INCOMPLETE INFORMATION
  
 ALL PERMIT APPLICATIONS SHOULD BE SUBMITTED TOGETHER TO
 EXPEDITE THE REVIEW PROCESS.TWO COPIES OF ALL PLANS,
 SURVEYS AND SPECIFICATIONS ARE REQUIRED.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]

Review Stop G GAS REVIEW
Rev No 2 Status P Date 2007-05-09 Cont ID  
Sent By mperson Date 2007-05-09 Time 14:12 Rev Time 0.33
Received By mperson Date 2007-05-09 Time 14:12 Sent To M
Notes
2007-05-09 14:15:09****************PROVISO****************
 A} PER FBC-2004 FUEL GAS, SECTION 404.13.3AN
 INSULATED COPPER TRACER WIRE SHALL BE INSTALLED
 ADJACENT TO UNDERGROUND NONMETALLIC GAS PIPING. THE
 TRACER WIRE SIZE SHALL NOT BE LESS THAN 18 AWG AND THE
 INSULATION TYPE SHALL BE SUITABLE FOR DIRECT BURIAL.
  
 B} PER FBC-2004 FUEL GAS SECTION 408.4 A SEDIMENT
 TRAP SHALL BE INSTALLED DOWNSTREAM OF THE EQUIPMENT
 SHUTOFF VALVE AS CLOSE TO THE INLET OF THE EQUIPMENT AS
 PRACTICAL.
  

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2007-04-11 Cont ID  
Sent By mperson Date 2007-04-11 Time 10:57 Rev Time 0.45
Received By mperson Date 2007-04-11 Time 10:57 Sent To B
Notes
2007-04-11 11:11:25DENIED
 REFERENCE:
 ** FBC-2004 FUEL GAS.
 ** THE CITY OF WEST PALM BEACH GAS AND GEN/RES PERMIT
 APPLICATION REQUIREMENTS.
 ** FBC-2004 CHAPTER 1, THE CITY OF
 WEST PALM BEACH AMENDMENTS.
  
 THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR
 GAS PLAN REVIEW TO MEET CODE COMPLIANCE:
  
 1. ONLY ONE COPY OF SURVEY WAS SUBMITTED, A MINIMUM OF
 TWO REQUIRED.
  
 2. PLEASE INDICATE ON THE SURVEY THE PROPOSED LOCATION
 OF THE GENERATOR AND THE DISTANCES TO ALL BUILDING
 OPENINGS. THIS INCLUDES DOORS, WINDOWS AND ATTIC
 VENTILATION OPENINGS. INDICATE THE DIMENSIONS OF THE
 PROPOSED GENERATOR FROM PROPERTY LINES AND DISTANCES
 FROM ADJACENT DWELLING STRUCTURES.
  
 3. PLEASE INDICATE THE ABOVE GROUND CORRESPONDING PIPE
 CUT LENGTHS AND PIPING MATERIAL ON THE RESUBMITTED
 DRAWINGS. THE ONLY LENGTH INDICATED IS 15' OF 1-1/4"
 PE. WHAT IS THE ABOVE GROUND PIPING MATERIAL AND CUT
 LENGTHS?
  
 END OF COMMENTS:
  
 REVIEW BY MIKE PERSON
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL [email protected]
 UNDER SUPERVISION OF K.STEVENS
 (561) 805-6721
  
  

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2007-05-08 Cont ID  
Sent By shill Date 2007-05-08 Time 16:10 Rev Time 0.00
Received By shill Date 2007-05-08 Time 16:10 Sent To E
Notes
2007-05-08 16:10:51TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2007-05-03 Cont ID  
Sent By adarroug Date 2007-05-03 Time 14:52 Rev Time 0.00
Received By adarroug Date 2007-05-03 Time 14:52 Sent To Z
Notes
2007-05-03 14:53:00TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-03-27 Cont ID  
Sent By spalmer Date 2007-03-27 Time 17:40 Rev Time 0.00
Received By spalmer Date 2007-03-27 Time 17:40 Sent To E
Notes
2007-03-27 17:40:29TO ELEC BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-04-20 Cont ID  
Sent By shill Date 2007-04-20 Time 17:55 Rev Time 0.00
Received By shill Date 2007-03-23 Time 10:24 Sent To  
Notes
2007-03-23 10:25:10TO "Z" BOX

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2007-05-09 Cont ID  
Sent By tgordon Date 2007-05-09 Time 14:55 Rev Time 0.25
Received By tgordon Date 2007-05-09 Time 14:55 Sent To B
Notes
2007-05-09 14:57:33*** PROVISO ***
 1) PER 2004 FBC, FUEL GAS - POWERED
 EQUIPMENT - PERMANENTLY INSTALLED
 EQUIPMENT POWERED BY INTERNAL COMBUSTION
 ENGINES SHALL BE INSTALLED IN ACCORDANCE
 WITH MANUFACTURER'S INSTALLATION
 INSTRUCTIONS AND NFPA 37.
  
 NFPA 37 INSTALLATION & USE OF STATIONARY COMBUSTION
 ENGINES & GAS TURBINES:
 4.1.4ENGINES (GENERATORS) LOCATED
 OUTDOORS SHALL BE MINIMUM OF 5 FT FROM
 OPENINGS IN WALLS & AT LEAST 5 FT FROM
 STRUCTURES HAVING COMBUSTIBLE WALLS.A
 MINIMUM CLEARANCE IS NOT REQUIRED WHEN
 (1) THE ADJACENT WALL HAS A MINIMUM FIRE RESISTANCE
 RATING OF 1 HOUR OR (2) THE WEATHERPROOF ENCLOSURE IS
 CONSTRUCTED OF NON-COMBUSTIBLE MATERIALS, AND IT HAS
 BEEN DEMONSTRATED THAT A FIRE WITHIN THE
 ENCLOSURE WILL NOT IGNITE COMBUSTIBLE
 MATERIALS OUTSIDE THE ENCLOSURE.
 INFORMATIVE: A.8.2.3.1EXHAUST SYSTEMS
 SHOULD NOT TERMINATE UNDER STRUCTURES OR
 WHERE THE EXHAUST MIGHT BE DRAWN INTO
 THE VENTILATION INTAKES.
  
 2004 FMC 804.3.5 #3, WHERE THE
 TERMINATION IS LOCATED BELOW AN ADJACENT
 ROOF STRUCTURE, THE TERMINATION POINT
 SHALL BE LOCATED AT LEAST 3 FT FROM THE
 ROOF STRUCTURE.
  
 PLEASE NOTE, WHILE ZONING ALLOWS
 MECHANICAL EQUIPMENT TO ENCROACH 4 FT
 INTO THE REQUIRED SETBACK, GENERATORS
 SHALL MAINTAIN THE REQUIRED ABOVE
 MENTIONED CLEARANCES TO THE ADJACENT
 PROPERTY STRUCTURES, I.E. FENCE,
 BUILDING, WINDOWS, DOORS, OR OPENINGS.
  
 FOLLOW MANUFACTURER'S RECOMMENDED
 CLEARANCES AROUND EQUIPMENT FOR
 SERVICING,AND PROVIDE MANUFACTURER'S
 INSTALLATION INSTRUCTIONS AT THE JOBSITE
 FOR THE FIELD INSPECTOR.
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2007-03-29 Cont ID  
Sent By tgordon Date 2007-03-29 Time 08:39 Rev Time 0.25
Received By tgordon Date 2007-03-29 Time 08:39 Sent To G
Notes
2007-03-29 08:40:53*** DENIED ***
 1) NEED TO SUBMIT TWO COPY'S OF THE SURVEY.
  
 2) NEED TO SHOW ON THE SURVEY THE PROPOSED LOCATION OF
 THE GENERATOR AND THE DISTANCES TO ALL BUILDINGS.
 BUILDING OPENINGS, AND PROPERTY LINES.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop Z ZONING
Rev No 2 Status P Date 2007-05-07 Cont ID  
Sent By adavila Date 2007-05-07 Time 14:39 Rev Time 0.00
Received By adavila Date 2007-05-04 Time 14:38 Sent To I
Notes
2007-05-07 14:39:17PER LINDA MIA FRANCO, SENIOR PLANNER.

Review Stop Z ZONING
Rev No 1 Status F Date 2007-03-26 Cont ID  
Sent By adavila Date 2007-03-26 Time 14:03 Rev Time 0.00
Received By adavila Date 2007-03-26 Time 14:03 Sent To I
Notes
2007-03-26 14:05:48PLANNING AND ZONING DEPARTMENT
  
 ***FAILED***
  
 1.ONLY ONE (1) COPY OF THE SURVEY WAS SUBMITTED WITH
 THE APPLICATION.AN ADDITIONAL COPY OF THE SURVEY
 SHALL BE PROVIDED.
  
 2.LOCATION WITH SETBACK DIMENSIONS FROM PROPERTY LINE
 SHALL BE PROVIDED ON BOTH COPIES OF SURVEY.PLEASE
 NOTE THAT PER SECTION 94-305(B)(4) OF THE ZONING AND
 LAND DEVELOPMENT REGULATIONS MECHANICAL EQUIPMENTS MAY
 NOT PROJECT MORE THAN FOUR (4) FEET INTO A SETBACK.
  
 COMMENTS/QUESTIONS CONTACT ANDREINA DAVILA Q. OR LINDA
 MIA FRANCO, SENIOR PLANNER, AT 822-1435.