Plan Review Stops For Permit 07030127 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2007-08-15 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2007-08-15 |
Time |
16:46 |
Rev Time |
0.77 |
Received By |
jwitmer |
Date |
2007-08-15 |
Time |
16:46 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2007-07-07 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2007-07-07 |
Time |
11:36 |
Rev Time |
1.33 |
Received By |
jwitmer |
Date |
2007-07-07 |
Time |
11:36 |
Sent To |
PC |
|
Notes |
2007-07-07 11:37:16 | | | | | | | | | BUILDING PLAN REVIEW | | PERMIT: 07030127 | | ADD: 1400 CENTREPARK BLVD | | CONT: PASS INTERNATIONAL, INC | | TEL: (561)954-9000 | | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | W/ 2006 FBC REVISIONS | | * WEST PALM BEACH AMENDMENTS | | | | 2ND REVIEW | | ACTION: DENIED | | W/ 2006 FBC REVISIONS | | * WEST PALM BEACH AMENDMENTS | | | | | | 1)--- VERY IMPORTANT STATEMENT --- | | PLEASE DO NOT IGNORE! | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | THE REVISION & REMOVE & REPLACE ANY | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | BER, WITH A DESCRIPTION OF THE REVISION | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | 2 ) FL S S 713.13 | | NOTICE OF COMMENCEMENT, TO BE FILED WITH THE CLERK OF | | THE COURT. | | NOTE: 713.13(2) | | IF THE WORK DESCRIBED IN THE NOTICE OFCOMMENCEMENT IS | | NOT ACTUALLY | | COMMENCED WITHIN 90 DAYS AFTER THE RECORDING THEREOF, | | SUCH NOTICE IS | | NULL & VOID. NOTE: 713.13(6)THE POSTING OF THE NOTICE | | OF COMMENCEMENT | | AT THE CONSTRUCTION SITE BEFORE THE FIRST INSPECTION. | | | | 3) NEW COMMENT, THE NEW SHEETS ADDED TO THE PLANS WERE | | NOT SIGNED AND SEALED. | | PLANS, SPECIFICATIONS, REPORTS OR | | OTHER DOCUMENTS PREPARED BY THE DESIGN PROFESSIONAL AND | | BEING FILED FOR PUBLIC | | RECORD SHALL HAVE THE SIGNATURE AND | | SEAL OF THE DESIGN PROFESSIONAL AFFIXED | | TO THE DOCUMENT. | | FL STATE STAT: 61G15-23.002 ENGINEERS | | FL ATATE STAT: 61G16.003 ARCHITECTS | | | | BUILDING PLAN REVIEW II | | JIM WITMER C. B. O. | | | | TEL: (561)805-6715 | | FAX: (561)659-8026 | | E-MAIL: [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2007-04-02 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2007-04-02 |
Time |
08:54 |
Rev Time |
1.33 |
Received By |
jwitmer |
Date |
2007-04-02 |
Time |
08:54 |
Sent To |
|
|
Notes |
2007-04-02 09:17:23 | BUILDING PLAN REVIEW | | PERMIT: 07030127 | | ADD: 1400 CENTREPARK BLVD | | CONT: PASS INTERNATIONAL, INC | | TEL: (561)954-9000 | | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | W/ 2006 FBC REVISIONS | | * WEST PALM BEACH AMENDMENTS | | | | 1STREVIEW | | ACTION: DENIED | | | | 1)--- VERY IMPORTANT STATEMENT --- | | PLEASE DO NOT IGNORE! | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | THE REVISION & REMOVE & REPLACE ANY | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | BER, WITH A DESCRIPTION OF THE REVISION | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | 2 ) FL S S 713.13 | | NOTICE OF COMMENCEMENT, TO BE FILED WITH THE CLERK OF | | THE COURT. | | NOTE: 713.13(2) | | IF THE WORK DESCRIBED IN THE NOTICE OFCOMMENCEMENT IS | | NOT ACTUALLY | | COMMENCED WITHIN 90 DAYS AFTER THE RECORDING THEREOF, | | SUCH NOTICE IS | | NULL & VOID. NOTE: 713.13(6)THE POSTING OF THE NOTICE | | OF COMMENCEMENT | | AT THE CONSTRUCTION SITE BEFORE THE FIRST INSPECTION. | | | | 3) COVERSHEET PROJECT DATA: THE PLANS INDICATE THIS IS | | A TYPE IABUILDING.THIS BUILDING BY THE MINIMUM | | STANDARDS OF THE 2006 FBC IS CONSIDERED A TYPE IB | | BUILDING . | | THE OTHER ISSUE WITH THE BUILDING RATING OF | | "UNPROTECTED" SEE TABLE 601 FOR A TYPE IB BUILDING | | COLUMNS AND FLOORS ARE A MINIMUM OF 2 HR FIRE | | RATINGALSO SEE FOOTNOTE "B". | | | | 4)PLANS SUBMITTED AFTER DEC. 8TH, 2006 WILL BE | | REVIEWED UNDER THE 2006 FBC NOT THE 2004 FBC. | | | | 5)SHEET A-2 DETAIL "A" BREAK ROOM SINK: INDICATES | | DOORS/ FLOOR WITHIN THE BASE CABINET: | | DOORS AND SHELVING AND FLOOR OF THE SINK BASE CABINET | | TO BE REMOVED FOR FRONTAL APPROACH. | | SINKS: | | 11-4.24.2 SINKS, HEIGHT. SINKS SHALL | | BE MOUNTED WITH THE COUNTER NO HIGHER | | THAN 34" ABOVE THE FINISH FLOOR. | | 11-4.24.3 KNEE CLEARANCE THAT IS AT | | LEAST 27" HIGH 30" WIDE, AND 19" DEEP | | SHALL BE PROVIDED UNDERNEATH SINKS. | | 11-4.24.5 CLEAR FLOOR SPACE. | | A CLEAR FLOOR SPACE AT LEAST 30 INCHES BY 48 INCHES | | (760 MM BY 1219 MM) COMPLYING WITH SECTION 11-4.2.4 | | SHALL BE PROVIDED IN FRONT OF A SINK TO ALLOW FORWARD | | APPROACH. THE CLEAR FLOOR SPACE SHALL BE ON AN | | ACCESSIBLE ROUTE AND SHALL EXTEND A MAXIMUM OF 19 | | INCHES (485 MM) UNDERNEATH THE SINK. | | | | BUILDING PLAN REVIEW | | JIM WITMER C. B. O. | | | | TEL: (561)805-6715 | | FAX: (561)659-8026 | | E-MAIL: [email protected] | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
6 |
Status |
P |
Date |
2007-08-29 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2007-08-29 |
Time |
10:14 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2007-08-29 |
Time |
10:14 |
Sent To |
PC |
|
Notes |
2007-08-29 10:17:19 | ** NEW PLANS AND CALCULATIONS SENT VIA FED EX. | | NEW SHEET E-2 WAS INSERTED INOT THE TWO SETS BY THIS | | REVIEWER. | | STAMPED AND ISSUED FOR PERMIT. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
5 |
Status |
F |
Date |
2007-08-28 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2007-08-28 |
Time |
15:14 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2007-08-28 |
Time |
15:14 |
Sent To |
PC |
|
Notes |
2007-08-28 15:25:59 | *** DENIED 5TH TIME** | | | | 1) NOTE: REVISED SHEET E-2 AND ENERGY CALCULATIONS WERE | | SENT VIA FED EX TO THIS OFFICE. THIS REVIEWER IN ORDER | | TO PROCESS PERMITTING REMOVED OLD SHEETS AND INSERTED | | NEW SHEETS INTO THE SETS OF PLANS. | | THE SHEET E-2 WAS STILL MISSING ONE EM LT HOWEVER THIS | | IS BEING REDLINED ON PLANS AND NO CHANGES ARE NEEDED. | | ** PLEASE SEE HOWEVER ALL THREE COPIES OF THE ENERGY | | CALCULATIONS WERE NOT SIGNED, DATED AND SEALED AS | | REQUIRED UNDER FAC 61G15-23.002 AND FS471.025. PLEASE | | KNOW IN-FACT THESE ACTUALLY CONTAINED A RAISED SEAL | | OVER *PHOTO-COPIED* SIGNATURE AND DATE. | | THESE SUBMITTED WERE NOT ORIGINAL. THIS REVIEWER HAS | | CALLED OCI AND SPOKE TO MR. RICHARD CREAVELLE WHO IS | | THE ELECTRICAL ENGINEER. HE IS GOING TO GET WITH THE | | MECHANICAL ENGINEER AND FED-EX ONCE AGAIN NEW ENERGY | | CALCULATIONS TO THIS OFFICE FOR AM DELIVERY ON 8/29. | | THIS OFFICE CAN ONLY REQUEST FOR ITEMS TO BE DONE PER | | CODE AND REGULATED STATUTES AND ADMINISTRATIVE CODES. | | UNDER FLORIDA STATUTES, THIS OFFICE AND SPECIFICALLY | | THIS REVIEWER IS BOUND BY THE LAWS AND RULES OF THE | | STATE NOT TO ISSUE PERMIT UNTIL FOUND COMPLIANT WITH | | THE ADOPTED CODES AND ALL OTHER RULES AND ORDINANCES | | ADOPTED BY THE STATE. | | PERMIT IS READY TO ISSUE ONCE THESE ARE IN THIS OFFICE | | AND FOUND TO BE CORRECT. | | PLANS WILL BE OUT-FRONT ONCE AGAIN ON HOLD WAITING FOR | | NEW CALCULATIONS. | | | | | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
F |
Date |
2007-08-24 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2007-08-24 |
Time |
17:24 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2007-08-24 |
Time |
17:21 |
Sent To |
PC |
|
Notes |
2007-08-27 10:48:35 | *** NOTES ADDED | | | | SPOKE TO ENGINEER 10:40AM, NEW ENERGY CALCULATIONS AND | | SHEET E-2 IS BEING FED-EX . | 2007-08-24 17:29:02 | *** PLANS ARE IN A FAILED STATUS AT THIS TIME. | | CALLED ENGINEER'S OFFICE AT 4:55PM 8/24/07 FOR ITEMS ON | | PLANS AND ENERGY CALCULATIONS TO BE GONE OVER. THERE | | ARE AREAS FOR CONTROL OF DECORATIVE/ACCENT LIGHTING AND | | OTHER SWITCHES SHOWN AS *EMERGENCY SWITCHES* WHICH ARE | | UNCLEAR TO THIS REVIEWER. | | LEFT MESSAGE FOR THE ENGINEER TO CALL BACK. | | PLANS WILL BE PLACED UPFRONT UNDER "P" FOR THE GC ON | | HOLD. | | | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | DEWEY PALMER | | 561-805-6717 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
F |
Date |
2007-08-01 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2007-08-01 |
Time |
15:06 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2007-08-01 |
Time |
12:43 |
Sent To |
|
|
Notes |
2007-08-01 15:06:18 | ** UNSAT 3RD REVIEW ** | | | | | | 1) NOTE: PLEASE SEE SOME AREAS OF PLANS WHERE APPEARS | | ONLY STANDARD ELECTRICAL SWITCHES ARE BEING SHOWN. | | PLEASE SEE REDLINED PLANS. | | 13-415.1.ABC.1.1, .1.2 AND .1.3 FOR ACCENT | | LIGHTING/DECRETIVE LIGHTING. | | PLEASE SEE 13-415.2ABC.1.2 (3) FOR TRACK LIGHTING. | | PLEASE CLARIFY AS THE LOADS ARE BASED ON VA OF THE | | AMOUNT OF FIXTURES OR LINEAR FT OF TRACK PER MIN VA IN | | THE CODE WHICH EVER IS GREATER. | | PLEASE SEE THERE ARE A FEW *SEPARATE SPACES* AND WHAT | | APPEARS AS ACCENT LIGHTING IN ONE ROOM. | | | | | | * ** IMPORTANT** | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | PICKED UP FOR CORRECTIONS, PLEASE BE | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | SHEETS AND ONLY INSERT NEW REVISED | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | AND STAMPING. DO NOT LEAVE ANY | | OLD/VOIDED SHEETS IN SETS. | | PLEASE KNOW ONLY ONE SET OF THE | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | FOR REFERENCE. | | THIS WILL HELP IN THE REVIEW PROCESS AND | | AVOID ANY DELAYS. | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | REVIEWER. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW II | | CONSTRUCTION SERVICES DEPT. | | CITY OF WEST PALM BEACH | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2007-06-19 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2007-06-19 |
Time |
19:43 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2007-06-19 |
Time |
18:54 |
Sent To |
|
|
Notes |
2007-06-19 19:43:55 | *** UNSAT 2ND REVIEW ** | | | | | | ** PLEASE SEE THERE ARE ITEMS FROM PREVIOUS REVIEW | | WHICH ARE STILL NOT ADDRESSED. | | ** PLEASE SEE AS NOTED AND STATED ON PREVIOUS REVIEW AS | | INFORMATION IS ONLY JUST NOW BEING SUBMITTED FOR REVIEW | | THERE ARE NEW COMMENTS. | | | | | | | | 1) NOTE: PLEASE SEE COMPLIANCE WITH THE 2004 FBC | | CHAPTER 13HAS NOT BEEN ACHIEVED ON PLANS FOR CODE | | COMPLIANCE. PLEASE SEE PLANS NOW INDICATE A LIGHTING | | CONTROL PANEL/SYSTEM IS NOW GOING TO BE INSTALLED WHICH | | IS OK, HOWEVER NOT TIME OF SCHEDULING, NO DEVICES FOR | | OVER RIDE OF SYSTEM AT SEPARATE SPACES CONTAINING FLOOR | | TO CEILING HEIGHT PARTITIONS. | | NO TIMES ON OVER RIDES.(MAXIMUM AS STATED PER CODE) | | NO LOCATIONS ON PLANS FOR THESE TYPE(S) OF DEVICES. | | PLEASE SEE THE DEVICES ON LEGEND DO NOT COORDINATE WITH | | PLANS. PLEASE SEE SOME DEVICES ARE SHOWN ON PLANS FOR | | OS TYPE DEVICES YET RESPONSE LETTER MENTIONS THESE ARE | | ALL TO BE REMOVED. IF REMOVED, PLEASE MEET CODE FOR | | DEVICES WHICH ARE REQUIRED. | | PLEASE SEE 13-415.1ABC.1.1, .1.2 AND .1.3. | | ** PLEASE SEE THE ENERGY CALCULATIONS SUBMITTED ARE NOT | | CODE COMPLIANT. PLEASE KNOW AS THE WAS APPLIED FOR | | PERMIT AFTER DECEMBER 8TH, 2006 THE FLA-COM PROGRAMS | | RELEASED FROM THE STATE CONTAINS THE VERSION 3.0 WHICH | | STATES AT THE TOP OF THE SHEET *EFFECTIVE DATE OF | | DECEMBER 8TH, 2006*. | | PLEASE SEE THE NUMBER OF FIXTURES DO NOT CORRELATE WITH | | PLANS. | | PLEASE SEE THE TYPE OF FIXTURES DO NOT CORRELATE WITH | | PLANS. | | PLEASE SEE THE WATTAGE OF FIXTURES DOES NOT CORRELATE | | WITH PLANS. | | PLEASE SEE THE METHOD OF CONTROLS FOR LIGHTING DOES NOT | | CORRELATE. | | PLEASE SEE THE OWNER AGENT IS NOT SIGNED. | | *PLEASE SEE THE FOLLOWING COMMENT #2 WITH RESPECT TO | | SIGNATURE. | | PLEASE SEE AS MOST THE REQUIRED SYSTEM, DEVICES AND | | ENERGY CALCULATIONS ARE NOT COMPLETE OR COMPLIANT A | | REVIEW CAN ONLY BE DONE ON PLANS SUBMITTED. | | 13-415.1.AB.1.1, 13.415.2 | | | | 2) NOTE: AS STATED ON PREVIOUS REVIEW TO PLEASE BE SURE | | TO HAVE THE DESIGNER OF RECORD FOR THE ENERGY | | CALCULATIONS SIGN, DATE AND SEAL THESE AS REQUIRED PER | | 13-103.1.1.1 | | PLEASE SEE THE ENERGY CALCULATIONS AS SUBMITTED IN FACT | | CONTAIN A RAISED SEAL OVER A PHOTO-COPIED SIGNATURE ON | | BOTH SETS SUBMITTED. ONE SET IS BEING RETAINED BY THIS | | OFFICE. | | PLEASE SEE FS 471.025, FAC 61G15-23.002 | | | | 3) NOTE: PLEASE SEE FS 471.025 AS NO SHEETS IN EITHER | | SET OF ELECTRICAL PLANS CONTAINS ANY SIGNATURE, DATE OR | | RAISED SEAL. | | PLEASE SEE FAC 61G15-23.002 | | | | 4) NOTE: PLEASE SEE PLANS DO NOT INDICATE SUFFICIENT | | LIGHTING FIXTURES WITH BATTERY BACK UP FOR MINIMUM | | LIGHTING LEVELS PER LS 7.8, 7.9. | | PLEASE SEE PLANS APPEARS TO SHOW SOME 2X4 LAY-IN | | FIXTURES WITH A LINE WHICH ARE TYPICALLY THE BATTERY | | BACK UP TYPE FIXTURE HOWEVER THE SYMBOL AND FIXTURE | | LEGEND DOES NOT SHOW A DIFFERENCE BETWEEN THE TWO. | | PLEASE SEE OTHER AREAS WHICH SHOW THE WALL MOUNTED | | BATTERY BACK UP FIXTURES WHICH ARE OK. | | PLEASE SEE COMMENTS FROM THE FIRE MARSHAL. | | | | 5) NOTE: PLEASE CLARIFY WHY CONTINUOUS LOADS ARE NOT | | SHOWN ON TRANSFORMER/SERVICE LOADS? | | 215.3, 230.42, 220. | | | | 6) NOTE: PLEASE CLARIFY ANY METERING DEVICES ARE | | LOCATED ON RISER/SERVICE. | | | | 7) NOTE: PLEASE SEE FS 553.80(2)(B) WITH RESPECT TO | | REPEAT COMMENTS FOR CODE COMPLIANCE. SETS OF PLANS HAVE | | BEEN RETAINED. | | | | * ** IMPORTANT** | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | PICKED UP FOR CORRECTIONS, PLEASE BE | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | SHEETS AND ONLY INSERT NEW REVISED | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | AND STAMPING. DO NOT LEAVE ANY | | OLD/VOIDED SHEETS IN SETS. | | PLEASE KNOW ONLY ONE SET OF THE | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | FOR REFERENCE. | | THIS WILL HELP IN THE REVIEW PROCESS AND | | AVOID ANY DELAYS. | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | REVIEWER. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW II | | CONSTRUCTION SERVICES DEPT. | | CITY OF WEST PALM BEACH | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2007-03-10 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2007-03-10 |
Time |
17:07 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2007-03-10 |
Time |
16:03 |
Sent To |
|
|
Notes |
2007-03-10 17:08:43 | ** UNSAT ** | | | | | | 1)NOTE: PLEASE KNOW THAT ANY PERMIT APPLICATIONS WHICH | | ARE SUBMITTED AFTER DECEMBER 8TH, 2006 PLACES PROJECTS | | UNDER THE NEW CODES ADOPTED BY THE STATE. | | PLEASE SEE THAT THIS SHALL INCLUDE 2006 REVISIONS TO | | THE 2004 FBC FOR ALL TRADES AND THE 2005 NFPA-70. | | PLEASE KNOW THERE ARE CHANGES IN THE FBC WHICH MAY | | AFFECT DESIGNS FOR ALL TRADES. | | PLEASE LIST THE FOLLOWING ON ELECTRICAL SHEETS FOR THIS | | REVIEWER AT A MINIMUM. | | 2004 FBC W/ 2006 REVISIONS. | | 2005 NFPA-70 | | 2002 NFPA-72 | | 2003 NFPA-101 | | | | 2) NOTE: PLEASE SEE FBC 2004 11-4.28.1, .2 AND .3(4) | | AND STATE THE MINIMUM HORN, STROBE LEVELS ON PLANS FOR | | ADA REQUIRED AREAS. DEVICES ARE BEING SHOWN ON | | PLANS/LEGEND. | | | | 3) NOTE: PLEASE SEE COMPLIANCE WITH THE 2004 FBC | | CHAPTER 13 FOR CONTROL OF LIGHTING PER 13-415.1ABC.1.1, | | .1.2 AND .1.3. SOME IS SHOWN, HOWEVER NOT ALL AREAS FOR | | CONTROL ARE CLEAR OR SHOWN MEETING THESE SECTIONS. | | PLEASE SUBMIT LIGHTING POWER DENSITIES PER THE 2004 FBC | | W/ 2006 REVISION. PLEASE SEE 13-415.1.AB.1.1, 13-415.2 | | FOR LIGHTING PERFORMANCE CALCULATIONS ALONG WITH ENERGY | | CALCULATIONS. | | PLEASE SEE THAT THE FIXTURE SCHEDULE SHALL BE SPECIFIC | | FOR FIXTURES TO BE INSTALLED AND COORDINATION WITH THE | | LPD/CALCULATIONS IS REVIEWED FOR COMPLIANCE. PLEASE BE | | SURE TO HAVE THE DESIGNER OF RECORD FOR THE ENERGY | | CALCULATIONS SIGN, DATE AND SEAL THESE AS REQUIRED PER | | 13-103.1.1.1 | | | | 4) NOTE: PLEASE CORRELATE RISER AND PANEL LP-5, ONE | | SHOWS MCB AND THE MLO. | | | | 5) NOTE: PLEASE SEE BOTH BATHROOMS MEN'S AND WOMEN'S | | WILL REQUIRE BATTERY BACK UP FIXTURES OF SOME TYPE. | | PLEASE SEE THE FIXTURE *D*, AS TWO SYMBOLS ARE SHOWN | | FOR THE SAME TYPE OF FIXTURE ON PLANS THEFIXTURE | | LEGEND DOES INDICATE BUT ONLY ONE TYPE. | | PLEASE INDICATE A BATTERY BACK UP FIXTURE. | | LS 101 7.8 AND 7.9. | | PLEASE SEE 700.12E FOR CIRCUITING TO LOCAL LIGHTING | | CIRCUIT IN EACH ROOM. | | | | 6) NOTE: PLEASE ADJUST NOTED FOR * LOCK-ON/OFF* DEVICE | | AS NOTED ON PANEL SCHEDULE. | | PLEASE STATE/NOTE THAT THE *LOCK OFF/ON DEVICE SHALL BE | | AN INTEGRAL PART OF THE BREAKER* THIS DEVICE MAY NOT BE | | OF THE TYPE WHICH *SNAPS/CLIPS* ON THE BREAKER. (OR | | WORDS TO THE AFFECT). | | 110.3. | | FBC 106.1.2 ADMIN SECTION FOR ADDITIONAL INFORMATION. | | | | ** PLEASE KNOW AS ENERGY CALCULATIONS/LIGHTING | | PERFORMANCE CALCULATIONS AND INFORMATION FOR LIGHTING | | CONTROL SYSTEM/CONTROLS ARE NOT COMPLETE AT THIS TIME | | FOR REVIEW, THERE MAY BE NEW COMMENTS ON THE FOLLOWING | | REVIEW WHICH HAVE NOT YET BEEN MADE | | | | ** IMPORTANT** | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | PICKED UP FOR CORRECTIONS, PLEASE BE | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | SHEETS AND ONLY INSERT NEW REVISED | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | AND STAMPING. DO NOT LEAVE ANY | | OLD/VOIDED SHEETS IN SETS. | | PLEASE KNOW ONLY ONE SET OF THE | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | FOR REFERENCE. | | THIS WILL HELP IN THE REVIEW PROCESS AND | | AVOID ANY DELAYS. | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | REVIEWER. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CONSTRUCTION SERVICES DEPT. | | CITY OF WEST PALM BEACH | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2007-08-15 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2007-08-15 |
Time |
14:36 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2007-08-15 |
Time |
13:58 |
Sent To |
|
|
Notes |
2007-08-15 14:36:30 | *****APPROVED***** | | | | | | PLAN SHEET A-1, E-2, AND E-3 WERE STAMPED, INITIALED, | | AND DATED. |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2007-08-14 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2007-06-28 |
Time |
16:20 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2007-06-28 |
Time |
15:23 |
Sent To |
|
|
Notes |
2007-06-28 15:24:18 | *****APPROVED***** | | | | | | | | THE APPROPIATE PLAN SHEETS WILL BE STAMPED WHEN OTHER | | PLAN REVIEWS HAVE BEEN SATISFIED. |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2007-04-10 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2007-04-10 |
Time |
17:58 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2007-04-10 |
Time |
15:25 |
Sent To |
|
|
Notes |
2007-04-10 17:58:18 | *****APPROVED***** | | | | | | | | THE APPROPIATE PLAN SHEETS WILL BE STAMPED WHEN OTHER | | PLAN REVIEWS HAVE BEEN SATISFIED. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2007-08-23 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-08-23 |
Time |
10:49 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-08-23 |
Time |
10:49 |
Sent To |
E |
|
Notes |
2007-08-23 10:50:37 | TO "DPALMER" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2007-07-18 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-07-18 |
Time |
11:28 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-07-18 |
Time |
11:28 |
Sent To |
|
|
Notes |
2007-07-27 12:00:57 | TO "COMM" BD#64 | 2007-07-18 11:29:02 | WAITING FOR "COMM" BD |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2007-05-23 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-05-23 |
Time |
15:04 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-05-23 |
Time |
15:04 |
Sent To |
|
|
Notes |
2007-06-14 13:23:48 | TO "COMM" BD#58 | 2007-05-23 15:05:12 | WAITING FOR "COMM" BD |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2007-04-10 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2007-04-10 |
Time |
15:25 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2007-03-06 |
Time |
14:48 |
Sent To |
|
|
Notes |
2007-03-08 13:52:58 | TO "COMM" BD#12 | 2007-03-06 14:48:41 | WAITING FOR "COMM" BD |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2007-06-16 |
|
|
Cont ID |
|
Sent By |
rregueir |
Date |
2007-06-16 |
Time |
09:30 |
Rev Time |
0.00 |
Received By |
rregueir |
Date |
2007-06-16 |
Time |
08:46 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2007-03-30 |
|
|
Cont ID |
|
Sent By |
rregueir |
Date |
2007-03-30 |
Time |
08:30 |
Rev Time |
0.00 |
Received By |
rregueir |
Date |
2007-03-30 |
Time |
07:35 |
Sent To |
|
|
Notes |
2007-03-30 08:30:53 | ----------------DENIED----------------- | | | | 1. PLEASE SHOW DUCTWORK CHANGES RELATED TO THE DELETION | | OF HP-L AND THE ADDITION OF HP-NEW. FBC 106.1.1. | | | | 2. PLEASE SHOW DUCTWORK CHANGES RELATED TO THE | | REDISTRIBUTION OF AIR FROM HP-5 ALONG WITH NEW AIR | | BALANCES TO BE ACHIEVED RELATED TO NOTE 9. FBC | | 106.1.1. | | | | 3. PLEASE SHOW DETAILS RELATED TO NOTE 4 SUCH AS DUCT | | SIZES, LOCATION AND CFM. FBC 106.1.1. | | | | RONALD J REGUEIRO | | 561.805.6719 | | [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2007-08-14 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2007-08-14 |
Time |
16:39 |
Rev Time |
0.00 |
Received By |
mperson |
Date |
2007-08-14 |
Time |
16:38 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2007-07-06 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2007-07-06 |
Time |
08:36 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2007-07-06 |
Time |
08:36 |
Sent To |
|
|
Notes |
2007-07-06 08:39:25 | DENIED | | REFERENCE: FBC-2204 CHAPTER 1 | | | | 1. SHT P-1 THE DESIGN PROFESSIONAL SHALL SIGN, SEAL AND | | DATE ON THE PLUMBING SHEET. SECTION 106.1. | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 805-6731 | | E-MAIL [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2007-03-20 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2007-03-20 |
Time |
06:46 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2007-03-20 |
Time |
06:46 |
Sent To |
|
|
Notes |
2007-03-20 06:57:05 | DENIED | | REFERENCE: FBC-2004 PLUMBING | | FBC-2004 CHAPTER 1 | | FBC-2004 CHAPTER 11 | | FLORIDA ADMINISTRATIVE CODE | | FLORIDA STATUTES | | | | 1. ALL SHEETS. THE ARCHITECT ADDRESS IN THE TITLE | | BLOCKS DO NOT REFLECT THE ADDRESS INDICATED ON THE | | FLORIDA DBPR WEBSITE. (SEE ATTACHED SHEET). PLEASE | | UPDATE THE WEBSITE INFORMATION OR THE TITLE BLOCKS SO | | THEY CORRELATE. FAC 61G1-16.004(1) & FS 481.2055. | | | | 2. SHT A-1 PLAN SHOWS REMOVAL OF THE DRINKING FOUNTAIN. | | PER TABLE 403.1 A DRINKING FOUNTAIN IS REQUIRED. PLEASE | | PROVIDE A DRINKING FOUNTAIN AND INDICATE THE LOCATION. | | | | 3. SHT A-1 PLEASE SHOW THE CLEAR FLOOR SPACE FOR THE | | BREAK ROOM SINK. SECTION 11-4.24.5. | | | | 4. SHT A-2 ELEVATION A. CABINET DOORS ARE NOT ALLOWED | | IN THE CLEAR FLOOR SPACE. PLEASE DELETE. (PER BLDG | | OFFICIAL). | | | | 5. SHT A-3 DETAIL #1 INDICATE CLEARANCE AS REQUIRED IN | | SECTION 11-4.19.2. (29"). | | | | 6. SHT P-1 DOMESTIC WATER RISER DIAGRAM. WATER HAMMER | | ARRESTORS SHALL BE LOCATED NEAR THE FIXTURE IN AN | | "EFFECTIVE RANGE" NOT IN THE CEILING AS SHOWN. PDI-WH | | 201 AND MANUF. INSTALLATION INSTRUCTIONS. | | | | 7. SHT P-1. SUBMIT THE MANUF. SPECIFICATIONS FOR THE | | IWH-1. MUST SHOW LISTING. SECTION 106.1.1. | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 805-6731 | | E-MAIL [email protected] |
|
|