Plan Review Details - Permit 07020693
Plan Review Stops For Permit 07020693
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2007-04-07 Cont ID  
Sent By shill Date 2007-04-07 Time 13:44 Rev Time 0.00
Received By shill Date 2007-04-07 Time 13:43 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2007-03-23 Cont ID  
Sent By shill Date 2007-03-23 Time 16:12 Rev Time 0.00
Received By shill Date 2007-03-23 Time 16:12 Sent To  
Notes
2007-03-23 16:14:43****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2004
 FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL FBC* CITY
 OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
  
 FROM PREVIOUS LIST
  
  
 _XX_4.COMPLETE THE ATTACHED INSTALLATION SCHEDULE
 OR PROVIDE ALL INFORMATION TO SHOW CODE COMPLIANCE IN
 ANOTHER FORMAT.12" ANCHOR SPACING WAS PROVIDED ON A
 CHART BUT ALL ANCHOR TYPES AND SPACINGS WERE
 HIGHLIGHTED, SOME WHICH WERE CLOSER THAN 12".
  
 2ND REVIEW - NOW THE ANCHOR SCHEDULE IS BLANK IN THE
 FIELD FOR ANCHOR SPACING.TWO DIFFERENT SUBSTRATES
 WITH VARIOUS ANCHOR SPACING WAS HIGHLIGHTED ON THE
 PRODUCT APPROVAL.EITHER SPECIFY THE MOST STRINGENT BY
 CIRCLING IT ON THE PRODUCT APPROVAL, TO APPLY TO ALL
 OPENINGS, OR SPECIFY FOR EACH OPENING THE SUBSTRATE AND
 THE ANCHOR SPACING.
  
 PLEASE USE INK RATHER THAN HIGHLIGHTER AS THE
 HIGHLIGHTER DOES NOT SCAN PROPERLY FOR RECORD KEEPING
 PURPOSES.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-03-07 Cont ID  
Sent By shill Date 2007-03-07 Time 16:22 Rev Time 0.00
Received By shill Date 2007-03-07 Time 16:22 Sent To  
Notes
2007-03-07 16:24:18****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2004
 FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
  
 SHUTTER PERMIT APPLICATION, ONLY CHECKED ITEMS APPLY
  
 ____1.A NOTICE OF COMMENCEMENT MUST BE FILED WITH
 THE CLERK OF COURTS BEFORE A PERMIT CAN BE ISSUED,
 FS713.13.
  
 ____2.PROVIDE BUILDING HEIGHT ON THE PLAN.DESIGN
 PRESSURES FOR BUILDINGS OVER 60FEET ARE REQUIRED TO BE
 DESIGNED USING ASCE7, FBC1609.1.1 AND MUST BE DONE BY A
 DESIGN PROFESSIONAL. DOCUMENTS PREPARED BY AN ENGINEER
 AND SUBMITTED FOR PUBLIC RECORD ARE TO BE SIGNED SEALED
 ORIGINALS FAC61G15-23.002.
  
 ____3.PROVIDE A COPY OF THE CONDO ASSOCIATION
 APPROVAL.
  
 _XX_4.COMPLETE THE ATTACHED INSTALLATION SCHEDULE
 OR PROVIDE ALL INFORMATION TO SHOW CODE COMPLIANCE IN
 ANOTHER FORMAT.12" ANCHOR SPACING WAS PROVIDED ON A
 CHART BUT ALL ANCHOR TYPES AND SPACINGS WERE
 HIGHLIGHTED, SOME WHICH WERE CLOSER THAN 12".
  
 ____5.FLORIDA STATE OR LOCAL PRODUCT APPROVAL
 REQUIRED, FAC9B72, WWW.FLORIDABUILDING.ORG.
  
 ____6.ON THE PRODUCT APPROVAL, MARK WHICH DETAILS
 APPLY TO THIS JOB.PLEASE USE INK RATHER THAN A
 HIGHLIGHTER.
  
 ____7.SHOW THE EMERGENCY MEANS OF ESCAPE, FBC
 R310.
  
 ____8.PROVIDE A FLOOR PLAN SHOWING WHERE THE
 SHUTTERS WILL BE INSTALLED AND PANEL SIZES WHICH
 CORRELATES WITH THE INSTALLATION SCHEDULE, ITEM 4
 ABOVE.
  
 ____9.REVISE EXPOSURE CATEGORY FBC1609.6.2.1(2),
 FBC R301.2.1.4.NOTE THAT THE DEFINITION FOR EXPOSURE
 C HAS CHANGED EFFECTIVE DECEMBER 8, 2006 FBC1609.4, FBC
 R301.2.1.4.
  
  
  

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2007-03-10 Cont ID  
Sent By ssherman Date 2007-03-10 Time 17:01 Rev Time 0.00
Received By ssherman Date 2007-03-10 Time 17:00 Sent To  
Notes
2007-03-10 17:01:06HISTORICAL APPROVAL PER JILLIAN PAPA

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2007-04-03 Cont ID  
Sent By spalmer Date 2007-04-03 Time 18:09 Rev Time 0.00
Received By spalmer Date 2007-04-03 Time 18:09 Sent To B
Notes
2007-04-03 18:09:13TO SAMANTHA HILL

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-03-22 Cont ID  
Sent By adarroug Date 2007-03-22 Time 16:38 Rev Time 0.00
Received By adarroug Date 2007-03-22 Time 16:38 Sent To B
Notes
2007-03-22 16:39:10TO "SHILL" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-03-07 Cont ID  
Sent By shill Date 2007-03-07 Time 16:24 Rev Time 0.00
Received By shill Date 2007-02-27 Time 17:11 Sent To  
Notes
2007-02-27 17:11:32TO "MISC" BOX#1