Plan Review Details - Permit 07030070
Plan Review Stops For Permit 07030070
Review Stop B BUILDING (STRUCTURAL)
Rev No 6 Status P Date 2008-04-28 Cont ID  
Sent By jgomez Date 2008-04-28 Time 17:55 Rev Time 0.00
Received By jgomez Date 2008-04-28 Time 17:39 Sent To PC
Notes
2008-04-28 17:57:18SLIDING GLASS DOORS AND LINTELS PRODUCT APPROVAL,
 SURVEY, SOIL TEST REPORT.

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status F Date 2008-04-04 Cont ID  
Sent By jgomez Date 2008-04-04 Time 17:55 Rev Time 0.00
Received By jgomez Date 2008-04-04 Time 17:14 Sent To PC
Notes
2008-04-04 18:25:32SLIDING GLASS DOOR SUBMITTAL, BUILDING REVIEW
 CHECKLIST.
 REVIEW UNDER FBC2004.
  
 1- PROVIDE COPIES OF PRODUCT APPROVAL FOR SLIDING GLASS
 DOORS AS REQUIRED BY DCA RULE 9B-72AS REQUESTED ON
 PREVIOUS COMMENTS.PACKAGE SUBMITTED NOW DOESN'T
 INCLUDE THE PRODUCT APPROVAL AND THERE IS NOT PRODUCT
 APPROVAL IN FILE.
  
 2- ENGINEER LETTER BY LUCAS A. TURNER, P.E. REGARDING
 DOOR ASSEMBLY TO INCLUDE THREE PANELS NEEDS TO PROVIDE
 ENGINEERING ANALYSIS SHOWING HOW THE MIDDLE PANEL IS
 TAKEN INTO CONSIDERATION TO RESIST THE DESIGN LOADS.
 PRODUCT APPROVAL SHOWS THAT TESTED UNIT HAD ONLY TWO
 PANELS ON EACH SIDE. ASSEMBLYWITH TWO PANELS SHOWS
 THAT BOTH PANELS MAY BESUPPORTED ON THREE SIDES,
 WHILEASSEMBLY WITH THREE PANELS SHOWS THAT MIDDLE
 PANEL MAY BE SUPPORTED ONLY ON TWO SIDES (TOP AND
 BOTTOM).PLEASE, PROVIDE ENGINEERING ANALYSIS TO SHOW
 HOW IS THIS ISSUE ADDRESSED. SEC. 106.1.2 CITY
 AMENDMENTS TO FBC 2004 TO VERIFY COMPLIANCE WITH SEC.
 R301 OF 2004 FLORIDA RESIDENTIAL CODE.
  
 ***NOTE: IF YOU HAVE ANY QUESTIONS REGARDING THIS
 ISSUE, PLEASE CONTACT ROBERT BROWN AT (561)805-6652,
 SINCE I SHARED THIS ISSUE WITH HIM BECAUSEI AM GOING
 TO BE AWAY FROMTHE OFFICE UNTIL APRIL 14TH.
  
 3- REMAINDER:
 PLEASE PROVIDE ALL INFORMATION REQUESTED ON PROVISO
 DATED 7/27/07TO AVOID UNNECESSARY DELAYS IN THE
 CERTIFICATE OF OCCUPANCY PROCESS.SEE ATTACHED COPY OR
 REVIEWIT ON-LINE.
  
 JULIO GOMEZ
 BUILDING REVIEW CHECKLIST
 (561)805-6712

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status F Date 2007-10-23 Cont ID  
Sent By jgomez Date 2007-10-23 Time 15:47 Rev Time 0.00
Received By jgomez Date 2007-10-23 Time 15:46 Sent To PC
Notes
2007-10-23 16:05:02NEW SINGLE FAMILY RESIDENCE. BUILDING REVIEW REVISION
 CHECKLIST.
 REVIEW UNDER FLORIDA RESIDENTIAL CODE 2004 AND FBC 2004
 WITH 2006 REVISIONS.
  
 1- CLARIFY WHY SUBMITTING THIS SET OF DRAWINGS SHOWING
 DIFFERENT ASSEMBLIES SINCE MOST OF THE PRODUCT
 APPROVALS WERE SUBMITTED AT TIME OF PERMIT APPROVAL.
 THE ONLY DIFFERENCE IS THAT MOST OF THE PRODUCT
 APPROVALS LISTED IN THIS SET OF DRAWINGS DON'T MATCH
 THOSE ALREADY APPROVED WITH THE PERMIT PACKAGE.IF
 APPROVED PRODUCT APPROVALS ARE GOING TO BE REVISED,
 THEN PROVIDE COPIES OF NEW PRODUCT APPROVALS. ARCHITECT
 OF RECORD TO REVIEW AND APPROVE THEM IN WRITING (NOT
 SIGNING AND SEALING) PRIOR TO SUBMITTAL TO THIS OFFICE.
 SEC. 106.3.3 CITY AMENDMENTS TO FBC 2004.
  
 2- PROVIDE PRODUCT APPROVAL FOR SLIDING GLASS DOORS AS
 SHOWN ON PLANS AND SET OF DRAWINGS SUBMITTED.PRODUCT
 APPROVAL IS NOT IN THE CITY FILE.
  
 3- IF SUBMITTED SET OF DRAWINGS IS TO OBTAIN LOCAL
 PRODUCT APPROVAL, THEN, PROVIDE COMPLETE ENGINEERING
 PACKAGE FOR LOCAL PRODUCT APPROVAL REVIEW BY ROBERT
 BROWN, PLAN REVIEWERS MANAGER. (561)805-6652.
  
 4- THERE IS NO NEED TO SUBMIT TRUSS DRAWINGS FOR
 REVIEW, UNLESS THERE ARE REVISIONS TO ORIGINAL SET OF
 TRUSSES. TRUSS PACKAGE SUBMITTED SHOWS THE SAME DATE AS
 THE TRUSS PACKAGE THAT WAS FILED BY THE BUILDING
 INSPECTOR. THEREFORE, NOT ADDITIONAL REVIEWS ARE
 REQUIRED.TRUSS DRAWINGS ARE CHECKED IN THE FIELDBY
 THE BUILDING INSPECTOR WHEN DOING FRAMING INSPECTIONS.
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2007-07-27 Cont ID  
Sent By jgomez Date 2007-07-27 Time 09:57 Rev Time 0.00
Received By jgomez Date 2007-07-26 Time 18:26 Sent To PC
Notes
2007-07-27 10:01:23BUILDING REVIEW APPROVED WITH PROVISO:
 1- ARCHITECT TO PROVIDE BUILDING CONSTRUCTION TYPE ON
 SHEET T1 AND A4 AS REQUIRED BY SEC. 602.1OF FBC
 2004.
 2- PROVIDE REVISED DRAINAGE PLAN SHOWING WATER BEING
 DIVERTED AWAY FROM NEIGHBOR'S PROPERTY.
 3- REVISE TYPE OF NAIL USED FOR ROOF SHEATHING. NEED
 "RING SHANK NAILS" AS REQUIRED BY SEC. R803.2.3.12004
 FLORIDA RESIDENTIAL CODE.
 4- SOIL TEST REPORT NEED TO HAVE THE CERTIFICATEOF
 AUTHORIZATION NUMBER AS REQUIRED BY SEC. 61G15-23.002
 FLORIDA ADMINISTRATIVE CODE.
 5- ARCHITECT TO REVIEW AND APPROVE IN WRITING PRODUCT
 APPROVAL SUBMITED FOR:
 A) ALUMINUM SLIDING GLASS DOORS NOA 05-1121.08.
 ARCHITECT APPROVED THE FLORIDA PRODUCT APPROVAL COVER
 PAGE FL2038, BUT NOA AND FLORIDA APPROVAL DON'T
 CORRESPOND TO EACH OTHER.
 B) 8" PRECAST LINTELS. SAME THING FROM PREVIOUS
 COMMENT. NOA AND FLORIDA APPROVAL DON'T CORRESPOND TO
 EACH OTHER.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2007-06-18 Cont ID  
Sent By jgomez Date 2007-06-18 Time 13:54 Rev Time 0.00
Received By jgomez Date 2007-06-18 Time 12:39 Sent To Z
Notes
2007-06-18 14:30:09BUILDING REVIEW APPROVED WITH PROVISO:
 1- ARCHITECT TO PROVIDE BUILDING CONSTRUCTION TYPE ON
 SHEET T1 AND A4 AS REQUIRED BY SEC. 602.1OF FBC
 2004.
 2- PROVIDE REVISED DRAINAGE PLAN SHOWING WATER BEING
 DIVERTED AWAY FROM NEIGHBOR'S PROPERTY.
 3- REVISE TYPE OF NAIL USED FOR ROOF SHEATHING. NEED
 "RING SHANK NAILS" AS REQUIRED BY SEC. R803.2.3.12004
 FLORIDA RESIDENTIAL CODE.
 4- SOIL TEST REPORT NEED TO HAVE THE CERTIFICATEOF
 AUTHORIZATION NUMBER AS REQUIRED BY SEC. 61G15-23.002
 FLORIDA ADMINISTRATIVE CODE.
 5- ARCHITECT TO REVIEW AND APPROVE IN WRITING PRODUCT
 APPROVAL SUBMITED FOR:
 A) ALUMINUM SLIDING GLASS DOORS NOA 05-1121.08.
 ARCHITECT APPROVED THE FLORIDA PRODUCT APPROVAL COVER
 PAGE FL2038, BUT NOA AND FLORIDA APPROVAL DON'T
 CORRESPOND TO EACH OTHER.
 B) 8" PRECAST LINTELS. SAME THING FROM PREVIOUS
 COMMENT. NOA AND FLORIDA APPROVAL DON'T CORRESPOND TO
 EACH OTHER.
 6- REVISE ROOF FRAMING PLAN SHOWING WHERE ARE LINTELS
 LB-2 USED. NONE SHOWN ON PLAN.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-04-13 Cont ID  
Sent By jgomez Date 2007-04-13 Time 16:49 Rev Time 0.00
Received By jgomez Date 2007-04-13 Time 12:44 Sent To PC
Notes
2007-04-13 17:00:02BUILDING REVIEW CHECKLIST:
 1- NEED RECORDED NOTICE OF COMMENCEMENT AS REQUIRED BY
 SEC. 713.13 FLORIDA STATUTE.
  
 2- ARCHITECT TO SIGN DRAWINGS WITH ORIGINAL SIGNATURE,
 NOT RUBBER STAMP AS REQUIRED BY SEC. 61G1-16.003
 FLORIDA ADMINISTRATIVE CODE.
  
 3- SHEET T1:UPDATE STRUCTURECONSTRUCTION TYPE.USE
 FBC 2004 FOR CORRECT TYPE OF CONSTRUCTION AND REVISE AS
 REQUIRED.
  
 4- PROVIDE DRAINAGE PLAN AS REQUIRED BY SEC. R401.3OF
 2004 FLORIDA RESIDENTIAL CODE.
 ***NOTE: WATER NEED TO BE DIVERTED SO IT DOESN'T GO TO
 THE NEIGHBOR'S PROPERTY.
  
 5- SHEET A1:FOOTING SHOW ON FOUNDATION PLAN BY ONE
 CAR GARAGE DOESN'T MATCH DETAIL 5. REVISE AS REQUIRED.
  
 6- SHEET A2:A) SPECIFY INSULATION FOR WALL BETWEEN
 ONE CAR GARAGE AND CLUB ROOM.CHAPTER 13 FBC 2004.
  
 B) CLEARLY SPECIFY THAT ROOM NEXT TO THE GARAGE
 (CLUB ROOM) CAN'T BE USED FOR SLEEPING PURPOSES. SEC.
 R309.1 2004 FLORIDA RESIDENTIAL CODE.
  
  
 7- SHEET A4:
 A)FRONT ELEVATION IS MISSING THE DESIGN PRESSURES
 FOR DOORS AND WINDOWS.PROVIDE SUCH INFORMATION.
  
 B) REVISE BUILDING CONSTRUCTION TYPE. SEE FBC 2004
 FOR CORRECT CONSTRUCTION TYPE.
  
 8- SHEET A6:
 A) GARAGE JAMB DETAIL: SPECIFY HOW MUCH EMBEDMENT IS
 REQUIRED FOR THE WEDGE ANCHORS. SEC. 106.1.2 CITY
 AMENDMENTS TO FBC 2004.
  
 B) PROVIDE COMPLETE SCREEN ENCLOSURE ENGINEERED
 INFORMATION OR SPECIFY UNDER A SEPARATE PERMIT.
  
 9- SPECIFY ROOF SHEATHING NAIL TYPE AND SIZE. SEE SEC.
 R803.2.3.1 OF 2004 FLORIDA RESIDENTIAL CODE.
  
 10- ENERGY CALCULATIONS:
 A)NEED TO USE REVISED FORM 600A-2004 R. REVISE AS
 REQUIRED.
  
 B) CONTRACTOR IS THE RIF GROUP, NOT KENCO
 COMMUNITIES. REVISE AS REQUIRED.
  
 11- PROVIDE COMPLETE UL LISTING AND SPECS FOR EXTERIOR
 HOOD ABOVE BBQ.ONLY BBQ INFORMATION WAS PROVIDED AT
 THIS TIME.
  
 12- SURVEY TO HAVE ORIGINAL SIGNATURE, NOT COPY, AS
 REQUIRED BY CHAPTER 472 FLORIDASTATUTE.
  
 13- SOIL TEST REPORT:PROVIDE THE ENGINEERING FIRM
 CERTIFICATE OF AUTHORIZATION NUMBER IN ALL SHEETS AS
 REQUIRED BY SEC. 61G15-23.002 FLORIDA ADMINISTRATIVE
 CODE.
  
 14- THERE WAS A PRODUCT APPROVAL FOR 4", 6" AND 12"
 PRECAST LINTELS. CLARIFY WHERE ARE THESE LINTELS GOING
 TO BE USED. WHY IT WAS APPROVED IF IT DOESN'T APPLY TO
 THIS PROJECT?
  
 15-NOA #03-0605.05 SUBMITTED FOR 8" PRECAST LINTELS
 EXPIRED ON 05/21/06. PROVIDE CURRENT PRODUCT APPROVAL
 AND DESIGNER OF RECORD TO REVIEW AND APPROVE PRIOR TO
 SUBMITTAL.
  
 16-DESIGNER OF RECORD TO REVIEW AND APPROVE NOA
 #05-1121.08 SUBMITTED FOR THE SLIDING GLASS DOORS.
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2007-06-03 Cont ID  
Sent By dpalmer Date 2007-06-03 Time 12:08 Rev Time 0.00
Received By dpalmer Date 2007-06-03 Time 11:50 Sent To M
Notes
2007-06-03 12:08:48REDLINED
  
 DISC FOR CU #2 DOES NOT MEET 110.26

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2007-03-06 Cont ID  
Sent By dpalmer Date 2007-03-06 Time 20:04 Rev Time 0.00
Received By dpalmer Date 2007-03-06 Time 19:17 Sent To Z
Notes
2007-03-06 20:05:29*** UNSAT ***
  
  
 1) NOTE: PLEASE KNOW THAT PERMIT APPLICATION HAS BEEN
 SUBMITTED AFTER DECEMBER 8TH, 2006 WHICH PLACES
 PROJECTS UNDER THE NEW CODES ADOPTED BY THE STATE.
 PLEASE SEE THAT THIS SHALL INCLUDE 2006 REVISIONS TO
 THE 2004 FBC FOR ALL TRADES AND THE 2005 NFPA-70.
 PLEASE KNOW THERE ARE CHANGES IN THE FBC WHICH MAY
 AFFECT DESIGNS FOR ALL TRADES.
 PLEASE LIST THE FOLLOWING ON ELECTRICAL SHEETS FOR THIS
 REVIEWER AT A MINIMUM.
 2004 FBC W/ 2006 REVISIONS
 2005 NFPA-70
 2002 NFPA-72
 2003 NFPA-101
  
 2) NOTE: PLEASE SEE ALL SHEETS IN BOTH SETS OF PLANS
 CONTAIN A *RUBBER STAMP* INSTEAD OF THE REQUIRED
 ORIGINAL SIGNATURE FROM THE ARCHITECT OF RECORD. THIS
 COMMENT HAS BEEN MADE BY THIS OFFICE/REVIEWER ON OTHER
 PROJECTS AND PREVIOUSLY TO THIS DESIGN PROFESSIONAL.
 PLEASE KNOW AS THIS IS STILL BEING DONE ON PLANS, ONE
 SET OF PLANS WILL BE RETAINED BY THIS OFFICE, PLACE
 WITH OTHER PREVIOUSLY HELD PLANS FOR THE SAME COMMENT
 AND FORWARDED TO THE STATE'S LEGAL COUNSEL TO THE
 FLORIDA BOARD OF ARCHITECTS FOR REVIEW.
 PLEASE SEE FS 481.221(2)
 *ALL FINAL CONSTRUCTION DOCUMENTS AND INSTRUMENTS OF
 SERVICE WHICH INCLUDE DRAWINGS, PLANS, SPECIFICATIONS,
 OR REPORTS PREPARED OR ISSUED BY THE REGISTERED
 ARCHITECT AND BEING FILED FOR PUBLIC RECORD SHALL BEAR
 THE SIGNATURE AND SEAL OF THE REGISTERED ARCHITECT WHO
 PREPARED OR APPROVED THE DOCUMENT AND THE DATE ON WHICH
 THEY WERE SEALED. THE SIGNATURE, DATE, AND SEAL SHALL
 BE EVIDENCE OF THE AUTHENTICITY OF THAT TO WHICH THEY
 ARE AFFIXED*
  
 3) NOTE: PLEASE SEE PLANS AND PANEL SCHEDULE INDICATE
 SMOKE DEVICES AS *SD* AND SYMBOL LEGEND HAS THESE AS
 SMOKE DETECTORS.
 PLEASE KNOW THAT A MEETING WAS HELD AT THE SOUTHERN
 SECTION MEETING IN OCT 06 WHERE WE WERE DIRECTLY
 INFORMED BY NFPA THAT THE USE OF SD FOR SMOKE DETECTORS
 ON PLANS FOR RESIDENTIAL HOMES IS NOT ACCEPTABLE WHEN
 THESE DEVICES ANY ACTUALLY FALL UNDER THE DEFINITIONS
 OF SMOKE ALARMS WHICH WOULD BE SHOWN AS SA/SMOKE
 ALARMS.
 THIS INFORMATION WAS NEW TO THIS AHJ AS THE GENERAL USE
 OF THE SD FOR SMOKE DETECTORS WAS ALWAYS ACCEPTED. BY
 THE DEFINITIONS AS STATED IN NFPA-72 A SD/ SMOKE
 DETECTOR IS ONLY A DEVICE WHICH WILL DETECT AND WILL
 NOT SOUND AN AUDIBLE ALARM. THIS WOULD BE DONE BY
 HORN/SIREN TYPE DEVICES. PLEASE SEE THE DEFINITIONS OF
 SA/SMOKE ALARMS; THESE ARE DEVICES WHICH ARE 120V (AS
 SHOWN) AND WOULD DETECT AND SOUND AN ALARM. THIS IS
 SOMETHING THAT IS NOW BEING COMMENTED ON OTHER REVIEWS
 FOR OTHER NEW HOMES.
 ** PLEASE SEE THAT SMOKE ALARMS ARE STATED IN THE FBC
 RESIDENTIAL CODE/ FBC AND IN NFPA-72.
 IF THERE ARE ANY QUESTIONS ON THIS COMMENT PLEASE DO
 NOT HESITATE IN CONTACTING THIS OFFICE*.
 PLEASE SEE NFPA-72 11.5.1.1, 11.8.3
  
 4) NOTE: PLEASE SEE AH#2 AS THE CONDUCTOR SIZE TO THE
 5KW AHU IS SHOWN AS #6. PLEASE KNOW AS IT IS
 PERMISSIBLE BY THE NEC TO INCREASE THE CONDUCTORS, THE
 #6 AS INDICATED WILL NOT FIT UNDER A 30AMP BREAKER AS
 THE CONNECTIONS ARE NOT LISTED FOR THIS SIZE
 CONDUCTOR.
 110.3
  
 5) NOTE: PLEASE SEE MISSING DISCONNECT FOR CU #2 AS
 REQUIRED PER 440.11.
  
 6) NOTE: PLEASE CORRELATE ELECTRICAL PLANS WITH
 MECHANICAL PLANS FOR THE OVER CURRENT PROTECTION DEVICE
 FOR THE CU #3. ELECTRICAL PLANS INDICATE 30AMP AND THE
 MECHANICAL PLANS 50AMP.
 FBC 106.1.2 ADMIN SECTION FOR ADDITIONAL INFORMATION
 AND COORDINATION.
  
 7) NOTE: PLEASE SEE THE WASHER AND DRYER IN THE UTILITY
 ROOM. ONE OR THE OTHER DOES NOT CONTAIN ANY ELECTRICAL
 RECEPTACLE FOR CONNECTION OF THE APPLIANCE.? PLEASE SEE
 PANEL SCHEDULE MENTIONS ONLY A 1-POLE 20AMP CIRCUIT FOR
 DRYER IS THIS GAS?
 PLEASE COMPLETE AND CORRELATE.
 FBC106.3.5.4 ADMIN SECTION.
  
 8) NOTE: PLEASE SEE 210.8A7 FOR REQUIRED GFI PROTECTED
 RECEPTACLES WITHIN 6FT OF A SINK IN LAUNDRY ROOMS.
 PLEASE KNOW THAT THIS INCLUDES *ALL* 15/20AMP 125VOLT ,
 EVEN WASHER. (WASHER BECAME INCLUDE IN THIS CODE CYCLE
 EVEN IF A SINGLE USE DEDICATED OUTLET)
  
 9) NOTE: PLEASE SEE MISSING RECEPTACLE FOR 2FT OR MORE
 OF WALL SPACE IN DINING ROOM PER 210.52.
  
 10) NOTE: PLEASE SEE THE SECTION FOR THE 2004 FBC
 CHAPTER 13 FOR RECESSED LIGHT FIXTURES IS NOW
 13-606.1.ABC.1.2.4.
  
 11) NOTE: PLEASE LABEL ALL APPLIANCES WHICH ARE GAS
 POWERED ON THE PANEL SCHEDULE AS SUCH.
 COOKTOP, DRYER ETC.
 408.4.
  
 12) NOTE: PLEASE SEE FS 472.025(1) FOR THE SITE/SURVEYS
 WHICH ARE REQUIRED TO CONTAIN AN ORIGINAL SIGNATURE.
  
 * ** IMPORTANT**
 ONCE ALL REVIEWS ARE DONE AND PLANS ARE
 PICKED UP FOR CORRECTIONS, PLEASE BE
 SURE TO COMPLETELY REMOVE ALL OLD/VOIDED
 SHEETS AND ONLY INSERT NEW REVISED
 SHEETS INTO TWO COMPLETE SETS FOR REVIEW
 AND STAMPING. DO NOT LEAVE ANY
 OLD/VOIDED SHEETS IN SETS.
 PLEASE KNOW ONLY ONE SET OF THE
 OLD/VOIDED SHEETS SHOULD BE SUBMITTED
 FOR REFERENCE.
 THIS WILL HELP IN THE REVIEW PROCESS AND
 AVOID ANY DELAYS.
  
 ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR
 COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF
 THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY,
 NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO
 NOT HESITATE IN CONTACTING THIS OFFICE AND THIS
 REVIEWER.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CONSTRUCTION SERVICES DEPT.
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 9 Status N Date 2008-04-24 Cont ID  
Sent By adarroug Date 2008-04-24 Time 15:36 Rev Time 0.00
Received By adarroug Date 2008-04-24 Time 15:35 Sent To B
Notes
2008-04-24 15:36:21TO "JGOMEZ" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 8 Status N Date 2008-04-02 Cont ID  
Sent By adarroug Date 2008-04-02 Time 14:57 Rev Time 0.00
Received By adarroug Date 2008-04-02 Time 14:57 Sent To Z
Notes
2008-04-02 14:57:49TO "Z" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2008-04-02 Cont ID  
Sent By adarroug Date 2008-04-02 Time 14:46 Rev Time 0.00
Received By adarroug Date 2008-04-02 Time 14:46 Sent To B
Notes
2008-04-02 14:46:56TO "JGOMEZ" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2007-11-02 Cont ID  
Sent By adarroug Date 2007-11-02 Time 10:44 Rev Time 0.00
Received By adarroug Date 2007-11-02 Time 10:44 Sent To M
Notes
2007-11-02 10:44:41TO "M" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2007-10-10 Cont ID  
Sent By adarroug Date 2007-10-10 Time 15:56 Rev Time 0.00
Received By adarroug Date 2007-10-10 Time 15:56 Sent To B
Notes
2007-10-10 15:57:09TO "JGOMEZ" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2007-07-11 Cont ID  
Sent By adarroug Date 2007-07-11 Time 14:24 Rev Time 0.00
Received By adarroug Date 2007-07-11 Time 14:24 Sent To P
Notes
2007-07-11 14:24:54TO "P" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2007-05-29 Cont ID  
Sent By adarroug Date 2007-05-29 Time 08:56 Rev Time 0.00
Received By adarroug Date 2007-05-29 Time 08:56 Sent To E
Notes
2007-05-29 08:57:03TO "E" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-05-24 Cont ID  
Sent By adarroug Date 2007-05-24 Time 14:45 Rev Time 0.00
Received By adarroug Date 2007-05-24 Time 14:45 Sent To Z
Notes
2007-05-24 14:45:51TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-04-13 Cont ID  
Sent By jgomez Date 2007-04-13 Time 17:00 Rev Time 0.00
Received By jgomez Date 2007-03-06 Time 16:31 Sent To  
Notes
2007-03-06 16:31:28TO "SFR" "Z"

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2007-11-07 Cont ID  
Sent By tgordon Date 2007-11-07 Time 10:02 Rev Time 0.30
Received By tgordon Date 2007-11-07 Time 10:02 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2007-06-08 Cont ID  
Sent By tgordon Date 2007-06-08 Time 08:48 Rev Time 0.30
Received By tgordon Date 2007-06-08 Time 08:48 Sent To P
Notes
2007-06-08 08:49:38*** PROVISO ***
 1) DUCTS IN THE GARAGE AND DUCTS
 PENETRATING THE WALLS OR CEILINGS
 SEPARATING THE DWELLING FROM THE GARAGE
 SHALL BE CONSTRUCTED OF A MINIMUM NO. 26
 GAGE SHEET STEEL OR OTHER APPROVED
 MATERIAL AND SHALL HAVE NO OPENINGS INTO
 THE GARAGE. PER 2004 FBC/R 309.1.1 .
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2007-03-19 Cont ID  
Sent By tgordon Date 2007-03-19 Time 08:37 Rev Time 0.30
Received By tgordon Date 2007-03-19 Time 08:36 Sent To P
Notes
2007-03-19 08:47:43*** DENIED ***
 1) ENERGY CALCULATIONS NEED TO BE ON FORM 600A-04R, SEE
 FBC 13-600.3.A, 12-8-06 REV.
  
 2) COOLING LOAD CALCULATIONS FOR A/C #3 ARE CALLING FOR
 25,246 SENSIBLE BTU'S, MECHANICAL PLANS FOR A/C #3 ARE
 CALLING FOR 43,700 SENSIBLE BTU'S, THE PLANS CAN ONLY
 CALL FOR 15% MORE THAN THE COOLING LOAD CAL'S, SEE 2004
 FBC13-607.1.ABC.1.1, 12-8-06 REV.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.
  

Review Stop P PLUMBING
Rev No 3 Status P Date 2007-07-25 Cont ID  
Sent By mperson Date 2007-07-25 Time 14:20 Rev Time 0.35
Received By mperson Date 2007-07-25 Time 13:45 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2007-06-15 Cont ID  
Sent By mperson Date 2007-06-15 Time 16:07 Rev Time 0.45
Received By mperson Date 2007-06-15 Time 16:07 Sent To B
Notes
2007-06-15 16:33:58DENIED 2ND TIME
 REFERENCE:
 ** FBC-2004 PLUMBING.
 ** FBC-2004 CHAPTER 1, THE CITY OF
 WEST PALM BEACH AMENDMENTS.
 ** FLORIDA ADMINISTRATIVE CODE.
 ** FLORIDA STATUTES.
  
 1. SHEET A6 SANITARY RISER: THE FOLLOWING CORRECTIONS
 ARE REQUIRED FOR THE RESUBMITTED SANITARY ISOMETRIC
 RISER DIAGRAM TO MEET CODE COMPLIANCE.
 A} UTILITY: PLEASE DELETE THE "48" A.F.F."
 INDICATED BELOW THE WASHER, AND CORRECTLY SIZE THE
 STANDPIPE AND TRAP AS BEING 2". PLEASE DELETE THE
 INCORRECTLY IDENTIFIED FIXTURE AS BEING AN 1-1/4" LAV
 AND CORRECTLY IDENTIFY THE FIXTURE AS BEING AN 1-1/2"
 LAUNDRY TRAY (1-1/2" L.T.)
 B} HER BATH: CORRECTLY SIZE THE BRANCH DRAIN TO
 THE BIDET AS BEING TWO INCH AND THE TRAP TO THE BIDET
 AS BEING 1-1/4"
 C} HER BATH: A VENT IS REQUIRED FOR THE SHOWER
 PER FBC-2004 PLUMBING, TABLE 906.1, A TWO INCH TRAP CAN
 NOT BE MORE THAN SIX FEET FROM THE VENT.
  
 ********IMPORTANT INFORMATION********
 IN ORDER TO EXPIDITE PLAN REVIEW: WHEN RESUBMITTING,
 PLEASE REPLACE ONLY SHEETS
 WHICH HAVE CHANGED, PLEASE INCLUDE A
 TRANSMITTAL LETTER INDICATING HOW EACH
 ITEM WAS ADDRESSED AND PROVIDE ONE COPY
 OF ALL OLD/VOIDED SHEETS FOR REFERENCE
 ONLY.
 NOTE: ONLY ONE CORRECTED DRAWING
 IN RED INK FOR REFERENCE FOR
 RESUBMITTAL.
  
 END OF COMMENTS:
  
 REVIEW BY MIKE PERSON
 PLUMBING PLANS EXAMINER
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL [email protected]
 UNDER SUPERVISION OF K.STEVENS
 (561) 805-6721

Review Stop P PLUMBING
Rev No 1 Status F Date 2007-03-28 Cont ID  
Sent By mperson Date 2007-03-28 Time 10:27 Rev Time 1.25
Received By mperson Date 2007-03-28 Time 10:27 Sent To B
Notes
2007-03-28 11:18:02DENIED
 REFERENCE:
 ** FBC-2004 PLUMBING.
 ** FBC-2004 CHAPTER 1, THE CITY OF
 WEST PALM BEACH AMENDMENTS.
  
  
 THE FOLLOWING CORRECTIONS/INFORMATION IS REQUIRED FOR
 PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE:
  
 1. PER FBC-2004 CHAPTER 1 SECTION 106.1.1: INFORMATION
 ON CONSTRUCTION
 DOCUMENTS. CONSTRUCTION DOCUMENTS SHALL
 BE OF SUFFICIENT CLARITY TO INDICATE THE
 LOCATION, NATURE AND EXTENT OF THE WORK
 PROPOSED AND SHOW IN DETAIL THAT IT WILL
 CONFORM TO THE PROVISIONS OF THIS CODE
 AND RELAVENT LAWS, ORDINANCES, RULES AND REGULATIONS,
 AS DETERMINED BY THE
 BUILDING OFFICIAL.
 NOTE: THE SUBMITTED SANITARY ISOMETRIC RISER DIAGRAM ON
 SHEET A6 DOES NOT REFLECT THE FLOOR PLAN ON SHEET A2.
 PLEASE REFERENCE SHEET A2 WITH THIS PLAN REVIEWERS RED
 LINE UNDERGROUND SANITARY SYSTEM INDICATING THE
 FOLLOWING.
  
 A} CABANA BATH: LAV IS INDICATED ON THE WRONG SIDE OF
 THE WATER CLOSET.
  
 B} THE UNDERGROUND BRANCH TO THE KITCHEN IS INDICATED
 IN THE WRONG PLACE.
  
 C} THE UNDERGROUND BRANCH TO BATH #3 IS INDICATED IN
 THE WRONG PLACE.
  
 D} BATH #3: LAV IS MISSING FROM THE SANITARY ISOMETRIC
 RISER DIAGRAM.
  
 E} HER BATH: DOES NOT REFLECT THE FLOOR PLAN.
  
 F} HER BATH: VENT REQUIRED FOR SHOWER PER FBC-2004
 PLUMBING SECTION 901.2.1 AND TABLE 906.1.
  
 G} UTIL. (LAUNDRY ROOM): DOES NOT REFLECT THE FLOOR
 PLAN.
  
 2. SHEET A6 KITCHEN: IS IT THE INTENT TOINSTALL A 7'
 TO 8' WASTE ARM FOR THE DOUBLE BOWL KITCHEN SINK WITH
 DISHWASHER DUE TO THE FACT THAT THERE IS A SNACK BAR
 LOCATED THERE. IT IS SUGGESTED THAT AN AIR ADMITTANCE
 VALVE (STUDOR VENT) BE INSTALLED IN THIS AREA. PER
 FBC-2004 PLUMBING TABLE 906.1 A 2" FIXTURE DRAIN WITH
 AN 1-1/2" TRAP CAN ONLY BE 6' FROM THE VENT. PLEASE
 CLAIFY THIS ON THE RESUBMITTAL.
  
 3. PER FBC-2004 CHAPTER 1, SECTION 106.3.5.4: PLEASE
 SIZE ALL SANITARY PLUMBING AND FIXTURE TRAPS.
  
 ********IMPORTANT INFORMATION********
 IN ORDER TO EXPIDITE PLAN REVIEW: WHEN RESUBMITTING,
 PLEASE REPLACE ONLY SHEETS
 WHICH HAVE CHANGED, PLEASE INCLUDE A
 TRANSMITTAL LETTER INDICATING HOW EACH
 ITEM WAS ADDRESSED AND PROVIDE ONE COPY
 OF ALL OLD/VOIDED SHEETS FOR REFERENCE
 ONLY. NOTE: ONLY ONE CORRECTED DRAWING
 IN RED INK FOR REFERENCE FOR
 RESUBMITTAL.
  
 END OF COMMENTS:
  
 REVIEW BY MIKE PERSON
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL [email protected]
 UNDER SUPERVISION OF K.STEVENS
 (561) 805-6721

Review Stop S SIGNS
Rev No 1 Status P Date 2007-06-19 Cont ID  
Sent By mcruz Date 2007-06-19 Time 18:03 Rev Time 0.00
Received By mcruz Date 2007-06-19 Time 17:26 Sent To I
Notes
***NONE***

Review Stop Z ZONING
Rev No 3 Status P Date 2008-04-03 Cont ID  
Sent By choops Date 2008-04-03 Time 10:59 Rev Time 0.00
Received By choops Date 2008-04-03 Time 10:59 Sent To PC
Notes
2008-04-03 11:00:22***APPROVED - LANDSCAPE PLAN SUBMITTAL***

Review Stop Z ZONING
Rev No 2 Status P Date 2007-07-11 Cont ID  
Sent By choops Date 2007-07-11 Time 14:21 Rev Time 0.00
Received By choops Date 2007-07-11 Time 14:21 Sent To  
Notes
2007-07-11 14:22:28WRONG STOP ENTERED FOR ZONING.APPROVED/STAMPED BY M.
 CRUZ

Review Stop Z ZONING
Rev No 1 Status F Date 2007-03-14 Cont ID  
Sent By mcruz Date 2007-03-14 Time 17:43 Rev Time  
Received By mcruz Date 2007-03-14 Time   Sent To I
Notes
2007-03-14 17:43:12PLANNING & ZONING: ** FAILED**
  
 1.PLEASE PROVIDE RESPONSE IN WRITING.
  
 2.THE SURVEY IS NOT ABSTRACTED, THEREFORE, NO
 ADDITIONAL RECORDS SEARCH HAS BEEN PERFORMED THAT MAY
 INCLUDE ADDITIONAL EASEMENTS.PROVIDE AN ABSTRACTED
 SURVEY WHICH SHOWS THIS ADDITIONAL INFORMATION.
  
 3.IDENTIFY APPURTENENANCES ON THE SIDES OF HOUSE AND
 PROVIDE THE DIMENSIONS AND SETBACKS ON THE SURVEY AND
 SITE PLAN.
  
 4.SHOW THE FRONT SETBACK OF THE ONE CAR GARAGE ON THE
 SURVEY AND SITE PLAN.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT ME.
  
 MARGARITA CRUZ
 ASSOCIATE PLANNER
 PLANNING AND ZONING DEPARTMENT
 561-822-1444
  
  