Plan Review Details - Permit 07030640
Plan Review Stops For Permit 07030640
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2007-08-11 Cont ID  
Sent By amorse Date 2007-08-11 Time 09:34 Rev Time 0.00
Received By amorse Date 2007-08-11 Time 09:34 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2007-06-23 Cont ID  
Sent By amorse Date 2007-06-23 Time 08:03 Rev Time 0.00
Received By amorse Date 2007-06-23 Time 08:03 Sent To PC
Notes
2007-06-23 08:05:05 
  
 DENIED
  
 THE FOLLOWING PREVIOUS REVIEW COMMENTS WERE NOT
 ADDRESSED
  
 5)A DESIGN PROFESSIONAL THAT IS REGISTERED TO
 PRACTICE UNDER CHAPTER 481 OR 471 OF
 THE FLORIDA STATUTES SHALL AFFIX THEIR OFFICIAL SEAL,
 SIGNATURE AND DATE TO SAID DRAWINGS AND SPECIFICATIONS
 PER 106.1 FBC 2004
 *****PLEASE SEE COVER SHEET AND D/1 THE SEALS ARE NOT
 DATED******
  
 12)WINDOW #4 FROM SCHEDULE 48"X101" EXCEEDS THE MAX
 SQUARE FOOTAGE STATED IN THE PGT PRODUCT APPROVAL NOA
 FOR FIXED WINDOWS MAX. SQ.FT. = 32, WINDOW IS 33.66667
 SQ. FT.*****THIS EXCEEDS THE PGT TESTING FOR THIS
 PRODUCT, EITHER THE WINDOW SIZE MUST BE REDUCED TO MEET
 THE PRODUCT APPROVAL OR THE PRODUCT INFORMATION FOR THE
 LARGER SIZE CAN BE SUBMITTED FOR A LOCAL PRODUCT
 APPROVAL*****
  
 1)PROVIDE PRODUCT APPROVAL FOR NEW 12'-0" SLIDING
 GLASS DOOR THAT WAS ADDED TO THE GREAT ROOM
  
 BLDG PLAN REVIEW
 ADRIAN MORSE
 561-805-6716

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-04-19 Cont ID  
Sent By amorse Date 2007-04-19 Time 16:26 Rev Time 0.00
Received By amorse Date 2007-04-19 Time 16:26 Sent To PC
Notes
2007-04-19 16:47:12 
  
 DENIED
  
  
 1)DRAWINGS TO COMPLY WITH THE LATEST CODE, PLACE NOTE
 ON PLANS THAT THEY CONFORM TO THE 2004 FLORIDA BUILDING
 CODE WITH 2006 REVISIONS
  
 2)PROVIDE THE WIND DESIGN DATA THAT APPLIES TO
 BUILDING PER 1603.1.4 FBC
  
 3)PROVIDE TYPE OF CONSTRUCTION AND OCCUPANCY GROUP ON
 PLANS
  
 4)THE CLAIMED VALUATION ON THE PERMIT APPLICATION IS
 LOW. FOR PERMITTING PURPOSES, VALUATION OF BUILDINGS
 AND SYSTEMS SHALL BE THE TOTAL REPLACEMENT COST
 EXCLUDING LAND VALUE. OUR VALUATION REFERENCE IS ICC
 (BVD), MARSHALL-SWIFT AND MEANS COST ANALYSIS SERVICES
 PER 108.3 FBC*.VALUE ADJUSTED TO $359,745 WHICH
 INCREASES THE PERMIT FEE. BALANCE DUE IS $123.14.
  
 5)A DESIGN PROFESSIONAL THAT IS REGISTERED TO
 PRACTICE UNDER CHAPTER 481 OR 471 OF
 THE FLORIDA STATUTES SHALL AFFIX THEIR OFFICIAL SEAL,
 SIGNATURE AND DATE TO SAID DRAWINGS AND SPECIFICATIONS
 PER 106.1 FBC 2004
  
 6)PLAN, ELEVATION AND DOOR, WINDOW SCHEDULE DO NOT
 MATCH.LIVINGROOM ELEVATION HAS 1 WINDOW SCHEDULE HAS
 2 AND NO MULLION STATED FOR LIVINGROOM OR MASTER
 SUITE.
  
 7)BUILDING ELEVATION TO INCLUDE MEAN ROOF HEIGHT AND
 ROOF PITCH. THE PITCH ON 1/D1 MAY BE CORRECT BUT DETAIL
 IS TYPICAL DETAIL SO IN MAY NOT BE FOR THIS PARTICULAR
 BUILDING.
  
 8)SUBMIT ENGINEERED TRUSS DRAWINGS THAT
 COMPLY WITH R802.10.1 FBC WITH PERMIT APPLICATION OR
 BEFORE INSTALLATION THAT HAVE BEEN REVIEWED AND
 APPROVED BY THE DESIGNER OF RECORD
  
 9)NOA FOR PRE-CAST LINTELS IS INCORRECT SUBMITTED NOA
 IS FOR 4, 6 AND 12" WIDE BLOCK APPLICATIONS PROVIDE
 MIAMI-DADE NOA # 03-0605.05 FOR 8" LINTELS
  
 10)GLASS BLOCK MEETS THE DESIGN PRESSURES REQUIRED
 BUT IS ONLY SMALL MISSILE IMPACT RATED. PER 1609.1.4
 FBC GLAZING WITHIN THE FIRST 30 FEET FROM GRADE ARE
 REQUIRED TO MEET LARGE MISSILE IMPACT TEST REQUIREMENTS
 THEREFORE THESE OPENINGS WILL REQUIRE AN IMPACT
 PROTECTION SYSTEM.
  
 11)PROVIDE LINTEL SCHEDULE THAT SHOW LINTELS MEET THE
 REQUIREMENTS OF 2104.5 FBC FOR MIN END BEARING
  
 12)WINDOW #4 FROM SCHEDULE 48"X101" EXCEEDS THE MAX
 SQUARE FOOTAGE STATED IN THE PGT PRODUCT APPROVAL NOA
 FOR FIXED WINDOWS MAX. SQ.FT. = 32, WINDOW IS 33.66667
 SQ. FT.
  
 13)PRODUCT APPROVAL FOR HANSON ROOF TILE REQUIRES
 ANSWERS TO NOTE #7 IN ORDER TO CALCULATE MOMENT OF
 UPLIFT FOR TILE.
  
  
 NOTE: FBC = FLORIDA BUILDING CODE 2004
 FBC* = WEST PALM BEACH ADMINISTRATIVE
 AMENDMENTS TO FBC
 FAC = FLORIDA ADMINISTRATIVE CODE
 FS = FLORIDA STATUTES
  
  
  
 BLDG PLAN REVIEW
 ADRIAN MORSE
 561-805-6716
  
  
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2008-01-07 Cont ID  
Sent By dpalmer Date 2008-01-07 Time 09:06 Rev Time 0.00
Received By dpalmer Date 2008-01-07 Time 09:06 Sent To PC
Notes
2008-01-07 09:07:05LV PERMIT FOR SPKRS REQUIRED AND SEPARATE PERMIT.
 MAY REFERENCE THESE PLANS FOR TURN AROUND PERMIT.

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2007-07-25 Cont ID  
Sent By dpalmer Date 2007-07-25 Time 08:47 Rev Time 0.00
Received By dpalmer Date 2007-07-25 Time 08:06 Sent To P
Notes
2007-07-25 08:48:25PLANS REDLINED. 2ND TIME.
 NEW SHEETS SUBMITTED HOWEVER NO CORRECTIONS WERE MADE
 TO THE ITEMS AS NOTED BELOW FROM PREVIOUS REVIEW.
  
  
 * PLEASE SEE PREVIOUS REQUESTED CODES AND NOTES WERE
 PLACED ON D-1 AND NOT ON ELECTRICAL SHEETS. THIS
 INLCUDES THE NOTES FOR RECESSED LIGHTING REQUIREMENTS
 AND CORRECT ADOPTED CODES FOR DESIGN.( PLEASE PLACE ON
 ELECTRICAL SHEETS).
 * NOTES ON ELECTRICAL SHEETS IN LEGEND STILL INDICATE
 THE 2002 NEC.
 * PLEASE SEE GFI PROTECTION IS REQUIRED FOR "ALL"
 RECEPTS WITHIN 6FT OF LAUNDRY ROOM SINK WHICH ARE 125V
 15 OR 20 AMP. (INCLUDING DEDICATED USE RECEPTS, THIS
 WAS CHANGED IN THE 2005 NEC )
  
 ** PLEASE CORRECT THE ABOVE ALONG WHEN ANY OTHER
 REVISIONS ARE MADE TO PLANS.
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2007-06-03 Cont ID  
Sent By dpalmer Date 2007-06-03 Time 10:48 Rev Time 0.00
Received By dpalmer Date 2007-06-03 Time 10:11 Sent To P
Notes
2007-06-03 10:51:37PLANS REDLINED.
  
  
 * PLEASE SEE PREVIOUS REQUESTED CODES AND NOTES WERE
 PLACED ON D-1 AND NOT ON ELECTRICAL SHEETS. THIS
 INLCUDES THE NOTES FOR RECESSED LIGHTING REQUIREMENTS
 AND CORRECT ADOPTED CODES FOR DESIGN.( PLEASE PLACE ON
 ELECTRICAL SHEETS).
 * NOTES ON ELECTRICAL SHEETS IN LEGEND STILL INDICATE
 THE 2002 NEC.
 * PLEASE SEE GFI PROTECTION IS REQUIRED FOR "ALL"
 RECEPTS WITHIN 6FT OF LAUNDRY ROOM SINK WHICH ARE 125V
 15 OR 20 AMP. (INCLUDING DEDICATED USE RECEPTS, THIS
 WAS CHANGED IN THE 2005 NEC )
  
 ** PLEASE CORRECT THE ABOVE ALONG WHEN ANY OTHER
 REVISIONS ARE MADE TO PLANS.
  
  
 SOME SHEETS STILL NOT DATED BY THE ARCHITECT.(
 ELECTRICAL SHEETS OK).

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2007-03-20 Cont ID  
Sent By dpalmer Date 2007-03-20 Time 20:04 Rev Time 0.00
Received By dpalmer Date 2007-03-20 Time 19:45 Sent To Z
Notes
2007-03-20 20:04:51ROUTED BACK TO ZONING.
2007-03-20 20:04:28*** UNSAT ***
  
 6623 SPARROW HAWK DR.
  
  
 1) NOTE: PLEASE BE SURE ALL PLANS REFLECT THE LATEST
 ADOPTED CODES PER THE STATE OF FLORIDA. PLEASE SEE THE
 FOLLOWING WHICH ARE CURRENTLY ADOPTED AS OF DECEMBER
 8TH, 2006.
 2004 FBC W/ 2006 REVISION. (THIS WILL AFFECT PLANS
 SUBMITTED).
 2005 NFPA-70 (NEC).
 2002 NFPA-72
 2003 NFPA-101
 ** THESE CODES ARE REQUIRED AT A MINIMUM FOR THIS TRADE
 REVIEWER; OTHERS MAY BE REQUIRED PER OTHER TRADES OR
 REVIEWER(S).
 PLEASE SEE THERE ARE MANY AREAS ON THE PLANS WHICH
 REFERENCE OLDER CODES FROM PREVIOUS CODES, THESE SHOULD
 BE REVISED ACCORDINGLY.
  
 2) NOTE: PLEASE SEE 2004 FBC W/2006 FOR NOTE REQUIRED
 FOR TYPE OF RECESSED LIGHTING FIXTURES PER
 13-606.1.ABC.1.2.4
  
 3) NOTE: PLEASE SEE 250.53G AS THE MINIMUM SIZE OF THE
 GROUND ROD SHALL BE 8FT MINIMUM.
  
 4) NOTE: PLEASE SEE THE COMPRESSOR FOR THE A/C CU IS
 BEING SHOWN WITH A LOAD OF 9.8KW; PLEASE VERIFY THIS AS
 THIS LOAD EXCEED THAT OF THE RATING OF THE CIRCUIT
 BREAKER.
 THIS WAS REDLINED ON PREVIOUS PLANS ON MANY OCCASIONS
 BUT TO DATE NO CHANGES HAVE BEEN MADE.
  
 5) NOTE: PLEASE SEE THAT THE USE OF SD FOR SMOKE
 DETECTORS ON PLANS FOR RESIDENTIAL HOMES IS NOT
 ACCEPTABLE WHEN THESE DEVICES ANY ACTUALLY FALL UNDER
 THE DEFINITIONS OF SMOKE ALARMS WHICH WOULD BE SHOWN AS
 SA/SMOKE ALARMS.
 THE GENERAL USE OF THE SD FOR SMOKE DETECTORS WAS
 ALWAYS ACCEPTEDHOWEVER BASED ON THE DEFINITIONS AS
 STATED IN NFPA-72 A SD/ SMOKE DETECTOR IS ONLY A DEVICE
 WHICH WILL DETECT AND WILL NOT SOUND AN AUDIBLE ALARM.
 THIS WOULD BE DONE BY HORN/SIREN TYPE DEVICES. PLEASE
 SEE THE DEFINITIONS OF SA/SMOKE ALARMS; THESE ARE
 DEVICES WHICH ARE 120V (AS SHOWN) AND WOULD DETECT AND
 SOUND AN ALARM. THIS IS SOMETHING THAT IS NOW BEING
 COMMENTED ON OTHER REVIEWS FOR OTHER NEW HOMES.
 ** PLEASE SEE THAT SMOKE ALARMS ARE STATED IN THE FBC
 RESIDENTIAL CODE/ FBC AND IN NFPA-72.
 IF THERE ARE ANY QUESTIONS ON THIS COMMENT PLEASE DO
 NOT HESITATE IN CONTACTING THIS OFFICE.
  
 6) NOTE: PLEASE SEE THAT UNDER THE NEW 2005 NEC
 210.8A7, ALL 15/20 AMP 125V RECEPTACLES WITHIN 6FT OF
 SINKS SHALL CONTAIN GFI PROTECTION EVEN LAUNDRY ROOMS
 AND WASHING MACHINES LOCATED WITHIN 6FT EVEN IF THEY
 ARE ON A DEDICATED/SINGLE RECEPTACLE.
  
 ** IMPORTANT**
 ONCE ALL REVIEWS ARE DONE AND PLANS ARE
 PICKED UP FOR CORRECTIONS, PLEASE BE
 SURE TO COMPLETELY REMOVE ALL OLD/VOIDED
 SHEETS AND ONLY INSERT NEW REVISED
 SHEETS INTO TWO COMPLETE SETS FOR REVIEW
 AND STAMPING. DO NOT LEAVE ANY
 OLD/VOIDED SHEETS IN SETS.
 PLEASE KNOW ONLY ONE SET OF THE
 OLD/VOIDED SHEETS SHOULD BE SUBMITTED
 FOR REFERENCE.
 THIS WILL HELP IN THE REVIEW PROCESS AND
 AVOID ANY DELAYS.
  
 ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR
 COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF
 THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY,
 NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO
 NOT HESITATE IN CONTACTING THIS OFFICE AND THIS
 REVIEWER.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPT.
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2008-04-02 Cont ID  
Sent By adarroug Date 2008-04-02 Time 14:56 Rev Time 0.00
Received By adarroug Date 2008-04-02 Time 14:56 Sent To Z
Notes
2008-04-02 14:56:32TO "Z" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2008-01-04 Cont ID  
Sent By adarroug Date 2008-01-04 Time 11:48 Rev Time 0.00
Received By adarroug Date 2008-01-04 Time 11:48 Sent To E
Notes
2008-01-04 11:49:14TO "DPALMER" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2007-08-24 Cont ID  
Sent By adarroug Date 2007-08-24 Time 16:37 Rev Time 0.00
Received By adarroug Date 2007-08-24 Time 16:37 Sent To P
Notes
2007-08-24 16:38:54TO "P" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2007-07-23 Cont ID  
Sent By adarroug Date 2007-07-23 Time 15:22 Rev Time 0.00
Received By adarroug Date 2007-07-23 Time 15:22 Sent To E
Notes
2007-07-23 15:23:12TO "DPALMER" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2007-05-24 Cont ID  
Sent By adarroug Date 2007-05-24 Time 13:31 Rev Time 0.00
Received By adarroug Date 2007-05-24 Time 13:31 Sent To E
Notes
2007-05-24 13:32:17TO "E" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-03-24 Cont ID  
Sent By adarroug Date 2007-03-24 Time 12:08 Rev Time 0.00
Received By adarroug Date 2007-03-24 Time 12:08 Sent To M
Notes
2007-03-24 12:08:52TO "SFR" "M"

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2007-04-19 Time   Rev Time 0.00
Received By adarroug Date 2007-03-20 Time 11:11 Sent To  
Notes
2007-03-20 11:12:08TO "SFR" "Z"

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2007-03-27 Cont ID  
Sent By tgordon Date 2007-03-27 Time 12:04 Rev Time 0.30
Received By tgordon Date 2007-03-27 Time 12:04 Sent To P
Notes
2007-03-27 12:06:33*** PROVISO ***
 1) DUCTS IN THE GARAGE AND DUCTS
 PENETRATING THE WALLS OR CEILINGS
 SEPARATING THE DWELLING FROM THE GARAGE
 SHALL BE CONSTRUCTED OF A MINIMUM NO. 26
 GAGE SHEET STEEL OR OTHER APPROVED
 MATERIAL AND SHALL HAVE NO OPENINGS INTO
 THE GARAGE. PER 2004 FBC/R 309.1.1 .
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop P PLUMBING
Rev No 4 Status P Date 2007-09-12 Cont ID  
Sent By mperson Date 2007-09-12 Time 09:44 Rev Time 0.00
Received By mperson Date 2007-09-12 Time 09:44 Sent To PC
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status F Date 2007-08-07 Cont ID  
Sent By mperson Date 2007-08-07 Time 09:49 Rev Time 0.45
Received By mperson Date 2007-08-07 Time 09:49 Sent To B
Notes
2007-08-07 10:17:18DENIED 3RD TIME
 REFERENCE:
 ** FBC-2004 PLUMBING.
 ** FBC-2004 CHAPTER 1, THE CITY OF
 WEST PALM BEACH AMENDMENTS.
 ** FLORIDA ADMINISTRATIVE CODE.
 ** FLORIDA STATUTES.
  
 1. SHEET PE-1: THE RESUBMITTED SANITARY ISOMETRIC
 RISER DIAGRAM DOES NOT REFLECT THE FLOOR PLAN OF THE
 UNDERGROUND SANITARY PLUMBING BEING INDICATED ON SHEET
 A-1.0. PLEASE REFERENCE THE SANITARY ISOMETRIC RISER
 DIAGRAM THAT REFLECTS THE FLOOR PLAN ATTACHED TO THESE
 PLUMBING COMMENTS FOR THE NEXT RESUBMITTAL.
  
 PER FBC-2004 CHAPTER 1 SECTION 106.1.1 INFORMATION ON
 CONSTRUCTION
 DOCUMENTS. CONSTRUCTION DOCUMENTS SHALL
 BE OF SUFFICIENT CLARITY TO INDICATE THE
 LOCATION, NATURE AND EXTENT OF THE WORK
 PROPOSED AND SHOW IN DETAIL THAT IT WILL
 CONFORM TO THE PROVISIONS OF THIS CODE
 AND RELAVENT LAWS, ORDINANCES, RULES AND REGULATIONS,
 AS DETERMINED BY THE
 BUILDING OFFICIAL.
  
 2. PER FBC-2004 CHAPTER 1, SECTION 106.3.5.4
 RESIDENTIAL (ONE AND TWO-FAMILY) PLEASE SUBMIT A
 PLUMBING SANITARY ISOMETRIC RISER DIAGRAM INDICATING
 ALL WASTE, VENTS, TRAPS AND SIZES WITH CLEANOUT
 LOCATIONS.
 NOTE: NOT ALL PIPE SIZES AND TRAPS ARE INDICATED ON THE
 RESUBMITTED SANITARY ISOMETRIC.
  
 ********IMPORTANT INFORMATION********
 IN ORDER TO EXPIDITE PLAN REVIEW: WHEN RESUBMITTING,
 PLEASE REPLACE ONLY SHEETS
 WHICH HAVE CHANGED, PLEASE INCLUDE A
 TRANSMITTAL LETTER INDICATING HOW EACH
 ITEM WAS ADDRESSED AND PROVIDE ONE COPY
 OF ALL OLD/VOIDED SHEETS FOR REFERENCE
 ONLY.
 NOTE: ONLY ONE CORRECTED DRAWING
 IN RED INK FOR REFERENCE FOR
 RESUBMITTAL.
  
  
 END OF COMMENTS:
  
 REVIEW BY MIKE PERSON
 PLUMBING PLANS EXAMINER
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL= [email protected]
  

Review Stop P PLUMBING
Rev No 2 Status F Date 2007-06-18 Cont ID  
Sent By mperson Date 2007-06-18 Time 08:39 Rev Time 0.00
Received By mperson Date 2007-06-18 Time 09:44 Sent To B
Notes
2007-06-18 09:21:04DENIED 2ND TIME
 REFERENCE:
 ** FBC-2004 PLUMBING.
 ** FBC-2004 CHAPTER 1, THE CITY OF
 WEST PALM BEACH AMENDMENTS.
 ** FLORIDA ADMINISTRATIVE CODE.
 ** FLORIDA STATUTES.
  
 ** PLEASE SEE SOME NOTES FROM PREVIOUS REVIEW ARE STILL
 IN NEED OF ADDRESSING ALONG WITH SOME NEW COMMENTS,
 SOME BASED ON PLANS NOW SUBMITTED, NEW DOCUMENTS BEING
 REVIEWED FOR THE FIRST TIME AND SOME NEW COMMENTS NOT
 MADE ON PREVIOUS REVIEWS.
  
 ** PLEASE SEE THE NOTES BELOW ARE TAKEN DIRECTLY FROM
 PREVIOUS REVIEW WITH A NO, OK OR A NO/OK.
 THESE WILL BE FOR THE EXACT NUMERICAL NOTATION OF THE
 PREVIOUS REVIEW NOTES.
  
 A NO IS IF THE COMMENT WAS NOT FULLY ADDRESSED AND/OR
 FURTHER EXPLANATION OR CHANGES IN PLANS OR DOCUMENTS
 ARE STILL NEEDED. THIS REVIEWER WILL TRY TO BETTER
 EXPLAIN NOTE ABOVE PREVIOUS REVIEW COMMENT.
  
 AN OK WILL BE LABELED AS SUCH ON THE SAME NUMERICAL
 COMMENT AND WILL HAVE OLD NOTE REMOVED FROM COMMENTS.
  
 A NO/OK MEANS PART OF THE COMMENT MAY HAVE BEEN
 ADDRESSED, HOWEVER NOT ALL OF THE PREVIOUS REVIEW
 COMMENT MAY HAVE BEEN FULLY ADDRESSED.
  
 ** PLEASE SEE ANY NEW NOTES WILL BE ADDED TO THE END OF
 THE PREVIOUS REVIEW COMMENTS AND NOTED AS SUCH.
  
 1. **OK**
  
 2. SHEET A-1.0 SANITARY RISER DIAGRAM: PLEASE SEE THAT
 THERE IS STILL AN ISSUE WITH D}. PLEASE CORREC THIS ON
 THE RESUBMITTAL.
 A} **OK**
 B} **OK**
 C} **OK**
 D} **NO** A VENT IS BEING INDICATED ON THE FLOOR
 PLAN PLUMBING ON THIS SHEET, BUT IS MISSING ON THE
 RISER DIAGRAM. A VENT IS STILL REQUIRED AND NEEDS TO BE
 INDICATED FOR BATH #3 SHOWER. PER FBC-2004 PLUMBING,
 SECTION 901.2.1.
  
 THE FOLLOWING IS A NEW ITEM:
  
 3. SHEET A-1.0 LAUNDRY: THE SANITARY RISER DIAGRAM
 DOES NOT RELECT THE FLOOR PLAN IN THE LAUNDRY FOR THE
 WASHING MACHINE. THE RESUBMITTED THREE INCH (3") BRANCH
 IS BEING INDICATED ON THE WRONG SIDE OF THE LAUNDRY
 TRAY AND THE FLOW IS WRONG. PLEASE CORRECT THIS ON THE
 RESUBMITTAL.
 106.1.1 INFORMATION ON CONSTRUCTION
 DOCUMENTS. CONSTRUCTION DOCUMENTS SHALL
 BE OF SUFFICIENT CLARITY TO INDICATE THE
 LOCATION, NATURE AND EXTENT OF THE WORK
 PROPOSED AND SHOW IN DETAIL THAT IT WILL
 CONFORM TO THE PROVISIONS OF THIS CODE
 AND RELAVENT LAWS, ORDINANCES, RULES AND REGULATIONS,
 AS DETERMINED BY THE
 BUILDING OFFICIAL.
  
 ********IMPORTANT INFORMATION********
 IN ORDER TO EXPIDITE PLAN REVIEW: WHEN RESUBMITTING,
 PLEASE REPLACE ONLY SHEETS
 WHICH HAVE CHANGED, PLEASE INCLUDE A
 TRANSMITTAL LETTER INDICATING HOW EACH
 ITEM WAS ADDRESSED AND PROVIDE ONE COPY
 OF ALL OLD/VOIDED SHEETS FOR REFERENCE
 ONLY.
 NOTE: ONLY ONE CORRECTED DRAWING
 IN RED INK FOR REFERENCE FOR
 RESUBMITTAL.
  
 END OF COMMENTS:
  
 REVIEW BY MIKE PERSON
 PLUMBING PLANS EXAMINER
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL [email protected]
 UNDER SUPERVISION OF K.STEVENS
 (561) 805-6721

Review Stop P PLUMBING
Rev No 1 Status F Date 2007-04-03 Cont ID  
Sent By dpalmer Date 2007-06-03 Time 11:34 Rev Time 0.55
Received By mperson Date 2007-04-03 Time 09:10 Sent To B
Notes
2007-04-03 09:35:06DENIED
 REFERENCE:
 ** FBC-2004 PLUMBING.
 ** FBC-2004 CHAPTER 1, THE CITY OF
 WEST PALM BEACH AMENDMENTS.
 ** FLORIDA ADMINISTRATIVE CODE.
 ** FLORIDA STATUTES.
  
 THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR
 PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE:
  
 1. FAC-61G1-16.004 TITLE BLOCK:
 A TITLE BLOCK MUST APPEAR ON ALL
 ARCHITECTURAL OR INTERIOR DESIGN
 DRAWINGS AND SPECIFICATION
 IDENTIFICATION SHEETS. THE TITLE BLOCK
 MUST, AT A MINIMUM, CONTAIN THE
 FOLLOWING INFORMATION:
 (1) FIRM NAME, ADDRESS, AND TELEPHONE
 NUMBER.
 (2) FIRM LICENSE NUMBER.
 (3) NAME OR IDENTIFICATION OF PROJECT.
 (4) DATE PREPARED.
 (5) A SPACE FOR THE SIGNATURE AND DATED
 SEAL.
 (6) A SPACE FOR THE PRINTED NAME OF THE
 PERSON SEALING THE DOCUMENT.
 NOTE: NUMBER (6)A SPACE FOR THE PRINTED NAME OF THE
 PERSON SEALING THE DOCUMENT IS MISSING FROM SHEETS.
 PLEASE CORRECT ON THE RESUBMITTAL.
  
 2. SHEET A-1.O ISOMETRIC SANITARY RISER DIAGRAM PLEASE
 CORRECT THE FOLLOWING ON THE RESUBMITTAL:
  
 A} THE SHOWER IN BATH #2 IS INCORRECTLY INDICATED AS A
 TUB WASTE AND OVERFLOW.
  
 B} WASHING MACHINE BRANCH DRAIN AND DRAINAGE STACK NEED
 TO BE 3 INCH PER FBC-2004 PLUMBING, SECTION 406.3.
  
 C} CLEANOUT FOR WASHING MACHINE IS INCORRECTLY
 INDICATED AT THE BASE OF THE DRAINAGE STACK AND DOES
 NOT REFLECT THE NOTES AT BEING 4' A.F.F.
  
 D} VENT REQUIRED FOR BATH #3 SHOWER PER FBC-2004
 PLUMBING, SECTION 901.2.1.
  
 ********IMPORTANT INFORMATION********
 IN ORDER TO EXPIDITE PLAN REVIEW: WHEN RESUBMITTING,
 PLEASE REPLACE ONLY SHEETS
 WHICH HAVE CHANGED, PLEASE INCLUDE A
 TRANSMITTAL LETTER INDICATING HOW EACH
 ITEM WAS ADDRESSED AND PROVIDE ONE COPY
 OF ALL OLD/VOIDED SHEETS FOR REFERENCE
 ONLY. NOTE: ONLY ONE CORRECTED DRAWING
 IN RED INK FOR REFERENCE FOR
 RESUBMITTAL.
  
 END OF COMMENTS:
  
 REVIEW BY MIKE PERSON
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL [email protected]
 UNDER SUPERVISION OF K.STEVENS
 (561) 805-6721
  

Review Stop Z ZONING
Rev No 2 Status P Date 2008-04-03 Cont ID  
Sent By choops Date 2008-04-03 Time 10:53 Rev Time 0.00
Received By choops Date 2008-04-03 Time 10:53 Sent To PC
Notes
2008-04-03 10:53:57***APPROVED - LANDSCAPE PLAN SUBMITTAL***

Review Stop Z ZONING
Rev No 1 Status P Date 2007-03-22 Cont ID  
Sent By jroach Date 2007-03-22 Time 14:28 Rev Time 0.00
Received By jroach Date 2007-03-22 Time 14:28 Sent To I
Notes
2007-03-22 14:28:56PASSED, PER A. JONES-VANN.