Plan Review Stops For Permit 07030543 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2007-12-21 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2007-12-21 |
Time |
14:38 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2007-12-21 |
Time |
14:38 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2007-09-28 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2007-09-28 |
Time |
10:01 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2007-09-28 |
Time |
10:01 |
Sent To |
|
|
Notes |
2007-09-28 11:11:25 | 2007 FBC W/2006 REVISIONS | | | | DENIED BY BUILDING | | | | 1) A RECORDED COPY OF THE NOTICE OF COMMENCEMENT | | MUST BE SUBMITTED BEFORE A | | PERMIT CAN BE ISSUED. | | | | 2) THE DECORATIVE CHIMNEY THAT HAS BEEN DELETED IS | | STILL SHOWN ON THE ELEVATIONS ON SHEET A9. PLEASE | | CORRECT. | | | | 3) SUBMIT PRODUCT APPROVALS FOR THE STRUCTURAL MULLIONS | | AND THE FIXED GLASS TRANSOM WINDOW ABOVE THE FRONT | | WINDOWS (MARK A). | | | | 4) THE 32" X 68" (MARK A) WINDOWS EXCEED THE MAXIMUM | | SIZE LISTED IN THE PRODUCT APPROVAL NOA FOR THE SINGLE | | OPERABLE CASEMENT WINDOWS. PLEASE SUBMIT A PRODUCT | | APPROVAL FOR THESE WINDOWS OR REVISE THE SIZE. SEE THE | | DESIGN LOAD CAPACITY TABLES ON SHEET 7 OF NOA NO. | | 02-1113.04. | | | | 5) NOTE: THE PRODUCT APPROVALS SUBMITTED FOR THE | | WINDOWS HAVE BEEN TESTED FOR LARGE MISSILE IMPACT AND | | STORM PANELS ARE NOT REQUIRED. ALSO THE WINDOWS ARE | | REQUIRED TO MEET THE WINDLOAD PRESSURES REGARDLESS OF | | BEING SHUTTERED. | | | | - ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2007-04-23 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2007-04-23 |
Time |
10:29 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2007-04-23 |
Time |
07:01 |
Sent To |
|
|
Notes |
2007-04-23 07:16:20 | DENIED BY BUILDING | | | | 1) A RECORDED COPY OF THE NOTICE OF COMMENCEMENT | | MUST BE SUBMITTED BEFORE A | | PERMIT CAN BE ISSUED. | | | | 2) IMPACT FEES MUST BE PAID TO PALM | | BEACH COUNTY, PLANS STAMPED BY THEM AND | | COPY OF RECEIPT SUBMITTED TO CITY OF | | WEST PALM BEACH BUILDING DEPARTMENT, | | BEFORE A BUILDING PERMIT CAN BE ISSUED. | | | | 3) THE LICENSE NUMBER FOR THE ARCHITECTURAL FIRM IS | | MISSING FROM THE TITLE BLOCK. SEE FAC 61G1-16.004. | | | | 4) FBC TABLE R301.5 REQUIRES EXTERIOR BALCONIES TO HAVE | | A LIVE LOAD OF 60 PSF. PLEASE CORRECT THE STRUCTURAL | | NOTE ON SHEET A2. | | | | 5) ON SHEET A2 COLUMNS C8 ARE INCORRECTLY SPECIFIED AT | | THE FRONT ENTRY. | | | | 6) SPECIFY THE SIZES OF THE ATTIC ACCESSES ON THE | | PLANS. | | | | 7) SUBMIT THE MANUFACTURER'S SPECIFICATIONS, | | INSTALLATION INSTRUCTIONS AND LISTING INFORMATION FOR | | THE ISOKERN FLUELESS FIREPLACE. | | | | 8) SUBMIT THE MANUFACTURER'S SPECIFICATIONS, | | INSTALLATION INSTRUCTIONS AND LISTING INFORMATION FOR | | THE GAS BBQ ON THE LOGGIA. NOTE: THE CEILING OF THE | | LOGGIA IS COVERED WITH FLAMMABLE MATERIAL. | | | | 9) SUBMIT THE MANUFACTURER'S SPECIFICATIONS AND | | INSTALLATION INSTRUCTIONS FOR THE SPRAY FOAM INSULATION | | THAT WILL BE INSTALLED IN THE VENTLESS ATTIC. | | | | 10) PROVIDE ADDITIONAL INFORMATION FOR THE CHIMNEY. IS | | THIS A DECORATIVE ASSEMBLY OR WILL IT BE FUNCTIONING? | | PROVIDE DETAILS FOR THE CHIMNEY CAP SHOWN ON THE | | ELEVATIONS ON A8. THE ELEVATION SHOWS A STUCCO BAND | | WHICH IS NOT SHOWN ON THE STRUCTURAL DETAILS. THE | | TRUSSES WILL BE REQUIRED TO BE DESIGNED FOR THE CHIMNEY | | ATTACHMENT. | | | | 11) SHOW COMPLIANCE WITH R502.12 DRAFTSTOPPING | | REQUIRED. | | WHEN THERE IS USABLE SPACE BOTH ABOVE AND BELOW THE | | CONCEALED SPACE OF A FLOOR/CEILING ASSEMBLY, DRAFTSTOPS | | SHALL BE INSTALLED SO THAT THE AREA OF THE CONCEALED | | SPACE DOES NOT EXCEED 1,000 SQUARE FEET (92.9 M 2 ). | | DRAFTSTOPPING SHALL DIVIDE THE CONCEALED SPACE INTO | | APPROXIMATELY EQUAL AREAS. WHERE THE ASSEMBLY IS | | ENCLOSED BY A FLOOR MEMBRANE ABOVE AND A CEILING | | MEMBRANE BELOW DRAFTSTOPPING SHALL BE PROVIDED IN | | FLOOR/CEILING ASSEMBLIES UNDER THE FOLLOWING | | CIRCUMSTANCES: | | 1.CEILING IS SUSPENDED UNDER THE FLOOR FRAMING. 2. | | FLOOR FRAMING IS CONSTRUCTED OF TRUSS-TYPE OPEN-WEB OR | | PERFORATED MEMBERS. | | SPECIFY THE LOCATION OF DRAFTSTOPPING AND MATERIAL THAT | | WILL BE USED. SEE R502.12.1. | | | | 12) PLEASE REVISE ROOF SHEATHING FASTENING NOTES ON A7. | | THE 2006 REVISIONS TO THE 2004 FBC REQUIRES RING SHANK | | NAILS TO BE USED IN ALL ROOF ZONES. FBC R803.2.3.1 | | | | 13) SPECIFY THE TREAD DEPTH OF THE STAIRS ON SHEET A11. | | SEE R311.5.3.2. | | | | 14) SPECIFY THE ATTACHMENT THAT WILL BE USED FOR THE | | MONIER CONCRETE ROOF TILES. CIRCLE THE APPROPRIATE | | FASTENER OR ADHESIVE ON THE PRODUCT APPROVAL. | | | | 15) SUBMIT PRODUCT APPROVALS FOR THE TRUSS CONNECTORS. | | | | 16) SUBMIT DRAWING #IRC-5316-175-45 WHICH IS REQUIRED | | TO ACCOMPANY THE PRODUCT APPROVAL FOR THE OVERHEAD | | GARAGE DOOR. | | | | 17) SUBMIT PRODUCT APPROVALS FOR THE STRUCTURAL | | MULLIONS, RAISED PANEL/HALF GLASS DOORS AT THE GARAGE | | AND LAUNDRY ROOM, THE 4' X 8' MAHOGANY ENTRY DOOR AND | | THE FIXED GLASS TRANSOM WINDOW ABOVE WINDOW A. | | | | 18) THE FLORIDA COVERSHEET SUBMITTED FOR THE MARVIN | | IMPACT CASEMENT WINDOW IS NOT THE CORRECT ONE FOR NOA | | 02-1113.04. IF THERE IS NO FL# THAT CORRESPONDS TO IT, | | THE NOA IS ACCEPTABLE WITHOUT THE FL COVERSHEET. | | HOWEVER, IT IS STILL REQUIRED TO BE APPROVED IN WRITING | | BY THE DESIGNER OF RECORD. | | | | 19) THE PRODUCT APPROVALS THAT WERE SUBMITTED FOR THE | | CASEMENT WINDOWS DO NOT HAVE DESIGN PRESSURES ON PAGE 7 | | OF THE NOA THAT ARE ACCEPTABLE FOR WINDOWS A & K AS | | SPECIFIED IN THE SCHEDULE ON A5. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2009-06-22 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2009-06-22 |
Time |
11:09 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2009-06-22 |
Time |
10:41 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2007-09-11 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2007-09-11 |
Time |
11:04 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2007-09-11 |
Time |
10:45 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2007-03-16 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2007-03-16 |
Time |
08:47 |
Rev Time |
1.50 |
Received By |
btrobaug |
Date |
2007-03-15 |
Time |
17:44 |
Sent To |
Z |
|
Notes |
2007-03-16 08:47:09 | | | | | NONCOMPLIANT | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS FOR CODE | | COMPLIANCE AND RESUBMIT FOR REVIEW. | | | | 1} 210.52(B)(2) ISLAND COUNTER SPACES AT LEAST ONE | | RECEPTACLE SHALL BE INSTALLED AT EACH ISLAND COUNTER | | SPACE WITH A LONG DIMENSION OF 600 MM (24 IN.) OR | | GREATER AND A SHORT DIMENSION OF 300 MM (12 IN.) OR | | GREATER. WHERE A RANGETOP OR SINK IS INSTALLED IN AN | | ISLAND COUNTER AND THE WIDTH OF THE COUNTER BEHIND THE | | RANGETOP OR SINK IS LESS THAN 300 MM (12 IN.), THE | | RANGETOP OR SINK IS CONSIDERED TO DIVIDE THE ISLAND | | INTO TWO SEPARATE COUNTERTOP SPACES AS DEFINED IN | | 210.52(C)(4). | | | | 2} 210.52(C)(1) WALL COUNTER SPACES A RECEPTACLE OUTLET | | SHALL BE INSTALLED AT EACH WALL COUNTER SPACE THAT IS | | 300 MM (12 IN.) OR WIDER. RECEPTACLE OUTLETS SHALL BE | | INSTALLED SO THAT NO POINT ALONG THE WALL LINE IS MORE | | THAN 600 MM (24 IN.) MEASURED HORIZONTALLY FROM A | | RECEPTACLE OUTLET IN THAT SPACE. | | | | 2} THE CONDENSER DISCONNECTS DO NOT MEET 110.26 | | CLEARANCE REQUIREMENTS. | | | | 3} THE 2005 NEC WAS ADOPTED BY THE FLORIDA LEGISLATURE | | EFFECTIVE 8 DECEMBER 2006. THE APPLICATION FOR THIS | | PROJECT WAS AFTER THAT DATE AND THE PLANS ARE SUBJECT | | TO THAT CODE. PLEASE CHANGE ALL NOTES TO REFLECT THIS | | CHANGE. | | | | 4} NOTE #20 INCORRECTLY REFERENCES 2204 FBC AND 907 | | NFPA-72. THE CORRECT REFERENCE STANDARDS PER 2004 FBC | | ARE R313 RESIDENTIAL AND CHAPTER 11NFPA-72, 2002 | | EDITION. PLEASE CORRECT FOR CLARITY IN THE FIELD. | | | | 5} A RECEPTACLE, AS WELL AS THE LIGHT INDICATED ON | | SHEET E-2, IS REQUIRED IN THE ATTIC FOR SERVICING THE | | AIR HANDLER PER 210.63 NEC AND M1305.1.3.1 FBC. | | | | 6} A RECEPTACLE PER 210.52(D) IS REQUIRED IN BATH #1 | | SHEET E-2. | | | | NOTE: THE #2 EQUIPMENT GROUND RAN WITH THE PANEL | | FEEDERS, ALTHOUGH NOT A VIOLATION, IS ONLY REQUIRED TO | | BE #6CU. IF IT REMAINS #2 ON THE PLAN IT MUST BE | | INSTALLED OR A REVISION WILL BE REQUIRED TO MAKE THE | | CHANGE. | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | BILL TROBAUGH | | ELECTRICAL PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561/805-6718 | | [email protected] |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
4 |
Status |
P |
Date |
2009-06-02 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2009-06-02 |
Time |
09:53 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2009-06-02 |
Time |
09:53 |
Sent To |
|
|
Notes |
2009-06-02 09:54:32 | REVISION OK -- SHT M-3 CHANGED O 2 PSI SYSTEM, ADDED | | REGULATORS, CHANGED LENGTHS AND MATERIAL. |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
3 |
Status |
P |
Date |
2007-12-17 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2007-12-17 |
Time |
08:27 |
Rev Time |
0.00 |
Received By |
mperson |
Date |
2007-12-17 |
Time |
08:27 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
F |
Date |
2007-09-25 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2007-09-25 |
Time |
14:06 |
Rev Time |
0.00 |
Received By |
mperson |
Date |
2007-09-25 |
Time |
14:06 |
Sent To |
B |
|
Notes |
2007-09-25 14:39:37 | DENIED 2ND TIME | | REFERENCE: | | ** FBC-2004 WITH 2006 REVISIONS FUEL GAS. | | ** NFPA-2002 CHAPTER 54. | | ** THE CITY OF WEST PALM BEACH GAS PERMIT APPLICATION | | REQUIREMENTS. | | ** FBC-2004 CHAPTER 1, THE CITY OF | | WEST PALM BEACH AMENDMENTS. | | ** FLORIDA ADMINISTRATIVE CODE. | | ** FLORIDA STATUTES. | | | | ** PLEASE SEE SOME NOTES FROM PREVIOUS REVIEW ARE STILL | | IN NEED OF ADDRESSING ALONG WITH SOME NEW COMMENTS, | | SOME BASED ON PLANS NOW SUBMITTED, NEW DOCUMENTS BEING | | REVIEWED FOR THE FIRST TIME AND SOME NEW COMMENTS NOT | | MADE ON PREVIOUS REVIEWS. | | | | ** PLEASE SEE THE NOTES BELOW ARE TAKEN DIRECTLY FROM | | PREVIOUS REVIEW WITH A NO, OK OR A NO/OK. | | THESE WILL BE FOR THE EXACT NUMERICAL NOTATION OF THE | | PREVIOUS REVIEW NOTES. | | | | A NO IS IF THE COMMENT WAS NOT FULLY ADDRESSED AND/OR | | FURTHER EXPLANATION OR CHANGES IN PLANS OR DOCUMENTS | | ARE STILL NEEDED. THIS REVIEWER WILL TRY TO BETTER | | EXPLAIN NOTE ABOVE PREVIOUS REVIEW COMMENT. | | | | AN OK WILL BE LABELED AS SUCH ON THE SAME NUMERICAL | | COMMENT AND WILL HAVE OLD NOTE REMOVED FROM COMMENTS. | | | | A NO/OK MEANS PART OF THE COMMENT MAY HAVE BEEN | | ADDRESSED, HOWEVER NOT ALL OF THE PREVIOUS REVIEW | | COMMENT MAY HAVE BEEN FULLY ADDRESSED. | | | | ** PLEASE SEE ANY NEW NOTES WILL BE ADDED TO THE END OF | | THE PREVIOUS REVIEW COMMENTS AND NOTED AS SUCH. | | | | 1. **OK** | | | | 2. **OK** | | | | 3. **NO/OK** SHEET M-3 | | SUBMIT AN ISOMETRIC DRAWING THAT | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE | | AND CORRESPONDING LENGTHS PER FBC-2004 | | FUEL GAS CODE. | | NOTE: THE RESUBMITTED ISOMETRIC IS NOT INDICATING ALL | | CORRESPONDING LENGTHS OF THE CUT SECTIONS. | | | | 4. **OK** | | | | 5. **OK** | | | | 6. **OK** | | | | 7. **NO/OK** SHEET M-3 | | SHOW THE DISTANCE FROM THE POINT OF | | DELIVERY, (METER), TO THE MOST REMOTE | | OUTLET IN THE BUILDING AND/OR SYSTEM PER | | FBC-2004 FUEL GAS CODE APPENDIX A - USE | | OF CAPACITY TABLES A.3.1(4). | | NOTE: THE INDICATED LONGEST LENGTH IS BEING INDICATED | | AS 145', THE TOTAL SUM OF THE INDICATED CUT SECTION | | CORRESPONDING LENGTHS IS 105'. PLEASE CORRELATE THE | | LONGEST LENGTHS ON THE RESUBMITTAL BY INDICATING ALL | | CORRESPONDING LENGTHS OF ALL CUT SECTIONS OF | | PIPE.(REFERENCE COMMENT #3) | | | | 8. **OK** | | | | 9. **OK** | | | | 10. **OK** | | | | **THE FOLLOWING IS A NEW COMMENT | | | | 11. SHEET M-3 THE RESUBMITTED GAS ISOMETRIC IS | | INDICATING THE GAS METER AS BEING UNDERGROUND. PER | | NFPA-2002 CHAPTER 54 SECTION 5.7.2.1 GAS METERS SHALL | | BE LOCATED IN VENTILATED SPACES READILY ACCESSIBLE FOR | | EXAMINATION, READING, REPACEMENT OR NECESSARY | | MAINTENANCE AND SECTION 5.7.2.2 GAS METERS SHALL NOT BE | | PLACED WHERE THEY WILL BE SUBJECT TO EXCESSIVE | | CORROSION. PLEASE INDICATE THE GAS METER AS BEING ABOVE | | GROUND AND INDICATE THE REQUIRED CORRESPONDING LENGTHS | | TO THE CUT SECTIONS TO CORRECT THIS ON THE | | RESUBMITTAL. | | | | ********IMPORTANT INFORMATION******** | | IN ORDER TO EXPIDITE PLAN REVIEW: WHEN RESUBMITTING, | | PLEASE REPLACE ONLY SHEETS | | WHICH HAVE CHANGED, PLEASE INCLUDE A | | TRANSMITTAL LETTER INDICATING HOW EACH | | ITEM WAS ADDRESSED AND PROVIDE ONE COPY | | OF ALL OLD/VOIDED SHEETS FOR REFERENCE | | ONLY. | | NOTE: THERE IS ONLY ONE CORRECTED DRAWING IN RED INK ON | | THE INDICATED PLAN SHEETS BY THIS PLAN EXAMINER FOR FOR | | REFERENCE FOR THE RESUBMITTAL. | | | | END OF COMMENTS: | | | | REVIEW BY MIKE PERSON | | PLUMBING PLANS EXAMINER | | (561) 805-6730 | | FAX (561) 805-6731 | | E-MAIL: [email protected] |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
F |
Date |
2007-03-30 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2007-03-30 |
Time |
16:07 |
Rev Time |
0.45 |
Received By |
mperson |
Date |
2007-03-30 |
Time |
16:07 |
Sent To |
B |
|
Notes |
2007-03-30 16:59:10 | DENIED | | REFERENCE: | | | | ** FBC-2004 FUEL GAS. | | ** THE CITY OF WEST PALM BEACH GAS PERMIT APPLICATION | | REQUIREMENTS. | | ** FBC-2004 CHAPTER 1, THE CITY OF | | WEST PALM BEACH AMENDMENTS. | | ** FLORIDA ADMINISTRATIVE CODE. | | ** FLORIDA STATUTES. | | | | THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR | | GAS PLAN REVIEW TO MEET CODE COMPLIANCE: | | | | 1. PLEASE REFERENCE PLUMBING COMMENT #1 IN RELATION TO | | FIRM LICENSE NUMBER REQUIRED IN TITLE BLOCK. | | | | 2. 106.1.1 INFORMATION ON CONSTRUCTION | | DOCUMENTS. CONSTRUCTION DOCUMENTS SHALL | | BE OF SUFFICIENT CLARITY TO INDICATE THE | | LOCATION, NATURE AND EXTENT OF THE WORK | | PROPOSED AND SHOW IN DETAIL THAT IT WILL | | CONFORM TO THE PROVISIONS OF THIS CODE | | AND RELAVENT LAWS, ORDINANCES, RULES AND REGULATIONS, | | AS DETERMINED BY THE | | BUILDING OFFICIAL. | | NOTE: THE SUBMITTED GAS ISOMETRIC ON SHEET M-3 DOES NOT | | REFLECT THE FLOOR PLANS ON SHEETS A-3 AND A-4. GAS | | ISOMETRIC INDICATES TWO RANGES IN DIFFERENT LOCATIONS | | BUT THE FLOOR PLANS ONLY INDICATE ONE RANGE IN THE | | KITCHEN. PLEASE CLARIFY ON THE RESUBMITTAL. | | | | 3. SUBMIT AN ISOMETRIC DRAWING THAT | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE | | AND CORRESPONDING LENGTHS PER FBC-2004 | | FUEL GAS CODE. | | NOTE: CORRESPONDING LENGTHS OF CUT SECTIONS ARE NOT | | INDICATED. | | | | 4. SHOW TYPE OF PIPING MATERIAL BEING | | INSTALLED, ALL PIPE SIZES, (AND THE EDH | | NUMBER OF CORRUGATED STAINLESS STEEL | | TUBING FOR EACH PIPE SIZE BEING USED. | | NOTE: NOT ALL PIPE SIZES ARE INDICATED AND IF BLACK | | STEEL PIPE IS BEING INSTALLED UNDERGROUND PLEASE ADD | | THE FOLLOWING TO "GAS NOTES" ON SHEET M-3. | | | | A} PER FBC-2004 FUEL GAS SECTION 404.8.2 PROTECTIVE | | COATINGS AND WRAPPING. PIPE PROTECTIVE COATINGS AND | | WRAPPINGS SHALL BE APPROVED FOR THE APPLICATION AND | | SHALL BE FACTORY APPLIED. | | | | | | 5. PLEASE INDICATE THE TYPE OF GAS, (LP OR NATURAL) | | BEING USED ON THE RESUBMITTAL. | | | | 6. INDICATE THE DELIVERY PRESSURE (PSI) | | PER FBC-2004 FUEL GAS CODE SEC. 402.2. | | NATURAL GAS SPECIFY .5 PSI OR 2 PSI. | | | | 7. CLEARLY SHOW THE DISTANCE FROM THE POINT OF | | DELIVERY, (METER), TO THE MOST REMOTE | | OUTLET IN THE BUILDING AND/OR SYSTEM ON THE ISOMETRIC | | PER | | FBC-2004 FUEL GAS CODE APPENDIX A - USE | | OF CAPACITY TABLES A.3.1(4). | | | | 8. PLEASE SUBMIT MANUFACTURER SPECIFICATIONS OF | | APPLIANCES (CUT SHEETS) VARIFYING BTU LOADS AND SHOWING | | LISTINGS FROM A NATIONALLY RECOGNIZED TESTING | | LABORATORY (NRTL). | | | | 9. PLEASE CLARIFY WHAT THE NIPPLE AND HARD CAP ON THE | | RUN OF THE TEE FOR THE POOL HEATER IS. IS THIS SUPPOST | | TO BE A SEDIMENT TRAP? IF SO ITS IN THE WRONG LOCATION. | | PLEASE CLARIFY ON THE RESUBMITTAL. | | | | 10. PLEASE DELETE THE SEDIMENT TRAP BEING INDICATED | | UNDERGROUND ON THE RESUBMITTAL. | | | | ********IMPORTANT INFORMATION******** | | IN ORDER TO EXPIDITE PLAN REVIEW: WHEN RESUBMITTING, | | PLEASE REPLACE ONLY SHEETS | | WHICH HAVE CHANGED, PLEASE INCLUDE A | | TRANSMITTAL LETTER INDICATING HOW EACH | | ITEM WAS ADDRESSED AND PROVIDE ONE COPY | | OF ALL OLD/VOIDED SHEETS FOR REFERENCE | | ONLY. NOTE: ONLY ONE CORRECTED DRAWING | | IN RED INK FOR REFERENCE FOR | | RESUBMITTAL. | | | | END OF COMMENTS: | | | | REVIEW BY MIKE PERSON | | (561) 805-6730 | | FAX (561) 805-6731 | | E-MAIL [email protected] | | UNDER SUPERVISION OF K.STEVENS | | (561) 805-6721 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2010-07-12 |
|
|
Cont ID |
|
Sent By |
vmolina |
Date |
2010-07-12 |
Time |
10:32 |
Rev Time |
0.00 |
Received By |
vmolina |
Date |
2010-07-12 |
Time |
10:31 |
Sent To |
|
|
Notes |
2010-07-12 10:32:14 | IN ZONING BOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2009-03-09 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2009-03-09 |
Time |
11:37 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2009-03-09 |
Time |
11:37 |
Sent To |
M |
|
Notes |
2009-03-09 11:38:38 | TO "M" BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2007-12-10 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-12-10 |
Time |
16:31 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-12-10 |
Time |
16:31 |
Sent To |
P |
|
Notes |
2007-12-10 16:32:00 | TO "P" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2007-09-06 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-09-06 |
Time |
10:23 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-09-06 |
Time |
10:23 |
Sent To |
E |
|
Notes |
2007-09-06 10:24:01 | TO "BTROBAUG" DESK/ RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2007-04-23 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2007-04-23 |
Time |
10:29 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2007-03-15 |
Time |
16:35 |
Sent To |
|
|
Notes |
2007-03-15 16:35:17 | TO "SFR""Z" |
|
|
Review Stop |
L |
LANDSCAPING |
Rev No |
1 |
Status |
P |
Date |
2010-07-13 |
|
|
Cont ID |
|
Sent By |
rkussner |
Date |
2010-07-13 |
Time |
11:57 |
Rev Time |
0.00 |
Received By |
rkussner |
Date |
2010-07-13 |
Time |
11:57 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
5 |
Status |
P |
Date |
2009-07-01 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2009-07-01 |
Time |
13:54 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2009-07-01 |
Time |
13:54 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
P |
Date |
2009-06-16 |
|
|
Cont ID |
|
Sent By |
rregueir |
Date |
2009-06-16 |
Time |
08:51 |
Rev Time |
0.00 |
Received By |
rregueir |
Date |
2009-06-15 |
Time |
16:45 |
Sent To |
|
|
Notes |
2009-06-16 08:51:10 | REVISED M1 AND M2 DELTA 2 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2009-04-03 |
|
|
Cont ID |
|
Sent By |
rregueir |
Date |
2009-04-03 |
Time |
16:55 |
Rev Time |
0.00 |
Received By |
rregueir |
Date |
2009-04-03 |
Time |
16:53 |
Sent To |
|
|
Notes |
2009-04-03 16:54:50 | REVISED ENERGY AND COOLING LOAD CALCS. NEED REVISED | | PLANS TO MATCH EQUIPMENT SCHEDULE WITH CALCS. | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | RONALD J. REGUEIRO | | 561.805.6719 | | [email protected] |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2007-09-11 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2007-09-11 |
Time |
14:19 |
Rev Time |
0.45 |
Received By |
tgordon |
Date |
2007-09-11 |
Time |
14:19 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2007-03-27 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2007-03-27 |
Time |
13:44 |
Rev Time |
0.45 |
Received By |
tgordon |
Date |
2007-03-27 |
Time |
13:44 |
Sent To |
P |
|
Notes |
2007-03-27 13:55:24 | *** DENIED *** | | 1) MANUAL J CALCULATIONS ARE CALLING FOR THREE A/C | | SYSTEMS, SYSTEM #1 26,518 SENSIBLE BTU'S, SYSTEM #2 | | 10,694 SENSIBLE BTU'S, AND SYSTEM #3 11,351 SENSIBLE | | BTU'S. MECHANICAL PLANS ARE CALLING FOR A/C SYSTEM #1 | | 44,600 SENSIBLE BTU'S, SYSTEM #2 25,000 SENSIBLE BTU'S, | | AND SYSTEM #3 25,000 SENSIBLE BTU'S. THE PLANS A/C | | SYSTEMS ARE TO LARGE. THE PLANS CAN ONLY CALL FOR 15% | | MORE THAN THE MANUAL J CALCULATIONS, SEE 2004 FBC | | 13-607.1.ABC.1.1 (12-8-07 REVISION). PLEASE CORRECT. | | | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
F |
Date |
2009-06-02 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2009-06-02 |
Time |
08:13 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2009-06-01 |
Time |
16:55 |
Sent To |
|
|
Notes |
2009-06-02 09:53:19 | REVISION OK ADDED -- SHT M-3 CHANGED TWO COMP. SINK TO | | SINGLE BOWL SINK AND ADDED A THREE COMPARTMENT SINK & | | ADDITIONAL D.W. & DISPOSAL. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2007-12-17 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2007-12-17 |
Time |
07:49 |
Rev Time |
0.00 |
Received By |
mperson |
Date |
2007-12-17 |
Time |
07:49 |
Sent To |
|
|
Notes |
2007-12-17 08:23:43 | ****************PROVISO**************** | | 604.9 WATER HAMMER. A WATER-HAMMER | | ARRESTOR SHALL BE INSTALLED WHERE | | QUICK-CLOSING VALVES ARE UTILIZED. | | WATER-HAMMER ARRESTORS SHALL BE INSTALLED IN ACCORDANCE | | WITH THE MANUFACTURER'S SPECIFICATIONS. | | | | REVIEW BY: MIKE PERSON | | PLUMBING PLANS EXAMINER | | (561) 805-6730 | | FAX (561) 805-6731 | | E-MAIL: [email protected] | | | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2007-09-25 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2007-09-25 |
Time |
14:05 |
Rev Time |
0.00 |
Received By |
mperson |
Date |
2007-09-25 |
Time |
14:05 |
Sent To |
G |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2007-03-30 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2007-03-30 |
Time |
13:24 |
Rev Time |
0.55 |
Received By |
mperson |
Date |
2007-03-30 |
Time |
13:24 |
Sent To |
G |
|
Notes |
2007-03-30 13:44:31 | DENIED | | REFERENCE: | | ** FBC-2004 PLUMBING. | | ** FBC-2004 CHAPTER 1, THE CITY OF | | WEST PALM BEACH AMENDMENTS. | | ** FLORIDA ADMINISTRATIVE CODE. | | ** FLORIDA STATUTES. | | | | THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR | | PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE: | | | | 1. FAC-61G1-16.004 TITLE BLOCK: | | A TITLE BLOCK MUST APPEAR ON ALL | | ARCHITECTURAL OR INTERIOR DESIGN | | DRAWINGS AND SPECIFICATION | | IDENTIFICATION SHEETS. THE TITLE BLOCK | | MUST, AT A MINIMUM, CONTAIN THE | | FOLLOWING INFORMATION: | | (1) FIRM NAME, ADDRESS, AND TELEPHONE | | NUMBER. | | (2) FIRM LICENSE NUMBER. | | (3) NAME OR IDENTIFICATION OF PROJECT. | | (4) DATE PREPARED. | | (5) A SPACE FOR THE SIGNATURE AND DATED | | SEAL. | | (6) A SPACE FOR THE PRINTED NAME OF THE | | PERSON SEALING THE DOCUMENT. | | NOTE: IF "SMITH AND MOORE ARCHITECTS, INC." IS A FIRM | | THEN THE FIRMS LICENSE NUMBER IS MISSING FROM THE TITLE | | BLOCK ON ALL SHEETS. PLEASE CORRECT ON THE | | RESUBMITTAL. | | | | 2. SHEET M-3 SANITARY ISOMETRIC RISER DIAGRAM: | | | | A} SECOND FLOOR "BATH #2 ROOM # 206", THE SANITARY | | STACK MUST DRAIN DOWNSTREAM OF FIRST FLOOR "HIS BATH | | ROOM # 113" PER FBC-2004 PLUMBING, SECTIONS 909.1 AND | | 908.3. PLEASE CORRECT ON THE RESUBMITTAL. | | | | B} "HIS BATH ROOM # 113" FLOOR PLAN ON SHEET A-3 | | INDICATES A SHOWER BUT ON THE RISER DIAGRAM A B.T. IS | | INDICATED. PLEASE CORRELATE ON THE RESUBMITTAL. | | | | C} THE FOLLOWING CORRECTIONS ARE REQUIRED FOR THE | | WASHING MACHINE ON THE RESUBMITTAL. | | (A) 406.3 WASTE CONNECTIONS.THE TRAP AND | | FIXTURE DRAIN FOR AN AUTOMATIC CLOTHES | | WASHER SHALL BE A MINIMUM OF 2 INCHES | | (51MM) IN DIAMETER. THE AUTOMATIC | | CLOTHES WASHER FIXTURE DRAIN SHALL | | CONNECT TO A BRANCH DRAIN OR DRAINAGE | | STACK A MINIMUM OF 3 INCHES (76MM) IN | | DIAMETER. PLEASE CORRECT ON THE RESUBMITTAL. | | (B) 802.4 STANDPIPES.STANDPIPES SHALL BE INDIVIDUALLY | | TRAPPED. STANDPIPES SHALL | | EXTEND A MINIMUM OF 18 INCHES (457MM) | | AND A MAXIMUM OF 42 INCHES (1066MM) | | ABOVE THE TRAP WEIR. ACCESS SHALL BE | | PROVIDED TO ALL STANDPIPES AND DRAINS | | FOR RODDING. PLEASE INDICATE THE STANPIPE FOR THE | | WASHING MACHINE ON THE RESUBMITTAL. | | | | 3.PER FBC-2004 CHAPTER 1, SECTION 106.3.5.4 | | RESIDENTIAL (ONE AND TWO-FAMILY) PLEASE SUBMIT A | | PLUMBING SANITARY ISOMETRIC RISER DIAGRAM INDICATING | | ALL WASTE, VENTS, TRAPS AND SIZES WITH CLEANOUT | | LOCATIONS. | | NOTE: NOT ALL PIPES OR TRAPS ARE SIZED AND NOT ALL | | CLEANOUTS ARE INDICATED ON THE SANITARY RISER DIAGRAM | | ON SHEET M-3. | | (A) 708.3.4 BASE OF STACK. A CLEANOUT | | SHALL BE PROVIDED AT THE BASE OF EACH | | WASTE OR SOIL STACK | | (B) 708.3.5 BUILDING DRAIN AND BUILDING | | SEWER JUNCTION. THERE SHALL BE A TWO-WAY | | CLEANOUT NEAR THE JUNCTION OF THE | | BUILDING DRAIN AND THE BUILDING SEWER. | | (C) 708.7 MINIMUM SIZE. CLEANOUTS SHALL | | BE THE SAME NOMINAL SIZE AS THE PIPE | | THEY SERVE UP TO 4 INCHES (102MM) | | (D) 708.9 ACCESS. ACCESS SHALL BE | | PROVIDED TO ALL CLEANOUTS. | | NOTE: CLEANOUT FOR THE WASHING MACHINE TO BE LOCATED AT | | FOUR FEET ABOVE FINNISH FLOOR (4' A.F.F.) | | | | 4. SHEET M-3 PLUMBING NOTES: PLEASE DELETE "AIR | | CHAMBER" FROM NOTE #11 ON THE RESUBMITTAL. | | | | ********IMPORTANT INFORMATION******** | | IN ORDER TO EXPIDITE PLAN REVIEW: WHEN RESUBMITTING, | | PLEASE REPLACE ONLY SHEETS | | WHICH HAVE CHANGED, PLEASE INCLUDE A | | TRANSMITTAL LETTER INDICATING HOW EACH | | ITEM WAS ADDRESSED AND PROVIDE ONE COPY | | OF ALL OLD/VOIDED SHEETS FOR REFERENCE | | ONLY. NOTE: ONLY ONE CORRECTED DRAWING | | IN RED INK FOR REFERENCE FOR | | RESUBMITTAL. | | | | END OF COMMENTS: | | | | REVIEW BY MIKE PERSON | | (561) 805-6730 | | FAX (561) 805-6731 | | E-MAIL [email protected] | | UNDER SUPERVISION OF K.STEVENS | | (561) 805-6721 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2007-03-22 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2007-03-22 |
Time |
14:19 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2007-03-22 |
Time |
14:19 |
Sent To |
I |
|
Notes |
2007-03-22 14:19:57 | PASSED, PER A. JONES-VANN. |
|
|