Plan Review Details - Permit 07030550
Plan Review Stops For Permit 07030550
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2007-06-11 Cont ID  
Sent By shill Date 2007-06-11 Time 15:38 Rev Time 0.00
Received By shill Date 2007-06-11 Time 15:38 Sent To  
Notes
2007-06-11 15:45:55****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2004
 FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
  
 1.)HAVE AN ENGINEER CERTIFY THE BUILDING HEIGHT.
 THIS IS BEING REQUESTED BECAUSE OTHER CONTRACTORS HAVE
 DECLARED A BUILDING HEIGHT HIGHER THAN 173' FOR THIS
 BUILDING.
  
 2.)SEE NOTE 2G.AN ARCHITECT OR ENGINEER IS TO
 DECLARE THE BUILDING AS ENCLOSED; OTHERWISE PARTIALLY
 ENCLOSED PRESSURES MUST BE USED.
  
 3.)THE RESUBMITTAL SHEET HAS A NOTE FROM THE
 CONTRACTOR STATING THAT THIS UNIT IS "WELL IN EXPOSURE
 B".THIS IS CONFUSING AS THE JOB IS IN EXPOSURE C PER
 FBC1609.6.2.1(2), YOUR PAPERWORK IS FOR EXPOSURE C,
 THIS WAS NOT A CORRECTION ON THE FIRST REVIEW, AND THE
 SCALED MAP WHICH YOU REFER TO IN YOUR NOTE WAS NOT IN
 THE PACKAGE.
  
 4.)THIS JOB IS NOT WITHIN THE SCOPE OF A CBC LICENSE
 (EXTERIOR WALLS AND WINDOWS ARE A STRUCTURAL COMPONENT
 OF THE BUILDING).

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-03-24 Cont ID  
Sent By shill Date 2007-03-24 Time 14:49 Rev Time 0.00
Received By shill Date 2007-03-24 Time 14:49 Sent To  
Notes
2007-03-24 14:49:31****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL
 FBC*CITY OF WEST PALM BEACH AMENDMENTS TO THE
 FBC2004
 FACFLORIDA ADMINISTRATIVE CODE
 FSFLORIDA STATUTE
  
 ***WINDOW OR DOOR PERMIT APPLICATION, ONLY CHECKED
 ITEMS APPLY***
  
 ____1.A NOTICE OF COMMENCEMENT MUST BE FILED WITH
 THE CLERK OF COURTS PRIOR TO PERMIT PICKUP, FS713.13.
  
 _XX_2.PROVIDE BUILDING HEIGHT.DESIGN PRESSURES
 FOR BUILDINGS OVER 60FEET ARE REQUIRED TO BE DESIGNED
 USING ASCE7, FBC1609.1.1. DOCUMENTS PREPARED BY AN
 ENGINEER AND SUBMITTED FOR PUBLIC RECORD ARE TO BE
 SIGNED SEALED ORIGINALS FAC61G15-23.002.
  
 ____3.PROVIDE A COPY OF THE CONDO ASSOCIATION
 APPROVAL.
  
 ____4.IMPACT PROTECTION REQUIRED,FBC1609.1.4, FBC R
 301.2.1.2.IF LESS THAN 25% OF THE TOTAL GLAZED AREA
 IS BEING REPLACED, PROVIDE CALCULATIONS FBC EB507.3.
  
 ____5.FLORIDA STATE OR LOCAL PRODUCT APPROVAL
 REQUIRED, FAC9B72, WWW.FLORIDABUILDING.ORG.
  
 ____6.PROVIDE A FLOOR PLAN SHOWING: WINDOW
 LOCATIONS, SIZES, WINDOW TYPE, ROOM DESIGNATIONS.NOTE
 EXISTING CONDITIONS (TYPE OF WINDOW) AND OPENING SIZE
 FOR BEDROOMS, FBC R310, FBC EB 505.1.
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2007-05-17 Cont ID  
Sent By adarroug Date 2007-05-17 Time 15:42 Rev Time 0.00
Received By adarroug Date 2007-05-17 Time 15:42 Sent To B
Notes
2007-05-17 15:42:48TO "SHILL' DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-04-19 Cont ID  
Sent By adarroug Date 2007-04-19 Time 16:18 Rev Time 0.00
Received By adarroug Date 2007-04-19 Time 16:18 Sent To B
Notes
2007-04-19 16:19:15TO "SHILL" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-03-24 Cont ID  
Sent By shill Date 2007-03-24 Time 14:49 Rev Time 0.00
Received By shill Date 2007-03-15 Time 16:01 Sent To  
Notes
2007-03-15 16:01:46TO "MISC" BOX#1

Review Stop Z ZONING
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved