Plan Review Stops For Permit 07030640 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2007-08-11 |
|
|
Cont ID |
|
Sent By |
amorse |
Date |
2007-08-11 |
Time |
09:34 |
Rev Time |
0.00 |
Received By |
amorse |
Date |
2007-08-11 |
Time |
09:34 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2007-06-23 |
|
|
Cont ID |
|
Sent By |
amorse |
Date |
2007-06-23 |
Time |
08:03 |
Rev Time |
0.00 |
Received By |
amorse |
Date |
2007-06-23 |
Time |
08:03 |
Sent To |
PC |
|
Notes |
2007-06-23 08:05:05 | | | | | DENIED | | | | THE FOLLOWING PREVIOUS REVIEW COMMENTS WERE NOT | | ADDRESSED | | | | 5)A DESIGN PROFESSIONAL THAT IS REGISTERED TO | | PRACTICE UNDER CHAPTER 481 OR 471 OF | | THE FLORIDA STATUTES SHALL AFFIX THEIR OFFICIAL SEAL, | | SIGNATURE AND DATE TO SAID DRAWINGS AND SPECIFICATIONS | | PER 106.1 FBC 2004 | | *****PLEASE SEE COVER SHEET AND D/1 THE SEALS ARE NOT | | DATED****** | | | | 12)WINDOW #4 FROM SCHEDULE 48"X101" EXCEEDS THE MAX | | SQUARE FOOTAGE STATED IN THE PGT PRODUCT APPROVAL NOA | | FOR FIXED WINDOWS MAX. SQ.FT. = 32, WINDOW IS 33.66667 | | SQ. FT.*****THIS EXCEEDS THE PGT TESTING FOR THIS | | PRODUCT, EITHER THE WINDOW SIZE MUST BE REDUCED TO MEET | | THE PRODUCT APPROVAL OR THE PRODUCT INFORMATION FOR THE | | LARGER SIZE CAN BE SUBMITTED FOR A LOCAL PRODUCT | | APPROVAL***** | | | | 1)PROVIDE PRODUCT APPROVAL FOR NEW 12'-0" SLIDING | | GLASS DOOR THAT WAS ADDED TO THE GREAT ROOM | | | | BLDG PLAN REVIEW | | ADRIAN MORSE | | 561-805-6716 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2007-04-19 |
|
|
Cont ID |
|
Sent By |
amorse |
Date |
2007-04-19 |
Time |
16:26 |
Rev Time |
0.00 |
Received By |
amorse |
Date |
2007-04-19 |
Time |
16:26 |
Sent To |
PC |
|
Notes |
2007-04-19 16:47:12 | | | | | DENIED | | | | | | 1)DRAWINGS TO COMPLY WITH THE LATEST CODE, PLACE NOTE | | ON PLANS THAT THEY CONFORM TO THE 2004 FLORIDA BUILDING | | CODE WITH 2006 REVISIONS | | | | 2)PROVIDE THE WIND DESIGN DATA THAT APPLIES TO | | BUILDING PER 1603.1.4 FBC | | | | 3)PROVIDE TYPE OF CONSTRUCTION AND OCCUPANCY GROUP ON | | PLANS | | | | 4)THE CLAIMED VALUATION ON THE PERMIT APPLICATION IS | | LOW. FOR PERMITTING PURPOSES, VALUATION OF BUILDINGS | | AND SYSTEMS SHALL BE THE TOTAL REPLACEMENT COST | | EXCLUDING LAND VALUE. OUR VALUATION REFERENCE IS ICC | | (BVD), MARSHALL-SWIFT AND MEANS COST ANALYSIS SERVICES | | PER 108.3 FBC*.VALUE ADJUSTED TO $359,745 WHICH | | INCREASES THE PERMIT FEE. BALANCE DUE IS $123.14. | | | | 5)A DESIGN PROFESSIONAL THAT IS REGISTERED TO | | PRACTICE UNDER CHAPTER 481 OR 471 OF | | THE FLORIDA STATUTES SHALL AFFIX THEIR OFFICIAL SEAL, | | SIGNATURE AND DATE TO SAID DRAWINGS AND SPECIFICATIONS | | PER 106.1 FBC 2004 | | | | 6)PLAN, ELEVATION AND DOOR, WINDOW SCHEDULE DO NOT | | MATCH.LIVINGROOM ELEVATION HAS 1 WINDOW SCHEDULE HAS | | 2 AND NO MULLION STATED FOR LIVINGROOM OR MASTER | | SUITE. | | | | 7)BUILDING ELEVATION TO INCLUDE MEAN ROOF HEIGHT AND | | ROOF PITCH. THE PITCH ON 1/D1 MAY BE CORRECT BUT DETAIL | | IS TYPICAL DETAIL SO IN MAY NOT BE FOR THIS PARTICULAR | | BUILDING. | | | | 8)SUBMIT ENGINEERED TRUSS DRAWINGS THAT | | COMPLY WITH R802.10.1 FBC WITH PERMIT APPLICATION OR | | BEFORE INSTALLATION THAT HAVE BEEN REVIEWED AND | | APPROVED BY THE DESIGNER OF RECORD | | | | 9)NOA FOR PRE-CAST LINTELS IS INCORRECT SUBMITTED NOA | | IS FOR 4, 6 AND 12" WIDE BLOCK APPLICATIONS PROVIDE | | MIAMI-DADE NOA # 03-0605.05 FOR 8" LINTELS | | | | 10)GLASS BLOCK MEETS THE DESIGN PRESSURES REQUIRED | | BUT IS ONLY SMALL MISSILE IMPACT RATED. PER 1609.1.4 | | FBC GLAZING WITHIN THE FIRST 30 FEET FROM GRADE ARE | | REQUIRED TO MEET LARGE MISSILE IMPACT TEST REQUIREMENTS | | THEREFORE THESE OPENINGS WILL REQUIRE AN IMPACT | | PROTECTION SYSTEM. | | | | 11)PROVIDE LINTEL SCHEDULE THAT SHOW LINTELS MEET THE | | REQUIREMENTS OF 2104.5 FBC FOR MIN END BEARING | | | | 12)WINDOW #4 FROM SCHEDULE 48"X101" EXCEEDS THE MAX | | SQUARE FOOTAGE STATED IN THE PGT PRODUCT APPROVAL NOA | | FOR FIXED WINDOWS MAX. SQ.FT. = 32, WINDOW IS 33.66667 | | SQ. FT. | | | | 13)PRODUCT APPROVAL FOR HANSON ROOF TILE REQUIRES | | ANSWERS TO NOTE #7 IN ORDER TO CALCULATE MOMENT OF | | UPLIFT FOR TILE. | | | | | | NOTE: FBC = FLORIDA BUILDING CODE 2004 | | FBC* = WEST PALM BEACH ADMINISTRATIVE | | AMENDMENTS TO FBC | | FAC = FLORIDA ADMINISTRATIVE CODE | | FS = FLORIDA STATUTES | | | | | | | | BLDG PLAN REVIEW | | ADRIAN MORSE | | 561-805-6716 | | | | | | | | | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
P |
Date |
2008-01-07 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2008-01-07 |
Time |
09:06 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2008-01-07 |
Time |
09:06 |
Sent To |
PC |
|
Notes |
2008-01-07 09:07:05 | LV PERMIT FOR SPKRS REQUIRED AND SEPARATE PERMIT. | | MAY REFERENCE THESE PLANS FOR TURN AROUND PERMIT. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2007-07-25 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2007-07-25 |
Time |
08:47 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2007-07-25 |
Time |
08:06 |
Sent To |
P |
|
Notes |
2007-07-25 08:48:25 | PLANS REDLINED. 2ND TIME. | | NEW SHEETS SUBMITTED HOWEVER NO CORRECTIONS WERE MADE | | TO THE ITEMS AS NOTED BELOW FROM PREVIOUS REVIEW. | | | | | | * PLEASE SEE PREVIOUS REQUESTED CODES AND NOTES WERE | | PLACED ON D-1 AND NOT ON ELECTRICAL SHEETS. THIS | | INLCUDES THE NOTES FOR RECESSED LIGHTING REQUIREMENTS | | AND CORRECT ADOPTED CODES FOR DESIGN.( PLEASE PLACE ON | | ELECTRICAL SHEETS). | | * NOTES ON ELECTRICAL SHEETS IN LEGEND STILL INDICATE | | THE 2002 NEC. | | * PLEASE SEE GFI PROTECTION IS REQUIRED FOR "ALL" | | RECEPTS WITHIN 6FT OF LAUNDRY ROOM SINK WHICH ARE 125V | | 15 OR 20 AMP. (INCLUDING DEDICATED USE RECEPTS, THIS | | WAS CHANGED IN THE 2005 NEC ) | | | | ** PLEASE CORRECT THE ABOVE ALONG WHEN ANY OTHER | | REVISIONS ARE MADE TO PLANS. | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2007-06-03 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2007-06-03 |
Time |
10:48 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2007-06-03 |
Time |
10:11 |
Sent To |
P |
|
Notes |
2007-06-03 10:51:37 | PLANS REDLINED. | | | | | | * PLEASE SEE PREVIOUS REQUESTED CODES AND NOTES WERE | | PLACED ON D-1 AND NOT ON ELECTRICAL SHEETS. THIS | | INLCUDES THE NOTES FOR RECESSED LIGHTING REQUIREMENTS | | AND CORRECT ADOPTED CODES FOR DESIGN.( PLEASE PLACE ON | | ELECTRICAL SHEETS). | | * NOTES ON ELECTRICAL SHEETS IN LEGEND STILL INDICATE | | THE 2002 NEC. | | * PLEASE SEE GFI PROTECTION IS REQUIRED FOR "ALL" | | RECEPTS WITHIN 6FT OF LAUNDRY ROOM SINK WHICH ARE 125V | | 15 OR 20 AMP. (INCLUDING DEDICATED USE RECEPTS, THIS | | WAS CHANGED IN THE 2005 NEC ) | | | | ** PLEASE CORRECT THE ABOVE ALONG WHEN ANY OTHER | | REVISIONS ARE MADE TO PLANS. | | | | | | SOME SHEETS STILL NOT DATED BY THE ARCHITECT.( | | ELECTRICAL SHEETS OK). |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2007-03-20 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2007-03-20 |
Time |
20:04 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2007-03-20 |
Time |
19:45 |
Sent To |
Z |
|
Notes |
2007-03-20 20:04:51 | ROUTED BACK TO ZONING. | 2007-03-20 20:04:28 | *** UNSAT *** | | | | 6623 SPARROW HAWK DR. | | | | | | 1) NOTE: PLEASE BE SURE ALL PLANS REFLECT THE LATEST | | ADOPTED CODES PER THE STATE OF FLORIDA. PLEASE SEE THE | | FOLLOWING WHICH ARE CURRENTLY ADOPTED AS OF DECEMBER | | 8TH, 2006. | | 2004 FBC W/ 2006 REVISION. (THIS WILL AFFECT PLANS | | SUBMITTED). | | 2005 NFPA-70 (NEC). | | 2002 NFPA-72 | | 2003 NFPA-101 | | ** THESE CODES ARE REQUIRED AT A MINIMUM FOR THIS TRADE | | REVIEWER; OTHERS MAY BE REQUIRED PER OTHER TRADES OR | | REVIEWER(S). | | PLEASE SEE THERE ARE MANY AREAS ON THE PLANS WHICH | | REFERENCE OLDER CODES FROM PREVIOUS CODES, THESE SHOULD | | BE REVISED ACCORDINGLY. | | | | 2) NOTE: PLEASE SEE 2004 FBC W/2006 FOR NOTE REQUIRED | | FOR TYPE OF RECESSED LIGHTING FIXTURES PER | | 13-606.1.ABC.1.2.4 | | | | 3) NOTE: PLEASE SEE 250.53G AS THE MINIMUM SIZE OF THE | | GROUND ROD SHALL BE 8FT MINIMUM. | | | | 4) NOTE: PLEASE SEE THE COMPRESSOR FOR THE A/C CU IS | | BEING SHOWN WITH A LOAD OF 9.8KW; PLEASE VERIFY THIS AS | | THIS LOAD EXCEED THAT OF THE RATING OF THE CIRCUIT | | BREAKER. | | THIS WAS REDLINED ON PREVIOUS PLANS ON MANY OCCASIONS | | BUT TO DATE NO CHANGES HAVE BEEN MADE. | | | | 5) NOTE: PLEASE SEE THAT THE USE OF SD FOR SMOKE | | DETECTORS ON PLANS FOR RESIDENTIAL HOMES IS NOT | | ACCEPTABLE WHEN THESE DEVICES ANY ACTUALLY FALL UNDER | | THE DEFINITIONS OF SMOKE ALARMS WHICH WOULD BE SHOWN AS | | SA/SMOKE ALARMS. | | THE GENERAL USE OF THE SD FOR SMOKE DETECTORS WAS | | ALWAYS ACCEPTEDHOWEVER BASED ON THE DEFINITIONS AS | | STATED IN NFPA-72 A SD/ SMOKE DETECTOR IS ONLY A DEVICE | | WHICH WILL DETECT AND WILL NOT SOUND AN AUDIBLE ALARM. | | THIS WOULD BE DONE BY HORN/SIREN TYPE DEVICES. PLEASE | | SEE THE DEFINITIONS OF SA/SMOKE ALARMS; THESE ARE | | DEVICES WHICH ARE 120V (AS SHOWN) AND WOULD DETECT AND | | SOUND AN ALARM. THIS IS SOMETHING THAT IS NOW BEING | | COMMENTED ON OTHER REVIEWS FOR OTHER NEW HOMES. | | ** PLEASE SEE THAT SMOKE ALARMS ARE STATED IN THE FBC | | RESIDENTIAL CODE/ FBC AND IN NFPA-72. | | IF THERE ARE ANY QUESTIONS ON THIS COMMENT PLEASE DO | | NOT HESITATE IN CONTACTING THIS OFFICE. | | | | 6) NOTE: PLEASE SEE THAT UNDER THE NEW 2005 NEC | | 210.8A7, ALL 15/20 AMP 125V RECEPTACLES WITHIN 6FT OF | | SINKS SHALL CONTAIN GFI PROTECTION EVEN LAUNDRY ROOMS | | AND WASHING MACHINES LOCATED WITHIN 6FT EVEN IF THEY | | ARE ON A DEDICATED/SINGLE RECEPTACLE. | | | | ** IMPORTANT** | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | PICKED UP FOR CORRECTIONS, PLEASE BE | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | SHEETS AND ONLY INSERT NEW REVISED | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | AND STAMPING. DO NOT LEAVE ANY | | OLD/VOIDED SHEETS IN SETS. | | PLEASE KNOW ONLY ONE SET OF THE | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | FOR REFERENCE. | | THIS WILL HELP IN THE REVIEW PROCESS AND | | AVOID ANY DELAYS. | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | REVIEWER. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW II | | CONSTRUCTION SERVICES DEPT. | | CITY OF WEST PALM BEACH | | 561-805-6717 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
7 |
Status |
N |
Date |
2008-04-02 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-04-02 |
Time |
14:56 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-04-02 |
Time |
14:56 |
Sent To |
Z |
|
Notes |
2008-04-02 14:56:32 | TO "Z" BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2008-01-04 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-01-04 |
Time |
11:48 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-01-04 |
Time |
11:48 |
Sent To |
E |
|
Notes |
2008-01-04 11:49:14 | TO "DPALMER" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2007-08-24 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-08-24 |
Time |
16:37 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-08-24 |
Time |
16:37 |
Sent To |
P |
|
Notes |
2007-08-24 16:38:54 | TO "P" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2007-07-23 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-07-23 |
Time |
15:22 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-07-23 |
Time |
15:22 |
Sent To |
E |
|
Notes |
2007-07-23 15:23:12 | TO "DPALMER" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2007-05-24 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-05-24 |
Time |
13:31 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-05-24 |
Time |
13:31 |
Sent To |
E |
|
Notes |
2007-05-24 13:32:17 | TO "E" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2007-03-24 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-03-24 |
Time |
12:08 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-03-24 |
Time |
12:08 |
Sent To |
M |
|
Notes |
2007-03-24 12:08:52 | TO "SFR" "M" |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2007-04-19 |
Time |
|
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-03-20 |
Time |
11:11 |
Sent To |
|
|
Notes |
2007-03-20 11:12:08 | TO "SFR" "Z" |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2007-03-27 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2007-03-27 |
Time |
12:04 |
Rev Time |
0.30 |
Received By |
tgordon |
Date |
2007-03-27 |
Time |
12:04 |
Sent To |
P |
|
Notes |
2007-03-27 12:06:33 | *** PROVISO *** | | 1) DUCTS IN THE GARAGE AND DUCTS | | PENETRATING THE WALLS OR CEILINGS | | SEPARATING THE DWELLING FROM THE GARAGE | | SHALL BE CONSTRUCTED OF A MINIMUM NO. 26 | | GAGE SHEET STEEL OR OTHER APPROVED | | MATERIAL AND SHALL HAVE NO OPENINGS INTO | | THE GARAGE. PER 2004 FBC/R 309.1.1 . | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
P |
Date |
2007-09-12 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2007-09-12 |
Time |
09:44 |
Rev Time |
0.00 |
Received By |
mperson |
Date |
2007-09-12 |
Time |
09:44 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
F |
Date |
2007-08-07 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2007-08-07 |
Time |
09:49 |
Rev Time |
0.45 |
Received By |
mperson |
Date |
2007-08-07 |
Time |
09:49 |
Sent To |
B |
|
Notes |
2007-08-07 10:17:18 | DENIED 3RD TIME | | REFERENCE: | | ** FBC-2004 PLUMBING. | | ** FBC-2004 CHAPTER 1, THE CITY OF | | WEST PALM BEACH AMENDMENTS. | | ** FLORIDA ADMINISTRATIVE CODE. | | ** FLORIDA STATUTES. | | | | 1. SHEET PE-1: THE RESUBMITTED SANITARY ISOMETRIC | | RISER DIAGRAM DOES NOT REFLECT THE FLOOR PLAN OF THE | | UNDERGROUND SANITARY PLUMBING BEING INDICATED ON SHEET | | A-1.0. PLEASE REFERENCE THE SANITARY ISOMETRIC RISER | | DIAGRAM THAT REFLECTS THE FLOOR PLAN ATTACHED TO THESE | | PLUMBING COMMENTS FOR THE NEXT RESUBMITTAL. | | | | PER FBC-2004 CHAPTER 1 SECTION 106.1.1 INFORMATION ON | | CONSTRUCTION | | DOCUMENTS. CONSTRUCTION DOCUMENTS SHALL | | BE OF SUFFICIENT CLARITY TO INDICATE THE | | LOCATION, NATURE AND EXTENT OF THE WORK | | PROPOSED AND SHOW IN DETAIL THAT IT WILL | | CONFORM TO THE PROVISIONS OF THIS CODE | | AND RELAVENT LAWS, ORDINANCES, RULES AND REGULATIONS, | | AS DETERMINED BY THE | | BUILDING OFFICIAL. | | | | 2. PER FBC-2004 CHAPTER 1, SECTION 106.3.5.4 | | RESIDENTIAL (ONE AND TWO-FAMILY) PLEASE SUBMIT A | | PLUMBING SANITARY ISOMETRIC RISER DIAGRAM INDICATING | | ALL WASTE, VENTS, TRAPS AND SIZES WITH CLEANOUT | | LOCATIONS. | | NOTE: NOT ALL PIPE SIZES AND TRAPS ARE INDICATED ON THE | | RESUBMITTED SANITARY ISOMETRIC. | | | | ********IMPORTANT INFORMATION******** | | IN ORDER TO EXPIDITE PLAN REVIEW: WHEN RESUBMITTING, | | PLEASE REPLACE ONLY SHEETS | | WHICH HAVE CHANGED, PLEASE INCLUDE A | | TRANSMITTAL LETTER INDICATING HOW EACH | | ITEM WAS ADDRESSED AND PROVIDE ONE COPY | | OF ALL OLD/VOIDED SHEETS FOR REFERENCE | | ONLY. | | NOTE: ONLY ONE CORRECTED DRAWING | | IN RED INK FOR REFERENCE FOR | | RESUBMITTAL. | | | | | | END OF COMMENTS: | | | | REVIEW BY MIKE PERSON | | PLUMBING PLANS EXAMINER | | (561) 805-6730 | | FAX (561) 805-6731 | | E-MAIL= [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2007-06-18 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2007-06-18 |
Time |
08:39 |
Rev Time |
0.00 |
Received By |
mperson |
Date |
2007-06-18 |
Time |
09:44 |
Sent To |
B |
|
Notes |
2007-06-18 09:21:04 | DENIED 2ND TIME | | REFERENCE: | | ** FBC-2004 PLUMBING. | | ** FBC-2004 CHAPTER 1, THE CITY OF | | WEST PALM BEACH AMENDMENTS. | | ** FLORIDA ADMINISTRATIVE CODE. | | ** FLORIDA STATUTES. | | | | ** PLEASE SEE SOME NOTES FROM PREVIOUS REVIEW ARE STILL | | IN NEED OF ADDRESSING ALONG WITH SOME NEW COMMENTS, | | SOME BASED ON PLANS NOW SUBMITTED, NEW DOCUMENTS BEING | | REVIEWED FOR THE FIRST TIME AND SOME NEW COMMENTS NOT | | MADE ON PREVIOUS REVIEWS. | | | | ** PLEASE SEE THE NOTES BELOW ARE TAKEN DIRECTLY FROM | | PREVIOUS REVIEW WITH A NO, OK OR A NO/OK. | | THESE WILL BE FOR THE EXACT NUMERICAL NOTATION OF THE | | PREVIOUS REVIEW NOTES. | | | | A NO IS IF THE COMMENT WAS NOT FULLY ADDRESSED AND/OR | | FURTHER EXPLANATION OR CHANGES IN PLANS OR DOCUMENTS | | ARE STILL NEEDED. THIS REVIEWER WILL TRY TO BETTER | | EXPLAIN NOTE ABOVE PREVIOUS REVIEW COMMENT. | | | | AN OK WILL BE LABELED AS SUCH ON THE SAME NUMERICAL | | COMMENT AND WILL HAVE OLD NOTE REMOVED FROM COMMENTS. | | | | A NO/OK MEANS PART OF THE COMMENT MAY HAVE BEEN | | ADDRESSED, HOWEVER NOT ALL OF THE PREVIOUS REVIEW | | COMMENT MAY HAVE BEEN FULLY ADDRESSED. | | | | ** PLEASE SEE ANY NEW NOTES WILL BE ADDED TO THE END OF | | THE PREVIOUS REVIEW COMMENTS AND NOTED AS SUCH. | | | | 1. **OK** | | | | 2. SHEET A-1.0 SANITARY RISER DIAGRAM: PLEASE SEE THAT | | THERE IS STILL AN ISSUE WITH D}. PLEASE CORREC THIS ON | | THE RESUBMITTAL. | | A} **OK** | | B} **OK** | | C} **OK** | | D} **NO** A VENT IS BEING INDICATED ON THE FLOOR | | PLAN PLUMBING ON THIS SHEET, BUT IS MISSING ON THE | | RISER DIAGRAM. A VENT IS STILL REQUIRED AND NEEDS TO BE | | INDICATED FOR BATH #3 SHOWER. PER FBC-2004 PLUMBING, | | SECTION 901.2.1. | | | | THE FOLLOWING IS A NEW ITEM: | | | | 3. SHEET A-1.0 LAUNDRY: THE SANITARY RISER DIAGRAM | | DOES NOT RELECT THE FLOOR PLAN IN THE LAUNDRY FOR THE | | WASHING MACHINE. THE RESUBMITTED THREE INCH (3") BRANCH | | IS BEING INDICATED ON THE WRONG SIDE OF THE LAUNDRY | | TRAY AND THE FLOW IS WRONG. PLEASE CORRECT THIS ON THE | | RESUBMITTAL. | | 106.1.1 INFORMATION ON CONSTRUCTION | | DOCUMENTS. CONSTRUCTION DOCUMENTS SHALL | | BE OF SUFFICIENT CLARITY TO INDICATE THE | | LOCATION, NATURE AND EXTENT OF THE WORK | | PROPOSED AND SHOW IN DETAIL THAT IT WILL | | CONFORM TO THE PROVISIONS OF THIS CODE | | AND RELAVENT LAWS, ORDINANCES, RULES AND REGULATIONS, | | AS DETERMINED BY THE | | BUILDING OFFICIAL. | | | | ********IMPORTANT INFORMATION******** | | IN ORDER TO EXPIDITE PLAN REVIEW: WHEN RESUBMITTING, | | PLEASE REPLACE ONLY SHEETS | | WHICH HAVE CHANGED, PLEASE INCLUDE A | | TRANSMITTAL LETTER INDICATING HOW EACH | | ITEM WAS ADDRESSED AND PROVIDE ONE COPY | | OF ALL OLD/VOIDED SHEETS FOR REFERENCE | | ONLY. | | NOTE: ONLY ONE CORRECTED DRAWING | | IN RED INK FOR REFERENCE FOR | | RESUBMITTAL. | | | | END OF COMMENTS: | | | | REVIEW BY MIKE PERSON | | PLUMBING PLANS EXAMINER | | (561) 805-6730 | | FAX (561) 805-6731 | | E-MAIL [email protected] | | UNDER SUPERVISION OF K.STEVENS | | (561) 805-6721 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2007-04-03 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2007-06-03 |
Time |
11:34 |
Rev Time |
0.55 |
Received By |
mperson |
Date |
2007-04-03 |
Time |
09:10 |
Sent To |
B |
|
Notes |
2007-04-03 09:35:06 | DENIED | | REFERENCE: | | ** FBC-2004 PLUMBING. | | ** FBC-2004 CHAPTER 1, THE CITY OF | | WEST PALM BEACH AMENDMENTS. | | ** FLORIDA ADMINISTRATIVE CODE. | | ** FLORIDA STATUTES. | | | | THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR | | PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE: | | | | 1. FAC-61G1-16.004 TITLE BLOCK: | | A TITLE BLOCK MUST APPEAR ON ALL | | ARCHITECTURAL OR INTERIOR DESIGN | | DRAWINGS AND SPECIFICATION | | IDENTIFICATION SHEETS. THE TITLE BLOCK | | MUST, AT A MINIMUM, CONTAIN THE | | FOLLOWING INFORMATION: | | (1) FIRM NAME, ADDRESS, AND TELEPHONE | | NUMBER. | | (2) FIRM LICENSE NUMBER. | | (3) NAME OR IDENTIFICATION OF PROJECT. | | (4) DATE PREPARED. | | (5) A SPACE FOR THE SIGNATURE AND DATED | | SEAL. | | (6) A SPACE FOR THE PRINTED NAME OF THE | | PERSON SEALING THE DOCUMENT. | | NOTE: NUMBER (6)A SPACE FOR THE PRINTED NAME OF THE | | PERSON SEALING THE DOCUMENT IS MISSING FROM SHEETS. | | PLEASE CORRECT ON THE RESUBMITTAL. | | | | 2. SHEET A-1.O ISOMETRIC SANITARY RISER DIAGRAM PLEASE | | CORRECT THE FOLLOWING ON THE RESUBMITTAL: | | | | A} THE SHOWER IN BATH #2 IS INCORRECTLY INDICATED AS A | | TUB WASTE AND OVERFLOW. | | | | B} WASHING MACHINE BRANCH DRAIN AND DRAINAGE STACK NEED | | TO BE 3 INCH PER FBC-2004 PLUMBING, SECTION 406.3. | | | | C} CLEANOUT FOR WASHING MACHINE IS INCORRECTLY | | INDICATED AT THE BASE OF THE DRAINAGE STACK AND DOES | | NOT REFLECT THE NOTES AT BEING 4' A.F.F. | | | | D} VENT REQUIRED FOR BATH #3 SHOWER PER FBC-2004 | | PLUMBING, SECTION 901.2.1. | | | | ********IMPORTANT INFORMATION******** | | IN ORDER TO EXPIDITE PLAN REVIEW: WHEN RESUBMITTING, | | PLEASE REPLACE ONLY SHEETS | | WHICH HAVE CHANGED, PLEASE INCLUDE A | | TRANSMITTAL LETTER INDICATING HOW EACH | | ITEM WAS ADDRESSED AND PROVIDE ONE COPY | | OF ALL OLD/VOIDED SHEETS FOR REFERENCE | | ONLY. NOTE: ONLY ONE CORRECTED DRAWING | | IN RED INK FOR REFERENCE FOR | | RESUBMITTAL. | | | | END OF COMMENTS: | | | | REVIEW BY MIKE PERSON | | (561) 805-6730 | | FAX (561) 805-6731 | | E-MAIL [email protected] | | UNDER SUPERVISION OF K.STEVENS | | (561) 805-6721 | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2008-04-03 |
|
|
Cont ID |
|
Sent By |
choops |
Date |
2008-04-03 |
Time |
10:53 |
Rev Time |
0.00 |
Received By |
choops |
Date |
2008-04-03 |
Time |
10:53 |
Sent To |
PC |
|
Notes |
2008-04-03 10:53:57 | ***APPROVED - LANDSCAPE PLAN SUBMITTAL*** |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2007-03-22 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2007-03-22 |
Time |
14:28 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2007-03-22 |
Time |
14:28 |
Sent To |
I |
|
Notes |
2007-03-22 14:28:56 | PASSED, PER A. JONES-VANN. |
|
|